Nyu clinical experience with total body irradiation: From 3d laterals to image-guided VMAT [Meeting Abstract]

Galavis, P; Hitchen, C; Mccarthy, A; Malin, M; Taneja, S; Ayyalasomayajula, S; Yuan, Y; Gerber, N; Barbee, D; Teruel, J
Purpose: Patients receiving myeloablative total body irradiation (TBI) doses >= 12Gy are at risk of developing interstitial pneumonitis. At our institution, TBI transitioned from extended distance opposed Laterals to image-guided VMAT, in an effort to improve coverage while sparing lungs and kidneys. This work presents a dosimetric comparison between 3D Laterals and VMAT.
Method(s): Nine patients were treated with VMAT as part of an ongoing phase II single-arm clinical trial. VMAT patients were CT-simulated supine, with thermoplastic masks for head/neck, chest/abdomen/pelvis and feet. VMAT planning (12Gy (n=6) or 13.2Gy (n=3) in 8-BID fractions) utilizes 6MV multi-isocentric arcs and AP/PA beams to treat the upper and lower body, respectively. Ten 3D Lateral patients were CT-simulated supine with arms positioned/immobilized for lung shielding, with rice compensation between legs/feet. Laterals plan (12Gy in 8-BID fractions) uses 15MV, beam spoiler, head compensation, and subfields to maintain coverage and mean-lungs dose <10.5Gy. Target (Body-5mm, extending 3mm into lungs and kidneys for VMAT; Body-2cm for Laterals) coverage was evaluated at V100%, and D98% (percentage of Rx). Absolute dose to lungs and kidneys were reportedResults: Median Target V100% and D98% for VMAT was 93.2% (Range: 95.6% to 92.1%) and 90.2% (94.3% to 88.3%), whereas for Laterals V100% and D98% was 57.3% (66.5% to 46.3%) and 80.6% (75.5% to 84%). The median Lung mean dose was 7.6Gy (7.3Gy to 7.9Gy) for VMAT. The median mean dose to kidney was 10.4Gy (10.1Gy to 10.7Gy) for VMAT, and 12.5Gy (11.9Gy to 13.5Gy) for Laterals.
Conclusion(s): We have established a VMAT-TBI program for patients requiring myeloablative irradiation. Improvement in target coverage is demonstrated by V100% and D98%, while reducing the mean dose to the lungs significantly from 10.5Gy to 8Gy
EMBASE:635748271
ISSN: 0094-2405
CID: 4987632

Evaluation of treatment plan uncertainties for vmat TBI [Meeting Abstract]

Duarte, I; Galavis, P; Gerber, N; Barbee, D; Teruel, J
Purpose: To investigate the effect of patient positioning in Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) given the use of multiple isocenters, by simulating offsets in patient positioning and evaluating changes to planned dose distributions.
Method(s): VMAT treatment plans for seven TBI patients treated as part of a prospective stage II clinical trial were evaluated. Plan uncertainties were calculated by introducing 5mm and 10mm translational shifts to the plans' isocenters in the lateral (x), vertical (y), and longitudinal (z) directions. Dose distributions were then re-calculated in the treatment planning system (Eclipse), in order to evaluate dosimetric robustness to one global imaging shift at treatment. Differences in target volume (PTV) coverage and doses to organs at risk were evaluated based on four parameters: lung mean dose, PTV-V100%, PTV-D98%, and kidney mean doses.
Result(s): Lung mean dose increased an average of 8.2cGy, 4.4cGy, and 3.3cGy when shifted 5mm in the x, y, z directions (respectively) across seven patients; 33.2CGy, 18.5cGy, 18.3cGy for 10mm shifts in x, y, z. Target coverage V100% decreased an average of 0.3%, 0.03%, 0.1% for 5mm shifts, and 1.1%, 0.8%, 0.4% for 10mm shifts in x, y, z. D98% decreased 0.9%, 0.3%, 0.3% when shifted 5mm; 3.5%, 2.1%, 1.0% when shifted 10mm in x, y, z. Mean dose to the left kidney increased 6.6cGy, 9.7cGy, 2.8cGy for 5mm, and 28.1cGy, 32.7cGy, 18.0cGy for 10mm shifts in x, y, z. Right kidney mean dose increased 11.9cGy, 8.9cGy, 3.1cGy for 5mm, and 36.5, 30.5, 19.8cGy for 10mm.
Conclusion(s): Though small in relation to total dose, the largest increase in mean lung dose and decrease in coverage was seen with lateral shifts as compared to vertical or longitudinal shifts. These results support the use of an approach with preferential alignment to the chest region (lung-sparing), as long as residual imaging alignment outside the chest is kept below 10mm. Jose Teruel has received honorarium from Varian Medical Systems
EMBASE:635753026
ISSN: 0094-2405
CID: 4987592

Streamlining complex multi-isocentric VMAT based treatment delivery using a newly developed software tool [Meeting Abstract]

Teruel, J; Galavis, P; Osterman, K; Taneja, S; Cooper, B; Gerber, N; Hitchen, C; Barbee, D
Purpose: Multi-isocentric treatment delivery for CSI and TBI poses specific challenges for treatment delivery. We have developed a software tool to streamline all aspects of delivery for therapists and physicists at the machine, as well as to inform attending physicians of setup variability and image residuals at different locations.
Method(s): Our institution delivers VMAT-based CSI and TBI with up to 3 and 7 isocenters, respectively. A software tool was developed to assist with treatment delivery including initial patient setup, patient imaging, automatic calculation of the optimal global shift based on each isocenter's ideal shift, and automatic calculation of each isocenter's couch coordinates. Initial treatment couch coordinates are queried via the Eclipse scripting API. The global shift was calculated prioritizing the head isocenter for CSI treatments and the chest isocenter for TBI treatments by first maximizing residual tolerance at any other location prior to accepting any residual deviation at these locations. Maximum residuals tolerance was determined based on target margins, plan uncertainty and as per physician instructions. Delivery parameters are reported to a document uploaded to ARIA via API.
Result(s): The developed tool was employed for 11 cases. The software tool replaced the need for plan shift comments or instructions for therapists. In particular, its use eliminated the need to provide isocenter shifts to therapists by directly providing final couch parameters for treatment, greatly reducing the risk of delivery errors. The software effectively informed the therapists if any expected tolerance was surpassed, triggering a patient setup evaluation.
Conclusion(s): The described software tool is a core component to our multi-isocenter treatment programs and has streamlined delivery of these complex techniques that would otherwise require complicated instructions, including multiple shifts and on-the-fly calculations of optimal image alignment based on multiple imaging locations. This has substantially reduced the possibility of delivery errors
EMBASE:635748300
ISSN: 0094-2405
CID: 4987622

Investigation into the relationship patient setup accuracy and in-vivo transit dosimetry for image-guided volumetrically modulated total body irradiation (TBI) [Meeting Abstract]

Taneja, S; Teruel, J; Malin, M; Galavis, P; Mccarthy, A; Ayyalasomayajula, S; Hitchen, C; Gerber, N; Yuan, Y; Barbee, D
Purpose: In-vivo dosimetry for conventional total body irradiation (TBI) utilize point detectors placed along the patient surface to confirm the delivered dose matches prescription dose. However, in the volumetrically modulated arc therapy (VMAT) approach to TBI, the electronic portal imager device (EPID) can be utilized to acquire a 2-dimensional transmission fluence plane. This work explores the relationship between patient setup accuracy with transit in-vivo dosimetry.
Method(s): A total of 192 fields were investigated. Each VMAT plan consisted of four isocenters: head, chest, abdomen, and pelvis. Prior to treatment, the patient was imaged at the head, pelvis, and chest. Optimal couch shifts were determined for each isocenter under image guidance. The optimal IGRT shifts were determined using an inhouse application that minimized dose deviation using criteria established through plan uncertainty analysis performed in Eclipse. Translational couch residuals were recorded and defined as the difference in the global shift calculated and the optimal couch position with shifts. Transit dosimetry was measured per arc, and analyzed using SNC PerFRACTION with a gamma criteria of 10%/5mm, 5%/5mm, and 5%/7mm.
Result(s): Based on plan uncertainty analysis, clinical threshold for couch residuals were set to 7 mm (5 mm for chest isocenter) as there would be minimal impact on target coverage and organ sparing at those levels. Transit dosimetry showed that the average pass rate across all fields was 99.6%, 97.0%, and 99.2% for 10%/5mm, 5%/5mm, and 5%/7mm gamma criteria, respectively. Pearson correlation tests showed that there was weak correlation between gamma criteria and couch residuals. At stringent 3%/5mm gamma criteria, moderate correlation was found between lateral couch residuals for the head and chest and the head and chest arc analysis.
Conclusion(s): Transit dosimetry showed high pass rates using our couch residual tolerances, which confirmed the plan uncertainty analysis performed during treatment planning
EMBASE:635748254
ISSN: 0094-2405
CID: 4987642

Reproducibility and standardization in radiomics: Are we there yet?

Chapter by: Galavis, Paulina E.
in: AIP Conference Proceedings by
[S.l.] : American Institute of Physics Inc., 2021
pp. ?-?
ISBN: 9780735440944
CID: 4896992

Tumor sphericity as predictor of tumor changes in patients with HPV positive oropharyngeal carcinoma

Chapter by: Galavis, Paulina E.; Kim, Gene; Tam, Moses; Zan, Elcin; Wang, Wei; Hu, Kenneth
in: AIP Conference Proceedings by
[S.l.] : American Institute of Physics Inc., 2021
pp. ?-?
ISBN: 9780735440944
CID: 4896982

Automatic treatment planning for VMAT-based total body irradiation using Eclipse scripting

Teruel, Jose R; Taneja, Sameer; Galavis, Paulina E; Osterman, K Sunshine; McCarthy, Allison; Malin, Martha; Gerber, Naamit K; Hitchen, Christine; Barbee, David L
The purpose of this work is to establish an automated approach for a multiple isocenter volumetric arc therapy (VMAT)-based TBI treatment planning approach. Five anonymized full-body CT imaging sets were used. A script was developed to automate and standardize the treatment planning process using the Varian Eclipse v15.6 Scripting API. The script generates two treatment plans: a head-first VMAT-based plan for upper body coverage using four isocenters and a total of eight full arcs; and a feet-first AP/PA plan with three isocenters that covers the lower extremities of the patient. PTV was the entire body cropped 5 mm from the patient surface and extended 3 mm into the lungs and kidneys. Two plans were generated for each case: one to a total dose of 1200 cGy in 8 fractions and a second one to a total dose of 1320 cGy in 8 fractions. Plans were calculated using the AAA algorithm and 6 MV photon energy. One plan was created and delivered to an anthropomorphic phantom containing 12 OSLDs for in-vivo dose verification. For the plans prescribed to 1200 cGy total dose the following dosimetric results were achieved: median PTV V100% = 94.5%; median PTV D98% = 89.9%; median lungs Dmean = 763 cGy; median left kidney Dmean = 1058 cGy; and median right kidney Dmean = 1051 cGy. For the plans prescribed to 1320 cGy total dose the following dosimetric results were achieved: median PTV V100% = 95.0%; median PTV D98% = 88.7%; median lungs Dmean = 798 cGy; median left kidney Dmean = 1059 cGy; and median right kidney Dmean = 1064 cGy. Maximum dose objective was met for all cases. The dose deviation between the treatment planning dose and the dose measured by the OSLDs was within ±4%. In summary, we have demonstrated that scripting can produce high-quality plans based on predefined dose objectives and can decrease planning time by automatic target and optimization contours generation, plan creation, field and isocenter placement, and optimization objectives setup.
PMID: 33565214
ISSN: 1526-9914
CID: 4779762

Assessment of Texture Feature Robustness Using a Novel 3D-Printed Phantom [Meeting Abstract]

Spuhler, K.; Teruel, J.; Galavis, P.
ISI:000699823200506
ISSN: 0094-2405
CID: 5320862

Initial Experience in MRI-Based Brain Metastases Detection Using Deep Learning [Meeting Abstract]

Teruel, J.; Bernstein, K.; Galavis, P.; Spuhler, K.; Silverman, J.; Kondziolka, D.; Osterman, K.
ISI:000699863600701
ISSN: 0094-2405
CID: 5320872

Interprofessional Image Verification Workshop for Physician and Physics Residents: A Multi-Institutional Experience [Meeting Abstract]

Padilla, L.; Burmeister, J. W.; Burnett, O. L. L., III; Covington, E.; Den, R. B.; Dominello, M. M.; Du, K. L.; Galavis, P.; Junell, S.; Kahn, J.; Kishore, M.; Mooney, K.; Studenski, M. T.; Yechieli, R.; Fields, E. C.
ISI:000582521501440
ISSN: 0360-3016
CID: 4686242