Try a new search

Format these results:

Searched for:

in-biosketch:yes

person:sriniv03

Total Results:

139


Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning

Gabriele, Michelle L; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Wojtkowski, Maciej; Srinivasan, Vivek J; Fujimoto, James G; Duker, Jay S; Schuman, Joel S
PURPOSE: To determine the retinal nerve fiber layer (RNFL) thickness profile in the peripapillary region of healthy eyes. METHODS: Three-dimensional, Fourier/spectral domain optical coherence tomography (OCT) data were obtained as raster scan data (512 x 180 axial scans in a 6 x 6-mm region centered on the optic nerve head [ONH]) with high-speed, ultrahigh-resolution OCT (hsUHR-OCT) from 12 healthy subjects. RNFL thickness was measured on this three-dimensional data set with an in-house software program. The disc margin was defined subjectively in each image and RNFL thickness profiles relative to distance from the disc center were computed for quadrants and clock hours. A mixed-effects model was used to characterize the slope of the profiles. RESULTS: Thickness profiles in the superior, inferior, and temporal quadrants showed an initial increase in RNFL thickness, an area of peak thickness, and a linear decrease as radial distance from the disc center increased. The nasal quadrant showed a constant linear decay without the initial RNFL thickening. A mixed-effects model showed that the slopes of the inferior, superior, and nasal quadrants differed significantly from the temporal slope (P = 0.0012, P = 0.0003, and P = 0.0004, respectively). CONCLUSIONS: RNFL thickness is generally inversely related to the distance from the ONH center in the peripapillary region of healthy subjects, as determined by hsUHR-OCT. However, several areas showed an initial increase in RNFL, followed by a peak and a gradual decrease.
PMCID:1950319
PMID: 17591885
ISSN: 0146-0404
CID: 1886112

Spectral oximetry assessed with high-speed ultra-high-resolution optical coherence tomography

Kagemann, Larry; Wollstein, Gadi; Wojtkowski, Maciej; Ishikawa, Hiroshi; Townsend, Kelly A; Gabriele, Michelle L; Srinivasan, Vivek J; Fujimoto, James G; Schuman, Joel S
We use Fourier domain optical coherence tomography (OCT) data to assess retinal blood oxygen saturation. Three-dimensional disk-centered retinal tissue volumes were assessed in 17 normal healthy subjects. After removing DC and low-frequency a-scan components, an OCT fundus image was created by integrating total reflectance into a single reflectance value. Thirty fringe patterns were sampled; 10 each from the edge of an artery, adjacent tissue, and the edge of a vein, respectively. A-scans were recalculated, zeroing the DC term in the power spectrum, and used for analysis. Optical density ratios (ODRs) were calculated as ODR(Art)=ln(Tissue(855)Art(855))ln(Tissue(805)Art(805)) and ODR(Vein)=ln(Tissue(855)Vein(855))ln(Tissue(805)Vein(805)) with Tissue, Art, and Vein representing total a-scan reflectance at the 805- or 855-nm centered bandwidth. Arterial and venous ODRs were compared by the Wilcoxon signed rank test. Arterial ODRs were significantly greater than venous ODRs (1.007+/-2.611 and -1.434+/-4.310, respectively; p=0.0217) (mean+/-standard deviation). A difference between arterial and venous blood saturation was detected. This suggests that retinal oximetry may possibly be added as a metabolic measurement in structural imaging devices.
PMCID:2916162
PMID: 17867801
ISSN: 1083-3668
CID: 1886122

High-speed ultra-high-resolution optical coherence tomography findings in hydroxychloroquine retinopathy

Rodriguez-Padilla, Julio A; Hedges, Thomas R 3rd; Monson, Bryan; Srinivasan, Vivek; Wojtkowski, Maciej; Reichel, Elias; Duker, Jay S; Schuman, Joel S; Fujimoto, James G
OBJECTIVES: To compare structural changes in the retina seen on high-speed ultra-high-resolution optical coherence tomography (hsUHR-OCT) with multifocal electroretinography (mfERG) and automated visual fields in patients receiving hydroxychloroquine. METHODS: Fifteen patients receiving hydroxychloroquine were evaluated clinically with hsUHR-OCT, mfERG, and automated visual fields. Six age-matched subjects were imaged with hsUHR-OCT and served as controls. RESULTS: Distinctive discontinuity of the perifoveal photoreceptor inner segment/outer segment junction and thinning of the outer nuclear layer were seen with hsUHR-OCT in patients with mild retinal toxic effects. Progression to complete loss of the inner segment/outer segment junction and hyperscattering at the outer segment level were seen in more advanced cases. The mfERG abnormalities correlated with the hsUHR-OCT findings. Asymptomatic patients had normal hsUHR-OCT and mfERG results. CONCLUSION: Distinctive abnormalities in the perifoveal photoreceptor inner segment/outer segment junction were seen on hsUHR-OCT in patients receiving hydroxychloroquine who also were symptomatic and had abnormalities on automated visual fields and mfERG.
PMCID:1993817
PMID: 17562988
ISSN: 0003-9950
CID: 1886132

Peripapillary schisis in glaucoma patients with narrow angles and increased intraocular pressure [Case Report]

Kahook, Malik Y; Noecker, Robert J; Ishikawa, Hiroshi; Wollstein, Gadi; Kagemann, Larry; Wojtkowski, Maciej; Duker, Jay S; Srinivasan, Vivek J; Fujimoto, James G; Schuman, Joel S
PURPOSE: To describe two cases of peripapillary retinal schisis in patients with glaucoma without evidence of optic nerve pits, pseudopits, or X-linked retinoschisis. DESIGN: Two observational case reports and literature review. METHODS: Imaging of the peripapillary nerve fiber layer and schisis cavities was completed in two patients, and one patient was followed over time. RESULTS: The first patient, diagnosed with narrow angle glaucoma, was noted to have peripapillary schisis in the right eye with matching changes on visual field and optical coherence tomographic (OCT) results. Follow-up examination revealed that the schisis disappeared in the right eye while appearing in the left. The findings were verified with high-speed ultra-high-resolution OCT performed in both eyes. The second case involved a patient with anatomically narrow angles, high intraocular pressure (IOP), and peripapillary schisis extending into the macula. CONCLUSIONS: Peripapillary retinoschisis may represent a unique sequelae of intraocular fluctuations in patients with uncontrolled glaucoma. Further studies are needed to better understand this disease process.
PMCID:1941763
PMID: 17386284
ISSN: 0002-9394
CID: 1886142

Noninvasive volumetric imaging and morphometry of the rodent retina with high-speed, ultrahigh-resolution optical coherence tomography

Srinivasan, Vivek J; Ko, Tony H; Wojtkowski, Maciej; Carvalho, Mariana; Clermont, Allen; Bursell, Sven-Erik; Song, Qin Hui; Lem, Janis; Duker, Jay S; Schuman, Joel S; Fujimoto, James G
PURPOSE: To demonstrate high-speed, ultrahigh-resolution optical coherence tomography (OCT) for noninvasive, in vivo, three-dimensional imaging of the retina in rat and mouse models. METHODS: A high-speed, ultrahigh-resolution OCT system using spectral, or Fourier domain, detection has been developed for small animal retinal imaging. Imaging is performed with a contact lens and postobjective scanning. An axial image resolution of 2.8 mum is achieved with a spectrally broadband superluminescent diode light source with a bandwidth of approximately 150 nm at approximately 900-nm center wavelength. Imaging can be performed at 24,000 axial scans per second, which is approximately 100 times faster than previous ultrahigh-resolution OCT systems. High-definition and three-dimensional retinal imaging is performed in vivo in mouse and rat models. RESULTS: High-speed, ultrahigh-resolution OCT enabled high-definition, high transverse pixel density imaging of the murine retina and visualization of all major intraretinal layers. Raster scan protocols enabled three-dimensional volumetric imagingand comprehensive retinal segmentation algorithms allowed measurement of retinal layers. An OCT fundus image, akin to a fundus photograph was generated by axial summation of three-dimensional OCT data, thus enabling precise registration of OCT measurements to retinal fundus features. CONCLUSIONS: High-speed, ultrahigh-resolution OCT enables imaging of retinal architectural morphology in small animal models. OCT fundus images allow precise registration of OCT images and repeated measurements with respect to retinal fundus features. Three-dimensional OCT imaging enables visualization and quantification of retinal structure, which promises to allow repeated, noninvasive measurements to track disease progression, thereby reducing the need for killing the animal for histology. This capability can accelerate basic research studies in rats and mice and their translation into clinical patient care.
PMCID:1941766
PMID: 17122144
ISSN: 0146-0404
CID: 1886232

Persistence of Cloquet's canal in normal healthy eyes

Kagemann, Larry; Wollstein, Gadi; Ishikawa, Hiroshi; Gabriele, Michelle L; Srinivasan, Vivek J; Wojtkowski, Maciej; Duker, Jay S; Fujimoto, James G; Schuman, Joel S
PURPOSE: Optic nerve head (ONH) structural imaging with state-of-the-art, high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT). DESIGN: Observational cohort study. METHODS: ONH centered 3-dimensional (94,371,840 voxel measurements in a 6- x 6- x 1.4-mm tissue volume) hsUHR-OCT data were obtained in one eye from each of six males and nine females normal healthy volunteers (40 +/- 9 years of age). The presence of structures projecting anteriorly from the disk into the vitreous was noted. RESULTS: Structures were noted in 14 of 15 (93%) examined eyes, emanating from the rim of the ONH at the nasal inferior sector, presenting as thin tissue meandering into the vitreous. CONCLUSIONS: Previous technologies provided limited visualization of ONH structures. The ability to scan the entire disk using 3-dimensional OCT (3D-OCT) in a high-density raster pattern reveals a high frequency of persistence of Cloquet's canal in the normal healthy eye.
PMCID:1939820
PMID: 17056372
ISSN: 0002-9394
CID: 1886242

High-definition and 3-dimensional imaging of macular pathologies with high-speed ultrahigh-resolution optical coherence tomography

Srinivasan, Vivek J; Wojtkowski, Maciej; Witkin, Andre J; Duker, Jay S; Ko, Tony H; Carvalho, Mariana; Schuman, Joel S; Kowalczyk, Andrzej; Fujimoto, James G
OBJECTIVE: To assess high-speed ultrahigh-resolution optical coherence tomography (OCT) image resolution, acquisition speed, image quality, and retinal coverage for the visualization of macular pathologies. DESIGN: Retrospective cross-sectional study. PARTICIPANTS: Five hundred eighty-eight eyes of 327 patients with various macular pathologies. METHODS: High-speed ultrahigh-resolution OCT images were obtained in 588 eyes of 327 patients with selected macular diseases. Ultrahigh-resolution OCT using Fourier/spectral domain detection achieves approximately 3-mum axial image resolutions, acquisition speeds of approximately 25 000 axial scans per second, and >3 times finer resolution and >50 times higher speed than standard OCT. Three scan protocols were investigated. The first acquires a small number of high-definition images through the fovea. The second acquires a raster series of high-transverse pixel density images. The third acquires 3-dimensional OCT data using a dense raster pattern. Three-dimensional OCT can generate OCT fundus images that enable precise registration of OCT images with the fundus. Using the OCT fundus images, OCT results were correlated with standard ophthalmoscopic examination techniques. MAIN OUTCOME MEASURES: High-definition macular pathologies. RESULTS: Macular holes, age-related macular degeneration, epiretinal membranes, diabetic retinopathy, retinal dystrophies, central serous chorioretinopathy, and other pathologies were imaged and correlated with ophthalmic examination, standard OCT, fundus photography, and fluorescein angiography, where applicable. High-speed ultrahigh-resolution OCT generates images of retinal pathologies with improved quality, more comprehensive retinal coverage, and more precise registration than standard OCT. The speed preserves retinal topography, thus enabling the visualization of subtle changes associated with disease. High-definition high-transverse pixel density OCT images improve visualization of photoreceptor and pigment epithelial morphology, as well as thin intraretinal and epiretinal structures. Three-dimensional OCT enables comprehensive retinal coverage, reduces sampling errors, and enables assessment of 3-dimensional pathology. CONCLUSIONS: High-definition 3-dimensional imaging using high-speed ultrahigh-resolution OCT improves image quality, retinal coverage, and registration. This new technology has the potential to become a useful tool for elucidating disease pathogenesis and improving disease diagnosis and management.
PMCID:1939823
PMID: 17074565
ISSN: 1549-4713
CID: 1886252

Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography

Wojtkowski, Maciej; Srinivasan, Vivek; Fujimoto, James G; Ko, Tony; Schuman, Joel S; Kowalczyk, Andrzej; Duker, Jay S
PURPOSE: To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS: Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain detection enables dramatic increases in imaging speeds. Three-dimensional OCT retinal imaging is performed in normal human subjects using high-speed ultrahigh-resolution OCT. Three-dimensional OCT data of the macula and optic disc are acquired using a dense raster scan pattern. New processing and display methods for generating virtual OCT fundus images; cross-sectional OCT images with arbitrary orientations; quantitative maps of retinal, nerve fiber layer, and other intraretinal layer thicknesses; and optic nerve head topographic parameters are demonstrated. RESULTS: Three-dimensional OCT imaging enables new imaging protocols that improve visualization and mapping of retinal microstructure. An OCT fundus image can be generated directly from the 3D OCT data, which enables precise and repeatable registration of cross-sectional OCT images and thickness maps with fundus features. Optical coherence tomography images with arbitrary orientations, such as circumpapillary scans, can be generated from 3D OCT data. Mapping of total retinal thickness and thicknesses of the nerve fiber layer, photoreceptor layer, and other intraretinal layers is demonstrated. Measurement of optic nerve head topography and disc parameters is also possible. Three-dimensional OCT enables measurements that are similar to those of standard instruments, including the StratusOCT, GDx, HRT, and RTA. CONCLUSION: Three-dimensional OCT imaging can be performed using high-speed ultrahigh-resolution OCT. Three-dimensional OCT provides comprehensive visualization and mapping of retinal microstructures. The high data acquisition speeds enable high-density data sets with large numbers of transverse positions on the retina, which reduces the possibility of missing focal pathologies. In addition to providing image information such as OCT cross-sectional images, OCT fundus images, and 3D rendering, quantitative measurement and mapping of intraretinal layer thickness and topographic features of the optic disc are possible. We hope that 3D OCT imaging may help to elucidate the structural changes associated with retinal disease as well as improve early diagnosis and monitoring of disease progression and response to treatment.
PMCID:1939719
PMID: 16140383
ISSN: 1549-4713
CID: 1886472

Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation

Wojtkowski, Maciej; Srinivasan, Vivek; Ko, Tony; Fujimoto, James; Kowalczyk, Andrzej; Duker, Jay
Ultrahigh-resolution optical coherence tomography uses broadband light sources to achieve axial image resolutions on the few micron scale. Fourier domain detection methods enable more than an order of magnitude increase in imaging speed and sensitivity, thus overcoming the sensitivity limitations inherent in ultrahigh-resolution OCT using standard time domain detection. Fourier domain methods also provide direct access to the spectrum of the optical signal. This enables automatic numerical dispersion compensation, a key factor in achieving ultrahigh image resolutions. We present ultrahigh-resolution, high-speed Fourier domain OCT imaging with an axial resolution of 2.1 ìm in tissue and 16,000 axial scans per second at 1024 pixels per axial scan. Ultrahigh-resolution spectral domain OCT is shown to provide a ~100x increase in imaging speed when compared to ultrahigh-resolution time domain OCT. In vivo imaging of the human retina is demonstrated. We also present a general technique for automatic numerical dispersion compensation, which is applicable to spectral domain as well as swept source embodiments of Fourier domain OCT.
PMID: 19475077
ISSN: 1094-4087
CID: 4355252