Measuring articulatory movements with an electromagnetic midsagittal articulometer (EMMA) system
Chapter by: Svirsky MA
in: Measuring speech production by
Woodbury NY : Acoustical Society of America, 1993
pp. ?-?
ISBN: n/a
CID: 5013
Electromagnetic midsagittal articulometer systems for transducing speech articulatory movements
Perkell, J S; Cohen, M H; Svirsky, M A; Matthies, M L; Garabieta, I; Jackson, M T
This paper describes two electromagnetic midsagittal articulometer (EMMA) systems that were developed for transducing articulatory movements during speech production. Alternating magnetic fields are generated by transmitter coils that are mounted in an assembly that fits on the head of a speaker. The fields induce alternating voltages in a number of small transducer coils that are attached to articulators in the midline plane, inside and outside the vocal tract. The transducers are connected by fine lead wires to receiver electronics whose output voltages are processed to yield measures of transducer locations as a function of time. Measurement error can arise with this method, because as the articulators move and change shape, the transducers can undergo a varying amount of rotational misalignment with respect to the transmitter axes; both systems are designed to correct for transducer misalignment. For this purpose, one system uses two transmitters and biaxial transducers; the other uses three transmitters and single-axis transducers. The systems have been compared with one another in terms of their performance, human subjects compatibility, and ease of use. Both systems can produce useful midsagittal-plane data on articular movement, and each one has a specific set of advantages and limitations. (Two commercially available systems are also described briefly for comparison purposes). If appropriate experimental controls are used, the three-transmitter system is preferable for practical reasons
PMID: 1474223
ISSN: 0001-4966
CID: 67978
Effects of short-term auditory deprivation on speech production in adult cochlear implant users
Svirsky, M A; Lane, H; Perkell, J S; Wozniak, J
Speech production parameters of three postlingually deafened adults who use cochlear implants were measured: after 24 h of auditory deprivation (which was achieved by turning the subject's speech processor off); after turning the speech processor back on; and after turning the speech processor off again. The measured parameters included vowel acoustics [F1, F2, F0, sound-pressure level (SPL), duration and H1-H2, the amplitude difference between the first two spectral harmonics, a correlate of breathiness] while reading word lists, and average airflow during the reading of passages. Changes in speech processor state (on-to-off or vice versa) were accompanied by numerous changes in speech production parameters. Many changes were in the direction of normalcy, and most were consistent with long-term speech production changes in the same subjects following activation of the processors of their cochlear implants [Perkell et al., J. Acoust. Soc. Am. 91, 2961-2978 (1992)]. Changes in mean airflow were always accompanied by H1-H2 (breathiness) changes in the same direction, probably due to underlying changes in laryngeal posture. Some parameters (different combinations of SPL, F0, H1-H2 and formants for different subjects) showed very rapid changes when turning the speech processor on or off. Parameter changes were faster and more pronounced, however, when the speech processor was turned on than when it was turned off. The picture that emerges from the present study is consistent with a dual role for auditory feedback in speech production: long-term calibration of articulatory parameters as well as feedback mechanisms with relatively short time constants
PMID: 1401516
ISSN: 0001-4966
CID: 67979
Speech of cochlear implant patients: a longitudinal study of vowel production
Perkell, J; Lane, H; Svirsky, M; Webster, J
Acoustic parameters were measured for vowels spoken in /hVd/ context by four postlingually deafened recipients of multichannel (Ineraid) cochlear implants. Three of the subjects became totally deaf in adulthood after varying periods of partial hearing loss; the fourth became totally deaf at age four. The subjects received different degrees of perceptual benefit from the prosthesis. Recordings were made before, and at intervals following speech processor activation. The measured parameters included F1, F2, F0, SPL, duration, and amplitude difference between the first two harmonic peaks in the log magnitude spectrum (H 1-H2). Numerous changes in parameter values were observed from pre- to post-implant, with differences among subjects. Many changes, but not all, were in the direction of normative data, and most changes were consistent with hypotheses about relations among the parameters. Some of the changes tended to enhance phonemic contrasts; others had the opposite effect. For three subjects, H 1-H2 changed in a direction consistent with measurements of their average air flow when reading; that relation was more complex for the fourth subject. The results are interpreted with respect to: characteristics of the individual subjects, including vowel identification scores; mechanical interactions among glottal and supraglottal articulations; and hypotheses about the role of auditory feedback in the control of speech production. Almost all the observed differences could be attributed to changes in the average settings of speaking rate, F0 and SPL, which presumably can be perceived without the need for spectral place information. Some observed F2 realignment may be attributable to the reception of spectral cues
PMID: 1629489
ISSN: 0001-4966
CID: 97945
Propuesta de norma de almacenamiento de senales
Simini F; Handler P; Puchet J; Basalo S; Echague JV; Svirsky MA
ORIGINAL:0006522
ISSN: 0102-2644
CID: 97947
Effect of different types of auditory stimulation on vowel formant frequencies in multichannel cochlear implant users
Svirsky, M A; Tobey, E A
Two experiments investigating the effects of auditory stimulation delivered via a Nucleus multichannel cochlear implant upon vowel production in adventitiously deafened adult speakers are reported. The first experiment contrasts vowel formant frequencies produced without auditory stimulation (implant processor OFF) to those produced with auditory stimulation (processor ON). Significant shifts in second formant frequencies were observed for intermediate vowels produced without auditory stimulation; however, no significant shifts were observed for the point vowels. Higher first formant frequencies occurred in five of eight vowels when the processor was turned ON versus OFF. A second experiment contrasted productions of the word 'head' produced with a FULL map, OFF condition, and a SINGLE channel condition that restricted the amount of auditory information received by the subjects. This experiment revealed significant shifts in second formant frequencies between FULL map utterances and the other conditions. No significant differences in second formant frequencies were observed between SINGLE channel and OFF conditions. These data suggest auditory feedback information may be used to adjust the articulation of some speech sounds
PMID: 1918629
ISSN: 0001-4966
CID: 67980
Changes in speech breathing following cochlear implant in postlingually deafened adults
Lane, H; Perkell, J; Svirsky, M; Webster, J
Three postlingually deafened adults who received cochlear implants read passages before and after their prostheses were activated while their lung volumes were measured with an inductive plethysmograph that transduced the cross-sectional areas of the speaker's chest and abdomen. Lung volumes at the initiation and termination of the speakers' expiratory limbs, their average air flow, and the volume of air they expended per syllable were derived from tracings of calibrated lung volume displayed by computer. The activation of the speakers' cochlear prostheses was followed in every case by a significant change in average airflow, which rose for two subjects with initially low flow rates and fell for one subject who had a much higher average preimplant flow rate. These changes in average flow rate were accompanied by corresponding changes in volume of air expended per syllable, statistically reliable in two of the three cases. There were no significant changes in the levels at which speakers initiated their expiratory limbs, but one speaker, after his prosthesis was activated, reliably increased the level of air in his lungs at the end of expiratory limbs to an average value that no longer required him to draw on expiratory reserve volume
PMID: 2072676
ISSN: 0022-4685
CID: 97946
Cochlear implants
Chapter by: Svirsky MA; Cullen JK; Walker CF
in: Bioinstrumentation : research, developments, and applications by Wise DL [Eds]
Boston : Butterworths, 1990
pp. 1161-1193
ISBN: 0409902349
CID: 5010
AN ALTERNATIVE WAY TO ENCODE VOICING IN MULTICHANNEL COCHLEAR IMPLANTS
Chapter by: SVIRSKY, MA; FEINMAN, GR; CULLEN, JK; WALKER, CF
in: Proceedings Of The Annual International Conference Of The Ieee Engineering In Medicine And Biology Society, Pts 1-4 by Harris, G; Walker, C [Eds]
pp. 1541-1542
ISBN:
CID: 2349812
DISCRIMINATION OF COMPLEX SPEECH-RELATED SIGNALS WITH A MULTICHANNEL ELECTRONIC COCHLEAR IMPLANT AS MEASURED BY ADAPTIVE PROCEDURES
HOOD, LJ; SVIRSKY, MA; CULLEN, JK
ISI:A1987G162500016
ISSN: 0003-4894
CID: 97911