Searched for: in-biosketch:yes
person:carrr01
Multifocal electroretinography as a function of age: the importance of normative values for older adults
Seiple, William; Vajaranant, Thasarat S; Szlyk, Janet P; Clemens, Colleen; Holopigian, Karen; Paliga, Jennifer; Badawi, David; Carr, Ronald E
PURPOSE: To determine the influence of age on local electroretinographic responses in humans. METHODS: Multifocal electroretinograms (mfERGs) were obtained from 62 normally sighted subjects ranging in age from 21 to 81 years. A stimulus array of 103 scaled hexagons was used to measure electrical signals within a retinal area approximately 46 degrees in diameter. Commonly reported mfERG methods were used to quantify the responses: peak-to-peak amplitudes and implicit times, scalar product amplitude, and amplitude and time scales derived from the algorithm of Hood and Li, published in 1997. RESULTS: Regression analysis showed significant linear relationships of amplitude and timing measures with age. The rates of losses were 10.5% per decade for peak-to-peak amplitude, 11.7% per decade for scalar product amplitude, and 9.5% per decade for a-scale. The rate of amplitude reduction was highest in the central 3 degrees. Age had less influence on implicit time measures. The rates of timing losses were 1.4% per decade for the N1 component and 1.0% per decade for both the P1 component and the t-scale measure. Using predicted interval ranges, the age was calculated at which 50% of the expected values would fall below the lower 95% prediction interval band of younger subjects. CONCLUSIONS: The age-associated mfERG alterations are presented to emphasize the importance of appropriate normative data in interpretation of mfERGs
PMID: 12657622
ISSN: 0146-0404
CID: 39262
Recommendations on screening for chloroquine and hydroxychloroquine retinopathy: a report by the American Academy of Ophthalmology [Guideline]
Marmor, Michael F; Carr, Ronald E; Easterbrook, Michael; Farjo, Ayad A; Mieler, William F
PMID: 12093666
ISSN: 0161-6420
CID: 92138
Local cone and rod system function in progressive cone dystrophy
Holopigian, Karen; Seiple, William; Greenstein, Vivienne C; Hood, Donald C; Carr, Ronald E
PURPOSE: To compare the patterns of local cone and rod system impairment in patients with progressive cone dystrophy (CD) using psychophysical and electrophysiological techniques. METHODS: Local cone system function was assessed by measuring cone system thresholds (visual fields) and cone-mediated multifocal electroretinograms (mfERGs). Rod system function was assessed by measuring rod system thresholds (visual fields) and rod-mediated mfERGs. The results in a group of eight patients with CD were compared with those in an age-similar control group. RESULTS: All the patients had abnormal cone system visual field thresholds and cone-mediated mfERGs. Cone system psychophysical thresholds were elevated for targets presented within the central 10 degrees, but were within normal limits for targets at peripheral locations. Cone-mediated mfERG measures of amplitude scale and time scale were abnormal for most of the hexagons tested. Most of the rod-mediated psychophysical thresholds and mfERGs were within normal limits. Rod system losses tended to be patchy and scattered throughout the area tested. CONCLUSIONS: There was poor correspondence among local measures of cone and rod system losses in these patients with CD. The results suggest that the spatial pattern of cone system losses in this disease differs from the spatial pattern of rod system losses
PMID: 12091439
ISSN: 0146-0404
CID: 39621
Test-retest reliability of psychophysical and electrophysiological perimetric measures in patients with retinitis pigmentosa [Meeting Abstract]
Clemens, CJ; Kirzhner, M; Holopigian, K; Seiple, W; Greenstein, VC; Carr, RE
ISI:000184606601126
ISSN: 0146-0404
CID: 55483
Relationships among luminance, acuity, contrast, and electrophysiological perimetry in patients with retinitis pigmentosa [Meeting Abstract]
Seiple, WH; Clemens, C; Holopigian, K; Greenstein, V; Carr, R
ISI:000184606601123
ISSN: 0146-0404
CID: 55482
A method for comparing psychophysical and multifocal electroretinographic increment thresholds
Seiple, William; Greenstein, Vivienne C; Holopigian, Karen; Carr, Ronald E; Hood, Donald C
The multifocal electroretinogram (mfERG) has been commonly used as a method for obtaining objective visual fields. Although qualitative comparisons have been good, quantitative comparisons between the results from mfERG and the results from Humphrey Visual Field Analyser (HVFA) have found variable degrees of agreement depending upon the mfERG response parameter examined and/or the disease studied. Lack of agreement may be due to differences in methodology, differences in the sites of response generation, and/or differences derived from comparing suprathreshold versus threshold responses. In addition, the two procedures are performed at different levels of adaptation. We developed an approach for matching stimulus parameters and compared mfERG and psychophysical thresholds to assess the effects of technique and level of adaptation on the two responses. Psychophysical and mfERG thresholds were obtained as a function of the adaptation level (1.5-4.0 log td) and retinal location. The derived increment threshold-versus-intensity functions for both measures were fitted using the equation logT=logT(0)+log((A+A(0))/A(0))(n). We found that the values of A(0) for the mfERG data were one log unit higher than those for the psychophysical data. In addition, the value of the slope (n) for the mfERG data was shallower (0.8) than that of the psychophysical data (1.0). Predictions were made about comparisons of HVFA threshold and mfERG amplitude data in patients with retinal disease based upon a two-site model of adaptation. The data for some groups of patients could be best-fitted with a model of a disease acting at a site distal to all gain changes, whereas data from other patients were best fitted with a model of a disease acting at a site proximal to all retinal gain. The relationship between the Humphrey visual field threshold losses and mfERG amplitude reductions depends upon the site and mechanism of a particular disease process and the model of retinal gain assumed. In no case is a one-to-one relationship between the losses in the two measures predicted
PMID: 11809478
ISSN: 0042-6989
CID: 39725
Sites of cone and rod system loss in patients with progressive cone dystrophy [Meeting Abstract]
Holopigian, K; Greenstein, VC; Wu, C; Seiple, W; Hood, DC; Carr, RE
ISI:000168392100383
ISSN: 0146-0404
CID: 54969
Local cone and rod system function in patients with retinitis pigmentosa
Holopigian K; Seiple W; Greenstein VC; Hood DC; Carr RE
PURPOSE. To compare local cone and rod system function in patients with retinitis pigmentosa (RP) using electrophysiological and psychophysical techniques. METHODS. Cone-mediated multifocal electroretinograms (M-ERGs), cone system threshold visual fields, rod-mediated M-ERGs, and rod system threshold visual fields were measured in seven patients with RP. RESULTS. All the patients had normal cone system visual field thresholds and normal cone-mediated M-ERG implicit times within the central 5 degrees. Both cone-mediated responses were abnormal at some peripheral retinal locations. There were significant correlations among cone system amplitude, timing, and visual field loss. All the patients had some retinal areas where the rod-mediated M-ERG amplitudes were not measurable. In areas where they were measurable, these rod-mediated M-ERG responses were often within normal limits for amplitude and timing. In contrast to the cone system data, there were no significant relationships between rod-mediated M-ERG measures and rod system threshold elevations. The cone and rod system psychophysical thresholds showed regional correspondence; the amplitude-scale and time-scale measures of the M-ERG did not. CONCLUSIONS. The results indicate that there was better local correspondence between psychophysical and electrophysiological measures in the cone system than in the rod system in patients with RP. In addition, the psychophysical measures of cone and rod system function showed better correspondence than did the electrophysiological measures
PMID: 11222541
ISSN: 0146-0404
CID: 26783
Retinal function in diabetic macular edema after focal laser photocoagulation
Greenstein VC; Chen H; Hood DC; Holopigian K; Seiple W; Carr RE
PURPOSE: To assess the effects of focal photocoagulation on retinal function in the macular and perimacular areas in patients with diabetes who have clinically significant macular edema. METHODS: Eleven patients were assessed after focal laser treatment. Multifocal electroretinogram (ERG) and full-field ERG techniques were used to evaluate the effects of treatment on macular, paramacular, and peripheral retinal function. A modified visual field technique was used to obtain local threshold fields. The posttreatment results were compared with pretreatment results. Changes in local ERG response amplitudes and implicit times were calculated for each patient and presented as difference fields. The changes in local ERG responses were compared with the changes in local field sensitivity. RESULTS: After treatment, the results of the psychophysical tests suggested little or no change in visual function, but changes in retinal function were observed with the multifocal ERG technique. Local ERG responses showed increases in implicit time and decreases in amplitude, compared with pretreatment values. Timing was affected more than amplitude. CONCLUSIONS: The results suggest that focal treatment produces changes in retinal function, and these changes are not restricted to the treated macular area
PMID: 11006264
ISSN: 0146-0404
CID: 39554
The nature and extent of retinal dysfunction associated with diabetic macular edema
Greenstein VC; Holopigian K; Hood DC; Seiple W; Carr RE
PURPOSE: To evaluate the nature and extent of retinal dysfunction in the macular and surrounding areas that occurs in patients with diabetes with clinically significant macular edema (CSME). METHODS: Eleven patients were evaluated before focal laser treatment. Multifocal electroretinogram (ERG) and full-field ERG techniques were used to assess the effects of diabetic retinopathy and CSME on macular, paramacular, and peripheral retinal function. A modified visual field technique was used to obtain local threshold fields. The relationship between local sensitivity changes and local ERG changes was determined. RESULTS: Local ERG responses were significantly delayed and decreased in amplitude, and timing changes were observed in a larger area of the retina than amplitude changes. Visual field deficits were similarly widespread with marked sensitivity losses occurring in retinal areas with normal ERG amplitudes and in areas that appeared to be free of fundus abnormalities. Despite this similarity and the finding that retinal areas with elevated thresholds have timing delays, timing delays were not good predictors of the degree of threshold elevation. CONCLUSIONS: The results demonstrate the widespread nature of timing deficits and visual field deficits that are associated with CSME
PMID: 11006263
ISSN: 0146-0404
CID: 39555