Try a new search

Format these results:

Searched for:

in-biosketch:yes

person:madelg01

Total Results:

68


CT-guided radiofrequency ablation for osteoid osteomas: a systematic review

Tordjman, Mickael; Perronne, Laetitia; Madelin, Guillaume; Mali, Rahul D; Burke, Christopher
OBJECTIVES/OBJECTIVE:CT-guided radiofrequency ablation (CT-RFA) is considered to be the gold standard for treatment of osteoid osteoma (OO) yet treatment failures (TFs) continue to be reported. This systematic review was conducted to evaluate factors associated with TF, such as ablation time, lesion location, and patient age as well as evaluating how TF has trended over time. METHODS:Original studies reporting on patients undergoing CT-RFA of OO published between 2002 and 2019 were identified. TF was defined as patients with (1) recurrent or persistent pain +/- (2) imaging evidence of persistent OO. TFs were subdivided into those occurring after the index procedure (primary TF) or those occurring after repeat RFA (secondary TF). Subgroup analysis was performed for TF based on the study date (2002-2010 or 2010-2019), time duration of ablation at 90 °C (6 min or > 6 min), patient age, and tumor location (spinal vs. appendicular). RESULTS:Sixty-nine studies were included for a total of 3023 patients. The global primary TF rate was 8.3% whereas the secondary TF rate was 3.1%. The TF rate reported in studies published after 2011(7%) was about half that during the earlier time period 2002-2010 (14%). There was no statistical difference in TF corrected for age, OO location, or duration of ablation (respectively p = 0.39, 0.13, and 0.23). The global complication rate was 3%, the most frequent being skin burns (n = 24; 0.7%). CONCLUSIONS:A decrease in TF observed between 2011-2019 compared to 2002-2010 may reflect improvements in operator technique or advancements in equipment. Duration of ablation, patient age, or location of OO failed to significantly correlate with TF. KEY POINTS/CONCLUSIONS:• CT-guided radiofrequency ablation of osteoid osteomas is a safe technique with a low rate of treatment failure (8.3% failure rate after the primary radiofrequency reducing to 3.1% following a secondary treatment). • The treatment failure rate has decreased over time, possibly due to an improved understanding of the disease process, better technique, and advances in equipment. • Duration of ablation, patient age, or lesion location did not significantly correlate with treatment failure.
PMID: 32518986
ISSN: 1432-1084
CID: 4489612

Diagnostic test accuracy of ADC values for identification of clear cell renal cell carcinoma: systematic review and meta-analysis

Tordjman, Mickael; Mali, Rahul; Madelin, Guillaume; Prabhu, Vinay; Kang, Stella K
OBJECTIVES/OBJECTIVE:To perform a systematic review on apparent diffusion coefficient (ADC) values of renal tumor subtypes and meta-analysis on the diagnostic performance of ADC for differentiation of localized clear cell renal cell carcinoma (ccRCC) from other renal tumor types. METHODS:Medline, Embase, and the Cochrane Library databases were searched for studies published until May 1, 2019, that reported ADC values of renal tumors. Methodological quality was evaluated. For the meta-analysis on diagnostic test accuracy of ADC for differentiation of ccRCC from other renal lesions, we applied a bivariate random-effects model and compared two subgroups of ADC measurement with vs. without cystic and necrotic areas. RESULTS:We included 48 studies (2588 lesions) in the systematic review and 13 studies (1126 lesions) in the meta-analysis. There was no significant difference in ADC of renal parenchyma using b values of 0-800 vs. 0-1000 (p = 0.08). ADC measured on selected portions (sADC) excluding cystic and necrotic areas differed significantly from whole-lesion ADC (wADC) (p = 0.002). Compared to ccRCC, minimal-fat angiomyolipoma, papillary RCC, and chromophobe RCC showed significantly lower sADC while oncocytoma exhibited higher sADC. Summary estimates of sensitivity and specificity to differentiate ccRCC from other tumors were 80% (95% CI, 0.76-0.88) and 78% (95% CI, 0.64-0.89), respectively, for sADC and 77% (95% CI, 0.59-0.90) and 77% (95% CI, 0.69-0.86) for wADC. sADC offered a higher area under the receiver operating characteristic curve than wADC (0.852 vs. 0.785, p = 0.02). CONCLUSIONS:ADC values of kidney tumors that exclude cystic or necrotic areas more accurately differentiate ccRCC from other renal tumor types than whole-lesion ADC values. KEY POINTS/CONCLUSIONS:• Selective ADC of renal tumors, excluding cystic and necrotic areas, provides better discriminatory ability than whole-lesion ADC to differentiate clear cell RCC from other renal lesions, with area under the receiver operating characteristic curve (AUC) of 0.852 vs. 0.785, respectively (p = 0.02). • Selective ADC of renal masses provides moderate sensitivity and specificity of 80% and 78%, respectively, for differentiation of clear cell renal cell carcinoma (RCC) from papillary RCC, chromophobe RCC, oncocytoma, and minimal-fat angiomyolipoma. • Selective ADC excluding cystic and necrotic areas are preferable to whole-lesion ADC as an additional tool to multiphasic MRI to differentiate clear cell RCC from other renal lesions whether the highest b value is 800 or 1000.
PMID: 32144458
ISSN: 1432-1084
CID: 4340972

Simultaneous proton magnetic resonance fingerprinting and sodium MRI

Yu, Zidan; Madelin, Guillaume; Sodickson, Daniel K; Cloos, Martijn A
PURPOSE/OBJECTIVE:, and proton density) and sodium density images in 1 single scan. We hope that the development of such capabilities will help to ease the implementation of sodium MRI in clinical trials and provide more opportunities for researchers to investigate metabolism through sodium MRI. METHODS: RESULTS: CONCLUSIONS:
PMID: 31746048
ISSN: 1522-2594
CID: 4195442

A dual-tuned 17 O/1 H head array for direct brain oximetry at 3 Tesla

Lakshmanan, Karthik; Dehkharghani, Seena; Madelin, Guillaume; Brown, Ryan
PURPOSE/OBJECTIVE:H coil for direct brain oximetry at 3T. METHODS:H images. RESULTS:H structural brain images demonstrated excellent quality and anatomical detail using routine clinical imaging sequence parameters and parallel acceleration. CONCLUSION/CONCLUSIONS:H imaging under standard clinical 3 T scanning conditions.
PMID: 31593372
ISSN: 1522-2594
CID: 4129612

Multinuclear Absolute MR Thermometry [PrePrint]

Silletta, Emilia; Jerschow, Alexej; Madelin, Guillaume; Alon, Leeor
ORIGINAL:0014923
ISSN: 2331-8422
CID: 4774172

Multinuclear absolute magnetic resonance thermometry

Silletta, Emilia V; Jerschow, Alexej; Madelin, Guillaume; Alon, Leeor
Non-invasive measurement of absolute temperature is important for proper characterization of various pathologies and for evaluation of thermal dose during interventional procedures. The proton (hydrogen nucleus) magnetic resonance (MR) frequency shift method can be used to map relative temperature changes. However, spatiotemporal variations in the main magnetic field and the lack of local internal frequency reference challenge the determination of absolute temperature. Here, we introduce a multinuclear method for absolute MR thermometry, based on the fact that the hydrogen and sodium nuclei exhibit a unique and distinct characteristic frequency dependence with temperature and with electrolyte concentration. A one-to-one mapping between the precession frequency difference of the two nuclei and absolute temperature is demonstrated. Proof-of-concept experiments were conducted in aqueous solutions with different NaCl concentrations, in agarose gel samples, and in freshly excised ex vivo mouse tissues. One-dimensional chemical shift imaging experiments also demonstrated excellent agreement with infrared measurements.
PMCID:7561043
PMID: 33072888
ISSN: 2399-3650
CID: 4637232

A dual-tuned O-17/H-1 head array for direct brain oximetry at 3 Tesla

Lakshmanan, Karthik; Dehkharghani, Seena; Madelin, Guillaume; Brown, Ryan
ISI:000489237500001
ISSN: 0740-3194
CID: 4155922

A dual-tuned multichannel bilateral RF coil for 1 H/23 Na breast MRI at 7 T

Ianniello, Carlotta; Madelin, Guillaume; Moy, Linda; Brown, Ryan
PURPOSE/OBJECTIVE:Sodium MRI has shown promise for monitoring neoadjuvant chemotherapy response in breast cancer. The purpose of this work was to build a dual-tuned bilateral proton/sodium breast coil for 7T MRI that provides sufficient SNR to enable sodium breast imaging in less than 10 minutes. METHODS:The proton/sodium coil consists of 2 shielded unilateral units: 1 for each breast. Each unit consists of 3 nested layers: (1) a 3-loop solenoid for sodium excitation, (2) a 3-loop solenoid for proton excitation and signal reception, and (3) a 4-channel receive array for sodium signal reception. Benchmark measurements were performed in phantoms with and without the sodium receive array insert. In vivo images were acquired on a healthy volunteer. RESULTS:The sodium receive array boosted 1.5 to 3 times the SNR compared with the solenoid. Proton SNR loss due to residual interaction with the sodium array was less than 10%. The coil enabled sodium imaging in vivo with 2.8-mm isotropic nominal resolution (~5-mm real resolution) in 9:36 minutes. CONCLUSION/CONCLUSIONS:The coil design that we propose addresses challenges associated with sodium's low SNR from a hardware perspective and offers the opportunity to investigate noninvasively breast tumor metabolism as a function of sodium concentration in patients undergoing neoadjuvant chemotherapy.
PMCID:6626555
PMID: 31148249
ISSN: 1522-2594
CID: 4000212

Precisely-Measured Hydration Status Correlates with Hippocampal Volume in Healthy Older Adults [Letter]

Butler, Tracy; Deshpande, Anup; Harvey, Patrick; Li, Yi; Rusinek, Henry; Pirraglia, Elizabeth; Osorio, Ricardo S; Glodzik, Lidia; de Leon, Mony J; Madelin, Guillaume; Yu, Wen W; Gallagher, Dympna; Masaeka, John
PMID: 30879941
ISSN: 1545-7214
CID: 3734792

Exploration of New Contrasts, Targets, and MR Imaging and Spectroscopy Techniques for Neuromuscular Disease - A Workshop Report of Working Group 3 of the Biomedicine and Molecular Biosciences COST Action BM1304 MYO-MRI

Strijkers, Gustav J; Araujo, Ericky C A; Azzabou, Noura; Bendahan, David; Blamire, Andrew; Burakiewicz, Jedrek; Carlier, Pierre G; Damon, Bruce; Deligianni, Xeni; Froeling, Martijn; Heerschap, Arend; Hollingsworth, Kieren G; Hooijmans, Melissa T; Karampinos, Dimitrios C; Loudos, George; Madelin, Guillaume; Marty, Benjamin; Nagel, Armin M; Nederveen, Aart J; Nelissen, Jules L; Santini, Francesco; Scheidegger, Olivier; Schick, Fritz; Sinclair, Christopher; Sinkus, Ralph; de Sousa, Paulo L; Straub, Volker; Walter, Glenn; Kan, Hermien E
Neuromuscular diseases are characterized by progressive muscle degeneration and muscle weakness resulting in functional disabilities. While each of these diseases is individually rare, they are common as a group, and a large majority lacks effective treatment with fully market approved drugs. Magnetic resonance imaging and spectroscopy techniques (MRI and MRS) are showing increasing promise as an outcome measure in clinical trials for these diseases. In 2013, the European Union funded the COST (co-operation in science and technology) action BM1304 called MYO-MRI (www.myo-mri.eu), with the overall aim to advance novel MRI and MRS techniques for both diagnosis and quantitative monitoring of neuromuscular diseases through sharing of expertise and data, joint development of protocols, opportunities for young researchers and creation of an online atlas of muscle MRI and MRS. In this report, the topics that were discussed in the framework of working group 3, which had the objective to: Explore new contrasts, new targets and new imaging techniques for NMD are described. The report is written by the scientists who attended the meetings and presented their data. An overview is given on the different contrasts that MRI can generate and their application, clinical needs and desired readouts, and emerging methods.
PMID: 30714967
ISSN: 2214-3599
CID: 3631932