Try a new search

Format these results:

Searched for:

in-biosketch:yes

person:babbj01

Total Results:

548


Relationship between knee alignment and T1rho values of articular cartilage and menisci in patients with knee osteoarthritis

Wang, Ligong; Vieira, Renata La Rocca; Rybak, Leon D; Babb, James S; Chang, Gregory; Krasnokutsky, Svetlana; Abramson, Steven; Regatte, Ravinder
OBJECTIVE: To assess the relationship between knee alignment and subregional T1rho values of the femorotibial cartilage and menisci in patients with mild (Kellgren-Lawrence grade 1) to moderate (KL3) osteoarthritis (OA) at 3T. MATERIALS AND METHODS: 26 subjects with a clinical diagnosis of KL1-3 OA were included and subdivided into three subgroups: varus, valgus, and neutral. All subjects were evaluated on a 3T MR scanner. Mann-Whitney and Wilcoxon signed rank tests were performed to determine any statistically significant differences in subregional T1rho values of femorotibial cartilage and menisci among the three subgroups of KL1-3 OA patients. RESULTS: Medial femoral anterior cartilage subregion in varus group had significantly higher (p<0.05) T1rho values than all cartilage subregions in valgus group. Medial tibial central cartilage subregion had significantly higher T1rho values (p<0.05) than lateral tibial central cartilage subregion in varus group. The posterior horn of the medial meniscus in neutral group had significantly higher T1rho values (p<0.0029) than all meniscus subregions in valgus group. CONCLUSION: There exists some degree of association between knee alignment and subregional T1rho values of femorotibial cartilage and menisci in patients with clinical OA.
PMCID:3795827
PMID: 23769189
ISSN: 0720-048x
CID: 426082

Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla

Brown, Ryan; Storey, Pippa; Geppert, Christian; McGorty, Kellyanne; Leite, Ana Paula Klautau; Babb, James; Sodickson, Daniel K; Wiggins, Graham C; Moy, Linda
OBJECTIVES: To evaluate the image quality of T1-weighted fat-suppressed breast MRI at 7 T and to compare 7-T and 3-T images. METHODS: Seventeen subjects were imaged using a 7-T bilateral transmit-receive coil and 3D gradient echo sequence with adiabatic inversion-based fat suppression (FS). Images were graded on a five-point scale and quantitatively assessed through signal-to-noise ratio (SNR), fibroglandular/fat contrast and signal uniformity measurements. RESULTS: Image scores at 7 and 3 T were similar on standard-resolution images (1.1 x 1.1 x 1.1-1.6 mm(3)), indicating that high-quality breast imaging with clinical parameters can be performed at 7 T. The 7-T SNR advantage was underscored on 0.6-mm isotropic images, where image quality was significantly greater than at 3 T (4.2 versus 3.1, P
PMCID:4036120
PMID: 23896763
ISSN: 0938-7994
CID: 571412

Computed diffusion-weighted imaging of the prostate at 3 T: impact on image quality and tumour detection

Rosenkrantz, Andrew B; Chandarana, Hersh; Hindman, Nicole; Deng, Fang-Ming; Babb, James S; Taneja, Samir S; Geppert, Christian
OBJECTIVES: To investigate the impact of prostate computed diffusion-weighted imaging (DWI) on image quality and tumour detection. METHODS: Forty-nine patients underwent 3-T magnetic resonance imaging using a pelvic phased-array coil before prostatectomy, including DWI with b values of 50 and 1,000 s/mm(2). Computed DW images with b value 1,500 s/mm(2) were generated from the lower b-value images. Directly acquired b-1,500 DW images were obtained in 39 patients. Two radiologists independently assessed DWI for image quality measures and location of the dominant lesion. A third radiologist measured tumour-to-peripheral-zone (PZ) contrast. Pathological findings from prostatectomy served as the reference standard. RESULTS: Direct and computed b-1,500 DWI showed better suppression of benign prostate tissue than direct b-1,000 DWI for both readers (P /= 0.180). Tumour-to-PZ contrast was greater on computed b-1,500 than on either direct DWI set (P < 0.001). CONCLUSION: Computed DWI of the prostate using b value >/=1,000 s/mm(2) improves image quality and tumour detection compared with acquired standard b-value images. KEY POINTS: * Diffusion weighted MRI is increasingly used for diagnosing and assessing prostate carcinoma. * Prostate computed DWI can extrapolate high b-value images from lower b values. * Computed DWI provides greater suppression of benign tissue than lower b-value images. * Computed DWI provides less distortion and artefacts than images using same b value. * Computed DWI provides better diagnostic performance than lower b-value images.
PMID: 23756956
ISSN: 0938-7994
CID: 573582

Prostate Cancer Localization Using Multiparametric MR Imaging: Comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert Scales

Rosenkrantz, Andrew B; Kim, Sooah; Lim, Ruth P; Hindman, Nicole; Deng, Fang-Ming; Babb, James S; Taneja, Samir S
Purpose: To compare the recently proposed Prostate Imaging Reporting and Data System (PI-RADS) scale that incorporates fixed criteria and a standard Likert scale based on overall impression in prostate cancer localization using multiparametric magnetic resonance (MR) imaging. Materials and Methods: This retrospective study was HIPAA compliant and institutional review board approved. Seventy patients who underwent 3-T pelvic MR imaging, including T2-weighted imaging, diffusion-weighted imaging, and dynamic contrast material-enhanced imaging, with a pelvic phased-array coil before radical prostatectomy were included. Three radiologists, each with 6 years of experience, independently scored 18 regions (12 peripheral zone [PZ], six transition zone [TZ]) using PI-RADS (range, scores 3-15) and Likert (range, scores 1-5) scales. Logistic regression for correlated data was used to compare scales for detection of tumors larger than 3 mm in maximal diameter at prostatectomy. Results: Maximal accuracy was achieved with score thresholds of 8 and higher and of 3 and higher for PI-RADS and Likert scales, respectively. At these thresholds, in the PZ, similar accuracy was achieved with the PI-RADS scale and the Likert scale for radiologist 1 (89.0% vs 88.2%, P = .223) and radiologist 3 (88.5% vs 88.2%, P = .739) and greater accuracy was achieved with the PI-RADS scale than the Likert scale for radiologist 2 (89.6% vs 87.1%, P = .008). In the TZ, accuracy was lower with the PI-RADS scale than with the Likert scale for radiologist 1 (70.0% vs 87.1%, P < .001), radiologist 2 (87.6% vs 92.6%, P = .002), and radiologist 3 (82.9% vs 91.2%, P < .001). For tumors with Gleason score of at least 7, sensitivity was higher with the PI-RADS scale than with the Likert scale for radiologist 1 (88.6% vs 82.6%, P = .032), and sensitivity was similar for radiologist 2 (78.0% vs 76.5, P = .467) and radiologist 3 (77.3% vs 81.1%, P = .125). Conclusion: Radiologists performed well with both PI-RADS and Likert scales for tumor localization, although, in the TZ, performance was better with the Likert scale than the PI-RADS scale. (c) RSNA, 2013 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122233/-/DC1.
PMID: 23788719
ISSN: 0033-8419
CID: 586172

Novel White Matter Tract Integrity Metrics Sensitive to Alzheimer Disease Progression

Fieremans, E; Benitez, A; Jensen, J H; Falangola, M F; Tabesh, A; Deardorff, R L; Spampinato, M V S; Babb, J S; Novikov, D S; Ferris, S H; Helpern, J A
BACKGROUND AND PURPOSE:Along with cortical abnormalities, white matter microstructural changes such as axonal loss and myelin breakdown are implicated in the pathogenesis of Alzheimer disease. Recently, a white matter model was introduced that relates non-Gaussian diffusional kurtosis imaging metrics to characteristics of white matter tract integrity, including the axonal water fraction, the intra-axonal diffusivity, and the extra-axonal axial and radial diffusivities.MATERIALS AND METHODS:This study reports these white matter tract integrity metrics in subjects with amnestic mild cognitive impairment (n = 12), Alzheimer disease (n = 14), and age-matched healthy controls (n = 15) in an effort to investigate their sensitivity, diagnostic accuracy, and associations with white matter changes through the course of Alzheimer disease.RESULTS:With tract-based spatial statistics and region-of-interest analyses, increased diffusivity in the extra-axonal space (extra-axonal axial and radial diffusivities) in several white matter tracts sensitively and accurately discriminated healthy controls from those with amnestic mild cognitive impairment (AUC = 0.82-0.95), while widespread decreased axonal water fraction discriminated amnestic mild cognitive impairment from Alzheimer disease (AUC = 0.84). Additionally, these white matter tract integrity metrics in the body of the corpus callosum were strongly correlated with processing speed in amnestic mild cognitive impairment (r = |0.80-0.82|, P < .001).CONCLUSIONS:These findings have implications for the course and spatial progression of white matter degeneration in Alzheimer disease, suggest the mechanisms by which these changes occur, and demonstrate the viability of these white matter tract integrity metrics as potential neuroimaging biomarkers of the earliest stages of Alzheimer disease and disease progression.
PMCID:3962262
PMID: 23764722
ISSN: 0195-6108
CID: 620202

Structure-specific glial response in a macaque model of neuroAIDS: multivoxel proton magnetic resonance spectroscopic imaging at 3 Tesla

Wu, William E; Tal, Assaf; Zhang, Ke; Babb, James S; Ratai, Eva-Maria; Gonzalez, R Gilberto; Gonen, Oded
OBJECTIVE:: As approximately 40% of persons with HIV also suffer neurocognitive decline, we sought to assess metabolic dysfunction in the brains of simian immunodeficiency virus (SIV)-infected rhesus macaques, an advanced animal model, in structures involved in cognitive function. We test the hypothesis that SIV-infection produces proton-magnetic resonance spectroscopic imaging (H-MRSI)-observed decline in the neuronal marker, N-acetylaspartate (NAA), and elevations in the glial marker, myo-inositol (mI), and associated creatine (Cr) and choline (Cho) in these structures. DESIGN:: Pre- and 4-6 weeks post-SIV infection (with CD8 T-lymphocyte depletion) was monitored with T2-weighted quantitative MRI and 16 x 16 x 4 multivoxel H-MRSI (TE/TR = 33/1400 ms) in the brains of five rhesus macaques. METHODS:: Exploiting the high-resolution H-MRSI grid, we obtained absolute, cerebrospinal fluid partial volume-corrected NAA, Cr, Cho and mI concentrations from centrum semiovale, caudate nucleus, putamen, thalamus and hippocampus regions. RESULTS:: Pre- to post-infection mean Cr increased in the thalamus: 7.2 +/- 0.4 to 8.0 +/- 0.8 mmol/l (+11%, P < 0.05); mI increased in the centrum semiovale: 5.1 +/- 0.8 to 6.6 +/- 0.8 mmol/l, caudate: 5.7 +/- 0.7 to 7.3 +/- 0.5 mmol/l, thalamus: 6.8 +/- 0.8 to 8.5 +/- 0.8 mmol/l and hippocampus: 7.7 +/- 1.2 to 9.9 +/- 0.4 mmol/l (+29%, +27%, +24% and +29%, all P < 0.05). NAA and Cho changes were not significant. CONCLUSION:: SIV-infection appears to cause brain injury indirectly, through glial activation, while the deep gray matter structures' neuronal cell bodies are relatively spared. Treatment regimens to reduce gliosis may, therefore, prevent neuronal damage and its associated neurocognitive impairment.
PMID: 23939235
ISSN: 0269-9370
CID: 570912

Relative distribution of pertinent findings on portable neonatal abdominal radiographs: can we shield the gonads?

Winfeld, Matthew; Strubel, Naomi; Pinkney, Lynne; Lala, Shailee; Milla, Sarah; Babb, James; Fefferman, Nancy
BACKGROUND: Shielding of the gonads is a dose-saving strategy in pediatric radiography and its use is the law in New York and the majority of other states. However, routine use of gonadal shields is controversial because of concerns that important diagnostic information can be obscured. OBJECTIVE: The purpose of this study was to assess the frequency and spatial distribution of key findings on portable neonatal abdominal radiographs. MATERIALS AND METHODS: We reviewed the 2,544 portable neonatal intensive care unit anteroposterior abdominal radiographs performed in 2010 at a university medical center, of which 962 were inadequately shielded. These 962 radiographs were reviewed by pairs of pediatric radiologists for the presence of findings in different regions, including bowel abnormalities, pneumatosis, free air, inguinal hernias, osseous abnormalities, and catheter/tube tips. RESULTS: The fewest pertinent findings were present below the level of the sacrosciatic notches (n = 181, 18.8%). Of the 853 abnormalities below the level of the iliac crests in our cohort, six were isolated to these regions, whereas others had concomitant abnormalities more superiorly. Of 35 radiographs with pneumatosis or suspected pneumatosis in the pelvis, 33 had pneumatosis in more superior regions. Suspected free air was never isolated to the pelvis. Osseous abnormalities were only present in the pelvis below the sacrosciatic notch, and 37.5% of lower extremity catheters terminated below the level of the sacrosciatic notches. CONCLUSION: Pertinent findings on neonatal intensive care unit abdominal radiographs are rarely isolated to the pelvic regions.
PMID: 23636540
ISSN: 0301-0449
CID: 542632

Dynamic contrast-enhanced magnetic resonance imaging measurement of renal function in patients undergoing partial nephrectomy: preliminary experience

Kang, Stella K; Huang, William C; Wong, Samson; Zhang, Jeff L; Stifelman, Michael D; Bruno, Mary T; Babb, James S; Lee, Vivian S; Chandarana, Hersh
OBJECTIVES: To evaluate changes in single-kidney glomerular filtration rate (SK-GFR) using low-dose dynamic contrast-enhanced magnetic resonance (MR) renography (MRR) in patients undergoing partial nephrectomy for renal masses. MATERIALS AND METHODS: In this Health Information Patient Protection Act-compliant prospective study, 18 patients with renal masses underwent preoperative MR imaging at 1.5 T for renal mass evaluation and low-dose gadolinium-enhanced MRR. Magnetic resonance renography was repeated approximately 48 to 72 hours and 6 months after partial nephrectomy. Single-kidney glomerular filtration rate was calculated from the MRR images, and the right and left kidney values were summed for total MR-GFR. Postoperative changes in SK-GFR and MR-GFR were compared with changes in estimated glomerular filtration rate calculated using modification of diet in renal disease formula, renal lesion characteristics, ischemia type (warm vs cold), and ischemia time. RESULTS: A decrease in the operated kidney SK-GFR was seen in 15 of the 18 patients, with a mean (SD) loss of 31% (23%), whereas estimated glomerular filtration rate decreased in 13 of the 18 patients with mean (SD) decrease of 19% (14%). Decrease in SK-GFR was greatest in the patients with warm ischemia time greater than 40 minutes and least in the patients with cold ischemia. In the immediate postoperative period, 6 of 7 patients (86%) with preoperative MR-GFR less than 60 mL/min per 1.73 m failed to demonstrate compensatory increase in SK-GFR in the nonoperated kidney, whereas 5 of 11 patients with baseline MR-GFR more than 60 mL/min per 1.73 m showed compensatory increase in nonoperated kidney SK-GFR. CONCLUSIONS: Magnetic resonance renography can demonstrate functional loss in the operated kidney and compensatory increase in the function of the contralateral kidney, thus enabling evaluation of various surgical techniques on kidney function.
PMCID:3766451
PMID: 23669587
ISSN: 0020-9996
CID: 519372

Utility of diffusional kurtosis imaging as a marker of adverse pathologic outcomes among prostate cancer active surveillance candidates undergoing radical prostatectomy

Rosenkrantz, Andrew B; Prabhu, Vinay; Sigmund, Eric E; Babb, James S; Deng, Fang-Ming; Taneja, Samir S
OBJECTIVE. The purpose of this study was to compare findings at nongaussian diffusional kurtosis imaging and conventional diffusion-weighted MRI as markers of adverse pathologic outcomes among prostate cancer patients who are active surveillance candidates and choose to undergo prostatectomy. MATERIALS AND METHODS. Fifty-eight active surveillance candidates (prostate-specific antigen concentration, < 10 ng/mL; clinical tumor category less than T2a; Gleason score, 3 + 3;
PMID: 24059373
ISSN: 0361-803x
CID: 542842

Comparison of interreader reproducibility of the prostate imaging reporting and data system and likert scales for evaluation of multiparametric prostate MRI

Rosenkrantz, Andrew B; Lim, Ruth P; Haghighi, Mershad; Somberg, Molly B; Babb, James S; Taneja, Samir S
OBJECTIVE. The objective of our study was to compare interreader reproducibility of the recently proposed "Prostate Imaging Reporting and Data System," or "PI-RADS," scale incorporating fixed criteria and a standard Likert scale based on overall impression for prostate cancer localization using multiparametric MRI. MATERIALS AND METHODS. Fifty-five patients who underwent a 3-T prostate MRI examination using a pelvic phased-array coil and incorporating T2-weighted imaging, diffusion-weighted imaging, and dynamic contrast-enhanced imaging were included in the study. Three radiologists (6, 4, and 1 year of experience) independently scored 18 regions (12 in the peripheral zone [PZ] and six in the transition zone [TZ]) using PI-RADS (range, 3-15) and Likert (range, 1-5) scales, which were based on fixed criteria and overall impression, respectively. Interreader reproducibility was evaluated using the concordance correlation coefficient (CCC), which assesses exact agreement between scores (minimal, < 0.2; poor, 0.2-<0.4; moderate, 0.4-<0.6; strong, 0.6-<0.8; almost perfect, >/= 0.8). RESULTS. Agreement between experienced readers was strong in the PZ and TZ combined and in the PZ for both the PI-RADS and Likert scales (CCC = 0.608-0.677), moderate in the TZ for the Likert scale (CCC = 0.519), and poor in the TZ for PI-RADS (CCC = 0.376). Agreement between experienced and inexperienced readers was moderate to poor in the PZ and TZ combined for PI-RADS (CCC = 0.340-0.477), moderate in the PZ and TZ combined for the Likert scale (CCC = 0.471-0.497), moderate in the PZ for PI-RADS and Likert scales (CCC = 0.472-0.542), minimal to poor in the TZ for PI-RADS (CCC = 0.094-0.283), and poor in the TZ for the Likert scale (CCC = 0.287-0.400). CONCLUSION. Interreader reproducibility tended to be higher for relatively experienced readers than for less experienced readers and to be higher in the PZ than in the TZ. For the relatively experienced readers, reproducibility was similar for PI-RADS and Likert scales in the PZ but was somewhat higher for the Likert scale than for PI-RADS in the TZ.
PMID: 24059400
ISSN: 0361-803x
CID: 542852