Searched for: in-biosketch:yes
person:pc92
Bone Healing Around Dental Implants: Simplified vs Conventional Drilling Protocols at Speed of 400 rpm
Gil, Luiz Fernando; Sarendranath, Alvin; Neiva, Rodrigo; Marao, Heloisa F; Tovar, Nick; Bonfante, Estevam A; Janal, Malvin N; Castellano, Arthur; Coelho, Paulo G
PURPOSE: This study evaluated whether simplified drilling protocols would provide comparable histologic and histomorphometric results to conventional drilling protocols at a low rotational speed. MATERIALS AND METHODS: A total of 48 alumina-blasted and acid-etched Ti-6Al-4V implants with two diameters (3.75 and 4.2 mm, n = 24 per group) were bilaterally placed in the tibiae of 12 dogs, under a low-speed protocol (400 rpm). Within the same diameter group, half of the implants were inserted after a simplified drilling procedure (pilot drill + final diameter drill), and the other half were placed using the conventional drilling procedure. After 3 and 5 weeks, the animals were euthanized, and the retrieved bone-implant samples were subjected to nondecalcified histologic sectioning. Histomorphology, bone-to-implant contact (BIC), and bone area fraction occupancy (BAFO) analysis were performed. RESULTS: Histology showed that new bone was formed around implants, and inflammation or bone resorption was not evident for both groups. Histomorphometrically, when all independent variables were collapsed over drilling technique, no differences were detected for BIC and BAFO; when drilling technique was analyzed as a function of time, the conventional groups reached statistically higher BIC and BAFO at 3 weeks, but comparable values between techniques were observed at 5 weeks; 4.2-mm implants obtained statistically higher BAFO relative to 3.75-mm implants. CONCLUSION: Based on the present methodology, the conventional technique improved bone formation at 3 weeks, and narrower implants were associated with less bone formation.
PMID: 28291851
ISSN: 1942-4434
CID: 2528702
Early Healing Evaluation of Commercially Pure Titanium and Ti-6Al-4V Presenting Similar Surface Texture: An In Vivo Study
Castellano, Arthur; Gil, Luiz F; Bonfante, Estevam A; Tovar, Nick; Neiva, Rodrigo; Janal, Malvin N; Coelho, Paulo G
OBJECTIVE: This study evaluated the osseointegration of commercially pure titanium (Ti) grade-2 (G2) and Ti-6Al-4V alloy (G5) implants with the same geometry and surface treatment. MATERIALS AND METHODS: Thirty-six dental implants with a grit-blasted acid-etched surface were used (n = 18, each). Two implants, one per group, were installed in each subject, in the radius diaphysis (n = 18 beagle dogs), with interchanged fixture position (proximal-distal) between animals for a balanced number of devices per group and time in vivo (1, 3, and 6 weeks). RESULTS: Similar topographical parameters between G2 and G5 were observed for average surface roughness, root mean square, developed surface ratio, maximum height of surface, and density of summits. Removal torque was significantly higher for G5 than for G2. No differences were observed for bone-to-implant contact and bone-area-fraction occupancy. Removal torque significantly increased with time for both groups. At 1 week, new bone formation in direct contact with the implant surface and osteogenic tissue migration was observed with an increase in woven bone formation at 3 weeks followed by the onset of lamellar bone formation at 6 weeks. CONCLUSION: Although both surfaces were biocompatible and osteoconductive, increased removal torque was observed for Ti-6Al-4V compared with commercially pure Ti implants.
PMID: 28406881
ISSN: 1538-2982
CID: 2528522
Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis
Bordin, Dimorvan; Bergamo, Edmara T P; Fardin, Vinicius P; Coelho, Paulo G; Bonfante, Estevam A
PURPOSE: To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters. MATERIALS AND METHODS: For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (O3.3x10mm) and extra-narrow (O2.9x10mm) (21 per group). Identical abutments were torqued to the implants and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves, and reliability for a mission of 50,000 and 100,000 cycles at 50N, 100, 150 and 180N were calculated. For the finite element analysis (FEA), two virtual models, simulating the samples tested in fatigue, were constructed. Loading at 50N and 100N were applied 30 degrees off-axis at the crown. The von-Mises stress was calculated for implant and abutment. RESULTS: The beta (beta) values were: 0.67 for narrow and 1.32 for extra-narrow implants, indicating that failure rates did not increase with fatigue in the former, but more likely were associated with damage accumulation and wear-out failures in the latter. Both groups showed high reliability (up to 97.5%) at 50 and 100N. A decreased reliability was observed for both groups at 150 and 180N (ranging from 0 to 82.3%), but no significant difference was observed between groups. Failure predominantly involved abutment fracture for both groups. FEA at 50N-load, O3.3mm showed higher von-Mises stress for abutment (7.75%) and implant (2%) when compared to the O2.9mm. CONCLUSIONS: There was no significant difference between narrow and extra-narrow implants regarding probability of survival. The failure mode was similar for both groups, restricted to abutment fracture.
PMID: 28365541
ISSN: 1878-0180
CID: 2521762
Store-operated Ca2+ entry controls ameloblast cell function and enamel development
Eckstein, Miriam; Vaeth, Martin; Fornai, Cinzia; Vinu, Manikandan; Bromage, Timothy G; Nurbaeva, Meerim K; Sorge, Jessica L; Coelho, Paulo G; Idaghdour, Youssef; Feske, Stefan; Lacruz, Rodrigo S
Loss-of-function mutations in stromal interaction molecule 1 (STIM1) impair the activation of Ca2+ release-activated Ca2+ (CRAC) channels and store-operated Ca2+ entry (SOCE), resulting in a disease syndrome called CRAC channelopathy that is characterized by severe dental enamel defects. The cause of these enamel defects has remained unclear given a lack of animal models. We generated Stim1/2K14cre mice to delete STIM1 and its homolog STIM2 in enamel cells. These mice showed impaired SOCE in enamel cells. Enamel in Stim1/2K14cre mice was hypomineralized with decreased Ca content, mechanically weak, and thinner. The morphology of SOCE-deficient ameloblasts was altered, showing loss of the typical ruffled border, resulting in mislocalized mitochondria. Global gene expression analysis of SOCE-deficient ameloblasts revealed strong dysregulation of several pathways. ER stress genes associated with the unfolded protein response were increased in Stim1/2-deficient cells, whereas the expression of components of the glutathione system were decreased. Consistent with increased oxidative stress, we found increased ROS production, decreased mitochondrial function, and abnormal mitochondrial morphology in ameloblasts of Stim1/2K14cre mice. Collectively, these data show that loss of SOCE in enamel cells has substantial detrimental effects on gene expression, cell function, and the mineralization of dental enamel.
PMCID:5358480
PMID: 28352661
ISSN: 2379-3708
CID: 2508342
Microcomputed Tomography Evaluation of Polymerization Shrinkage of Class I Flowable Resin Composite Restorations
Sampaio, C S; Chiu, K-J; Farrokhmanesh, E; Janal, M; Puppin-Rontani, R M; Giannini, M; Bonfante, E A; Coelho, P G; Hirata, R
The present study aimed to characterize the pattern and volume of polymerization shrinkage of flowable resin composites, including one conventional, two bulk fill, and one self-adhesive. Standardized class I preparations (2.5 mm depth x 4 mm length x 4 mm wide) were performed in 24 caries-free human third molars that were randomly divided in four groups, according to the resin composite and adhesive system used: group 1 = Permaflo + Peak Universal Bond (PP); group 2 = Filtek Bulk Fill + Scotchbond Universal (FS); group 3 = Surefil SDR + XP Bond (SX); and group 4 = Vertise flow self-adhering (VE) (n=6). Each tooth was scanned three times using a microcomputed tomography (muCT) apparatus. The first scan was done after the cavity preparation, the second after cavity filling with the flowable resin composite before curing, and the third after it was cured. The muCT images were imported into three-dimensional rendering software, and volumetric polymerization shrinkage percentage was calculated for each sample. Data were submitted to one-way analysis of variance and post hoc comparisons. No significant difference was observed among PP, FS, and VE. SX bulk fill resin composite presented the lowest values of volumetric shrinkage. Shrinkage was mostly observed along the occlusal surface and part of the pulpal floor. In conclusion, polymerization shrinkage outcomes in a 2.5-mm deep class I cavity were material dependent, although most materials did not differ. The location of shrinkage was mainly at the occlusal surface.
PMID: 27689769
ISSN: 1559-2863
CID: 2451912
In Silico Analysis of the Biomechanical Stability of Commercially Pure Ti and Ti-15Mo Plates for the Treatment of Mandibular Angle Fracture
Yamaguchi, Satoshi; Anchieta, Rodolfo B; Guastaldi, Fernando P S; Tovar, Nick; Tawara, Daisuke; Imazato, Satoshi; Coelho, Paulo G
PURPOSE: To investigate the influence of different materials and fixation methods on maximum principal stress (MPS) and displacement in reconstruction plates using in silico 3-dimensional finite element analysis (3D-FEA). MATERIALS AND METHODS: Computer-assisted designed (CAD) models of the mandible and teeth were constructed. Champy and AO/ASIF plates and fixation screws were designed with CAD software. 3D-FEA was performed by image-based CAE software. Maximum and minimum values of biomechanical stability, MPS, and displacement distribution were compared in Champy and AO/ASIF plates made from commercially pure titanium grade 2 (cp-Ti) and a titanium-and-molybdenum (14.47% wt) alloy (Ti-15Mo). RESULTS: For plates fixed on a model of a fractured left angle of the mandible, the maximum and minimum values of MPS in the cp-Ti-constructed Champy plate, upper AO/ASIF plate, and lower AO/ASIF plate were 19.5 and 20.3%, 15.2 and 25.3%, and 21.4 and 4.6% lower, respectively, than those for plates made from Ti-15Mo. In the same model, the maximum and minimum values of displacement in the cp-Ti-constructed Champy plate, upper AO/ASIF plate, and lower AO/ASIF plate were 1.6 and 3.8%, 3.1 and 2.7%, and 5.4 and 10.4% higher, respectively, than those for plates made from Ti-15Mo. CONCLUSIONS: This in silico 3D-FEA shows that Ti-15Mo plates have greater load-bearing capability.
PMID: 28137635
ISSN: 1531-5053
CID: 2425222
Osseodensification for enhancement of spinal surgical hardware fixation
Lopez, Christopher D; Alifarag, Adham M; Torroni, Andrea; Tovar, Nick; Diaz-Siso, J Rodrigo; Witek, Lukasz; Rodriguez, Eduardo D; Coelho, Paulo G
Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4mm diameterx10mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p<0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p<0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation.
PMCID:5434975
PMID: 28113132
ISSN: 1878-0180
CID: 2418102
Bioactivity assessment of calcium phosphate coatings
Navarro Da Rocha, D; De Oliveira Cruz, LR; Mijares, DQ; Blazutti Març, RLS; De Campos, JB; Coelho, PG; Prado Da Silva, MH
Nowadays, bioactive coatings or modifications on titanium surface have been tested in vitro and in vivo. In this study, two types of calcium phosphate coatings were produced by a chemical deposition method and their bioactivity assay in cell culture medium were investigated. The calcium phosphate coatings were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy with field emission gun (FEG-SEM) analyses. Titanium substrate was successfully coated with brushite using chemical deposition method and, after a second step of conversion, the hydroxyapatite coating was obtained. The hydroxyapatite coating showed a bioactivity property after 14 days' incubation in McCoy medium culture
SCOPUS:85000962021
ISSN: 1013-9826
CID: 2402922
Temperature influence on the calcium phosphate coatings by chemical method
Navarro Da Rocha, D; De Oliveira Cruz, LR; Mijares, DQ; Blazutti Març, RLS; De Campos, JB; Coelho, PG; Prado Da Silva, MH
The increasing interest in the use of brushite and monetite as resorbable calcium phosphate cements or graft materials is related to the fact of these phases being metastable under physiological environment, with higher solubility than hydroxyapatite phase. In this study, X-ray diffraction (XRD) and scanning electron microscopy with field emission gun (FEG-SEM) analyses were performed in order to assess the temperature influence on the production of calcium phosphate coatings by a chemical deposition method. Titanium substrates were successfully coated with brushite and monetite by a chemical deposition method and a brushite-monetite transformation was assessed with the increasing temperature. Brushite deposition was kinetically favored at low temperatures, whereas monetite was the major phase at higher temperatures
SCOPUS:85000978414
ISSN: 1013-9826
CID: 2402912
Microcomputed Tomography Evaluation of Volumetric Shrinkage of Bulk-Fill Composites in Class II Cavities
Algamaiah, Hamad; Sampaio, Camila S; Rigo, Lindiane C; Janal, Malvin N; Giannini, Marcelo; Bonfante, Estevam A; Coelho, Paulo G; Reis, Andre F; Hirata, Ronaldo
PURPOSE: This study aimed to quantify polymerization shrinkage of one conventional and three bulk-fill composites, under bonded and unbonded conditions, in Class II preparations using 3D microcomputed tomography (muCT) and report its location. MATERIALS AND METHODS: Preparations (2.5 mm occlusal depth x 4 mm wide x 4 mm mesial box and 1 mm beyond the CEJ distal box depth) were made in 48 human extracted molars (n = 6). Four composites were tested, one regular (Vitalescence/VIT) and three bulk-fill: SureFil SDR Flow (SDR), Tetric EvoCeram Bulk Fill (TET), and Filtek flowable Bulk Fill (FIL). Teeth were divided into four groups according to restorative material used and subdivided into two subgroups, according to the presence of an adhesive system (XP Bond) application (bonded [-B]) or its absence (unbonded [-U]). Each tooth was scanned three times: (1) after cavity preparation, (2) before and (3) after composite light-curing. Acquired muCT images were imported into 2D and 3D software for analysis. RESULTS: Significantly different volumetric shrinkage between bonded and unbonded conditions was observed only for TET group (p < 0.05), unbonded presenting significantly higher volumetric shrinkage. Among the bonded groups, TET-B presented significantly lower shrinkage than both SDR-B and FIL-B but not significantly different from VIT-B. Generally, shrinkage occurred at occlusal and distal surfaces. CONCLUSIONS: When applied to bonded Class II cavities, TET exhibited significantly lower volumetric shrinkage compared to the other bulk-fill composites. However, it also exhibited the highest difference of volumetric shrinkage values between unbonded and bonded cavities. CLINICAL SIGNIFICANCE: Volumetric polymerization shrinkage occurred with all composites tested, regardless of material type (conventional or bulk-fill) or presence or absence of bonding. However, volumetric shrinkage has been reduced or at least maintained when bulk-fill composites were used compared to a conventional composite resin, which makes them a potential time saving alternative for clinicians. (J Esthet Restor Dent, 2016).
PMID: 27925387
ISSN: 1708-8240
CID: 2354472