Try a new search

Format these results:

Searched for:

in-biosketch:yes

person:babbj01

Total Results:

548


Global gray and white matter metabolic changes after simian immunodeficiency virus infection in CD8-depleted rhesus macaques: proton MRS imaging at 3 T

Wu, William E; Tal, Assaf; Kirov, Ivan I; Rusinek, Henry; Charytonowicz, Daniel; Babb, James S; Ratai, Eva-Maria; Gilberto Gonzalez, R; Gonen, Oded
To test the hypotheses that global decreased neuro-axonal integrity reflected by decreased N-acetylaspartate (NAA) and increased glial activation reflected by an elevation in its marker, the myo-inositol (mI), present in a CD8-depleted rhesus macaque model of HIV-associated neurocognitive disorders. To this end, we performed quantitative MRI and 16 x 16 x 4 multivoxel proton MRS imaging (TE/TR = 33/1400 ms) in five macaques pre- and 4-6 weeks post-simian immunodeficiency virus infection. Absolute NAA, creatine, choline (Cho), and mI concentrations, gray and white matter (GM and WM) and cerebrospinal fluid fractions were obtained. Global GM and WM concentrations were estimated from 224 voxels (at 0.125 cm(3) spatial resolution over ~35% of the brain) using linear regression. Pre- to post-infection global WM NAA declined 8%: 6.6 +/- 0.4 to 6.0 +/- 0.5 mM (p = 0.05); GM Cho declined 20%: 1.3 +/- 0.2 to 1.0 +/- 0.1 mM (p < 0.003); global mI increased 11%: 5.7 +/- 0.4 to 6.5 +/- 0.5 mM (p < 0.03). Global GM and WM brain volume fraction changes were statistically insignificant. These metabolic changes are consistent with global WM (axonal) injury and glial activation, and suggest a possible GM host immune response
PMCID:3784644
PMID: 23418159
ISSN: 0952-3480
CID: 231402

Glomerular filtration rate in evaluation of the effect of iodinated contrast media on renal function

Becker, Joshua; Babb, James; Serrano, Manuel
OBJECTIVE. The purpose of this study was to use measured glomerular filtration rate (GFR), the reference standard of renal function, to assess the deleterious effect of iodinated contrast media on renal function. Such an effect has been traditionally defined as a greater than 0.5-mg/dL increase in serum creatinine concentration or a 25% or greater increase 24-72 hours after the injection of iodinated contrast medium. SUBJECTS AND METHODS. This pilot investigation was focused on the consequences of clinically indicated IV injection of iodinated contrast media; intraarterial injection was excluded. One hundred thirteen patients with normal serum creatinine concentrations were enrolled in an approved protocol. At random, as chosen by one of the investigators, patients underwent imaging with one of three monomeric agents (iopamidol 300, iopromide 300, iohexol 300) and one dimeric agent (iodixanol 320). Measured GFR was determined immediately before CT and approximately 3 and 72 hours after the contrast injection for the CT examination. Iodinated contrast medium, a glomerular filtrate with no tubular excretion or reabsorption, was the GFR marker. Measured GFR was determined by x-ray fluorescence analysis with nonisotopic iodinated contrast media. RESULTS. Monomeric and dimeric contrast agents in diagnostic CT volumes (based on bodyweight and imaging protocol) did not induce a significant change in measured GFR (95% confidence by Wilcoxon test), suggesting that use of the evaluated contrast media will not lead to more than a 12% variation. CONCLUSION. The three monomeric agents studied and the one dimeric agent were equivalent in terms of lack of a significant effect on measured GFR when administered to patients with a normal GFR.
PMID: 23521455
ISSN: 0361-803x
CID: 255332

Impacting Key Performance Indicators in an Academic MR Imaging Department Through Process Improvement

Recht, Michael; Macari, Michael; Lawson, Kirk; Mulholland, Tom; Chen, David; Kim, Danny; Babb, James
PURPOSE: The aim of this study was to evaluate all aspects of workflow in a large academic MRI department to determine whether process improvement (PI) efforts could improve key performance indicators (KPIs). METHODS: KPI metrics in the investigators' MR imaging department include daily inpatient backlogs, on-time performance for outpatient examinations, examination volumes, appointment backlogs for pediatric anesthesia cases, and scan duration relative to time allotted for an examination. Over a 3-week period in April 2011, key members of the MR imaging department (including technologists, nurses, schedulers, physicians, and administrators) tracked all aspects of patient flow through the department, from scheduling to examination interpretation. Data were analyzed by the group to determine where PI could improve KPIs. Changes to MRI workflow were subsequently implemented, and KPIs were compared before (January 1, 2011, to April 30, 2011) and after (August 1, 2011, to December 31, 2011) using Mann-Whitney and Fisher's exact tests. RESULTS: The data analysis done during this PI led to multiple changes in the daily workflow of the MR department. In addition, a new sense of teamwork and empowerment was established within the MR staff. All of the measured KPIs showed statistically significant changes after the reengineering project. CONCLUSIONS: Intradepartmental PI efforts can significantly affect KPI metrics within an MR imaging department, making the process more patient centered. In addition, the process allowed significant growth without the need for additional equipment or personnel.
PMID: 23245434
ISSN: 1546-1440
CID: 214422

Diffusion-weighted Imaging of the Liver with Multiple b Values: Effect of Diffusion Gradient Polarity and Breathing Acquisition on Image Quality and Intravoxel Incoherent Motion Parameters--A Pilot Study

Dyvorne, Hadrien A; Galea, Nicola; Nevers, Thomas; Fiel, M Isabel; Carpenter, David; Wong, Edmund; Orton, Matthew; de Oliveira, Andre; Feiweier, Thorsten; Vachon, Marie-Louise; Babb, James S; Taouli, Bachir
Purpose: To optimize intravoxel incoherent motion (IVIM) diffusion-weighted (DW) imaging by estimating the effects of diffusion gradient polarity and breathing acquisition scheme on image quality, signal-to-noise ratio (SNR), IVIM parameters, and parameter reproducibility, as well as to investigate the potential of IVIM in the detection of hepatic fibrosis. Materials and Methods: In this institutional review board-approved prospective study, 20 subjects (seven healthy volunteers, 13 patients with hepatitis C virus infection; 14 men, six women; mean age, 46 years) underwent IVIM DW imaging with four sequences: (a) respiratory-triggered (RT) bipolar (BP) sequence, (b) RT monopolar (MP) sequence, (c) free-breathing (FB) BP sequence, and (d) FB MP sequence. Image quality scores were assessed for all sequences. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF) in liver parenchyma. Mixed-model analysis of variance was used to compare image quality, SNR, IVIM parameters, and interexamination variability between the four sequences, as well as the ability to differentiate areas of liver fibrosis from normal liver tissue. Results: Image quality with RT sequences was superior to that with FB acquisitions (P = .02) and was not affected by gradient polarity. SNR did not vary significantly between sequences. IVIM parameter reproducibility was moderate to excellent for PF and D, while it was less reproducible for D*. PF and D were both significantly lower in patients with hepatitis C virus than in healthy volunteers with the RT BP sequence (PF = 13.5% +/- 5.3 [standard deviation] vs 9.2% +/- 2.5, P = .038; D = [1.16 +/- 0.07] x 10(-3) mm(2)/sec vs [1.03 +/- 0.1] x 10(-3) mm(2)/sec, P = .006). Conclusion: The RT BP DW imaging sequence had the best results in terms of image quality, reproducibility, and ability to discriminate between healthy and fibrotic liver with biexponential fitting. (c) RSNA, 2012.
PMCID:3579172
PMID: 23220895
ISSN: 0033-8419
CID: 231632

Prospective-triggered sequential dual-source end-systolic coronary CT angiography for patients with atrial fibrillation: A feasibility study

Srichai, Monvadi B; Barreto, Mitya; Lim, Ruth P; Donnino, Robert; Babb, James S; Jacobs, Jill E
BACKGROUND: Obtaining diagnostic coronary CT angiography with low radiation exposure in patients with irregular heart rhythms such as atrial fibrillation (AF) remains challenging. OBJECTIVE: We evaluated image quality and inter-reader variability with the use of prospective electrocardiographic (ECG)-triggered sequential dual-source acquisition at end systole for coronary artery disease (CAD) evaluation in patients with AF. METHODS: Thirty consecutive patients with AF who underwent prospective ECG-triggered sequential dual-source acquisition were evaluated. Images were reconstructed every 50 milliseconds from 250 to 400 milliseconds after the R wave. Two independent, blinded readers evaluated the coronaries for image quality on a 5-point scale (worst to best) and stenosis on 5-point semiquantitative (none to severe) and binary scales (>50% or <50%). Diagnostic image quality was graded for each reconstruction. RESULTS: Eleven patients (37%) had significant (>/=50% stenosis) CAD. Average heart rate was 82 +/- 20 beats/min and variability range was 71 +/- 22 beats/min. Mean effective radiation dose was 6.5 +/- 2.4 mSv. Diagnostic image quality was noted in 97.9% of 304 coronary segments with median image quality of 3.0. The 300-millisecond reconstruction phase provided the highest image quality; 70% of patients showed diagnostic image quality. Combination of all phases (250-400 milliseconds) performed significantly better than single or other phase combinations (P < 0.0005 for all comparisons). Inter-reader variability for stenosis detection was excellent, with 98.4% concordance by using a binary scale (50% stenosis cutoff). CONCLUSIONS: Prospective ECG-triggered sequential dual-source CT acquisition with the use of end-systolic acquisition provides diagnostic image quality with potentially low radiation doses for evaluation of CAD in patients with AF. Use of multiple end-systolic phases over a 150-millisecond window improves diagnostic image quality.
PMID: 23545461
ISSN: 1876-861x
CID: 349232

Comparison of Atypical Femoral Fracture Patients on Long term Bisphosphonates with Controls matched for age and duration of bisphosphonate therapy [Meeting Abstract]

Mehta, Deeksha; Shamsuddin, Nazia; Rosenberg, Zehava S; Vieira, Renata L; Tejwani, Nirmal C; Egol, Kenneth A; Babb, James S; Peck, Valerie
ISI:000332035800229
ISSN: 1523-4681
CID: 2476382

Prognostic implications of the magnetic resonance imaging appearance in papillary renal cell carcinoma

Rosenkrantz, Andrew B; Sekhar, Aarti; Genega, Elizabeth M; Melamed, Jonathan; Babb, James S; Patel, Amish D; Lo, Andy; Najarian, Robert M; Ahmed, Muneeb; Pedrosa, Ivan
OBJECTIVE: To evaluate the prognostic implications of the MRI appearance and pathological features of papillary renal cell carcinoma (pRCC). METHODS: A total of 128 pRCC in 115 patients who underwent preoperative MRI were characterised in terms of pathological type (type 1 vs. type 2), MRI appearance (focal vs. infiltrative) and additional MRI features. Patients were classified on the basis of the presence or absence of metastatic disease. RESULTS: There were 65 focal type 1, 54 focal type 2 and 9 infiltrative pRCC. All infiltrative pRCC were of histopathological type 2. Renal vein thrombus was present in 89 % of infiltrative pRCC and no cases of focal pRCC. Metastatic disease was observed in 3.7 % of focal type 1, 7.5 % of focal type 2 and 75.0 % of infiltrative type 2 pRCC. Infiltrative MRI appearance was a significant predictor of metastatic disease, independent of pathological type, size and T stage (P 0.5). CONCLUSION: Infiltrative MRI appearance and renal vein thrombus identify a subset of pathological type 2 pRCC at a significantly increased risk of metastatic disease.
PMID: 22903703
ISSN: 0938-7994
CID: 220682

Serial proton MR spectroscopy of gray and white matter in relapsing-remitting MS

Kirov, Ivan I; Tal, Assaf; Babb, James S; Herbert, Joseph; Gonen, Oded
OBJECTIVE: To characterize and follow the diffuse gray and white matter (GM/WM) metabolic abnormalities in early relapsing-remitting multiple sclerosis using proton magnetic resonance spectroscopic imaging ((1)H-MRSI). METHODS: Eighteen recently diagnosed, mildly disabled patients (mean baseline time from diagnosis 32 months, mean Expanded Disability Status Scale [EDSS] score 1.3), all on immunomodulatory medication, were scanned semiannually for 3 years with T1-weighted and T2-weighted MRI and 3D (1)H-MRSI at 3 T. Ten sex- and age-matched controls were followed annually. Global absolute concentrations of N-acetylaspartate (NAA), choline (Cho), creatine (Cr), and myo-inositol (mI) were obtained for all GM and WM in the 360 cm(3) (1)H-MRSI volume of interest. RESULTS: Patients' average WM Cr, Cho, and mI concentrations (over all time points), 5.3 +/- 0.4, 1.6 +/- 0.1, and 5.1 +/- 0.7 mM, were 8%, 12%, and 11% higher than controls' (p
PMCID:3589203
PMID: 23175732
ISSN: 0028-3878
CID: 207352

Characterization of malignancy of adnexal lesions using ADC entropy: Comparison with mean ADC and qualitative DWI assessment

Kierans, Andrea S; Bennett, Genevieve L; Mussi, Thais C; Babb, James S; Rusinek, Henry; Melamed, Jonathan; Rosenkrantz, Andrew B
PURPOSE: To establish the utility of apparent diffusion coefficient (ADC) entropy in discrimination of benign and malignant adnexal lesions, using histopathology as the reference standard, via comparison of the diagnostic performance of ADC entropy with mean ADC and with visual assessments of adnexal lesions on conventional and diffusion-weighted sequences. MATERIALS AND METHODS: In all, 37 adult female patients with an ovarian mass that was resected between June 2006 and January 2011 were included. Volume-of-interest was drawn to incorporate all lesion voxels on every slice that included the mass on the ADC map, from which whole-lesion mean ADC and ADC entropy were calculated. Two independent radiologists also rated each lesion as benign or malignant based on visual assessment of all sequences. The Mann-Whitney test and logistic regression for correlated data were used to compare performance of mean ADC, ADC entropy, and the visual assessments. RESULTS: No statistically significant difference was observed in mean ADC between benign and malignant adnexal lesions (P = 0.768). ADC entropy was significantly higher in malignant than in benign lesions (P = 0.009). Accuracy was significantly greater for ADC entropy than for mean ADC (0.018). ADC entropy and visual assessment by the less-experienced reader showed similar accuracy (P >/= 0.204). The more experienced reader's accuracy was significantly greater than that of all other assessments (P
PMID: 23188749
ISSN: 1053-1807
CID: 203912

Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling

Chandarana, Hersh; Feng, Li; Block, Tobias K; Rosenkrantz, Andrew B; Lim, Ruth P; Babb, James S; Sodickson, Daniel K; Otazo, Ricardo
OBJECTIVE: The objectives of this study were to develop a new method for free-breathing contrast-enhanced multiphase liver magnetic resonance imaging (MRI) using a combination of compressed sensing, parallel imaging, and radial k-space sampling and to demonstrate the feasibility of this method by performing image quality comparison with breath-hold cartesian T1-weighted (conventional) postcontrast acquisitions in healthy participants. MATERIALS AND METHODS: This Health Insurance Portability and Accountability Act-compliant prospective study received approval from the institutional review board. Eight participants underwent 3 separate contrast-enhanced fat-saturated T1-weighted gradient-echo MRI examinations with matching imaging parameters: conventional breath-hold examination with cartesian k-space sampling volumetric interpolate breath hold examination (BH-VIBE) and free-breathing acquisitions with interleaved angle-bisection and continuous golden-angle radial sampling schemes. Interleaved angle-bisection and golden-angle data from each 100 consecutive spokes were reconstructed using a combination of compressed sensing and parallel imaging (interleaved-angle radial sparse parallel [IARASP] and golden-angle radial sparse parallel [GRASP]) to generate multiple postcontrast phases.Arterial- and venous-phase BH-VIBE, IARASP, and GRASP reconstructions were evaluated by 2 radiologists in a blinded fashion. The readers independently assessed quality of enhancement (QE), overall image quality (IQ), and other parameters of image quality on a 5-point scale, with the highest score indicating the most desirable examination. Mixed model analysis of variance was used to compare each measure of image quality. RESULTS: Images of BH-VIBE and GRASP had significantly higher QE and IQ values compared with IARASP for both phases (P < 0.05). The differences in QE between BH-VIBE and GRASP for the arterial and venous phases were not significant (P > 0.05). Although GRASP had lower IQ score compared with BH-VIBE for the arterial (3.9 vs 4.8; P < 0.0001) and venous (4.2 vs 4.8; P = 0.005) phases, GRASP received IQ scores of 3 or more in all participants, which was consistent with acceptable or better diagnostic image quality. CONCLUSION: Contrast-enhanced multiphase liver MRI of diagnostic quality can be performed during free breathing using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling.
PMCID:3833720
PMID: 23192165
ISSN: 0020-9996
CID: 202342