Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users

Padilla, Monica; Landsberger, David M
Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy.
PMCID:4907334
PMID: 26778546
ISSN: 1878-5891
CID: 1922002

Frequency-place map for electrical stimulation in cochlear implants: Change over time

Vermeire, Katrien; Landsberger, David M; Van de Heyning, Paul H; Voormolen, Maurits; Kleine Punte, Andrea; Schatzer, Reinhold; Zierhofer, Clemens
The relationship between the place of electrical stimulation from a cochlear implant and the corresponding perceived pitch remains uncertain. Previous studies have estimated what the pitch corresponding to a particular location should be. However, perceptual verification is difficult because a subject needs both a cochlear implant and sufficient residual hearing to reliably compare electric and acoustic pitches. Additional complications can arise from the possibility that the pitch corresponding to an electrode may change as the auditory system adapts to a sound processor. In the following experiment, five subjects with normal or near-to-normal hearing in one ear and a cochlear implant with a long electrode array in the other ear were studied. Pitch matches were made between single electrode pulse trains and acoustic tones before activation of the speech processor to gain an estimate of the pitch provided by electrical stimulation at a given insertion angle without the influence of exposure to a sound processor. The pitch matches were repeated after 1, 3, 6, and 12 months of experience with the sound processor to evaluate the effect of adaptation over time. Pre-activation pitch matches were lower than would be estimated by a spiral ganglion pitch map. Deviations were largest for stimulation below 240 degrees degrees and smallest above 480 degrees . With experience, pitch matches shifted towards the frequency-to-electrode allocation. However, no statistically significant pitch shifts were observed over time. The likely explanation for the lack of pitch change is that the frequency-to-electrode allocations for the long electrode arrays were already similar to the pre-activation pitch matches. Minimal place pitch shifts over time suggest a minimal amount of perceptual remapping needed for the integration of electric and acoustic stimuli, which may contribute to shorter times to asymptotic performance.
PMCID:4524783
PMID: 25840373
ISSN: 1878-5891
CID: 1663442

The Relationship Between Insertion Angles, Default Frequency Allocations, and Spiral Ganglion Place Pitch in Cochlear Implants

Landsberger, David M; Svrakic, Maja; Roland, J Thomas Jr; Svirsky, Mario
OBJECTIVES: Commercially available cochlear implant systems attempt to deliver frequency information going down to a few hundred Hertz, but the electrode arrays are not designed to reach the most apical regions of the cochlea, which correspond to these low frequencies. This may cause a mismatch between the frequencies presented by a cochlear implant electrode array and the frequencies represented at the corresponding location in a normal-hearing cochlea. In the following study, the mismatch between the frequency presented at a given cochlear angle and the frequency expected by an acoustic hearing ear at the corresponding angle is examined for the cochlear implant systems that are most commonly used in the United States. DESIGN: The angular insertion of each of the electrodes on four different electrode arrays (MED-EL Standard, MED-EL Flex28, Advanced Bionics HiFocus 1J, and Cochlear Contour Advance) was estimated from X-ray. For the angular location of each electrode on each electrode array, the predicted spiral ganglion frequency was estimated. The predicted spiral ganglion frequency was compared with the center frequency provided by the corresponding electrode using the manufacturer's default frequency-to-electrode allocation. RESULTS: Differences across devices were observed for the place of stimulation for frequencies below 650 Hz. Longer electrode arrays (i.e., the MED-EL Standard and Flex28) demonstrated smaller deviations from the spiral ganglion map than the other electrode arrays. For insertion angles up to approximately 270 degrees , the frequencies presented at a given location were typically approximately an octave below what would be expected by a spiral ganglion frequency map, while the deviations were larger for angles deeper than 270 degrees . For frequencies above 650 Hz, the frequency to angle relationship was consistent across all four electrode models. CONCLUSIONS: A mismatch was observed between the predicted frequency and the default frequency provided by every electrode on all electrode arrays. The mismatch can be reduced by changing the default frequency allocations, inserting electrodes deeper into the cochlea, or allowing cochlear implant users to adapt to the mismatch. Further studies are required to fully assess the clinical significance of the frequency mismatch.
PMCID:4549170
PMID: 25860624
ISSN: 1538-4667
CID: 1742442

Contributions of electric and acoustic hearing to bimodal speech and music perception

Crew, Joseph D; Galvin Iii, John J; Landsberger, David M; Fu, Qian-Jie
Cochlear implant (CI) users have difficulty understanding speech in noisy listening conditions and perceiving music. Aided residual acoustic hearing in the contralateral ear can mitigate these limitations. The present study examined contributions of electric and acoustic hearing to speech understanding in noise and melodic pitch perception. Data was collected with the CI only, the hearing aid (HA) only, and both devices together (CI+HA). Speech reception thresholds (SRTs) were adaptively measured for simple sentences in speech babble. Melodic contour identification (MCI) was measured with and without a masker instrument; the fundamental frequency of the masker was varied to be overlapping or non-overlapping with the target contour. Results showed that the CI contributes primarily to bimodal speech perception and that the HA contributes primarily to bimodal melodic pitch perception. In general, CI+HA performance was slightly improved relative to the better ear alone (CI-only) for SRTs but not for MCI, with some subjects experiencing a decrease in bimodal MCI performance relative to the better ear alone (HA-only). Individual performance was highly variable, and the contribution of either device to bimodal perception was both subject- and task-dependent. The results suggest that individualized mapping of CIs and HAs may further improve bimodal speech and music perception.
PMCID:4366155
PMID: 25790349
ISSN: 1932-6203
CID: 1539332

Loudness summation using focused and unfocused electrical stimulation

Padilla, Monica; Landsberger, David M
With a cochlear implant, when stimulation from multiple channels is interleaved, the perceived loudness is greater than the loudness associated with any of the individual channels presented in isolation. This phenomenon is known as loudness summation. This study examined if loudness summation with monopolar and tripolar stimulation were equivalent at two loudnesses and two spacing configurations. Results suggest that loudness summation is similar for monopolar and tripolar modes. However, larger summation differences were observed for softer sounds and louder sounds with a larger spatial separation. The results are consistent with the idea that loudness summation is dependent on channel interaction and have implications for implementing current-focused processing strategies.
PMCID:4042455
PMID: 25234912
ISSN: 1520-8524
CID: 2912392

Perceptual changes in place of stimulation with long cochlear implant electrode arrays

Landsberger, David M; Mertens, Griet; Punte, Andrea Kleine; Van De Heyning, Paul
Long (31.5 mm) electrode arrays are inserted deeper into the cochlea than the typical 1.25 turn insertion. With these electrode arrays, the apical electrodes are closer to (and possibly extend past) the end of the spiral ganglion. Using multi-dimensional scaling with patients implanted with a 31.5 mm electrode array, the perceptual space between electrodes was measured. The results suggest that deeper insertion increases the range of place pitches, but the perceptual differences between adjacent electrodes become smaller in the apex.
PMCID:3985910
PMID: 25234918
ISSN: 1520-8524
CID: 2912382

Multidimensional scaling between acoustic and electric stimuli in cochlear implant users with contralateral hearing

Vermeire, Katrien; Landsberger, David M; Schleich, Peter; Van de Heyning, Paul H
This study investigated the perceptual relationship between acoustic and electric stimuli presented to CI users with functional contralateral hearing. Fourteen subjects with unilateral profound deafness implanted with a MED-EL CI scaled the perceptual differences between pure tones presented to the acoustic hearing ear and electric biphasic pulse trains presented to the implanted ear. The differences were analyzed with a multidimensional scaling (MDS) analysis. Additionally, speech performance in noise was tested using sentence material presented in different spatial configurations while patients listened with both their acoustic hearing and implanted ears. Results of alternating least squares scaling (ALSCAL) analysis consistently demonstrate that a change in place of stimulation is in the same perceptual dimension as a change in acoustic frequency. However, the relative perceptual differences between the acoustic and the electric stimuli varied greatly across subjects. A degree of perceptual separation between acoustic and electric stimulation (quantified by relative dimensional weightings from an INDSCAL analysis) was hypothesized that would indicate a change in perceptual quality, but also be predictive of performance with combined acoustic and electric hearing. Perceptual separation between acoustic and electric stimuli was observed for some subjects. However, no relationship between the degree of perceptual separation and performance was found.
PMCID:3976044
PMID: 24055624
ISSN: 0378-5955
CID: 591982

The development of a modified spectral ripple test

Aronoff, Justin M; Landsberger, David M
Poor spectral resolution can be a limiting factor for hearing impaired listeners, particularly for complex listening tasks such as speech understanding in noise. Spectral ripple tests are commonly used to measure spectral resolution, but these tests contain a number of potential confounds that can make interpretation of the results difficult. To measure spectral resolution while avoiding those confounds, a modified spectral ripple test with dynamically changing ripples was created, referred to as the spectral-temporally modulated ripple test (SMRT). This paper describes the SMRT and provides evidence that it is sensitive to changes in spectral resolution.
PMCID:3732300
PMID: 23927228
ISSN: 0001-4966
CID: 591992

Improving speech perception in noise with current focusing in cochlear implant users

Srinivasan, Arthi G; Padilla, Monica; Shannon, Robert V; Landsberger, David M
Cochlear implant (CI) users typically have excellent speech recognition in quiet but struggle with understanding speech in noise. It is thought that broad current spread from stimulating electrodes causes adjacent electrodes to activate overlapping populations of neurons which results in interactions across adjacent channels. Current focusing has been studied as a way to reduce spread of excitation, and therefore, reduce channel interactions. In particular, partial tripolar stimulation has been shown to reduce spread of excitation relative to monopolar stimulation. However, the crucial question is whether this benefit translates to improvements in speech perception. In this study, we compared speech perception in noise with experimental monopolar and partial tripolar speech processing strategies. The two strategies were matched in terms of number of active electrodes, microphone, filterbanks, stimulation rate and loudness (although both strategies used a lower stimulation rate than typical clinical strategies). The results of this study showed a significant improvement in speech perception in noise with partial tripolar stimulation. All subjects benefited from the current focused speech processing strategy. There was a mean improvement in speech recognition threshold of 2.7 dB in a digits in noise task and a mean improvement of 3 dB in a sentences in noise task with partial tripolar stimulation relative to monopolar stimulation. Although the experimental monopolar strategy was worse than the clinical, presumably due to different microphones, frequency allocations and stimulation rates, the experimental partial-tripolar strategy, which had the same changes, showed no acute deficit relative to the clinical.
PMCID:3639477
PMID: 23467170
ISSN: 0378-5955
CID: 592002

Masking patterns for monopolar and phantom electrode stimulation in cochlear implants

Saoji, Aniket A; Landsberger, David M; Padilla, Monica; Litvak, Leonid M
Phantom electrode (PE) stimulation consists of out-of-phase stimulation of two electrodes. When presented at the apex of the electrode array, phantom stimulation is known to produce a lower pitch sensation than monopolar (MP) stimulation on the most apical electrode. The ratio of the current between the primary electrode (PEL) and the compensating electrode (CEL) is represented by the coefficient sigma, which ranges from 0 (monopolar) to 1 (full bipolar). The exact mechanism by which PE stimulation produces a lower pitch sensation is unclear. In the present study, unmasked and masked thresholds were obtained using a forward masking paradigm to estimate the spread of current for MP and PE stimulation. Masked thresholds were measured for two phantom electrode configurations (1) PEL = 4, CEL = 5 (lower pitch phantom) and (2) PEL = 4, CEL = 3 (higher pitch phantom). The unmasked thresholds were subtracted from the masked thresholds to obtain masking patterns which were normalized to their peak. The masking patterns reveal (1) differences in the spread of excitation that are consistent with the direction of pitch shift produced by PE stimulation, and (2) narrower spread of electrical excitation for PE stimulation relative to MP stimulation.
PMCID:3755121
PMID: 23299125
ISSN: 0378-5955
CID: 592012