Measurements of Radiation-Induced Skin Changes in Breast-Cancer Radiation Therapy Using Ultrasonic Imaging

Liu T; Zhou J; Osterman KS; Zhang P; Woodhouse SA; Schiff PB; Kutcher GJ
Skin injury is a common side effect of breast-cancer radiation therapy. Although physicians often observe skin toxicity, quantifying its severity remains a challenge. We present a novel quantitative ultrasonic technique to evaluate skin changes associated with radiotherapy. An in vivo study with twelve breast-cancer patients was conducted. All patients received a standard course of post-surgery radiation therapy. Each patient received ultrasound scans to the irradiated breast and the untreated (contra-lateral) breast. Radio-frequency (RF) backscatter signals and B-mode images were acquired simultaneously. To quantify the severity of skin injury, two metrics were calculated from the RF signals: skin thickness and Pearson correlation coefficient of the subcutaneous layer. Comparing to the non-irradiated skin, the average thickness of the irradiated skin increased by 40% (p=0.005) and the average correlation coefficient of the irradiated hypodermis decreased by 35% (p=0.02). This study demonstrates the feasibility of using a non-invasive ultrasonic technique to detect and quantify radiation-induced skin changes
PMCID:3066517
PMID: 21461130
ISSN: 1557-170x
CID: 146026

Quantitative assessment of tissue toxicity in breast cancer radiation therapy using spectrophotometry and ultrasonic tissue characterization imaging [Meeting Abstract]

Liu, T; Woodhouse, S; Zhou, J; Lu, Z; Pile-Spellman, E; Islam, S; Schiff, P; Zhang, P; Osterman, K; Kutcher, G
ISI:000247479601363
ISSN: 0094-2405
CID: 100796

How does performance of ultrasound tissue typing affect design of prostate IMRT dose-painting protocols?

Zhang, Pengpeng; Osterman, K Sunshine; Liu, Tian; Li, Xiang; Kessel, Jack; Wu, Leester; Schiff, Peter; Kutcher, Gerald J
PURPOSE: To investigate how the performance characteristics of ultrasound tissue typing (UTT) affect the design of a population-based prostate dose-painting protocol. METHODS AND MATERIALS: The performance of UTT is evaluated using the receiver operating characteristic curve. As the imager's sensitivity increases, more tumors are detected, but the specificity worsens, causing more false-positive results. The UTT tumor map, obtained with a specific sensitivity and specificity setup, was used with the patient's CT image to guide intensity-modulated radiotherapy (IMRT) planning. The optimal escalation dose to the UTT positive region, as well as the safe dose to the negative background, was obtained by maximizing the uncomplicated control (i.e., a combination of tumor control probability and weighted normal tissue complication probability). For high- and low-risk tumors, IMRT plans guided by conventional ultrasound or UTT with a one-dimensional or two-dimensional spectrum analysis technique were compared with an IMRT plan in which the whole prostate was dose escalated. RESULTS: For all imaging modalities, the specificity of 0.9 was chosen to reduce complications resulting from high false-positive results. If the primary tumors were low risk, the IMRT plans guided by all imaging modalities achieved high tumor control probability and reduced the normal tissue complication probability significantly compared with the plan with whole gland dose escalation. However, if the primary tumors were high risk, the accuracy of the imaging modality was critical to maintain the tumor control probability and normal tissue complication probability at acceptable levels. CONCLUSION: The performance characteristics of an imager have important implications in dose painting and should be considered in the design of dose-painting protocols
PMCID:2901543
PMID: 17236962
ISSN: 0360-3016
CID: 133540

Incorporate the imager's performance characteristics into the design of prostate IMRT dose painting protocols [Meeting Abstract]

Zhang, P; Liu, T; Osterman, K; Li, X; Schiff, P; Kutcher, G
ISI:000229908600090
ISSN: 0094-2405
CID: 100798

How does the performance of ultrasound tissue typing affect the design of prostate IMRT dose painting protocols? [Meeting Abstract]

Zhang, P; Liu, T; Osterman, S; Li, X; Kessel, J; Leester, W; Schiff, P; Kutcher, GJ
ISI:000232083300238
ISSN: 0360-3016
CID: 101066

Non-invasive assessment of radiation injury with electrical impedance spectroscopy

Osterman, K Sunshine; Hoopes, P Jack; DeLorenzo, Christine; Gladstone, David J; Paulsen, Keith D
A detailed understanding of non-targeted normal tissue response is necessary for the optimization of radiation treatment plans in cancer therapy. In this study, we evaluate the ability of electrical impedance spectroscopy (EIS) to non-invasively determine and quantify the injury response in soft tissue after high dose rate (HDR) irradiation, which is characterized by large localized dose distributions possessing steep spatial gradients. The HDR after-loading technique was employed to irradiate small volumes of muscle tissue with single doses (26-52 Gy targeted 5 mm away from the source). Impedance measurements were performed on 29 rats at 1, 2 and 3 month post-irradiation, employing 31 frequencies in the 1 kHz to 1 MHz range. Over the first 3 months, conductivity increased by 48% and 26% following target doses of 52 Gy and 26 Gy 5 mm from the HDR source, respectively. Injury, assessed independently through a grid-based scoring method showed a quadratic dependence on distance from source. A significant injury (50% of cells atrophied, necrotic or degenerating) in 1.2% of the volume, accompanied by more diffuse injury (25% of cells atrophied, necrotic or degenerating) in 9% of the tissue produced a conductivity increase of 0.02 S m(-1) (8% over a baseline of 0.24 S m(-1)). This was not statistically significant at p = 0.01. Among treatment groups, injury differences in 22% of the volume led to statistically significant differences in conductivity of 0.07 S m(-1) (23% difference in conductivity). Despite limitations, the success of EIS in detecting responses in a fraction of the tissue probed, during these early post-irradiation time-points, is encouraging. Electrical impedance spectroscopy may provide a useful metric of atrophy and the development of fibrosis secondary to radiation that could be further developed into a low-cost imaging method for radiotherapy monitoring and assessment
PMID: 15070195
ISSN: 0031-9155
CID: 146027

Dartmouth's next generation EIS system: preliminary hardware considerations

Hartov, A; Kerner, T E; Markova, M T; Osterman, K S; Paulsen, K D
Our previous system covered the frequency range of 0 to 1 MHz. In this new design we propose to cover the range from 0 to 10 MHz. The higher frequencies have forced us to reconsider several design decisions in view of both the physics of the problem and the performance of available electronic components. In this presentation we examine in detail the constraints faced by the designer, starting from wiring consideration to measurement techniques. We will also present the solutions we selected to overcome the limitations we discovered. The problems include phase detection, amplitude measurements, system organization and layout and finally system calibration
PMID: 11236886
ISSN: 0967-3334
CID: 146029

An improved data acquisition method for electrical impedance tomography

Kerner, T E; Harto, A; Osterman, K S; DeLorenzo, C; Paulsen, K D
Isaacson, Cheney and Seager have demonstrated that simultaneously applying trigonometric patterns of current to a circular electrode array optimizes the sensitivity of EIT to inner structure. We have found that it is less desirable to measure voltage at an electrode that also applies a current due to variable contact impedance. In order to preserve the optimum sensitivity while minimizing the effect of electrode artefacts, we have devised an approach where we sequentially apply a current between each individual electrode and a separate, fixed ground while measuring voltages at all other electrodes for each consecutive current impulse. By adding weighted sums of both the applied currents and corresponding measured voltages from individual passes, we can synthesize trigonometric patterns of any spatial frequency. Since only one of the electrodes in any given acquired data set is used as a source, this approach significantly dilutes the effect of contact impedance on the resulting voltage measurements. We present simulated data showing the equivalency between the synthesized and actual trigonometric excitation patterns. In addition, we report experimental data, both in vitro and in vivo, that show improved results using this data acquisition technique
PMID: 11236887
ISSN: 0967-3334
CID: 146028

Quantitative hemoglobin tomography with diffuse near-infrared spectroscopy: pilot results in the breast

Pogue, B W; Poplack, S P; McBride, T O; Wells, W A; Osterman, K S; Osterberg, U L; Paulsen, K D
The authors describe what is, to the best of their knowledge, the first quantitative hemoglobin concentration images of the female breast that were formed with model-based reconstruction of near-infrared intensity-modulated tomographic data. The results in 11 patients, including two with breast tumors with pathologic correlation, are summarized. Hemoglobin concentration appears to correlate with tumor vascularity without the need for exogenous contrast material and thereby has intrinsic diagnostic value
PMID: 11152812
ISSN: 0033-8419
CID: 146030

Electrical impedance imaging at multiple frequencies in phantoms

Kerner, T E; Williams, D B; Osterman, K S; Reiss, F R; Hartov, A; Paulsen, K D
We have recently built and tested a 32 channel, multi-frequency (1 kHz to 1 MHz) voltage mode system to investigate electrical impedance spectroscopy (EIS) imaging. We completed a series of phantom experiments to define the baseline imaging performance of our system. Our phantom consisted of a plastic circular tank (20 cm diameter) filled with 0.9% aqueous NaCl solution. Conductors and nonconductors of decreasing width (W5: 3.4 cm, W4: 2.54 cm, W3: 0.95 cm, W2: 0.64 cm and WI: 0.32 cm) were positioned at various distances from the tank edge (1 cm, 2 cm, 4 cm and 8 cm). The results suggest that the detection of objects less than 1 cm in width is limited to the first 1 to 2 cm from the tank edge for absolute images, but this depth can extend to 8 cm in difference images. Larger 3.4 cm wide objects can be detected in absolute images at depths up to 8 cm from the tank edge. Generally, conductor images were clearer than their nonconductor counterparts. Not only did electrode artefacts lessen as the frequency increased, but the system's maximum resolution was attained at the highest operating frequencies. Although the system recovered the value of the electrical conductivity at the correct order of magnitude, it tended to smooth out large property discontinuities. The calculated electrical permittivity in these phantom studies was inconclusive due to the presence of electrode artefacts
PMID: 10720001
ISSN: 0967-3334
CID: 146032