Searched for: in-biosketch:yes
person:otazor01
SparseCT: Interrupted-beam acquisition and sparse reconstruction for radiation dose reduction [Meeting Abstract]
Koesters, Thomas; Knoll, Florian; Sodickson, Aaron; Sodickson, Daniel K.; Otazo, Ricardo
ISI:000405562100025
ISSN: 0277-786x
CID: 4533852
Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer
Knoll, Florian; Holler, Martin; Koesters, Thomas; Otazo, Ricardo; Bredies, Kristian; Sodickson, Daniel K
While current state of the art MR-PET scanners enable simultaneous MR and PET measurements, the acquired data sets are still usually reconstructed separately. We propose a new multi-modality reconstruction framework using second order Total Generalized Variation (TGV) as a dedicated multi-channel regularization functional that jointly reconstructs images from both modalities. In this way, information about the underlying anatomy is shared during the image reconstruction process while unique differences are preserved. Results from numerical simulations and in-vivo experiments using a range of accelerated MR acquisitions and different MR image contrasts demonstrate improved PET image quality, resolution, and quantitative accuracy.
PMCID:5218518
PMID: 28055827
ISSN: 1558-254x
CID: 2529462
Compressed sensing for body MRI
Feng, Li; Benkert, Thomas; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo; Chandarana, Hersh
The introduction of compressed sensing for increasing imaging speed in magnetic resonance imaging (MRI) has raised significant interest among researchers and clinicians, and has initiated a large body of research across multiple clinical applications over the last decade. Compressed sensing aims to reconstruct unaliased images from fewer measurements than are traditionally required in MRI by exploiting image compressibility or sparsity. Moreover, appropriate combinations of compressed sensing with previously introduced fast imaging approaches, such as parallel imaging, have demonstrated further improved performance. The advent of compressed sensing marks the prelude to a new era of rapid MRI, where the focus of data acquisition has changed from sampling based on the nominal number of voxels and/or frames to sampling based on the desired information content. This article presents a brief overview of the application of compressed sensing techniques in body MRI, where imaging speed is crucial due to the presence of respiratory motion along with stringent constraints on spatial and temporal resolution. The first section provides an overview of the basic compressed sensing methodology, including the notion of sparsity, incoherence, and nonlinear reconstruction. The second section reviews state-of-the-art compressed sensing techniques that have been demonstrated for various clinical body MRI applications. In the final section, the article discusses current challenges and future opportunities. LEVEL OF EVIDENCE: 5 J. Magn. Reson. Imaging 2016.
PMCID:5352490
PMID: 27981664
ISSN: 1522-2586
CID: 2363682
Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity
Heacock, Laura; Gao, Yiming; Heller, Samantha L; Melsaether, Amy N; Babb, James S; Block, Tobias K; Otazo, Ricardo; Kim, Sungheon G; Moy, Linda
PURPOSE: To compare a novel multicoil compressed sensing technique with flexible temporal resolution, golden-angle radial sparse parallel (GRASP), to conventional fat-suppressed spoiled three-dimensional (3D) gradient-echo (volumetric interpolated breath-hold examination, VIBE) MRI in evaluating the conspicuity of benign and malignant breast lesions. MATERIALS AND METHODS: Between March and August 2015, 121 women (24-84 years; mean, 49.7 years) with 180 biopsy-proven benign and malignant lesions were imaged consecutively at 3.0 Tesla in a dynamic contrast-enhanced (DCE) MRI exam using sagittal T1-weighted fat-suppressed 3D VIBE in this Health Insurance Portability and Accountability Act-compliant, retrospective study. Subjects underwent MRI-guided breast biopsy (mean, 13 days [1-95 days]) using GRASP DCE-MRI, a fat-suppressed radial "stack-of-stars" 3D FLASH sequence with golden-angle ordering. Three readers independently evaluated breast lesions on both sequences. Statistical analysis included mixed models with generalized estimating equations, kappa-weighted coefficients and Fisher's exact test. RESULTS: All lesions demonstrated good conspicuity on VIBE and GRASP sequences (4.28 +/- 0.81 versus 3.65 +/- 1.22), with no significant difference in lesion detection (P = 0.248). VIBE had slightly higher lesion conspicuity than GRASP for all lesions, with VIBE 12.6% (0.63/5.0) more conspicuous (P < 0.001). Masses and nonmass enhancement (NME) were more conspicuous on VIBE (P < 0.001), with a larger difference for NME (14.2% versus 9.4% more conspicuous). Malignant lesions were more conspicuous than benign lesions (P < 0.001) on both sequences. CONCLUSION: GRASP DCE-MRI, a multicoil compressed sensing technique with high spatial resolution and flexible temporal resolution, has near-comparable performance to conventional VIBE imaging for breast lesion evaluation. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2016.
PMCID:5538366
PMID: 27859874
ISSN: 1522-2586
CID: 2311022
Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration
Otazo, Ricardo; Nittka, Mathias; Bruno, Mary; Raithel, Esther; Geppert, Christian; Gyftopoulos, Soterios; Recht, Michael; Rybak, Leon
PURPOSE: To develop an accelerated SEMAC metal implant MRI technique (Sparse-SEMAC) with reduced scan time and improved metal distortion correction. METHODS: Sparse-SEMAC jointly exploits the inherent sparsity along the additional phase-encoding dimension and multicoil encoding capabilities to significantly accelerate data acquisition. A prototype pulse sequence with pseudorandom ky -kz undersampling and an inline image reconstruction was developed for integration in clinical studies. Three patients with hip implants were imaged using the proposed Sparse-SEMAC with eight-fold acceleration and compared with the standard-SEMAC technique used in clinical studies (three-fold GRAPPA acceleration). Measurements were performed with SEMAC-encoding steps (SES) = 15 for Sparse-SEMAC and SES = 9 for Standard-SEMAC using high spatial resolution Proton Density (PD) and lower-resolution STIR acquisitions. Two expert musculoskeletal (MSK) radiologists performed a consensus reading to score image-quality parameters. RESULTS: Sparse-SEMAC enables up to eight-fold acceleration of data acquisition that results in two-fold scan time reductions, compared with Standard-SEMAC, with improved metal artifact correction for patients with hip implants without degrading spatial resolution. CONCLUSION: The high acceleration enabled by Sparse-SEMAC would enable clinically feasible examination times with improved correction of metal distortion. Magn Reson Med, 2016. (c) 2016 Wiley Periodicals, Inc.
PMCID:5266741
PMID: 27454003
ISSN: 1522-2594
CID: 2191422
Four-dimensional respiratory motion-resolved whole heart coronary MR angiography
Piccini, Davide; Feng, Li; Bonanno, Gabriele; Coppo, Simone; Yerly, Jerome; Lim, Ruth P; Schwitter, Juerg; Sodickson, Daniel K; Otazo, Ricardo; Stuber, Matthias
PURPOSE: Free-breathing whole-heart coronary MR angiography (MRA) commonly uses navigators to gate respiratory motion, resulting in lengthy and unpredictable acquisition times. Conversely, self-navigation has 100% scan efficiency, but requires motion correction over a broad range of respiratory displacements, which may introduce image artifacts. We propose replacing navigators and self-navigation with a respiratory motion-resolved reconstruction approach. METHODS: Using a respiratory signal extracted directly from the imaging data, individual signal-readouts are binned according to their respiratory states. The resultant series of undersampled images are reconstructed using an extradimensional golden-angle radial sparse parallel imaging (XD-GRASP) algorithm, which exploits sparsity along the respiratory dimension. Whole-heart coronary MRA was performed in 11 volunteers and four patients with the proposed methodology. Image quality was compared with that obtained with one-dimensional respiratory self-navigation. RESULTS: Respiratory-resolved reconstruction effectively suppressed respiratory motion artifacts. The quality score for XD-GRASP reconstructions was greater than or equal to self-navigation in 80/88 coronary segments, reaching diagnostic quality in 61/88 segments versus 41/88. Coronary sharpness and length were always superior for the respiratory-resolved datasets, reaching statistical significance (P < 0.05) in most cases. CONCLUSION: XD-GRASP represents an attractive alternative for handling respiratory motion in free-breathing whole heart MRI and provides an effective alternative to self-navigation. Magn Reson Med, 2016. (c) 2016 Wiley Periodicals, Inc.
PMCID:5040623
PMID: 27052418
ISSN: 1522-2594
CID: 2066172
Low Rank plus Sparse Spatiotemporal MRI: Acceleration, Background Suppression, and Motion Learning
Chapter by: Otazo, Ricardo; Candes, Emmanuel; Sodickson, Daniel K
in: Handbook of robust low-rank and sparse matrix decomposition : applications in image and video processing by Bouwmans, Thierry; Aybat, Necdet Serhat; Zahzah, El-hadi [Eds]
Boca Raton, FL : CRC Press, 2016
pp. 17-1-17-18
ISBN: 1498724620
CID: 2492982
Analysis of cardiac interventricular Septum Motion in different respiratory States [Meeting Abstract]
Tautz, Lennart; Feng, Li; Otazo, Ricardo; Hennemuth, Anja; Axel, Leon
The interaction between the left and right heart ventricles (LV and RV) depends on load and pressure conditions that are affected by cardiac contraction and respiration cycles. A novel MRI sequence, XD-GRASP, allows the acquisition of multi-dimensional, respiration-sorted and cardiac-synchronized free-breathing image data. In these data, effects of the cardiac and respiratory cycles on the LV/RV interaction can be observed independently. To enable the analysis of such data, we developed a semi-automatic exploration workflow. After tracking a cross-sectional line positioned over the heart, over all motion states, the septum and heart wall border locations are detected by analyzing the grey-value profile under the lines. These data are used to quantify septum motion, both in absolute units and as a fraction of the heart size, to compare values for different subjects. In addition to conventional visualization techniques, we used color maps for intuitive exploration of the variable values for this multi-dimensional data set. We acquired short-axis image data of nine healthy volunteers, to analyze the position and the motion of the interventricular septum in different breathing states and different cardiac cycle phases. The results indicate a consistent range of normal septum motion values, and also suggest that respiratory phase-dependent septum motion is greatest near end-diastolic phases. These new methods are a promising tool to assess LV/RV ventricle interaction and the effects of respiration on this interaction.
ISI:000378223800029
ISSN: 0277-786x
CID: 2228162
3D TSE imaging using sparse-sense acceleration: Comparison with conventional 2D tse imaging for detection of internal derangement of the knee [Meeting Abstract]
Recht, M; Otazo, R; Rybak, L; Gyftopoulos, S; Petchprapa, C; Bruno, M; Geppert, C; Raithel, E
Purpose: To compare the accuracy of an optimized 3D TSE (SPACE) sequence using SPARSE-SENSE (SS) acceleration with 2D TSE sequences for the detection of internal derangement of the knee. Materials and Methods: An optimized accelerated SPACE sequence prototype was developed using avariable-density poisson-disc undersampling pattern of the two phase-encoding dimensions. Optimized parameters were: TR1100, TE22, TF28, variable flip angle evolution for PD weighting, SS undersampling factor of 9, fat suppression, presence of an optimized MT module, and 0.5 x 0.5 x 0.6 mm3 voxel size. This sequence (TA 4:57) was added to our conventional knee examination (sagittal PD and FS T2, coronal PD and FS PD, axial FS T2 2D TSE sequences (TA 10:56)) for 579 patients undergoing knee MR examinations imaged on a 3T scanner (Magnetom Skyra, Siemens Healthcare). An iterative SS reconstruction [2] was performed by enforcing sparsity in the wavelet representation of the knee images. Images were then reformatted in all 3 orthogonal planes at 1.5mmthickness. 50 of the 579 patients underwent arthroscopy of the knee and two experienced MSK radiologists blindly reviewed the SS SPACE sequence and the conventional 2D TSE sequences of these 50 patients at separate sittings to evaluate for the presence of meniscal or ligamentous tears. Results: 38 patients hadmedialmeniscal tears, 23 had lateral meniscal tears, and 16 had ACL tears. There was only 1 MCLand PCL tear and there were no LCL tears. The sensitivity, specificity, and accuracy for medial meniscal, lateral meniscal, and ACL tears on the 2D TSE images and SS Space images for each reader are presented below. Sensitivity Specificity Accuracy Sensitivity Specificity Accuracy Conclusion: An optimized and accelerated 3D TSE sequence has the potential to replace 2D TSE sequences for evaluation of internal derangement of the knee. If substantiated in larger clinical studies, this could lead to significant shortening of exam time, potentially enlarging the indication and utilization of knee MR as well as decreasing its cost
EMBASE:72341839
ISSN: 1432-2161
CID: 2204912
Accelerated MRI for the assessment of cardiac function
Axel, Leon; Otazo, Ricardo
Heart disease is a worldwide public health problem; assessment of cardiac function is an important part of the diagnosis and management of heart disease. Magnetic resonance imaging (MRI) of the heart can provide clinically useful information on cardiac function, although it is still not routinely used in clinical practice, in part because of limited imaging speed. New accelerated methods for performing cardiovascular MRI (CMR) have the potential to provide both increased imaging speed and robustness to CMR, as well as access to increased functional information. In this review, we will briefly discuss the main methods currently employed to accelerate CMR methods, such as parallel imaging, k-t undersampling and compressed sensing, as well as new approaches that extend the idea of compressed sensing and exploit sparsity to provide richer information of potential use in clinical practice.
PMCID:5257298
PMID: 27033471
ISSN: 1748-880x
CID: 2059282