Neuronal activity under transcranial radio-frequency stimulation in metal-free rodent brains in-vivo

Yaghmazadeh, Omid; Vöröslakos, Mihály; Alon, Leeor; Carluccio, Giuseppe; Collins, Christopher; Sodickson, Daniel K; Buzsáki, György
As the use of Radio Frequency (RF) technologies increases, the impact of RF radiation on neurological function continues to receive attention. Whether RF radiation can modulate ongoing neuronal activity by non-thermal mechanisms has been debated for decades. However, the interactions between radiated energy and metal-based neural probes during experimentation could impact neural activity, making interpretation of the results difficult. To address this problem, we modified a miniature 1-photon Ca2+ imaging device to record interference-free neural activity and compared the results to those acquired using metal-containing silicon probes. We monitored the neuronal activity of awake rodent-brains under RF energy exposure (at 950 MHz) and in sham control paradigms. Spiking activity was reliably affected by RF energy in metal containing systems. However, we did not observe neuronal responses using metal-free optical recordings at induced local electric field strengths up to 230 V/m. Our results suggest that RF exposure higher than levels that are allowed by regulatory limits in real-life scenarios do not affect neuronal activity.
PMCID:10732550
PMID: 38125336
ISSN: 2731-3395
CID: 5892492

Diagnostic abdominal MR imaging on a prototype low-field 0.55 T scanner operating at two different gradient strengths

Chandarana, Hersh; Bagga, Barun; Huang, Chenchan; Dane, Bari; Petrocelli, Robert; Bruno, Mary; Keerthivasan, Mahesh; Grodzki, David; Block, Kai Tobias; Stoffel, David; Sodickson, Daniel K
PURPOSE:To develop a protocol for abdominal imaging on a prototype 0.55 T scanner and to benchmark the image quality against conventional 1.5 T exam. METHODS:In this prospective IRB-approved HIPAA-compliant study, 10 healthy volunteers were recruited and imaged. A commercial MRI system was modified to operate at 0.55 T (LF) with two different gradient performance levels. Each subject underwent non-contrast abdominal examinations on the 0.55 T scanner utilizing higher gradients (LF-High), lower adjusted gradients (LF-Adjusted), and a conventional 1.5 T scanner. The following pulse sequences were optimized: fat-saturated T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and Dixon T1-weighted imaging (T1WI). Three readers independently evaluated image quality in a blinded fashion on a 5-point Likert scale, with a score of 1 being non-diagnostic and 5 being excellent. An exact paired sample Wilcoxon signed-rank test was used to compare the image quality. RESULTS:Diagnostic image quality (overall image quality score ≥ 3) was achieved at LF in all subjects for T2WI, DWI, and T1WI with no more than one unit lower score than 1.5 T. The mean difference in overall image quality score was not significantly different between LF-High and LF-Adjusted for T2WI (95% CI - 0.44 to 0.44; p = 0.98), DWI (95% CI - 0.43 to 0.36; p = 0.92), and for T1 in- and out-of-phase imaging (95%C I - 0.36 to 0.27; p = 0.91) or T1 fat-sat (water only) images (95% CI - 0.24 to 0.18; p = 1.0). CONCLUSION:Diagnostic abdominal MRI can be performed on a prototype 0.55 T scanner, either with conventional or with reduced gradient performance, within an acquisition time of 10 min or less.
PMID: 34415411
ISSN: 2366-0058
CID: 5048652

A workflow to generate patient-specific three-dimensional augmented reality models from medical imaging data and example applications in urologic oncology

Wake, Nicole; Rosenkrantz, Andrew B; Huang, William C; Wysock, James S; Taneja, Samir S; Sodickson, Daniel K; Chandarana, Hersh
Augmented reality (AR) and virtual reality (VR) are burgeoning technologies that have the potential to greatly enhance patient care. Visualizing patient-specific three-dimensional (3D) imaging data in these enhanced virtual environments may improve surgeons' understanding of anatomy and surgical pathology, thereby allowing for improved surgical planning, superior intra-operative guidance, and ultimately improved patient care. It is important that radiologists are familiar with these technologies, especially since the number of institutions utilizing VR and AR is increasing. This article gives an overview of AR and VR and describes the workflow required to create anatomical 3D models for use in AR using the Microsoft HoloLens device. Case examples in urologic oncology (prostate cancer and renal cancer) are provided which depict how AR has been used to guide surgery at our institution.
PMCID:8554989
PMID: 34709482
ISSN: 2365-6271
CID: 5042602

Free-breathing radial imaging using a pilot-tone radiofrequency transmitter for detection of respiratory motion

Solomon, Eddy; Rigie, David S; Vahle, Thomas; Paška, Jan; Bollenbeck, Jan; Sodickson, Daniel K; Boada, Fernando E; Block, Kai Tobias; Chandarana, Hersh
PURPOSE/OBJECTIVE:To describe an approach for detection of respiratory signals using a transmitted radiofrequency (RF) reference signal called Pilot-Tone (PT) and to use the PT signal for creation of motion-resolved images based on 3D stack-of-stars imaging under free-breathing conditions. METHODS:This work explores the use of a reference RF signal generated by a small RF transmitter, placed outside the MR bore. The reference signal is received in parallel to the MR signal during each readout. Because the received PT amplitude is modulated by the subject's breathing pattern, a respiratory signal can be obtained by detecting the strength of the received PT signal over time. The breathing-induced PT signal modulation can then be used for reconstructing motion-resolved images from free-breathing scans. The PT approach was tested in volunteers using a radial stack-of-stars 3D gradient echo (GRE) sequence with golden-angle acquisition. RESULTS:Respiratory signals derived from the proposed PT method were compared to signals from a respiratory cushion sensor and k-space-center-based self-navigation under different breathing conditions. Moreover, the accuracy was assessed using a modified acquisition scheme replacing the golden-angle scheme by a zero-angle acquisition. Incorporating the PT signal into eXtra-Dimensional (XD) motion-resolved reconstruction led to improved image quality and clearer anatomical depiction of the lung and liver compared to k-space-center signal and motion-averaged reconstruction, when binned into 6, 8, and 10 motion states. CONCLUSION/CONCLUSIONS:PT is a novel concept for tracking respiratory motion. Its small dimension (8 cm), high sampling rate, and minimal interaction with the imaging scan offers great potential for resolving respiratory motion.
PMID: 33306216
ISSN: 1522-2594
CID: 4709402

Magnetic-resonance-based electrical property mapping using Global Maxwell Tomography with an 8-channel head coil at 7 Tesla: a simulation study

Giannakopoulos, Ilias; Serralles, Jose Ec; Daniel, Luca; Sodickson, Daniel; Polimeridis, Athanasios; White, Jacob K; Lattanzi, Riccardo
OBJECTIVE:Global Maxwell Tomography (GMT) is a recently introduced volumetric technique for noninvasive estimation of electrical properties (EP) from magnetic resonance measurements. Previous work evaluated GMT using ideal radiofrequency (RF) excitations. The aim of this simulation study was to assess GMT performance with a realistic RF coil. METHODS:) inside heterogeneous head models for different RF shimming approaches, and used them as input for GMT to reconstruct EP for all voxels. RESULTS:) and absorbed power could be predicted with less than 0.5% error over the entire head. GMT could accurately detect a numerically inserted tumor. CONCLUSION/CONCLUSIONS:This work demonstrates that GMT can reliably reconstruct EP in realistic simulated scenarios using a tailored 8-channel RF coil design at 7T. Future work will focus on construction of the coil and optimization of GMT's robustness to noise, to enable in vivo GMT experiments. SIGNIFICANCE/CONCLUSIONS:GMT could provide accurate estimations of tissue EP, which could be used as biomarkers and could enable patient-specific estimation of RF power deposition, which is an unsolved problem for ultra-high-field magnetic resonance imaging.
PMID: 32365014
ISSN: 1558-2531
CID: 4429892

The brain after COVID-19: Compensatory neurogenesis or persistent neuroinflammation?

Goldberg, Elkhonon; Podell, Kenneth; Sodickson, Daniel K; Fieremans, Els
PMCID:7773850
PMID: 33409480
ISSN: 2589-5370
CID: 4771262

Training a neural network for Gibbs and noise removal in diffusion MRI

Muckley, Matthew J; Ades-Aron, Benjamin; Papaioannou, Antonios; Lemberskiy, Gregory; Solomon, Eddy; Lui, Yvonne W; Sodickson, Daniel K; Fieremans, Els; Novikov, Dmitry S; Knoll, Florian
PURPOSE/OBJECTIVE:To develop and evaluate a neural network-based method for Gibbs artifact and noise removal. METHODS:A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models were based on the same encoder-decoder structure and were trained by simulating MRI acquisitions on synthetic non-MRI images. RESULTS:Both machine learning methods were able to mitigate artifacts in diffusion-weighted images and diffusion parameter maps. The CNN for complex images was also able to reduce artifacts in partial Fourier acquisitions. CONCLUSIONS:The proposed CNNs extend the ability of artifact correction in diffusion MRI. The machine learning method described here can be applied on each imaging slice independently, allowing it to be used flexibly in clinical applications.
PMID: 32662910
ISSN: 1522-2594
CID: 4528102

Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challenge

Knoll, Florian; Murrell, Tullie; Sriram, Anuroop; Yakubova, Nafissa; Zbontar, Jure; Rabbat, Michael; Defazio, Aaron; Muckley, Matthew J; Sodickson, Daniel K; Zitnick, C Lawrence; Recht, Michael P
PURPOSE/OBJECTIVE:To advance research in the field of machine learning for MR image reconstruction with an open challenge. METHODS:We provided participants with a dataset of raw k-space data from 1,594 consecutive clinical exams of the knee. The goal of the challenge was to reconstruct images from these data. In order to strike a balance between realistic data and a shallow learning curve for those not already familiar with MR image reconstruction, we ran multiple tracks for multi-coil and single-coil data. We performed a two-stage evaluation based on quantitative image metrics followed by evaluation by a panel of radiologists. The challenge ran from June to December of 2019. RESULTS:We received a total of 33 challenge submissions. All participants chose to submit results from supervised machine learning approaches. CONCLUSIONS:The challenge led to new developments in machine learning for image reconstruction, provided insight into the current state of the art in the field, and highlighted remaining hurdles for clinical adoption.
PMID: 32506658
ISSN: 1522-2594
CID: 4505052

MRI guided procedure planning and 3D simulation for partial gland cryoablation of the prostate: a pilot study

Wake, Nicole; Rosenkrantz, Andrew B; Sodickson, Daniel K; Chandarana, Hersh; Wysock, James S
PURPOSE/OBJECTIVE:This study reports on the development of a novel 3D procedure planning technique to provide pre-ablation treatment planning for partial gland prostate cryoablation (cPGA). METHODS:Twenty men scheduled for partial gland cryoablation (cPGA) underwent pre-operative image segmentation and 3D modeling of the prostatic capsule, index lesion, urethra, rectum, and neurovascular bundles based upon multi-parametric MRI data. Pre-treatment 3D planning models were designed including virtual 3D cryotherapy probes to predict and plan cryotherapy probe configuration needed to achieve confluent treatment volume. Treatment efficacy was measured with 6 month post-operative MRI, serum prostate specific antigen (PSA) at 3 and 6 months, and treatment zone biopsy results at 6 months. Outcomes from 3D planning were compared to outcomes from a series of 20 patients undergoing cPGA using traditional 2D planning techniques. RESULTS:Forty men underwent cPGA. The median age of the cohort undergoing 3D treatment planning was 64.8 years with a median pretreatment PSA of 6.97 ng/mL. The Gleason grade group (GGG) of treated index lesions in this cohort included 1 (5%) GGG1, 11 (55%) GGG2, 7 (35%) GGG3, and 1 (5%) GGG4. Two (10%) of these treatments were post-radiation salvage therapies. The 2D treatment cohort included 20 men with a median age of 68.5 yrs., median pretreatment PSA of 6.76 ng/mL. The Gleason grade group (GGG) of treated index lesions in this cohort included 3 (15%) GGG1, 8 (40%) GGG2, 8 (40%) GGG3, 1 (5%) GGG4. Two (10%) of these treatments were post-radiation salvage therapies. 3D planning predicted the same number of cryoprobes for each group, however a greater number of cryoprobes was used in the procedure for the prospective 3D group as compared to that with 2D planning (4.10 ± 1.37 and 3.25 ± 0.44 respectively, p = 0.01). At 6 months post cPGA, the median PSA was 1.68 ng/mL and 2.38 ng/mL in the 3D and 2D cohorts respectively, with a larger decrease noted in the 3D cohort (75.9% reduction noted in 3D cohort and 64.8% reduction 2D cohort, p 0.48). In-field disease detection was 1/14 (7.1%) on surveillance biopsy in the 3D cohort and 3/14 (21.4%) in the 2D cohort, p = 0.056) In the 3D cohort, 6 month biopsy was not performed in 4 patients (20%) due to undetectable PSA, negative MRI, and negative MRI Axumin PET. For the group with traditional 2D planning, treatment zone biopsy was positive in 3/14 (21.4%) of the patients, p = 0.056. CONCLUSIONS:3D prostate cancer models derived from mpMRI data provide novel guidance for planning confluent treatment volumes for cPGA and predicted a greater number of treatment probes than traditional 2D planning methods. This study prompts further investigation into the use of 3D treatment planning techniques as the increase of partial gland ablation treatment protocols develop.
PMCID:7607830
PMID: 33141272
ISSN: 2365-6271
CID: 4655982

Using Deep Learning to Accelerate Knee MRI at 3T: Results of an Interchangeability Study

Recht, Michael P; Zbontar, Jure; Sodickson, Daniel K; Knoll, Florian; Yakubova, Nafissa; Sriram, Anuroop; Murrell, Tullie; Defazio, Aaron; Rabbat, Michael; Rybak, Leon; Kline, Mitchell; Ciavarra, Gina; Alaia, Erin F; Samim, Mohammad; Walter, William R; Lin, Dana; Lui, Yvonne W; Muckley, Matthew; Huang, Zhengnan; Johnson, Patricia; Stern, Ruben; Zitnick, C Lawrence
OBJECTIVE:Deep Learning (DL) image reconstruction has the potential to disrupt the current state of MR imaging by significantly decreasing the time required for MR exams. Our goal was to use DL to accelerate MR imaging in order to allow a 5-minute comprehensive examination of the knee, without compromising image quality or diagnostic accuracy. METHODS:A DL model for image reconstruction using a variational network was optimized. The model was trained using dedicated multi-sequence training, in which a single reconstruction model was trained with data from multiple sequences with different contrast and orientations. Following training, data from 108 patients were retrospectively undersampled in a manner that would correspond with a net 3.49-fold acceleration of fully-sampled data acquisition and 1.88-fold acceleration compared to our standard two-fold accelerated parallel acquisition. An interchangeability study was performed, in which the ability of 6 readers to detect internal derangement of the knee was compared for the clinical and DL-accelerated images. RESULTS:The study demonstrated a high degree of interchangeability between standard and DL-accelerated images. In particular, results showed that interchanging the sequences would result in discordant clinical opinions no more than 4% of the time for any feature evaluated. Moreover, the accelerated sequence was judged by all six readers to have better quality than the clinical sequence. CONCLUSIONS:An optimized DL model allowed for acceleration of knee images which performed interchangeably with standard images for the detection of internal derangement of the knee. Importantly, readers preferred the quality of accelerated images to that of standard clinical images.
PMID: 32755163
ISSN: 1546-3141
CID: 4557132