A low-cost Mr compatible ergometer to assess post-exercise phosphocreatine recovery kinetics
Naimon, Niels D; Walczyk, Jerzy; Babb, James S; Khegai, Oleksandr; Che, Xuejiao; Alon, Leeor; Regatte, Ravinder R; Brown, Ryan; Parasoglou, Prodromos
OBJECTIVE: To develop a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems to reliably quantify metabolic parameters in human lower leg muscle using phosphorus magnetic resonance spectroscopy. MATERIALS AND METHODS: We constructed an MR compatible ergometer using commercially available materials and elastic bands that provide resistance to movement. We recruited ten healthy subjects (eight men and two women, mean age +/- standard deviation: 32.8 +/- 6.0 years, BMI: 24.1 +/- 3.9 kg/m2). All subjects were scanned on a 7 T whole-body magnet. Each subject was scanned on two visits and performed a 90 s plantar flexion exercise at 40% maximum voluntary contraction during each scan. During the first visit, each subject performed the exercise twice in order for us to estimate the intra-exam repeatability, and once during the second visit in order to estimate the inter-exam repeatability of the time constant of phosphocreatine recovery kinetics. We assessed the intra and inter-exam reliability in terms of the within-subject coefficient of variation (CV). RESULTS: We acquired reliable measurements of PCr recovery kinetics with an intra- and inter-exam CV of 7.9% and 5.7%, respectively. CONCLUSION: We constructed a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems, which allowed us to quantify reliably PCr recovery kinetics in lower leg muscle using 31P-MRS.
PMCID:5441940
PMID: 28054143
ISSN: 1352-8661
CID: 2386752
Prospects for Millimeter-Wave Compliance Measurement Technologies
Alon, Leeor; Gabriel, Sami; Cho, Gene Young; Brown, Ryan; Deniz, Cem M
PMCID:6083874
PMID: 30100682
ISSN: 1045-9243
CID: 3254502
29-Channel receive-only dense dipole head array for 7T MRI
Chapter by: Zhang, Bei; Chen, Gang; Cloos, Martijn; Yu, Zidan; Walczyk, Jerzy; Collins, Christopher; Brown, Ryan; Lattanzi, Riccardo; Sodickson, Daniel; Wiggins, Graham
in: 2017 International Conference on Electromagnetics in Advanced Applications (ICEAA) by
pp. 1624-1627
ISBN: 978-1-5090-4451-1
CID: 2789932
A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T
Brown, Ryan; Lakshmanan, Karthik; Madelin, Guillaume; Alon, Leeor; Chang, Gregory; Sodickson, Daniel K; Regatte, Ravinder R; Wiggins, Graham C
PURPOSE: We describe a 2 x 6 channel sodium/proton array for knee MRI at 3T. Multielement coil arrays are desirable because of well-known signal-to-noise ratio advantages over volume and single-element coils. However, low tissue-coil coupling that is characteristic of coils operating at low frequency can make the potential gains from a phased array difficult to realize. METHODS: The issue of low tissue-coil coupling in the developed six-channel sodium receive array was addressed by implementing 1) a mechanically flexible former to minimize the coil-to-tissue distance and reduce the overall diameter of the array and 2) a wideband matching scheme that counteracts preamplifier noise degradation caused by coil coupling and a high-quality factor. The sodium array was complemented with a nested proton array to enable standard MRI. RESULTS: The wideband matching scheme and tight-fitting mechanical design contributed to >30% central signal-to-noise ratio gain on the sodium module over a mononuclear sodium birdcage coil, and the performance of the proton module was sufficient for clinical imaging. CONCLUSION: We expect the strategies presented in this study to be generally relevant in high-density receive arrays, particularly in x-nuclei or small animal applications. Magn Reson Med, 2015. (c) 2015 Wiley Periodicals, Inc.
PMCID:4846593
PMID: 26502310
ISSN: 1522-2594
CID: 1817442
Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles using a Dual-Frequency Coil Array
Brown, Ryan; Khegai, Oleksandr; Parasoglou, Prodromos
Magnetic resonance imaging (MRI) provides the unique ability to study metabolic and microvasculature functions in skeletal muscle using phosphorus and proton measurements. However, the low sensitivity of these techniques can make it difficult to capture dynamic muscle activity due to the temporal resolution required for kinetic measurements during and after exercise tasks. Here, we report the design of a dual-nuclei coil array that enables proton and phosphorus MRI of the human lower extremities with high spatial and temporal resolution. We developed an array with whole-volume coverage of the calf and a phosphorus signal-to-noise ratio of more than double that of a birdcage coil in the gastrocnemius muscles. This enabled the local assessment of phosphocreatine recovery kinetics following a plantar flexion exercise using an efficient sampling scheme with a 6 s temporal resolution. The integrated proton array demonstrated image quality approximately equal to that of a clinical state-of-the-art knee coil, which enabled fat quantification and dynamic blood oxygen level-dependent measurements that reflect microvasculature function. The developed array and time-efficient pulse sequences were combined to create a localized assessment of calf metabolism using phosphorus measurements and vasculature function using proton measurements, which could provide new insights into muscle function.
PMCID:4964597
PMID: 27465636
ISSN: 2045-2322
CID: 2191212
Subject- and resource-specific monitoring and proactive management of parallel radiofrequency transmission
Deniz, Cem M; Alon, Leeor; Brown, Ryan; Zhu, Yudong
PURPOSE: Develop a practical comprehensive package for proactive management of parallel radiofrequency (RF) transmission. METHODS: With a constrained optimization framework and predictive models from a prescan based multichannel calibration, we presented a method supporting design and optimization of parallel RF excitation pulses that accurately obey the forward/reflected peak and average power limits of the RF power amplifiers in parallel transmit imaging experiments and Bloch simulations. Moreover, local SAR limits were incorporated into the parallel RF excitation pulses using electromagnetic field simulations. Virtual transmit coils concept for minimization of reflected power (effecting subject-specific matching) was additionally demonstrated by leveraging experimentally calibrated power models. RESULTS: Incorporation of experimentally calibrated power prediction models resulted in accurate compliance with prescribed hardware and global specific absorption rate (SAR) limits. Incorporation of spatial average 10 g SAR models, facilitated by simplifying numerical approximations, provided assurance of patient safety. RF pulses designed with various constraints demonstrated excellent excitation fidelity-the normalized root-mean-square error of the simulated excitation profiles was 2.6% for the fully constrained pulses, comparable to that of the unconstrained pulses. An RF shimming example showed a reduction of the reflected-to-forward power ratio to 1.7% from a conventional approach's 8.1%. CONCLUSION: Using the presented RF pulse design method, effective proactive management of the multifaceted power and SAR limits was demonstrated in experimental and simulation studies. Magn Reson Med, 2015. (c) 2015 Wiley Periodicals, Inc.
PMCID:4721949
PMID: 26198052
ISSN: 1522-2594
CID: 1683892
Effects of Anatomical Differences on Electromagnetic Fields, SAR, and Temperature Change
Alon, Leeor; Deniz, Cem Murat; Carluccio, Giuseppe; Brown, Ryan; Sodickson, Daniel K; Collins, Christopher M
Electromagnetic field simulations are increasingly used to assure RF safety of patients during MRI exams. In practice, however, tissue property distribution of the patient being imaged is not known, but may be represented with a pre-existing model. Repeatedly, agreement in transmit magnetic (B1 +) field distributions between two geometries has been used to suggest agreement in heating distributions. Here we examine relative effects of anatomical differences on B1 + distribution, Specific Absorption Rate (SAR) and temperature change (DeltaT). Numerical simulations were performed for a single surface coil positioned adjacent a homogeneous phantom and bovine phantom, each with slight geometric variations, and adjacent two different human body models. Experimental demonstration was performed on a bovine phantom using MR thermometry and B1 + mapping. Simulations and experiments demonstrate that B1 + distributions in different samples can be well correlated, while notable difference in maximum SAR and DeltaT occur. This work illustrates challenges associated with utilizing simulations or experiments for RF safety assurance purposes. Reliance on B1 + distributions alone for validation of simulations and/or experiments with a sample or subject for assurance of safety in another should be performed with caution.
PMCID:4847547
PMID: 27134586
ISSN: 1552-5031
CID: 2101092
Dependence of B1+ and B1- Field Patterns of Surface Coils on the Electrical Properties of the Sample and the MR Operating Frequency
Vaidya, Manushka V; Collins, Christopher M; Sodickson, Daniel K; Brown, Ryan; Wiggins, Graham C; Lattanzi, Riccardo
In high field MRI, the spatial distribution of the radiofrequency magnetic ( B1) field is usually affected by the presence of the sample. For hardware design and to aid interpretation of experimental results, it is important both to anticipate and to accurately simulate the behavior of these fields. Fields generated by a radiofrequency surface coil were simulated using dyadic Green's functions, or experimentally measured over a range of frequencies inside an object whose electrical properties were varied to illustrate a variety of transmit [Formula: see text] and receive [Formula: see text] field patterns. In this work, we examine how changes in polarization of the field and interference of propagating waves in an object can affect the B1 spatial distribution. Results are explained conceptually using Maxwell's equations and intuitive illustrations. We demonstrate that the electrical conductivity alters the spatial distribution of distinct polarized components of the field, causing "twisted" transmit and receive field patterns, and asymmetries between [Formula: see text] and [Formula: see text]. Additionally, interference patterns due to wavelength effects are observed at high field in samples with high relative permittivity and near-zero conductivity, but are not present in lossy samples due to the attenuation of propagating EM fields. This work provides a conceptual framework for understanding B1 spatial distributions for surface coils and can provide guidance for RF engineers.
PMCID:5082994
PMID: 27795697
ISSN: 1552-5031
CID: 2296462
High-performance radiofrequency coils for Na MRI: brain and musculoskeletal applications
Wiggins, Graham C; Brown, Ryan; Lakshmanan, Karthik
23 Na RF coil design for brain and MSK applications presents a number of challenges, including poor coil loading for arrays of small coils and SNR penalties associated with providing 1 H capability with the same coil. The basics of RF coil design are described, as well as a review of historical approaches to dual tuning. There follows a review of published high performance coil designs for MSK and brain imaging. Several coil designs have been demonstrated at 7T and 3T which incorporate close-fitting receive arrays and in some cases design features which provide 1 H imaging with little penalty to 23 Na sensitivity. The 'nested coplanar loop' approach is examined, in which small transmit-receive 1 H elements are placed within each 23 Na loop, presenting only a small perturbation to 23 Na performance and minimizing RF shielding issues. Other designs incorporating transmit-receive arrays for 23 Na and 1 H are discussed including a 9.4 T 23 Na / 1 H brain coil. Great gains in 23 Na SNR have been made with many of these designs, but simultaneously achieving high performance for 1H remains elusive
PMCID:4713340
PMID: 26404631
ISSN: 1099-1492
CID: 1787022
A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy
Brown, Ryan; Lakshmanan, Karthik; Madelin, Guillaume; Parasoglou, Prodromos
A dual-nuclei radiofrequency coil array was constructed for phosphorus and proton magnetic resonance imaging and spectroscopy of the human brain at 7T. An eight-channel transceive degenerate birdcage phosphorus module was implemented to provide whole-brain coverage and significant sensitivity improvement over a standard dual-tuned loop coil. A nested eight-channel proton module provided adequate sensitivity for anatomical localization without substantially sacrificing performance on the phosphorus module. The developed array enabled phosphorus spectroscopy, a saturation transfer technique to calculate the global creatine kinase forward reaction rate, and single-metabolite whole-brain imaging with 1.4cm nominal isotropic resolution in 15min (2.3cm actual resolution), while additionally enabling 1mm isotropic proton imaging. This study demonstrates that a multi-channel array can be utilized for phosphorus and proton applications with improved coverage and/or sensitivity over traditional single-channel coils. The efficient multi-channel coil array, time-efficient pulse sequences, and the enhanced signal strength available at ultra-high fields can be combined to allow volumetric assessment of the brain and could provide new insights into the underlying energy metabolism impairment in several neurodegenerative conditions, such as Alzheimer's and Parkinson's diseases, as well as mental disorders such as schizophrenia.
PMCID:4651763
PMID: 26375209
ISSN: 1095-9572
CID: 1779282