Small-Field Dose Measurements Using Plastic Scintillation Detector in Heterogeneous Media

Xue, Jinyu; McKay, Jesse D; Grimm, Jimm; Cheng, Chee-Wai; Berg, Ronald; Grimm, Shu-Ya Lisa; Xu, Qianyi; Subedi, Gopal; Das, Indra J
PURPOSE: To evaluate a plastic scintillation detector for the measurement of small field dosimetry and to verify the accuracy of measured dose in comparison with Monte Carlo calculation in a heterogeneous medium. METHODS: The study is performed with CyberKnife planning and delivery system. The setup consists of a custom made solid lung phantom with the insert of an Exradin W1 scintillation detector or an Exradin A16 ion chamber. The measurement was done for a series of cone sizes from 5 mm to 60 mm, and the dose was calculated by Monte Carlo algorithm in MultiPlan workstation. The difference between measurement and calculation was reported. RESULTS: Our preliminary results demonstrated the applicability of plastic scintillation detectors in the measurement of small field dosimetry in a heterogeneous medium. The difference between the calculated and measured output factors was less than 3% for all cone sizes from 60 mm down to 5 mm. Without any corrections, the measured dose from the scintillation detector calibrated to the ion chamber reading was also within 3% of the Monte Carlo calculation in the lung phantom for cone sizes 20 mm or larger. CONCLUSIONS: Small field dosimetry is particularly relevant to stereotactic radiation treatment. The accuracy of dose calculation for small static beams is critical to dose planning so would potentially affect the treatment outcomes in an heterogeneous medium. Our results have shown good agreement with plastic scintillation detector in both homogeneous and heterogeneous medium
PMID: 28398596
ISSN: 2473-4209
CID: 2528192

Validation of Treatment Planning Dose Calculations: Experience Working with MPPG 5.a [Meeting Abstract]

Xue, J.; Park, J.; Kim, L.; Balter, P.; Ohrt, J.; Kirsner, S.; Wang, C.; Ibbott, G.
ISI:000402319800009
ISSN: 0094-2405
CID: 3542812

Simple Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy of the Thorax: A Pooled Analysis of 88 Studies

Zhao, Jing; Yorke, Ellen D; Li, Ling; Kavanagh, Brian D; Li, X Allen; Das, Shiva; Miften, Moyed; Rimner, Andreas; Campbell, Jeffrey; Xue, Jinyu; Jackson, Andrew; Grimm, Jimm; Milano, Michael T; Spring Kong, Feng-Ming
PURPOSE: To study the risk factors for radiation-induced lung toxicity (RILT) after stereotactic body radiation therapy (SBRT) of the thorax. METHODS AND MATERIALS: Published studies on lung toxicity in patients with early-stage non-small cell lung cancer (NSCLC) or metastatic lung tumors treated with SBRT were pooled and analyzed. The primary endpoint was RILT, including pneumonitis and fibrosis. Data of RILT and risk factors were extracted from each study, and rates of grade 2 to 5 (G2+) and grade 3 to 5 (G3+) RILT were computed. Patient, tumor, and dosimetric factors were analyzed for their correlation with RILT. RESULTS: Eighty-eight studies (7752 patients) that reported RILT incidence were eligible. The pooled rates of G2+ and G3+ RILT from all 88 studies were 9.1% (95% confidence interval [CI]: 7.15-11.4) and 1.8% (95% CI: 1.3-2.5), respectively. The median of median tumor sizes was 2.3 (range, 1.4-4.1) cm. Among the factors analyzed, older patient age (P=.044) and larger tumor size (the greatest diameter) were significantly correlated with higher rates of G2+ (P=.049) and G3+ RILT (P=.001). Patients with stage IA versus stage IB NSCLC had significantly lower risks of G2+ RILT (8.3% vs 17.1%, odds ratio = 0.43, 95% CI: 0.29-0.64, P<.0001). Among studies that provided detailed dosimetric data, the pooled analysis demonstrated a significantly higher mean lung dose (MLD) (P=.027) and V20 (P=.019) in patients with G2+ RILT than in those with grade 0 to 1 RILT. CONCLUSIONS: The overall rate of RILT is relatively low after thoracic SBRT. Older age and larger tumor size are significant adverse risk factors for RILT. Lung dosimetry, specifically lung V20 and MLD, also significantly affect RILT risk.
PMCID:5541363
PMID: 27325482
ISSN: 1879-355x
CID: 2281972

Stereotactic Radiosurgery for Poor Performance Status Patients

Kubicek, Gregory J; Turtz, Alan; Xue, Jinyu; Patel, Ashish; Richards, Gregory; LaCouture, Tamara; Cappelli, Louis; Diestelkamp, Tim; Saraiya, Piya; Bexon, Anne; Lerman, Nati; Goldman, Howard Warren
PURPOSE: Patients with poor performance status (PS), usually defined as a Karnofsky Performance Status of 60 or less, were not eligible for randomized stereotactic radiosurgery (SRS) studies, and many guidelines suggest that whole-brain radiation therapy (WBRT) is the most appropriate treatment for poor PS patients. METHODS AND MATERIALS: In this retrospective review of our SRS database, we identified 36 patients with PS of 60 or less treated with SRS for central nervous system (CNS) metastatic disease. PS, as defined by the Karnofsky Performance Status, was 60 (27 patients), 50 (8 patients), or 40 (1 patient). The median number of CNS lesions treated was 3. RESULTS: Median overall survival (OS) was 7.2 months (range, 0.73-25.6 months). Fifteen patients (41%) were alive at 6 months, and 6 patients (16.6%) were alive at 1 year. There was no difference in OS in patients who underwent previous WBRT. There were no local failures or cases of radiation toxicity. Distant CNS failures were seen in 9 patients (25%). CONCLUSIONS: Our patients with poor PS had reasonable median OS and relatively low distant CNS failure rates. Patients in this patient population may be ideal candidates for SRS compared with WBRT given the low incidence of distant failure over their remaining lives and the favorable logistics of single-fraction treatment for these patients with debility and their caregivers.
PMID: 27113565
ISSN: 1879-355x
CID: 2281982

Estimated Risk Level of Unified Stereotactic Body Radiation Therapy Dose Tolerance Limits for Spinal Cord

Grimm, Jimm; Sahgal, Arjun; Soltys, Scott G; Luxton, Gary; Patel, Ashish; Herbert, Scott; Xue, Jinyu; Ma, Lijun; Yorke, Ellen; Adler, John R; Gibbs, Iris C
A literature review of more than 200 stereotactic body radiation therapy spine articles from the past 20 years found only a single article that provided dose-volume data and outcomes for each spinal cord of a clinical dataset: the Gibbs 2007 article (Gibbs et al, 2007(1)), which essentially contains the first 100 stereotactic body radiation therapy (SBRT) spine treatments from Stanford University Medical Center. The dataset is modeled and compared in detail to the rest of the literature review, which found 59 dose tolerance limits for the spinal cord in 1-5 fractions. We partitioned these limits into a unified format of high-risk and low-risk dose tolerance limits. To estimate the corresponding risk level of each limit we used the Gibbs 2007 clinical spinal cord dose-volume data for 102 spinal metastases in 74 patients treated by spinal radiosurgery. In all, 50 of the patients were previously irradiated to a median dose of 40Gy in 2-3Gy fractions and 3 patients developed treatment-related myelopathy. These dose-volume data were digitized into the dose-volume histogram (DVH) Evaluator software tool where parameters of the probit dose-response model were fitted using the maximum likelihood approach (Jackson et al, 1995(3)). Based on this limited dataset, for de novo cases the unified low-risk dose tolerance limits yielded an estimated risk of spinal cord injury of
PMCID:4990135
PMID: 27000514
ISSN: 1532-9461
CID: 2281992

Small Bowel Dose Tolerance for Stereotactic Body Radiation Therapy

LaCouture, Tamara A; Xue, Jinyu; Subedi, Gopal; Xu, Qianyi; Lee, Justin T; Kubicek, Gregory; Asbell, Sucha O
Inconsistencies permeate the literature regarding small bowel dose tolerance limits for stereotactic body radiation therapy (SBRT) treatments. In this review, we organized these diverse published limits with MD Anderson at Cooper data into a unified framework, constructing the dose-volume histogram (DVH) Risk Map, demonstrating low-risk and high-risk SBRT dose tolerance limits for small bowel. Statistical models of clinical data from 2 institutions were used to assess the safety spectrum of doses used in the exposure of the gastrointestinal tract in SBRT; 30% of the analyzed cases had vascular endothelial growth factor inhibitors (VEGFI) or other biological agents within 2 years before or after SBRT. For every dose tolerance limit in the DVH Risk Map, the probit dose-response model was used to estimate the risk level from our clinical data. Using the current literature, 21Gy to 5cc of small bowel in 3 fractions has low toxicity and is reasonably safe, with 6.5% estimated risk of grade 3 or higher complications, per Common Terminology Criteria for Adverse Events version 4.0. In the same fractionation for the same volume, if lower risk is required, 16.2Gy has an estimated risk of only 2.5%. Other volumes and fractionations are also reviewed; for all analyzed high-risk small bowel limits, the risk is 8.2% or less, and the low-risk limits have 4% or lower estimated risk. The results support current clinical practice, with some possibility for dose escalation.
PMID: 27000513
ISSN: 1532-9461
CID: 2282002

Validity of Current Stereotactic Body Radiation Therapy Dose Constraints for Aorta and Major Vessels

Xue, Jinyu; Kubicek, Gregory; Patel, Ashish; Goldsmith, Benjamin; Asbell, Sucha O; LaCouture, Tamara A
Understanding dose constraints for critical structures in stereotactic body radiation therapy (SBRT) is essential to generate a plan for optimal efficacy and safety. Published dose constraints are derived by a variety of methods, including crude statistics, actuarial analysis, modeling, and simple biologically effective dose (BED) conversion. Many dose constraints reported in the literature are not consistent with each other, secondary to differences in clinical and dosimetric parameters. Application of a dose constraint without discriminating the variation of all the factors involved may result in suboptimal treatment. This issue of Seminars in Radiation Oncology validates dose tolerance limits for 10 critical anatomic structures based on dose response modeling of clinical outcomes data to include detailed dose-volume metrics. This article presents a logistic dose-response model for aorta and major vessels based on 238 cases from the literature in addition to 387 cases from MD Anderson Cancer Center at Cooper University Hospital, for a total of 625 cases. The Radiation Therapy Oncology Group (RTOG) 0813 dose-tolerance limit of Dmax = 52.5Gy in 5 fractions was found to have a 1.2% risk of grade 3-5 toxicity, and the Timmerman 2008 limit of Dmax = 45Gy in 3 fractions had 2.3% risk. From the model, the 1% and 2% risk levels for D4cc, D1cc, and D0.5cc are also provided in 1-5 fractions, in the form of a dose-volume histogram (DVH) Risk Map.
PMID: 27000510
ISSN: 1532-9461
CID: 2282012

Introduction and Clinical Overview of the DVH Risk Map

Asbell, Sucha O; Grimm, Jimm; Xue, Jinyu; Chew, Meng-Sang; LaCouture, Tamara A
Radiation oncologists need reliable estimates of risk for various fractionation schemes for all critical anatomical structures throughout the body, in a clinically convenient format. Reliable estimation theory can become fairly complex, however, and estimates of risk continue to evolve as the literature matures. To navigate through this efficiently, a dose-volume histogram (DVH) Risk Map was created, which provides a comparison of radiation tolerance limits as a function of dose, fractionation, volume, and risk level. The graphical portion of the DVH Risk Map helps clinicians to easily visualize the trends, whereas the tabular portion provides quantitative precision for clinical implementation. The DVH Risk Map for rib tolerance from stereotactic ablative body radiotherapy (SABR) and stereotactic body radiation therapy (SBRT) is used as an example in this overview; the 5% and 50% risk levels for 1-5 fractions for 5 different volumes are given. Other articles throughout this issue of Seminars in Radiation Oncology present analysis of new clinical datasets including the DVH Risk Maps for other anatomical structures throughout the body.
PMID: 27000504
ISSN: 1532-9461
CID: 2282022

Overview of dosimetric and biological perspectives on radiosurgery of multiple brain metastases in comparison with whole brain radiotherapy

Xue, Jinyu; LaCouture, Tamara; Grimm, Jimm; Goldman, H Warren; Ibbott, Geoffrey S; Yorke, Ellen; Kubicek, Gregory J
Purpose/UNASSIGNED:Treatment option of stereotactic radiosurgery versus whole brain radiotherapy for multiple brain metastases (>10) is an ongoing debate. Detailed dosimetric and biological information are presented in this study to investigate the possible clinical outcomes.Materials and Methods: Nine patients with multiple brain metastases (11-25) underwent stereotactic radiosurgery. Whole brain radiotherapy plans are retrospectively designed with the same MR image set and the same structure set for each patient using the standard opposing lateral beams and fractionation (3 Gy × 10).Physical doses and biologically effective doses are calculated for each lesion target and the CNS normal tissues and they are compared between whole brain radiotherapy and stereotactic radiosurgery in the context of clinical efficacy and published toxicities. Results/UNASSIGNED:Tumor biologically effective dose is higher in radiosurgery than in whole brain radiotherapy by factors of 3.2-5.3 in maximum dose and of 2.4-3.1 in mean dose. Biologically effective mean dose in radiosurgery is 1.3-34.3% for normal brain, 0.7-31.6% for brainstem, 0.5-5.7% for chiasm, 0.2-5.7% for optic nerves and 0.6-18.1% for hippocampus of that in whole brain radiotherapy over nine cases presented here. We also presented the dose-volume relationship for normal brain to address the dosimetric concerns in radiosurgery. Conclusions/UNASSIGNED:Dose-volume metrics presented in this study are essential to understanding the safety and efficacy of whole brain radiotherapy and/or radiosurgery for multiple brain metastases. Whole brain radiotherapy has resulted in higher incidence of radiation-related toxicities than radiosurgery. Even for patients with more than 10 brain metastases, the CNS normal tissues receive significantly lower doses in radiosurgery. Mean normal brain dose in SRS is found to correlate with the total volume of lesions rather than the number of lesions treated.
PMCID:5675494
PMID: 29296410
ISSN: 2156-4639
CID: 3663892

Testing the Limitations of a Photon Dose Algorithm in Commissioning [Meeting Abstract]

Xue, J; Choi, M; Park, J; LaCouture, T; Ibbott, G
ISI:000356998302430
ISSN: 0094-2405
CID: 2291982