Evaluation of instrumentation and pedicle screw design for posterior lumbar fixation: A pre-clinical in vivo/ex vivo ovine model
Witek, Lukasz; Parente, Paulo Eduardo Lima; Torroni, Andrea; Greenberg, Michael; Nayak, Vasudev Vivekanand; Hacquebord, Jacques Henri; Coelho, Paulo G
BACKGROUND/UNASSIGNED:" osseodensification rotary drilling compacts the bone fragments into the osteotomy walls, creating nucleating sites for regeneration. METHODS/UNASSIGNED:This study aimed to compare both manual versus rotary Osseodensification (OD) instrumentation as well as two different pedicle screw thread designs in a controlled split animal model in posterior lumbar stabilization to determine the feasibility and potential advantages of each variable with respect to mechanical stability and histomorphology. A total of 164 single thread (82 per thread configuration), pedicle screws (4.5 × 35 mm) were used for the study. Each animal received eight pedicles (four per thread design) screws, which were placed in the lumbar spine of 21 adult sheep. One side of the lumbar spine underwent rotary osseodensification instrumentation, while the contralateral underwent conventional, hand, instrumentation. The animals were euthanized after 6- and 24-weeks of healing, and the vertebrae were removed for biomechanical and histomorphometric analyses. Pullout strength and histologic analysis were performed on all harvested samples. RESULTS/UNASSIGNED: = 0.026) greater pullout strength (1060.6 N ± 181) relative to hand instrumentation (769.3 N ± 181) at the 24-week healing time point. Histomorphometric analysis exhibited significantly higher degrees of bone to implant contact for the rotary instrumentation only at the early healing time point (6 weeks), whereas bone area fraction occupancy was statistically higher for rotary instrumentation at both healing times. The levels of soft tissue infiltration were lower for pedicle screws placed in osteotomies prepared using OD instrumentation relative to hand instrumentation, independent of healing time. CONCLUSION/UNASSIGNED:The rotary instrumentation yielded enhanced mechanical and histologic results relative to the conventional hand instrumentation in this lumbar spine stabilization model.
PMCID:10285755
PMID: 37361331
ISSN: 2572-1143
CID: 5540112
The presence of 3D printing in orthopedics: A clinical and material review
Rodriguez Colon, Ricardo; Nayak, Vasudev Vivekanand; Parente, Paulo E L; Leucht, Philipp; Tovar, Nick; Lin, Charles C; Rezzadeh, Kevin; Hacquebord, Jacques H; Coelho, Paulo G; Witek, Lukasz
The field of additive manufacturing, 3D printing (3DP), has experienced an exponential growth over the past four decades, in part due to increased accessibility. Developments including computer-aided design and manufacturing, incorporation of more versatile materials, and improved printing techniques/equipment have stimulated growth of 3DP technologies within various industries, but most specifically the medical field. Alternatives to metals including ceramics and polymers have been garnering popularity due to their resorbable properties and physiologic similarity to extracellular matrix. 3DP has the capacity to utilize an assortment of materials and printing techniques for a multitude of indications, each with their own associated benefits. Within the field of medicine, advances in medical imaging have facilitated the integration of 3DP. In particular, the field of orthopedics has been one of the earliest medical specialties to implement 3DP. Current indications include education for patients, providers, and trainees, in addition to surgical planning. Moreover, further possibilities within orthopedic surgery continue to be explored, including the development of patient-specific implants. This review aims to highlight the use of current 3DP technology and materials by the orthopedic community, and includes comments on current trends and future direction(s) within the field.
PMID: 35634867
ISSN: 1554-527x
CID: 5235812
Giant Increase of Hardness in Silicon Carbide by Metastable Single Layer Diamond-Like Coating
Rejhon, Martin; Zhou, Xinliu; Lavini, Francesco; Zanut, Alessandra; Popovich, Filip; Schellack, Lorenzo; Witek, Lukasz; Coelho, Paulo; Kunc, Jan; Riedo, Elisa
Silicon carbide (SiC) is one of the hardest known materials. Its exceptional mechanical properties combined with its high thermal conductivity make it a very attractive material for a variety of technological applications. Recently, it is discovered that two-layer epitaxial graphene films on SiC can undergo a pressure activated phase transition into a sp3 diamene structure at room temperature. Here, it is shown that epitaxial graphene films grown on SiC can increase the hardness of SiC up to 100% at low loads (up to 900 µN), and up to 30% at high loads (10 mN). By using a Berkovich diamond indenter and nanoindentation experiments, it is demonstrated that the 30% increase in hardness is present even for indentations depths of 175 nm, almost three hundred times larger than the graphene film thickness. The experiments also show that the yield point of SiC increases up to 77% when the SiC surface is coated with epitaxial graphene. These improved mechanical properties are explained with the formation of diamene under the indenter's pressure.
PMCID:9951309
PMID: 36599685
ISSN: 2198-3844
CID: 5434292
Advancements and Innovations in OMFS, ENT, and Facial Plastic Surgery
Melville, James C.; Coelho, Paulo G.; Young, Simon
[S.l.] : Springer International Publishing, 2023
Extent: 1 v.
ISBN: 9783031320989
CID: 5717512
Effect of High-radiant Emittance and Short Curing Time on Polymerization Shrinkage Vectors of Bulk Fill Composites
Hirata, R; Sampaio, C S; Atria, P J; Giannini, M; Coelho, P G; Yamaguchi, S
PURPOSE/OBJECTIVE:To evaluate the effect of short curing time using a high-radiant emittance light on polymerization shrinkage vectors in different consistency bulk-fill composites (BFRCs) using micro-computed tomography. METHODS AND MATERIALS/METHODS:Radiopaque zirconia fillers were homogeneously incorporated and functioned as radiopaque tracers into two regular-paste: TBFill (Tetric EvoCeram Bulk Fill) and TPFill (Tetric PowerFill), and two flowable (n=6): TBFlow (Tetric EvoFlow Bulk Fill) and TPFlow (Tetric PowerFlow) resin composites. Class I cavities (4 mm depth × 4 mm length × 4 mm width) were 3D-printed and filled in a single increment: TBFill and TBFlow were light-activated using a Bluephase Style 20i (10 seconds in high-mode); TPFill and TPFlow were light-activated using a Bluephase PowerCure (three seconds). The same adhesive system (Adhese Universal) was used for all groups. Microcomputed tomography scans were obtained before and after light-activation. Filler particle movement was identified by polymerization shrinkage vectors at five depths (from 0-4 mm): top, top-middle, middle, middle-bottom and bottom. RESULTS:TPFlow showed the lowest total vector displacement, followed by TBFlow, TBFill and TPFill, significantly different among each other (p<0.05). Generally, BFRCs showed decreased vector displacement with increased depth, and higher displacement at the top-surface (p<0.05). Qualitative analysis showed a similar pattern of vector magnitude and displacement for groups TBFill and TPFill, with displacement vectors on occlusal (top) surfaces toward the center of the restoration from the top to middle areas, and relatively limited displacement at the bottom. TBFlow and TPFlow showed more displacement on the occlusal (top). CONCLUSIONS:Short curing time with high-radiant emittance on fast-curing BFRCs was shown to be a feasible option in terms of vector displacement. Flowable BFRCs presented lower vector displacement than their regular-viscosity versions.
PMID: 36534034
ISSN: 1559-2863
CID: 5409252
The New Norm: Examining Quality of Life with Trigeminal Nerve Deficits and New Standards of Nerve Repair-A Systematic Review and Meta-analysis
Chapter by: Manon, Victoria A.; Tran, Huy Q.; Tursun, Ramzey; Coelho, Paulo G.; Witek, Lukasz; Wong, Mark E.; Young, Simon; Melville, James C.
in: Advancements and Innovations in OMFS, ENT, and Facial Plastic Surgery by
[S.l.] : Springer International Publishing, 2023
pp. 323-332
ISBN: 9783031320989
CID: 5717522
Evaluation of instrumentation and pedicle screw design for posterior lumbar fixation: A pre-clinical in vivo/ex vivo ovine model
Witek, Lukasz; Parente, Paulo Eduardo Lima; Torroni, Andrea; Greenberg, Michael; Nayak, Vasudev Vivekanand; Hacquebord, Jacques Henri; Coelho, Paulo G. G.
ISI:000915953900001
ISSN: 2572-1143
CID: 5439782
An in vivo preclinical study assessing biocompatibility of Pd-based bulk metallic glass
Witek, Lukasz; Vivekanand Nayak, Vasudev; Rodriguez Colon, Ricardo; Torroni, Andrea; Demetriou, Marios D; Coelho, Paulo G
BACKGROUND:The bulk metallic glass (BMG), Pd79Ag3.5P6Si9.5Ge2, has a high fracture toughness and has been found to accommodate post-yield stress, unlike most other BMG. Moreover, due to its greater noble gas composition it has a intrinsic corrosion resistance, ideal for dental and orthopedic implants. OBJECTIVE:This present study aimed to evaluate the in vivo application of Pd79Ag3.5P6Si9.5Ge2 in a large translational sheep model to assess its efficacy to be utilized as an endosteal device. METHODS:Twelve implants in the form of cylindrical rods (3 mm in diameter) were produced through rapid quenching. Each sheep (n = 12) received one osteotomy in the mandibular region using rotary instrumentation, which was subsequently filled with Pd79Ag3.5P6Si9.5Ge2. After 6- and 24-weeks the animals were euthanized, and samples collected en bloc to conduct histomorphometric analysis. The level/degrees of osseointegration were assessed through bone-to-implant contact (BIC). RESULTS:Favorable BIC was observed with fibrous connective tissue layers at both 6- and 24-weeks. Bone along with interfacial remodeling was observed in proximity with the metallic glass surface at 6 weeks with higher degrees of bone organization being observed at the later healing time, 24 weeks. CONCLUSIONS:The introduced BMG revealed potential to serve as an alternative biomaterial to commonly used Ti alloys given its unique combination of toughness and strength.
PMID: 36278332
ISSN: 1878-3619
CID: 5359252
3D printed mesoporous bioactive glass, bioglass 45S5, and β-TCP scaffolds for regenerative medicine: A comparative in vitro study
Pacheco, Maria; Ricci, John L; Mijares, Dindo; Bromage, Timothy G; Rabieh, Sasan; Coelho, Paulo G; Witek, Lukasz
BACKGROUND:While autografts to date remain the "gold standard" for bone void fillers, synthetic bone grafts have garnered attention due to their advantages such as ability to be tailored in terms of its physical and chemical properties. Bioactive glass (BG), an inorganic material, has the capacity to form a strong bond with bone by forming a bone-like apatite surface, enhancing osteogenesis. Coupled with three-dimensional printing it is possible to maximize bone regenerative properties of the BG. OBJECTIVE:The objective of this study was to synthesize and characterize 3D printed mesoporous bioactive glass (MBG), BG 45S5, and compare to β-Tricalcium phosphate (β-TCP) based scaffolds; test cell viability and osteogenic differentiation on human osteoprogenitor cells in vitro. METHODS:MBG, BG 45S5, and β-TCP were fabricated into colloidal gel suspensions, tested with a rheometer, and manufactured into scaffolds using a 3D direct-write micro-printer. The materials were characterized in terms of microstructure and composition with Thermogravimetric Analyzer/Differential Scanning Calorimeter (TGA/DSC), Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffraction (XRD), Micro-Computed Tomography (μ-CT), Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), and Mattauch-Herzog-Inductively Coupled Plasma-Mass Spectrometry (MH-ICP-MS). RESULTS:Scaffolds were tested for cell proliferation and osteogenic differentiation using human osteoprogenitor cells. Osteogenic media was used for differentiation, and immunocytochemistry for osteogenic markers Runx-2, Collagen-I, and Osteocalcin. The cell viability results after 7 days of culture yielded significantly higher (p < 0.05) results in β-TCP scaffolds compared to BG 45S5 and MBG groups. CONCLUSION/CONCLUSIONS:All materials expressed osteogenic markers after 21 days of culture in expansion and osteogenic media.
PMID: 36744331
ISSN: 1878-3619
CID: 5434832
In vitro assessment of the effect of luting agents, abutment height, and fatigue on the retention of zirconia crowns luted to titanium base implant abutments
Strazzi-Sahyon, Henrico B.; Bergamo, Edmara T. P.; Gierthmuehlen, Petra C.; Lopes, Adolfo C. O.; Alves, Larissa M. M.; Jalkh, Ernesto B. Benalcazar; Zahoui, Abbas; Coelho, Paulo G.; de Carvalho, Alexandre M.; Bonfante, Estevam A.
ISI:001111792200001
ISSN: 0022-3913
CID: 5591242