101


Factors that may determine the targeting accuracy of image-guided radiosurgery

Subedi, Gopal; Karasick, Todd; Grimm, Jimm; Jain, Sheena; Xue, Jinyu; Xu, Qianyi; Chen, Yan; Asbell, Sucha; Pahlajani, Niraj; LaCouture, Tamara
PURPOSE: The AAPM TG-135 report is a landmark recommendation for the quality assurance (QA) of image-guided robotic radiosurgery. The purpose of this paper is to present results pertaining to intentionally offsetting the phantom as recommended by TG-135 and to present data on targeting algorithm accuracy as a function of imager parameters in less than ideal circumstances, which had not been available at the time of publication of TG-135. METHODS: All tests in this study were performed at the Cooper University Hospital CyberKnife Center in Mt. Laurel, NJ. For intentional offsets, initial tests were performed on the Accuray-supplied anthropomorphic head and neck phantom, whereas for subsequent tests, the Accuray-supplied alignment quality assurance (AQA) phantom was used. To simulate the effects of imager parameters for larger patients, slabs of Blue Water (Standard Imaging, Inc., Middleton, WI) were added to attenuate the x-ray images in some of the tests. In conjunction with attenuated x-ray tests, the number of fiducials was varied by systematically deselecting them one at a time at the CyberKnife console. RESULTS: Tests using the AQA phantom verified that submillimeter alignments were consistently achieved even with intentional shifts and rotations of up to 10.0 mm and 1.0 degrees , respectively. An analysis of 17 months of daily QA alignment tests showed that submillimeter alignments were achieved more than 99% of the time even with such intentional shifts and rotations of the phantom. When additional slabs of Blue Water were added to simulate patient attenuation of the x-ray images, targeting errors could be induced depending on imager parameters and the amount of Blue Water used. A series of consecutive tests showed that two helpful variables to ensure good accuracy of the system were (1) the fiducial extraction confidence level (FECL) system parameter and (2) the number of targeted fiducials. When fewer than four fiducials were used, the FECL reported by the CyberKnife was sometimes high even when a false lock occurred, so using multiple fiducials helped to ensure reliable targeting. CONCLUSIONS: Radiosurgery requires the highest degree of targeting accuracy, and in our experience, the CyberKnife has been able to maintain submillimeter accuracy consistently. It has been verified that our CyberKnife can correct for phantom shifts of up to 10.0 mm and rotations of up to 1.0 degrees . It has also been discovered that false locks are more likely to occur with a single fiducial than with multiple fiducials. Although targeting accuracy can only be measured on a phantom, the insight gained from analyzing the QA tests can help us in devising better strategies for achieving the best treatment for our patients.
PMID: 26429275
ISSN: 0094-2405
CID: 2282032

Dosimetric and Mechanical Characteristics of Elekta Infinity LINAC with Agility MLC [Meeting Abstract]

Park, J.; Xu, Q.; Xue, J.; Zhai, Y.; An, L.; Chen, Y.
ISI:000438759602270
ISSN: 0094-2405
CID: 3542982

Simple Clinical Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy in Lung Cancer: A Pooled Analysis of 70 Studies [Meeting Abstract]

Zhao, J; Ling, L; Yorke, ED; Milano, MT; Liu, W; Kavanagh, B; Li, A; Andy, J; Lawrence, M; Miften, M; Rimner, A; Timothy, S; Xue, J; Grimm, J; Kong, F
ISI:000346413500177
ISSN: 1879-355x
CID: 2288442

Simple Clinical Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy in Lung Cancer: A Pooled Analysis of 70 Studies [Meeting Abstract]

Zhao, J; Ling, L; Yorke, ED; Milano, MT; Liu, W; Kavanagh, B; Li, A; Andy, J; Lawrence, M; Miften, M; Rimner, A; Timothy, S; Xue, J; Grimm, J; Kong, F
ISI:000342331400136
ISSN: 1879-355x
CID: 2288452

Biological implications of whole-brain radiotherapy versus stereotactic radiosurgery of multiple brain metastases

Xue, Jinyu; Kubicek, Gregory J; Grimm, Jimm; LaCouture, Tamara; Chen, Yan; Goldman, H Warren; Yorke, Ellen
OBJECT: The efficacy and safety of treatment with whole-brain radiotherapy (WBRT) or with stereotactic radiosurgery (SRS) for multiple brain metastases (> 10) are topics of ongoing debate. This study presents detailed dosimetric and biological information to investigate the possible clinical outcomes of these 2 modalities. METHODS: Five patients with multiple brain metastases (n = 11-23) underwent SRS. Whole-brain radiotherapy plans were retrospectively designed with the same MR image set and the same structure set for each patient, using the standard opposing lateral beams and fractionation (3 Gy x 10). Physical radiation doses and biologically effective doses (BEDs) in WBRT and SRS were calculated for each lesion target and for the normal brain tissues for comparison of the 2 modalities in the context of clinical efficacy and published toxicities. RESULTS: The BEDs targeted to the tumor were higher in SRS than in WBRT by factors ranging from 2.4- to 3.0- fold for the mean dose and from 3.2- to 5.3-fold for the maximum dose. In the 5 patients, mean BEDs in SRS (calculated as percentages of BEDs in WBRT) were 1.3%-34.3% for normal brain tissue, 0.7%-31.6% for the brainstem, 0.5%-5.7% for the chiasm, 0.2%-5.7% for optic nerves, and 0.6%-18.1% for the hippocampus. CONCLUSIONS: The dose-volume metrics presented in this study were essential to understanding the safety and efficacy of WBRT and SRS for multiple brain metastases. Whole-brain radiotherapy results in a higher incidence of radiation-related toxicities than SRS. Even in patients with > 10 brain metastases, the normal CNS tissues receive significantly lower doses in SRS. The mean normal brain dose in SRS correlated with the total volume of the lesions rather than with the number of lesions treated.
PMID: 25434938
ISSN: 1933-0693
CID: 2282042

Dosimetric Uncertainty Induced by CT-MRI Fusion in Prostate Treatment Planning [Meeting Abstract]

Chen, X.; Xue, J.; Fan, J.; Chen, L.; Ma, C.
ISI:000336849901026
ISSN: 0094-2405
CID: 3542772

Real-Time Beam-Eye-View Monitoring of Prostate Motion During IMRT: A Moving Phantom Study with Cine-EPID Imaging [Meeting Abstract]

Chen, X.; Fan, J.; Xue, J.; Chen, L.; Wang, L.; Ma, C.
ISI:000336849902554
ISSN: 0094-2405
CID: 3542782

Implications of Radiobiological Bath and Shower Effects On Brainstem Dose Tolerance [Meeting Abstract]

Grimm, J; Chen, A; Ying, W; Xue, J
ISI:000336849901331
ISSN: 0094-2405
CID: 2288462

Complication probability for radiation pneumonitis (RP) after stereotactic body radiotherapy (SBRT)

Grimm, Jimm; Palma, David; Senan, Suresh; Xue, Jinyu
ORIGINAL:0011615
ISSN: 2156-4639
CID: 2289112

Estimated risk level of unified SbRT dose tolerance limits for spinal cord [Meeting Abstract]

Gibbs, IC; Grimm, J; Luxton, G; Soltys, SG; Sahgal, A; Patel, A; Herbert, S; Xue, J; Ma, L; Adler, JR
ORIGINAL:0011617
ISSN: 2156-4639
CID: 2289132