Dose-volume Effects on Brainstem Dose Tolerance in Radiosurgery [Meeting Abstract]
Xue, J; Grimm, J; Lesley, H; LaCouture, T; Xu, Q; Goldman, W
ISI:000296411701847
ISSN: 0360-3016
CID: 2289042
Do We Know the Acute Skin Tolerance Dose for SBRT Hypofractionated Radiation Therapy? [Meeting Abstract]
Asbell, Sucha; LaCouture, Tamara; Kramer, Noel; Pahlajani, Niraj; Xue, Jinyu; Grimm, Jimm
ISI:000288782900035
ISSN: 0277-3732
CID: 2289072
Dose tolerance limits and dose volume histogram evaluation for stereotactic body radiotherapy
Grimm, Jimm; LaCouture, Tamara; Croce, Raymond; Yeo, Inhwan; Zhu, Yunping; Xue, Jinyu
Almost 20 years ago, Emami et al. presented a comprehensive set of dose tolerance limits for normal tissue organs to therapeutic radiation, which has proven essential to the field of radiation oncology. The paradigm of stereotactic body radiotherapy (SBRT) has dramatically different dosing schemes but, to date, there has still been no comprehensive set of SBRT normal organ dose tolerance limits. As an initial step toward that goal, we performed an extensive review of the literature to compare dose limits utilized and reported in existing publications. The impact on dose tolerance limits of some key aspects of the methods and materials of the various authors is discussed. We have organized a table of 500 dose tolerance limits of normal structures for SBRT. We still observed several dose limits that are unknown or not validated. Data for SBRT dose tolerance limits are still preliminary and further clinical trials and validation are required. This manuscript presents an extensive collection of normal organ dose tolerance limits to facilitate both clinical application and further research.
PMID: 21587185
ISSN: 1526-9914
CID: 2282092
A Database for Dose Tolerance Limits in Hypofractionated SBRT [Meeting Abstract]
Xue, J.; LaCouture, T.; Chew, M.; Pahlajani, N.; Grimm, J.
ISI:000411513400055
ISSN: 0094-2405
CID: 3542832
Preliminary Estimates of Adverse Event Probability for Selected Critical Anatomical Structures in SBRT [Meeting Abstract]
Grimm, J.; Xue, J.; Asbell, S.; Pahlajani, N.; Chew, M.; Karasick, T.; LaCouture, T.
ISI:000411513600026
ISSN: 0094-2405
CID: 3542842
Comparison of RTOG 0618, 0813, 0915, and Accuray STARS SBRT Lung Protocols [Meeting Abstract]
Grimm, J.; Xue, J.; Asbell, S.; Pahlajani, N.; Chen, Y.; Croce, R.; Chew, M.; Karasick, T.; LaCouture, T.
ISI:000411513600041
ISSN: 0094-2405
CID: 3542852
A Database of Online Registry for Dose Tolerance Limits in Hypofractionated SBRT [Meeting Abstract]
Xue, J; LaCouture, T; Chew, M; Pahlajani, N; Hughes, L; Kramer, N; Asbell, S; Grimm, J
ISI:000288775701824
ISSN: 0360-3016
CID: 2289082
Regression Analysis of the Dose Tolerance Limits of Some Critical Structures in Hypofractionated SBRT [Meeting Abstract]
Chew, M; Grimm, J; Chen, Y; LaCouture, T; Kramer, N; Asbell, S; Hughes, LA; Pahlajani, N; Xue, J
ISI:000288775701760
ISSN: 0360-3016
CID: 2289142
A quality assurance method with submillimeter accuracy for stereotactic linear accelerators
Grimm, Jimm; Grimm, Shu-Ya Lisa; Das, Indra J; Zhu, Yunping; Yeo, Inhwan; Xue, Jinyu; Simpson, Larry; Jacob, Dayee; Sarkar, Abhirup
The Stereotactic Alignment for Linear Accelerator (S. A. Linac) system is developed to conveniently improve the alignment accuracy of a conventional linac equipped with stereotactic cones. From the Winston-Lutz test, the SAlinac system performs three-dimensional (3D) reconstruction of the quality assurance (QA) ball coordinates with respect to the radiation isocenter, and combines this information with digital images of the laser target to determine the absolute position of the room lasers. A handheld device provides near-real-time repositioning advice to enable the user to align the QA ball and room lasers to within 0.25 mm of the centroid of the radiation isocenter. The results of 37 Winston-Lutz tests over 68 days showed that the median 3D QA ball alignment error was 0.09 mm, and 97% of the time the 3D error was = 0.25 mm. All 3D isocentric errors in the study were 0.3 mm or less. The median x and y laser alignment coordinate error was 0.09 mm, and 94% of the time the x and y laser error was = 0.25 mm. A phantom test showed that the system can make submillimeter end-to-end accuracy achievable, making a conventional linac a "Submillimeter Knife".
PMID: 21330986
ISSN: 1526-9914
CID: 2062602
Unified Dose Tolerance Limits for SBRT [Meeting Abstract]
Grimm, J.; LaCouture, T.; Zhu, Y.; Xue, J.; Yeo, I.; Croce, R.; Hughes, S.
ISI:000411579400013
ISSN: 0094-2405
CID: 3542922