Searched for: in-biosketch:yes
person:xuej01
Dose Tolerance Limits and DVH Evaluation for SBRT [Meeting Abstract]
Grimm, J.; LaCouture, T.; Zhu, Y.; Xue, J.; Yeo, I.; Croce, R.; Hughes, S.
ISI:000411579600011
ISSN: 0094-2405
CID: 3542932
Dose Tolerance Limit Evaluation for Stereotactic Body Radiotherapy [Meeting Abstract]
Grimm, J; LaCouture, T; Zhu, Y; Xue, J; Yeo, I; Croce, R; Hughes, SL
ISI:000270573602438
ISSN: 0360-3016
CID: 2288432
Impact of transrectal ultrasound- and computed tomography-based seed localization on postimplant dosimetry in prostate brachytherapy
Chew, Meng-Sang; Xue, Jinyu; Houser, Chris; Misic, Vladimir; Cao, Junsheng; Cornwell, Thomas; Handler, Jay; Yu, Yan; Gressen, Eric
PURPOSE: To study the impact of seed localization, as performed by different observers using linked (125)I seeds, on postimplant dosimetry in prostate brachytherapy and, to compare transrectal ultrasound (TRUS)-based with CT-based approach for the dosimetric outcomes. METHODS AND MATERIALS: Nineteen permanent prostate implants were conducted using linked (125)I seeds. Postimplant TRUS and CT images were acquired and prostate glands were, after implantation, delineated on all images by a single oncologist, who had performed all 19 seeding procedures. Six observers independently localized the seeds on both TRUS and CT images, from which the principle dosimetric parameters V(100) (volume of prostate that received the prescribed dose), V(150) (volume of prostate that received 150% of the prescribed dose), and D(90) (minimal dose delivered to 90% of the prostate) were directly calculated for each patient. A single-factor analysis of variance was first applied to determine interobserver variability in seed localization. A nonparametric comparison of the approach using TRUS and CT was then carried out by the Wilcoxon paired-sample test. RESULTS: Analysis from the analysis of variance for TRUS showed that the null hypothesis for equal means, could not be rejected for all six observers based on a significance level alpha=0.05. TRUS-based and CT-based approaches were then cross compared by the Wilcoxon paired-sample test, which suggested that the null hypothesis was insignificant for V(100) and D(90), but was significant for V(150). CONCLUSIONS: Both TRUS- and CT-imaging modalities provided indistinguishable postimplant dosimetry results as far as V(100) and D(90) were concerned. There was comparable observer independence between TRUS- and CT-based seed localization for linked-seed implant procedures. With other advantages that TRUS-imaging modality had over CT in the evaluation of postimplant dosimetry, TRUS would be a preferred choice in conjunction with linked seeds for intraoperative procedures in prostate brachytherapy.
PMID: 19213606
ISSN: 1538-4721
CID: 2282102
Impact of Seed Localization On Post-Implant Dosimetry in Prostate Brachytherapy [Meeting Abstract]
Chew, M.; Xue, J.; Houser, C.; Misic, V.; Cao, J.; Cornwell, T.; Yu, Y.; Gressen, E.; Handler, J.
ISI:000411670200039
ISSN: 0094-2405
CID: 3542942
Linked fiducials for IGRT [Meeting Abstract]
Xue, J; Grimm, J; Zhu, Y
ISI:000258805302318
ISSN: 0360-3016
CID: 2288422
The effect of interobserver variability on transrectal ultrasonography-based postimplant dosimetry
Xue, Jinyu; Waterman, Frank; Handler, Jay; Gressen, Eric
PURPOSE: To investigate interobserver variability in contouring the prostate on postimplant transrectal ultrasonography (TRUS) images and its effect on dosimetric parameters that quantify implant quality. METHODS AND MATERIALS: Twenty preplanned peripherally loaded prostate implants were performed using 125I seeds and spacers linked together in linear arrays that maintain precise seed spacing and prevent seeds from rotating about their longitudinal axis. A set of two-dimensional transverse images spaced at 0.50-cm intervals was obtained with a high-resolution TRUS probe at the conclusion of the procedure with the patient still under anesthesia. A high percentage of the seeds (> 85%) were localized based on their visible echoes. The remaining seeds were identified based on the known locations of the "missing" seeds in the arrays. Two experienced ultrasonographers and a prostate brachytherapist independently contoured the prostate on the postimplant TRUS images. The prostate volumes defined by each observer were used to calculate the minimal dose received by 90% of the prostate volume (D90) and the percentage of the prostate volume receiving 100% of the prescribed minimal peripheral dose (V100). The observers also contoured the prostate on six preimplant TRUS studies to compare the variability in defining the prostate on pre- and postimplant TRUS images. RESULTS: The mean postimplant prostate volumes ranged from 20.8 to 66.9 cm3 (median: 45.7 cm3). The standard deviations (SDs), which reflect the variation in the volumes of the three observers, ranged from 1.4% to 26.1% of the mean (median: 11%). Multiple pairwise comparisons showed that the prostate volumes delineated by observer 3 differed significantly from those of observers 1 and 2 (p < 0.003). The volumes of observers 1 and 2 were not significantly different (p > 0.5). The mean values of D90 ranged from 124.2 to 171.1 Gy (median: 154.7 Gy) having SDs that ranged from 0.6% to 24.4% of the mean D90 (median: 7.8%). The mean values of V100 ranged from 82.3% to 95.1% (median: 92.8%) having SDs that ranged from 0.4% to 11.2% of the mean V100 (median: 4.0%). The values of both D90 and V100 calculated from the volumes of observer 3 were significantly (p < 0.003) different from those of observers 1 and 2, which did not differ significantly (p > 0.5). There was less interobserver variability in contouring the preimplant TRUS volumes. The mean volumes ranged from 20.3 to 54.3 cm3 having SDs that ranged from 1.9% to 14.1% (median: 8.6%). CONCLUSIONS: Significant interobserver differences in delineating the prostate volume on postimplant TRUS images were observed; however, these differences were less than generally reported for postimplant CT images. The interobserver differences in contouring the prostate in both TRUS and CT images produced significant differences in the dosimetric parameters, D90 and V100.
PMID: 16864069
ISSN: 1538-4721
CID: 2282112
Localization of linked 125I seeds in postimplant TRUS images for prostate brachytherapy dosimetry
Xue, Jinyu; Waterman, Frank; Handler, Jay; Gressen, Eric
PURPOSE: To demonstrate that (125)I seeds can be localized in transrectal ultrasound (TRUS) images obtained with a high-resolution probe when the implant is performed with linked seeds and spacers. Adequate seed localization is essential to the implementation of TRUS-based intraoperative dosimetry for prostate brachytherapy. METHODS AND MATERIALS: Thirteen preplanned peripherally loaded prostate implants were performed using (125)I seeds and spacers linked together in linear arrays that prevent seed migration and maintain precise seed spacing. A set of two-dimensional transverse images spaced at 0.50-cm intervals were obtained with a high-resolution TRUS probe at the conclusion of the procedure with the patient still under anesthesia. The image set extended from 1.0 cm superior to the base to 1.0 cm inferior to the apex. The visible echoes along each needle track were first localized and then compared with the known construction of the implanted array. The first step was to define the distal and proximal ends of each array. The visible echoes were then identified as seeds or spacers from the known sequence of the array. The locations of the seeds that did not produce a visible echo were interpolated from their known position in the array. A CT scan was obtained after implantation for comparison with the TRUS images. RESULTS: On average, 93% (range, 86-99%) of the seeds were visible in the TRUS images. However, it was possible to localize 100% of the seeds in each case, because the locations of the missing seeds could be determined from the known construction of the arrays. Two factors complicated the interpretation of the TRUS images. One was that the spacers also produced echoes. Although weak and diffuse, these echoes could be mistaken for seeds. The other was that the number of echoes along a needle track sometimes exceeded the number of seeds and spacers implanted. This was attributed to the overall length of the array, which was approximately 0.5 cm longer than the center-to-center distance between the first and last seed owing to the finite length of the seeds at the ends of the array. When this occurred, it was necessary to disregard either the most distal or most proximal echo, which produced a 0.5-cm uncertainty in the location of the array in the axial direction. For these reasons, simply localizing the visible echoes in the TRUS images did not guarantee the reliable identification of the seeds. CONCLUSION: Our results have demonstrated that a high percentage (>85%) of the implanted (125)I seeds can be directly visualized in postimplant TRUS images when the seeds and spacers are linked to preclude seed migration and rotation and when the images are obtained with a high-resolution TRUS probe. Moreover, it is possible to localize 100% of the seeds with the mechanism of linked seeds because the locations of the missing seeds can be determined from the known construction of the arrays.
PMID: 15936577
ISSN: 0360-3016
CID: 2282122
Feasibility of TRUS-based prostate post-implant dosimetry [Meeting Abstract]
Xue, J; Gressen, E
ISI:000222259100071
ISSN: 0094-2405
CID: 2292072
Plug pattern optimization for gamma knife radiosurgery treatment planning
Zhang, Pengpeng; Wu, Jackie; Dean, David; Xing, Lei; Xue, Jinyue; Maciunas, Robert; Sibata, Claudio
PURPOSE: To develop a novel dose optimization algorithm for improving the sparing of critical structures during gamma knife radiosurgery by shaping the plug pattern of each individual shot. METHOD AND MATERIALS: We first use a geometric information (medial axis) aided guided evolutionary simulated annealing (GESA) optimization algorithm to determine the number of shots and isocenter location, size, and weight of each shot. Then we create a plug quality score system that checks the dose contribution to the volume of interest by each plug in the treatment plan. A positive score implies that the corresponding source could be open to improve tumor coverage, whereas a negative score means the source could be blocked for the purpose of sparing normal and critical structures. The plug pattern is then optimized via the GESA algorithm that is integrated with this score system. Weight and position of each shot are also tuned in this procedure. RESULTS: An acoustic tumor case is used to evaluate our algorithm. Compared to the treatment plan generated without plug patterns, adding an optimized plug pattern into the treatment planning process boosts tumor coverage index from 95.1% to 97.2%, reduces RTOG conformity index from 1.279 to 1.167, lowers Paddick's index from 1.34 to 1.20, and trims the critical structure receiving more than 30% maximum dose from 16 mm(3) to 6 mm(3). CONCLUSIONS: Automated GESA-based plug pattern optimization of gamma knife radiosurgery frees the treatment planning team from the manual forward planning procedure and provides an optimal treatment plan.
PMID: 12527055
ISSN: 0360-3016
CID: 2289092
Measurement of scintillation light attenuation in liquid scintillation solutions for 3D dosimetry [Meeting Abstract]
Kirov, A; Piao, Z; Winkler, M; Xue, J; Devic, S; Binns, W; Kusner, M; Hurlbut, C; Kinsella, T; Sibata, C
ISI:000176373400088
ISSN: 0094-2405
CID: 2292042