Changes in prostate volume during prostate SBRT delivered on an MR-Linac and correlation with acute toxicity
Gurewitz, Jason; Oh, Cheongeun; Woo, Sungmin; Kim, Jiyu; Bruzzese, Adam; Chen, Ting; Wang, Hesheng; Byun, David; Zelefsky, Michael J
PURPOSE/UNASSIGNED:We evaluated prostate volume changes during stereotactic body radiation therapy (SBRT) using serial MRI, identifying variables associated with prostatic swelling and their correlation with acute toxicity. METHODS/UNASSIGNED:Fifty-two patients with localized prostate cancer, androgen deprivation therapy naive, underwent SBRT to 40 Gy in five fractions on an MRI-Linear Accelerator with dominant intraprostatic lesion boosts to 45 Gy when present. Whole prostate (WP) and transition zone (TZ) measurements were assessed on the pre-treatment T2 MRI obtained for daily adaptation. Volumes were calculated using the ellipsoid formula. Non-transition zone (nonTZ) measures = WP values - TZ values. Transition zone index (TZI) = TZ volume/WP volume. Acute toxicity and International Prostate Symptom Scores (IPSS) were recorded. RESULTS/UNASSIGNED:Prostate volume increased significantly over the first four fractions, peaking at fraction 4 with mean percent and absolute changes of 21 % and 7.8 cc, respectively. Standardized TZ measures were strongly associated with WP volume (β per SD 10.60-12.78; all p < 0.001), whereas the only nonTZ dimension weakly associated was anteroposterior (β per SD 1.78). Each standard deviation increase in baseline TZ parameters doubled to tripled the odds of significant swelling (≥10 cc) (all p ≤ 0.011). The interaction of baseline TZI with later fractions was significantly associated with swelling (fraction 4: β = 12.06, p = 0.020; fraction 5: β = 10.96, p = 0.036), but not baseline TZI alone. Neither Grade 2+ genitourinary toxicity nor IPSS changes were associated with prostate measures or TZI. CONCLUSIONS/UNASSIGNED:Prostate volume significantly increases during SBRT, primarily corresponding with TZ volumetric changes. Baseline TZ measurements most strongly predict high-volume swelling. Acute toxicity was not associated with volumetric change.
PMCID:12269632
PMID: 40677622
ISSN: 2405-6308
CID: 5897512
Bladder filling dynamics during online adaptive prostate stereotactic body radiotherapy: Rationale for using an empty bladder workflow for treatment
Byun, David J; Oh, Cheongeun; Kim, Jiyu; Barbee, David; Long, Matthew; Fuligni, Gabriel; Chen, Ting; Wang, Hesheng; Lu, Siming; Zelefsky, Michael J
PURPOSE/OBJECTIVE:To evaluate the degree and rate of bladder filling during magnetic resonance imaging-guided linear accelerator (MRL) prostate stereotactic body radiotherapy (SBRT), and to determine the association of degree of bladder filling with intra-fractional prostatic motion requiring positional shifts during therapy. The impact of bladder filling on post-treatment target and normal tissue dosimetry was also evaluated. METHODS:Sixty-two consecutive prostate SBRT patients treated on the MRL with an empty bladder and a five-fraction regimen were evaluated. Bladder filling patterns during each treatment session and the frequency of required shifts to address intra-fractional prostate motion were studied. During each fraction, three MR image acquisitions were obtained: an immediate baseline T2-weighted sequence, a verification sequence after the plan was generated prior to treatment delivery, and a sequence post-treatment. Bladder filling rates were evaluated at these time points for each fraction and across the five treatment fractions. Multivariate analysis identified variables associated with increased bladder filling rates and the likelihood of positional target adjustments of the prostate during real-time adaptive planning. Post-treatment MR structures were used to recalculate plans for analysis of intra-fractional dosimetric variations in target and normal tissue doses. RESULTS:The median baseline bladder volume at fraction 1 was 88 cc (range 35-245), increasing to 138 cc (range 55-340) at verification MR and 156 cc (range 69-475) post-treatment. Bladder volume increases from baseline to verification MR and from verification MR to post-treatment MR were consistent across the cohort. Multivariate analysis identified the use of alpha receptor blockers during treatment (beta - 17.36 mL; 95 % CI - 32.97, -1.74; p = 0.030) and lower baseline bladder volume (beta 11.62 mL; 95 % CI 4.20, 19.05; p = 0.002) as significant factors in limiting both absolute bladder volume and the rate of bladder filling during adaptive SBRT fractions. Conversely, the need for a positional target shift at verification MR was associated with larger bladder volume (OR 1.20; 95 % CI 0.98, 1.46; p = 0.075) and high International Prostate Symptom Score (OR 5.42; 95 % CI 1.34, 21.89; p = 0.018). Post-treatment dosimetric analysis revealed no notable compromises to prostate target coverage (D95Gy median -0.19 Gy, IQR 0.49) or normal tissue constraints. CONCLUSIONS:This analysis of bladder filling dynamics in patients undergoing prostate SBRT with real-time adaptive planning demonstrated predictable bladder filling patterns using an empty bladder regimen. Dose-volume constraints were consistently achieved for both target volumes and normal tissues. The finding that alpha receptor blockers reduced the rate of bladder filling during treatment fractions may have implications for improving treatment consistency and patient comfort in real-time adaptive planning workflows.
PMID: 40466739
ISSN: 1879-0887
CID: 5862462
Commissioning and implementation of a pencil-beam algorithm with a Lorentz correction as a secondary dose calculation algorithm for an Elekta Unity 1.5T MR linear accelerator
Taneja, Sameer; Wang, Hesheng; Barbee, David L; Galavis, Paulina; Sosa, Mario Serrano; Byun, David; Zelefsky, Michael; Chen, Ting
PURPOSE/OBJECTIVE:To commission a beam model in ClearCalc (Radformation Inc.) for use as a secondary dose calculation algorithm and to implement its use into an adaptive workflow for an MR-linear accelerator. METHODS:A beam model was developed using commissioning data for an Elekta Unity MR-linear accelerator and entered into ClearCalc. The beam model consisted of absolute dose calculation settings, output factors, percent depth-dose (PDD) curves, mutli-leaf collimator (MLC) transmission and dose leaf gap error, and cryostat corrections. Beam profiles were hard-coded by the manufacturer into the beam model and were compared with Monaco-derived profiles. The beam model was tested by comparing point doses in a homogenous phantom obtained through measurements using an ionization chamber in water, Monaco, and ClearCalc for various field sizes, source-surface distances (SSDs), and point locations. Additional testing including point dose verification for test plans using a heterogeneous phantom and patient plans. Post clinical implementation, performance of ClearCalc was evaluated for the first 41 patients treated, which included 215 adaptive plans. RESULTS:PDDs generated using ClearCalc fell within 1.2% of measurements. Field profile comparison between ClearCalc and Monaco showed an average pass rate of 98% using a 3%/3 mm gamma criteria. Measured cryostat corrections used in the beam model showed a maximum deviation from unity of 1.4%. Point dose and field monitor units (MUs) comparisons in a homogenous phantom (N = 22), heterogeneous phantoms (N = 22), and patient plans (N = 57) all passed with a threshold of 5%/5MU. Clinically, ClearCalc was implemented as a physics check post adaptive planning completed prior to beam delivery. Point dose and field MUs showed good agreement at a 5%/5MU threshold for prostate stereotactic body radiation therapy (SBRT), pelvic lymph nodes, rectum, and prostate and lymph node plans. DISCUSSION/CONCLUSIONS:This work demonstrated commissioning and clinical implementation of ClearCalc into an adaptive planning workflow. No primary or adaptive plan failures were reported with proper beam model testing.
PMID: 39625056
ISSN: 1526-9914
CID: 5804362
Deconvolution of the tumor-educated platelet transcriptome reveals activated platelet and inflammatory cell transcript signatures
Karp, Jerome M; Modrek, Aram S; Ezhilarasan, Ravesanker; Zhang, Ze-Yan; Ding, Yingwen; Graciani, Melanie; Sahimi, Ali; Silvestro, Michele; Chen, Ting; Li, Shuai; Wong, Kwok-Kin; Ramkhelawon, Bhama; Bhat, Krishna Pl; Sulman, Erik P
Tumor-educated platelets (TEPs) are a potential method of liquid biopsy for the diagnosis and monitoring of cancer. However, the mechanism underlying tumor education of platelets is not known, and transcripts associated with TEPs are often not tumor-associated transcripts. We demonstrated that direct tumor transfer of transcripts to circulating platelets is an unlikely source of the TEP signal. We used CDSeq, a latent Dirichlet allocation algorithm, to deconvolute the TEP signal in blood samples from patients with glioblastoma. We demonstrated that a substantial proportion of transcripts in the platelet transcriptome are derived from nonplatelet cells, and the use of this algorithm allows the removal of contaminant transcripts. Furthermore, we used the results of this algorithm to demonstrate that TEPs represent a subset of more activated platelets, which also contain transcripts normally associated with nonplatelet inflammatory cells, suggesting that these inflammatory cells, possibly in the tumor microenvironment, transfer transcripts to platelets that are then found in circulation. Our analysis suggests a useful and efficient method of processing TEP transcriptomic data to enable the isolation of a unique TEP signal associated with specific tumors.
PMCID:11466191
PMID: 39190500
ISSN: 2379-3708
CID: 5705692
A Tool to Integrate Electrophysiological Mapping for Cardiac Radioablation of Ventricular Tachycardia
Wang, Hesheng; Barbhaiya, Chirag R; Yuan, Ye; Barbee, David; Chen, Ting; Axel, Leon; Chinitz, Larry A; Evans, Andrew J; Byun, David J
PURPOSE/UNASSIGNED:Cardiac radioablation is an emerging therapy for recurrent ventricular tachycardia. Electrophysiology (EP) data, including electroanatomic maps (EAM) and electrocardiographic imaging (ECGI), provide crucial information for defining the arrhythmogenic target volume. The absence of standardized workflows and software tools to integrate the EP maps into a radiation planning system limits their use. This study developed a comprehensive software tool to enable efficient utilization of the mapping for cardiac radioablation treatment planning. METHODS AND MATERIALS/UNASSIGNED:After the scar area is outlined on the mapping surface, the tool extracts and extends the annotated patch into a closed surface and converts it into a structure set associated with the anatomic images. The tool then exports the structure set and the images as The Digital Imaging and Communications in Medicine Standard in Radiotherapy for a radiation treatment planning system to import. Overlapping the scar structure on simulation CT, a transmural target volume is delineated for treatment planning. RESULTS/UNASSIGNED:The tool has been used to transfer Ensite NavX EAM data into the Varian Eclipse treatment planning system in radioablation on 2 patients with ventricular tachycardia. The ECGI data from CardioInsight was retrospectively evaluated using the tool to derive the target volume for a patient with left ventricular assist device, showing volumetric matching with the clinically used target with a Dice coefficient of 0.71. CONCLUSIONS/UNASSIGNED:HeaRTmap smoothly fuses EP information from different mapping systems with simulation CT for accurate definition of radiation target volume. The efficient integration of EP data into treatment planning potentially facilitates the study and adoption of the technique.
PMCID:10320498
PMID: 37415904
ISSN: 2452-1094
CID: 5539402
Advances in verification and delivery techniques
Chapter by: Chen, Ting; Wang, Hesheng
in: Principles and Practice of Image-Guided Abdominal Radiation Therapy by
[S.l.] : Institute of Physics Publishing, 2022
pp. 17-?
ISBN: 9780750324663
CID: 5550522
Predicting local failure of brain metastases after stereotactic radiosurgery with radiomics on planning MR images and dose maps
Wang, Hesheng; Xue, Jinyu; Qu, Tanxia; Bernstein, Kenneth; Chen, Ting; Barbee, David; Silverman, Joshua S; Kondziolka, Douglas
PURPOSE/OBJECTIVE:Stereotactic radiosurgery (SRS) has become an important modality in the treatment of brain metastases. The purpose of this study is to investigate the potential of radiomic features from planning magnetic resonance (MR) images and dose maps to predict local failure after SRS for brain metastases. MATERIALS/METHODS/METHODS:Twenty-eight patients who received Gamma Knife (GK) radiosurgery for brain metastases were retrospectively reviewed in this IRB-approved study. 179 irradiated tumors included 42 that locally failed within one-year follow-up. Using SRS tumor volumes, radiomic features were calculated on T1-weighted contrast-enhanced MR images acquired for treatment planning and planned dose maps. 125 radiomic features regarding tumor shape, dose distribution, MR intensities and textures were extracted for each tumor. Logistic regression with automatic feature selection was built to predict tumor progression from local control after SRS. Feature selection and model evaluation using receiver operating characteristic (ROC) curves were performed in a nested cross validation (CV) scheme. The associations between selected radiomic features and treatment outcomes were statistically assessed by univariate analysis. RESULTS:The logistic model with feature selection achieved ROC AUC of 0.82 ± 0.09 on 5-fold CV, providing 83% sensitivity and 70% specificity for predicting local failure. A total of 10 radiomic features including 1 shape feature, 6 MR images and 3 dose distribution features were selected. These features were significantly associated with treatment outcomes (p < 0.05). The model was validated on independent holdout data with an AUC of 0.78. CONCLUSIONS:Radiomic features from planning MR images and dose maps provided prognostic information in SRS for brain metastases. A model built on the radiomic features shows promise for early prediction of tumor local failure after treatment, potentially aiding in personalized care for brain metastases.
PMID: 34287940
ISSN: 2473-4209
CID: 5003892
Automatic couch position calculation using eclipse scripting for external beam radiotherapy
Wang, Hesheng; Rea, Anthony; Rudek, Benedikt; Chen, Ting; McCarthy, Allison; Barbee, David
PURPOSE/OBJECTIVE:The treatment couch position of a patient in external beam radiation therapy (EBRT) is usually acquired during initial treatment setup. This procedure has shown potential failure modes leading to near misses and adverse events in radiation treatment. This study aims to develop a method to automatically determine the couch position before setting up a patient for initial treatment. METHODS:The Qfix couch-tops (kVue and DoseMax) have embedded reference marks (BBs) indicating its index levels and couch centerline. With the ESAPI, a C# script was programmed to automatically find the couch-top and embedded BBs in the planning CT and derive the treatment couch position according to treatment isocenter of a plan. Couch positions of EBRT plans with the kVue couch-top and SBRT plans using the DoseMax were calculated using the script. The calculation was evaluated by comparing calculated positions with couch coordinates captured during the initial treatment setup after image guidance. The calculations were further compared with daily treatment couch positions post image-guided adjustment for each treatment fraction. RESULTS:For plans using the kVue couch-top for various treatment sites, the median (5-95 percentiles) differences between calculated and captured couch positions were 0.1 (-0.2 - 0.9), 0.5 (-1.1-2.0), 0.10 (-1.3-1.3) cm in the vertical, longitudinal, and lateral direction respectively. For the DoseMax couch-top, the median differences were 0.1 (-0.2-0.7), 0.2 (-0.3-1.1), and 0.2 (-0.7-0.9) cm in respective direction. The calculated positions were within 1 and 2Â cm from the mean fraction positions for 95% patients on DoseMax and kVue couch-top respectively. CONCLUSIONS:A method that automatically and accurately calculates treatment couch position from simulation CT was implemented in Varian Eclipse for Qfix couch-tops. This technique increases the efficiency of patient setup and enhances patient safety by reducing the risks of positioning errors.
PMID: 33440075
ISSN: 1526-9914
CID: 4764912
Data-Driven Generation of CBCT-To-CT HU Mapping for Adaptive Radiotherapy in H&N Cancer [Meeting Abstract]
Wang, H.; Rea, A.; Xue, J.; Spuhler, K.; Qu, T.; Chen, T.; Barbee, D.; Hu, K.
ISI:000673145403232
ISSN: 0094-2405
CID: 5320842
Adaptive radiotherapy based on statistical process control for oropharyngeal cancer
Wang, Hesheng; Xue, Jinyu; Chen, Ting; Qu, Tanxia; Barbee, David; Tam, Moses; Hu, Kenneth
PURPOSE/OBJECTIVE:The purpose of this study is to quantify dosimetric changes throughout the delivery of oropharyngeal cancer treatment and to investigate the application of statistical process control (SPC) for the management of significant deviations during the course of radiotherapy. METHODS:Thirteen oropharyngeal cancer patients with daily cone beam computed tomography (CBCT) were retrospectively reviewed. Cone beam computed tomography images of every other fraction were imported to the Velocity software and registered to planning CT using the 6 DOF (degrees of freedom) couch shifts generated during patient setup. Using Velocity "Adaptive Monitoring" module, the setup-corrected CBCT was matched to planning CT using a deformable registration. Volumes and dose metrics at each fraction were calculated and rated with plan values to evaluate interfractional dosimetric variations using a SPC framework. T-tests between plan and fraction volumes were performed to find statistically insignificant fractions. Average upper and lower process capacity limits (UCL, LCL) of each dose metric were derived from these fractions using conventional SPC guidelines. RESULTS:Gross tumor volume (GTV) and organ at risk (OAR) volumes in the first 13 fractions had no significant changes from the pretreatment planning CT. The GTV and the parotid glands subsequently decreased by 10% at the completion of treatment. There were 3-4% increases in parotid mean doses, but no significant differences in dose metrics of GTV and other OARs. The changes were organ and patient dependent. Control charts for various dose metrics were generated to assess the metrics at each fraction for individual patient. CONCLUSIONS:Daily CBCT could be used to monitor dosimetric variations of targets and OARs resulting from volume changes and tissue deformation in oropharyngeal cancer radiotherapy. Treatment review with the guidance of a SPC tool allows for an objective and consistent clinical decision to apply adaptive radiotherapy.
PMID: 32770651
ISSN: 1526-9914
CID: 4560192