Try a new search

Format these results:

Searched for:

person:balcel01

Total Results:

431


Evolution of Visual Outcomes in Clinical Trials for Multiple Sclerosis Disease-Modifying Therapies

Nolan, Rachel C; Akhand, Omar; Rizzo, John-Ross; Galetta, Steven L; Balcer, Laura J
: BACKGROUND:: The visual pathways are increasingly recognized as an ideal model to study neurodegeneration in multiple sclerosis (MS). Low-contrast letter acuity (LCLA) and optical coherence tomography (OCT) are validated measures of function and structure in MS. In fact, LCLA was the topic of a recent review by the Multiple Sclerosis Outcome Assessments Consortium (MSOAC) to qualify this visual measure as a primary or secondary clinical trial endpoint with the Food and Drug Administration (FDA) and other regulatory agencies. This review focuses on the use of LCLA and OCT measures as outcomes in clinical trials to date of MS disease-modifying therapies.
PMCID:6026328
PMID: 29750734
ISSN: 1536-5166
CID: 3101672

Identification and treatment of the visual processing asymmetry in MS patients with optic neuritis: The Pulfrich phenomenon

Sobhanian, Millad J; Agarwal, Rohit; Meltzer, Ethan; Kildebeck, Eric; Frohman, Benjamin S; Frohman, Ashley N; Galetta, Steven L; Saidha, Shiv; White, Owen; Villoslada, Pablo; Paul, Friedemann; Petzold, Axel; Rennaker, Robert L; Martinez-Lapiscina, Elena H; Balcer, Laura J; Kardon, Randy; Frohman, Elliot M; Frohman, Teresa C
BACKGROUND:The Pulfrich phenomenon (PF) is the illusory perception that an object moving linearly along a 2-D plane appears to instead follow an elliptical 3-D trajectory, a consequence of inter-eye asymmetry in the timing of visual object identification in the visual cortex; with optic neuritis as a common etiology. OBJECTIVE:We have designed an objective method to identify the presence and magnitude of the PF, in conjunction with a cooresponding strategy by which to abolish the effect; with monocular application of neutral density filters to the less affected fellow eye, in patients with MS and a history of optic neuropathy (e.g. related to acute optic neuritis or subclinical optic neuropathy). METHODS:Twenty-three MS patients with a history of acute unilateral or bilateral optic neuritis, and ten healthy control subjects (HC) were recruited to participate in a pilot study to assess our strategy. Subjects were asked to indicate whether a linearly moving pendulum ball followed a linear 2-D path versus an illusory 3-D elliptical object-motion trajectory, by reporting the ball's approximation to one of nine horizontally-oriented colored wires that were positioned parallel to one another and horizontal to the linear pendulum path. Perceived motion of the bob that moved along wires behind or in front (along the 'Z' plane) of the middle reference wire indicated an illusory elliptical trajectory of ball motion consistent with the PF. RESULTS:When the neutral density filter titration was applied to the fellow eye the severity of the PF decreased, eventually being fully abolished in all but one patient. The magnitude of neutral density filtering required correlated to the severity of the patient's initial PF magnitude (p < 0.001). CONCLUSIONS:We ascertained the magnitude of the visual illusion associated with the PF, and the corresponding magnitude of neutral density filtering necessary to abolish it.
PMID: 29571874
ISSN: 1878-5883
CID: 3001642

The new Mobile Universal Lexicon Evaluation System (MULES): A test of rapid picture naming for concussion sized for the sidelines

Akhand, Omar; Galetta, Matthew S; Cobbs, Lucy; Hasanaj, Lisena; Webb, Nikki; Drattell, Julia; Amorapanth, Prin; Rizzo, John-Ross; Nolan, Rachel; Serrano, Liliana; Rucker, Janet C; Cardone, Dennis; Jordan, Barry D; Silverio, Arlene; Galetta, Steven L; Balcer, Laura J
OBJECTIVE:Measures of rapid automatized naming (RAN) have been used for over 50 years to capture vision-based aspects of cognition. The Mobile Universal Lexicon Evaluation System (MULES) is a test of rapid picture naming under investigation for detection of concussion and other neurological disorders. MULES was designed as a series of 54 grouped color photographs (fruits, random objects, animals) that integrates saccades, color perception and contextual object identification. Recent changes to the MULES test have been made to improve ease of use on the athletic sidelines. Originally an 11 × 17-inch single-sided paper, the test has been reduced to a laminated 8.5 × 11-inch double-sided version. We identified performance changes associated with transition to the new, MULES, now sized for the sidelines, and examined MULES on the sideline for sports-related concussion. METHODS:We administered the new laminated MULES to a group of adult office volunteers as well as youth and collegiate athletes during pre-season baseline testing. Athletes with concussion underwent sideline testing after injury. Time scores for the new laminated MULES were compared to those for the larger version (big MULES). RESULTS:Among 501 athletes and office volunteers (age 16 ± 7 years, range 6-59, 29% female), average test times at baseline were 44.4 ± 14.4 s for the new laminated MULES (n = 196) and 46.5 ± 16.3 s for big MULES (n = 248). Both versions were completed by 57 participants, with excellent agreement (p < 0.001, linear regression, accounting for age). Age was a predictor of test times for both MULES versions, with longer times noted for younger participants (p < 0.001). Among 6 athletes with concussion thus far during the fall sports season (median age 15 years, range 11-21) all showed worsening of MULES scores from pre-season baseline (median 4.0 s, range 2.1-16.4). CONCLUSION/CONCLUSIONS:The MULES test has been converted to an 11 × 8.5-inch laminated version, with excellent agreement between versions across age groups. Feasibly administered at pre-season and in an office setting, the MULES test shows preliminary evidence of capacity to identify athletes with sports-related concussion.
PMCID:6022286
PMID: 29571863
ISSN: 1878-5883
CID: 3001632

Relation of Quantitative Eye Movements with Cognitive Dysfunction in Patients with Concussion [Meeting Abstract]

Gold, Doria; Martone, John; Lee, Yuen Shan Christine; Childs, Amanda; Matsuzawa, Yuka; Fraser, Felicia; Ricker, Joseph; Dai, Wei-Wei; Rizzo, John-Ross; Hudson, Todd; Selesnick, Ivan; Galetta, Steven; Balcer, Laura; Rucker, Janet
ISI:000453090805233
ISSN: 0028-3878
CID: 3561672

Mobile Universal Lexicon Evaluation System (MULES) in MS: Evaluation of a New Visual Test of Rapid Picture Naming [Meeting Abstract]

Seay, Meagan; Akhand, Omar; Cobbs, Lucy; Hasanaj, Lisena; Amorapanth, Prin; Rizzo, John-Ross; Nolan, Rachel; Serrano, Liliana; Jordan, Barry; Rucker, Janet; Galetta, Steven; Balcer, Laura
ISI:000453090805232
ISSN: 0028-3878
CID: 3561682

Optimal Inter-Eye Difference Thresholds in Retinal Nerve Fiber Layer and Ganglion Cell Layer Thickness for Predicting a Unilateral Optic Nerve Lesion in Multiple Sclerosis: An International Collaborative Study [Meeting Abstract]

Nolan, Rachel; Akhand, Omar; Calabresi, Peter; Paul, Friedemann; Hernandez Martinez de Lapiscina, Elena; Petzold, Axel; Brandt, Alexander; Saidha, Shiv; Villoslada, Pablo; Abu-Hassan, Abdullah; Behbehani, Raed; Frohman, Elliot; Frohman, Teresa; Havla, Joachim; Hemmer, Bernhard; Jiang, Hong; Knier, Benjamin; Korn, Thomas; Leocani, Letizia; Papadopoulou, Athina; Pisa, Marco; Zimmermann, Hanna; Galetta, Steven; Balcer, Laura
ISI:000453090801150
ISSN: 0028-3878
CID: 3562012

'Sandbagging' a Vision Test for Concussion-based Sideline Assessment: An Eye Movement Investigation Objectively Reveals the 'Gamers' Strategies [Meeting Abstract]

Rucker, Janet; Hasanaj, Lisena; Rizzo, John-Ross; Hudson, Todd; Dai, Weiwei; Martone, John; Chaudhry, Yash; Ihionu, Oluchi; Selesnick, Ivan; Balcer, Laura; Galetta, Steven
ISI:000453090801144
ISSN: 0028-3878
CID: 3561472

Assessing and Enhancing Neurology Resident Education on Interpersonal Communication and Professionalism [Meeting Abstract]

Kurzweil, Arielle; Lewis, Ariane; Pleninger, Perrin; Rostanski, Sara; Nelson, Aaron; Ishida, Koto; Balcer, Laura; Galetta, Steven
ISI:000453090801443
ISSN: 0028-3878
CID: 3561972

The New MULES: A Sideline-Friendly Test of Rapid Picture Naming for Concussion [Meeting Abstract]

Akhand, Omar; Galetta, Matthew; Hasanaj, Lisena; Cobbs, Lucy; Webb, Nikki; Brandt, Julia; Amorapanth, Prin; Rizzo, John-Ross; Serrano, Liliana; Nolan, Rachel; Rucker, Janet; Silverio, Arlene; Jordan, Barry; Galetta, Steven; Balcer, Laura
ISI:000453090801159
ISSN: 0028-3878
CID: 3562002

Analysis of Agreement of Retinal-Layer Thickness Measures Derived from the Segmentation of Horizontal and Vertical Spectralis OCT Macular Scans

Gonzalez Caldito, Natalia; Antony, Bhavna; He, Yufan; Lang, Andrew; Nguyen, James; Rothman, Alissa; Ogbuokiri, Esther; Avornu, Ama; Balcer, Laura; Frohman, Elliot; Frohman, Teresa C; Bhargava, Pavan; Prince, Jerry; Calabresi, Peter A; Saidha, Shiv
PURPOSE/OBJECTIVE:Optical coherence tomography (OCT) is a reliable method used to quantify discrete layers of the retina. Spectralis OCT is a device used for this purpose. Spectralis OCT macular scan imaging acquisition can be obtained on either the horizontal or vertical plane. The vertical protocol has been proposed as favorable, due to postulated reduction in confound of Henle's fibers on segmentation-derived metrics. Yet, agreement of the segmentation measures of horizontal and vertical macular scans remains unexplored. Our aim was to determine this agreement. MATERIALS AND METHODS/METHODS:Horizontal and vertical macular scans on Spectralis OCT were acquired in 20 healthy controls (HCs) and 20 multiple sclerosis (MS) patients. All scans were segmented using Heidelberg software and a Johns Hopkins University (JHU)-developed method. Agreement was analyzed using Bland-Altman analyses and intra-class correlation coefficients (ICCs). RESULTS:Using both segmentation techniques, mean differences (agreement at the cohort level) in the thicknesses of all macular layers derived from both acquisition protocols in MS patients and HCs were narrow (<1 µm), while the limits of agreement (LOA) (agreement at the individual level) were wider. Using JHU segmentation mean differences (and LOA) for the macular retinal nerve fiber layer (RNFL) and ganglion cell layer + inner plexiform layer (GCIP) in MS were 0.21 µm (-1.57-1.99 µm) and -0.36 µm (-1.44-1.37 µm), respectively. CONCLUSIONS:OCT segmentation measures of discrete retinal-layer thicknesses derived from both vertical and horizontal protocols on Spectralis OCT agree excellently at the cohort level (narrow mean differences), but only moderately at the individual level (wide LOA). This suggests patients scanned using either protocol should continue to be scanned with the same protocol. However, due to excellent agreement at the cohort level, measures derived from both acquisitions can be pooled for outcome purposes in clinical trials.
PMCID:6097232
PMID: 29240464
ISSN: 1460-2202
CID: 2844002