Searched for: person:grosse01
Intraoperative outcomes of the Coapsys (TM) annuloplasty system in a randomized evaluation (RESTOR-MV) of functional ischemic mitral regurgitation [Meeting Abstract]
Grossi, EA; Woo, YJ; Gangahar, DM; Laschinger, JC; Kress, DC; Caskey, MP
ISI:000224783502306
ISSN: 0009-7322
CID: 55944
Vein graft arterialization causes differential activation of mitogen-activated protein kinases
Saunders, Paul C; Pintucci, Giuseppe; Bizekis, Costas S; Sharony, Ram; Hyman, Kevin M; Saponara, Fiorella; Baumann, F Gregory; Grossi, Eugene A; Colvin, Stephen B; Mignatti, Paolo; Galloway, Aubrey C
OBJECTIVE: Vascular injury results in activation of the mitogen-activated protein kinases-extracellular-signal regulated kinases, c-jun N-terminal kinase, and p38(MAPK)-which have been implicated in cell proliferation, migration, and apoptosis. The goal of this study was to characterize mitogen-activated protein kinase activation in arterialized vein grafts. METHODS: Carotid artery bypass using reversed external jugular vein was performed in 29 dogs. Vein grafts were harvested after 30 minutes and 3, 8, and 24 hours, and 4, 7, 14, and 28 days. Contralateral external jugular vein and external jugular vein interposition vein-to-vein grafts were used as controls. Vein graft extracts were analyzed for extracellular-signal regulated kinases, c-jun N-terminal kinase, and p38(MAPK) activation. Proliferating cell nuclear antigen expression was investigated as a parameter of cell proliferation. Apoptosis was assessed by terminal deoxynucleotidyl transferase-mediated 2'-deoxyuridine 5'-triphosphate nick end labeling staining and intimal hyperplasia by morphometric examination of tissue sections. RESULTS: Significant intimal hyperplasia was observed at 28 days. Over the time points studied, vein graft arterialization resulted in bimodal activation of both extracellular-signal regulated kinase and p38(MAPK) (30 minutes through 3 hours; 4 days) but did not induce activation of c-jun N-terminal kinase. Proliferating cell nuclear antigen expression increased from days 1 through 28, and apoptosis increased between 8 and 24 hours. CONCLUSION: Vein graft arterialization induces bimodal activation of extracellular-signal regulated kinase and p38(MAPK); however, in contrast with what is described in arterial injury, it does not induce c-jun N-terminal kinase activation. These results provide the first comprehensive characterization of the mitogen-activated protein kinase signaling pathways activated in vein graft arterialization and identify mitogen-activated protein kinases as potential mediators of vein graft remodeling and subsequent intimal hyperplasia
PMID: 15115983
ISSN: 0022-5223
CID: 45314
Minimally invasive technology for mitral valve surgery via left thoracotomy: experience with forty cases
Saunders, Paul C; Grossi, Eugene A; Sharony, Ram; Schwartz, Charles F; Ribakove, Greg H; Culliford, Alfred T; Delianides, Julie; Baumann, F Gregory; Galloway, Aubrey C; Colvin, Stephen B
BACKGROUND: Recent evolution of minimally invasive technology has expanded the application of the right thoracotomy approach for mitral valve surgery. These same technological advances have also made the left posterior minithoracotomy approach attractive in complex mitral procedures. METHODS: From 1996 to 2003, 921 isolated mitral valve procedures were performed without sternotomy; 40 (4.3%) of these were performed via left posterior minithoracotomy. In the left posterior minithoracotomy group, ages ranged from 18 to 84 years; 36 patients had had previous cardiac surgery (9 on > or =2 occasions). Other factors precluding right thoracotomy included mastectomy/radiation and pectus excavatum. RESULTS: Arterial perfusion was via femoral artery (n = 26) or descending aorta (n = 14); long femoral venous cannulas with vacuum-assisted drainage were used in 39 procedures. Two patients had direct aortic crossclamping, 18 had hypothermic fibrillation, and 20 had balloon endoaortic occlusion. The mean crossclamp and bypass times were 81.9 and 117.2 minutes, respectively. Hospital mortality was 5.0% (2/40); both deaths occurred in octogenarians. There were no injuries to bypass grafts or conversions to sternotomy. Complications included perioperative stroke (2/40; 5.0%), bleeding (2/40; 5.0%), and respiratory failure (1/40; 2.5%); 28 patients (70%) had no postoperative complications. There was no incidence of perioperative myocardial infarction, renal failure, sepsis, or wound infection. The median length of stay was 7 days. CONCLUSIONS: Advances in minimally invasive cardiac surgery technology are readily adaptable to a left-sided minithoracotomy approach to the mitral valve. The left posterior minithoracotomy approach is a valuable option in complicated reoperative mitral procedures with acceptable perioperative morbidity and mortality
PMID: 15052199
ISSN: 0022-5223
CID: 45686
Revascularization alone for functional mitral regurgitation: A propensity case-match analysis of the off pump coronary artery bypass approach [Meeting Abstract]
Saunders, PC; Grossi, EA; Schwartz, CF; Applebaum, RM; Ribakove, GH; Culliford, AT; Galloway, AC; Colvin, SB
ISI:000189388501166
ISSN: 0735-1097
CID: 42552
Computer-generated three-dimensional animation of the mitral valve
Dayan, Joseph H; Oliker, Aaron; Sharony, Ram; Baumann, F Gregory; Galloway, Aubrey; Colvin, Stephen B; Miller, D Craig; Grossi, Eugene A
OBJECTIVE: Three-dimensional motion-capture data offer insight into the mechanical differences of mitral valve function in pathologic states. Although this technique is precise, the resulting time-varying data sets can be both difficult to interpret and visualize. We used a new technique to transform these 3-dimensional ovine numeric analyses into an animated human model of the mitral apparatus that can be deformed into various pathologic states. METHODS: In vivo, high-speed, biplane cinefluoroscopic images of tagged ovine mitral apparatus were previously analyzed under normal and pathologic conditions. These studies produced serial 3-dimensional coordinates. By using commercial animation and custom software, animated 3-dimensional models were constructed of the mitral annulus, leaflets, and subvalvular apparatus. The motion data were overlaid onto a detailed model of the human heart, resulting in a dynamic reconstruction. RESULTS: Numeric motion-capture data were successfully converted into animated 3-dimensional models of the mitral valve. Structures of interest can be isolated by eliminating adjacent anatomy. The normal and pathophysiologic dynamics of the mitral valve complex can be viewed from any perspective. CONCLUSION: This technique provides easy and understandable visualization of the complex and time-varying motion of the mitral apparatus. This technology creates a valuable research and teaching tool for the conceptualization of mitral valve dysfunction and the principles of repair
PMID: 15001905
ISSN: 0022-5223
CID: 42581
When should we attempt to make a silk purse from a sow's ear? [Editorial]
Grossi, Eugene A
PMID: 15001883
ISSN: 0022-5223
CID: 96504
Semirigid partial annuloplasty band allows dynamic mitral annular motion and minimizes valvular gradients: an echocardiographic study
Sharony, Ram; Saunders, Paul C; Nayar, Ambika; McAleer, Eileen; Galloway, Aubrey C; Delianides, Julie; Schwartz, Charles F; Applebaum, Robert M; Kronzon, Itzhak; Colvin, Stephen B; Grossi, Eugene A
BACKGROUND: Traditional mitral annuloplasty devices include both rigid rings, which restrict annular motion, and soft rings and bands, which can locally deform. Conflicting data exist regarding their impact on annular dynamics. We studied mitral annuloplasty with a semirigid partial band and with a nearly complete rigid ring. METHODS: Intraoperative three-dimensional transesophageal echocardiograms (n = 14) and predischarge transthoracic echocardiograms were retrospectively analyzed in patients undergoing mitral valve repair for degenerative disease with either a rigid ring (n = 77) or a semirigid partial band (n = 38). Each transesophageal echocardiogram was analyzed with TomTec three-dimensional software to produce cardiac cycle frame planimetry and to measure device geometry. Actual device sizes provided reference dimensions. Blinded analysis of Doppler data from transthoracic echocardiograms was performed. RESULTS: Validation of the quantitative transesophageal echocardiogram methodology revealed a 1.3% +/- 0.3% (mean +/- standard error of the mean) underestimation of actual linear dimension. With the semirigid partial band, systolic valve orifice area and intertrigonal distance decreased from 6.14 +/- 0.37 to 5.55 +/- 0.24 cm(2) (-9.6%; p = 0.01) and from 2.69 +/- 0.08 to 2.55 +/- 0.13 cm (-5.2%; p = 0.03), respectively. Systolic anterior-posterior distance decreased from 2.1 +/- 0.10 to 1.95 +/- 0.06 cm (-7.1%; p = 0.01) compared with diastole. In contrast, rigid ring orifice area was unchanged (4.12 +/- 0.15 to 4.10 +/- 0.16 cm(2); -0.5%; p = 0.48) during the cardiac cycle. Transthoracic echocardiography revealed significantly lower mitral inflow gradients with semirigid partial band (mean gradients compared with rigid ring, 4.0 +/- 0.3 versus 5.0 +/- 0.3 mm Hg; p = 0.02; peak gradients, 8.9 +/- 0.5 versus 11.1 +/- 0.5 mm Hg; p = 0.01). CONCLUSIONS: Three-dimensional transesophageal echocardiographic measurements of annular dynamics are valid and reliable when discrete annuloplasty devices are present. In contrast to the rigid ring, the semirigid partial band permits more physiologic geometric changes and is associated with lower postoperative mitral valve gradients
PMID: 14759429
ISSN: 0003-4975
CID: 42597
Propensity case-matched analysis of off-pump coronary artery bypass grafting in patients with atheromatous aortic disease
Sharony, Ram; Grossi, Eugene A; Saunders, Paul C; Galloway, Aubrey C; Applebaum, Robert; Ribakove, Greg H; Culliford, Alfred T; Kanchuger, Marc; Kronzon, Itzhak; Colvin, Stephen B
OBJECTIVE: Atheromatous aortic disease is a risk factor for excessive mortality and stroke in patients undergoing coronary artery bypass grafting. Outcomes of off-pump coronary artery bypass grafting and coronary artery bypass grafting with cardiopulmonary bypass in patients with severe atheromatous aortic disease were compared by propensity case-match methods. METHODS: Routine intraoperative transesophageal echocardiography identified 985 patients undergoing isolated coronary artery bypass grafting with severe atheromatous disease in the aortic arch or ascending aorta. Off-pump coronary artery bypass grafting was performed in 281 patients (28.5%). Propensity matched-pairs analysis was used to match patients undergoing off-pump coronary artery bypass grafting (n = 245) with patients undergoing coronary artery bypass grafting with cardiopulmonary bypass. RESULTS: Univariate analysis revealed decreased hospital mortality (16/245, 6.5% vs 28/245, 11.4%; P =.058) and stroke prevalence (4/245, 1.6% vs 14/245, 5.7%; P =.03) in off-pump coronary artery bypass grafting compared with coronary artery bypass grafting with cardiopulmonary bypass. Freedom from any postoperative complication was higher in off-pump coronary artery bypass grafting compared with coronary artery bypass grafting with cardiopulmonary bypass (226/245, 92.2% vs 196/245, 80.0%; P <.001). Multivariable analysis of preoperative risk factors showed that increased hospital mortality was associated with coronary artery bypass grafting with cardiopulmonary bypass (odds ratio = 2.7; P =.01), fewer grafts (P =.05), acute myocardial infarction (odds ratio = 11.5; P <.001), chronic obstructive pulmonary disease (odds ratio = 2.4; P =.03), previous cardiac surgery (odds ratio = 10.2, P =.05), and peripheral vascular disease (odds ratio = 2.1; P =.05). Cardiopulmonary bypass was the only independent risk factor for stroke (odds ratio = 3.6, P =.03). At 36 months' follow-up, comparable survival was observed in the off-pump coronary artery bypass grafting and coronary artery bypass grafting with cardiopulmonary bypass groups (74% vs 72%). Multivariable analysis revealed that renal disease (P <.001), advanced age (P <.001), previous myocardial infarction (P =.03), and lower number of grafts (P =.02) were independent risks for late mortality. CONCLUSIONS: Patients with severe atherosclerotic aortic disease who undergo off-pump coronary artery bypass grafting have a significantly lower prevalence of hospital mortality, perioperative stroke, and overall complications than matched patients who underwent coronary artery bypass grafting with cardiopulmonary bypass. Routine intraoperative transesophageal echocardiography identifies severe atheromatous aortic disease and directs the choice of surgical technique
PMID: 14762348
ISSN: 0022-5223
CID: 42050
Failure of four bovine pericardial mitral prostheses
Saunders, Paul C; Grossi, Eugene A; Esposito, Rick A; Bizekis, Costas S; Strong, Michael D; Colvin, Stephen B
PMID: 14752441
ISSN: 0022-5223
CID: 42602
Anterior leaflet resection of the mitral valve
Saunders, Paul C; Grossi, Eugene A; Schwartz, Charles F; Grau, Juan B; Ribakove, Greg H; Culliford, Alfred T; Applebaum, Robert M; Galloway, Aubrey C; Colvin, Steven B
Triangular resection is a reconstructive option for treatment of anterior leaflet mitral disease with segmental prolapse. In our experience, it is a safe and reproducible technique, associated with low rates of recurrent MR or need for reoperation, as well as decreased likelihood for systolic anterior motion after mitral repair. We review our experience with this technique over a 25-year experience with mitral valve reconstruction
PMID: 15197696
ISSN: 1043-0679
CID: 45685