Try a new search

Format these results:

Searched for:

person:jazral01

Total Results:

355


Proximal biceps tendon--a biomechanical analysis of the stability at the bicipital groove

Kwon, Young W; Hurd, Jason; Yeager, Keith; Ishak, Charbel; Walker, Peter S; Khan, Sami; Bosco, Joseph A 3rd; Jazrawi, Laith M
The subscapularis tendon, coracohumeral ligament, and transverse humeral ligament are all believed to contribute to biceps tendon stability within the bicipital groove. In order to examine the relative contribution of these soft tissue structures to proximal biceps tendon stability, 11 fresh frozen cadaveric shoulder specimens were prepared and mounted onto a custom jig. A three-dimensional digitizer was utilized to record biceps tendon excursion in various shoulder positions. In sequential order, these structures were then sectioned, and biceps tendon excursion was again recorded. We found that sectioning of the subscapularis tendon significantly increased biceps tendon excursion, compared to intact specimens (8.1 +/- 4.1 mm vs. 4.3 +/- 3.6 mm; p < 0.006). In contrast, isolated sectioning of the transverse humeral ligament or the coracohumeral ligament did not significantly increase biceps excursion (5.4 +/- 2.5 mm, p = 0.26; 5.6 +/- 1.3 mm, p = 0.24). When two structures were sectioned, significant excursion in the biceps tendon only occurred in specimens where the subscapularis tendon was one of the sectioned structures. The preliminary data suggest that, of the three tested soft tissue structures, the subscapularis tendon is the most important stabilizer of the proximal biceps and that clinically significant lesions of the proximal biceps tendon may be associated with a defect in the subscapularis tendon
PMID: 20001935
ISSN: 1936-9727
CID: 105972

Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates

Egol, Kenneth A; Ong, Crispin C; Walsh, Michael; Jazrawi, Laith M; Tejwani, Nirmal C; Zuckerman, Joseph D
PURPOSE: To examine our incidence of early complications that occur using the Proximal Humeral Internal Locking System (PHILOS) and to determine the contributing factors. SETTING: Academic medical center. PATIENTS: Fifty-one consecutive patients treated with a proximal humerus locking plate. OUTCOME: Development of an intraoperative, acute postoperative, or delayed postoperative complication. METHODS: A retrospective analysis was undertaken of a consecutive series of proximal humerus fractures treated with a locking plate between February 2003 and January 2006 at our institution. Fifty-one fractures or fracture nonunions were identified in 18 male and 33 female patients with an average age of 61. All acute injuries were treated with a similar protocol of open reduction internal fixation with the PHILOS plate followed by early range of shoulder motion. Nonunions were treated in a similar manner with the addition of iliac crest bone graft placement. Patients were objectively assessed on their outcome by physical as well as radiological examination. All complications were recorded. Statistical analyses were performed to determine if patient age, fracture type, or number of screws placed in the humeral head contributed to complications. RESULTS: Fifty-one patients were available for minimum 6-month follow-up (mean, 16 months; range, 6 to 45 months). Radiographically, 92% of the cases united at 3 months after surgery, and 2 fractures had signs of osteonecrosis at latest follow-up. Sixteen complications were seen in 12 patients (24%). Eight shoulders in eight patients (16%) had screws that penetrated the humeral head. Two patients developed osteonecrosis at latest follow-up. One acute fracture and one nonunion failed to unite after index surgery. Significant heterotopic bone developed in 1 patient. Early implant failure occurred in 2 patients; one was revised to a longer plate, and one underwent resection arthroplasty. There was one acute postoperative infection. CONCLUSION: The major complication reported in this study was screw penetration, suggesting that exceptional vigilance must be taken in estimating the appropriate number and length of screws used to prevent articular penetration; although the device provides exceptional fixation stability, its indication must be scrutinized for each individual patient, taking the extent of trauma/fracture and age into consideration and carefully weighing it against other forms of treatment
PMID: 18317048
ISSN: 0890-5339
CID: 76798

Distal clavicular osteolysis: a review of the literature

Schwarzkopf, Ran; Ishak, Charbel; Elman, Michael; Gelber, Jonathan; Strauss, David N; Jazrawi, Laith M
Acute distal clavicular osteolysis was first described in 1936. Since then, distal clavicular osteolysis (DCO) has been separated into traumatic and atraumatic pathogeneses. In 1982 the first series of male weight trainers who developed ADCO was reported. The association of weightlifting and ADCO is especially important considering how routine a component weights are to the male athlete's training. The pathogenesis of DCO has often been debated. The most widely accepted etiology involves a connection between microfractures of the subchondral bone and subsequent attempts at repair, which is consistent with repetitive microtrauma. Symptoms usually begin with an insidious aching pain in the AC region that is exacerbated by weight training. On examination, patients have point tenderness over the affected AC joint and pain with a cross-body adduction maneuver. Although DCO may seem like an easy and quick diagnosis, one must rule out other possibilities. Avoidance of provocative maneuvers, modification of weight training techniques, ice massage, and nonsteroidal anti-inflammatory drugs (NSAID) constitute the basis of initial treatment. Much of the literature supports the same general indications for surgery. These include point tenderness of the AC joint, evident abnormal signs with AC joint scintigraphy and AC radiographs, lack of response to conservative treatment, and an unwillingness to give up or modify weight training or manual labor. Distal clavicle resection has provided good results. Distal clavicle osteolysis is a unique disease most likely due to an overuse phenomenon
PMID: 18537776
ISSN: 1936-9719
CID: 93315

Effect of specialty and experience on the interpretation of knee MRI scans

Kim, Allis; Khoury, Lisa; Schweitzer, Mark; Jazrawi, Laith; Ishak, Charbel; Meislin, Robert; Kummer, Fred; Sherman, Orrin H
The purpose of this study was to evaluate any differences in the accuracy of knee MRI interpretation between radiology and orthopaedic surgery residents as well as to evaluate differences in quality of interpretation relative to resident training level. In this study, 20 MRI scans demonstrating specific pathology of the knee were identified. From one institution, two radiology residents and two orthopaedic surgery residents of each postgraduate year (PGY) of training (2 to 5) were recruited. Each resident was asked to interpret all the studies and choose up to 16 diagnoses for each scan from the list provided. Orthopaedic surgery residents showed improvement in overall accuracy and specificity with each year of additional training. Level of training did not correspond with increased sensitivity in the orthopaedic residents tested. Radiology residents did not demonstrate a consistent trend toward improved accuracy, sensitivity, or specificity with additional years of training. The only statistically significant differences in specificity observed between the two groups were seen in the readings of ACL tears, lateral femoral condyle chondromalacia, and chondromalacia patella. This study found that the accuracy of knee MRI interpretations between radiology and orthopaedic surgery residents did not demonstrate any differences. Level of training had no effect on the interpretation of the MRIs by radiology residents. Orthopaedic surgery residents did show an improvement with each year of additional training
PMID: 19093902
ISSN: 1936-9719
CID: 94695

Initial loop and knot security of arthroscopic knots using high-strength sutures

Shah, Mehul R; Strauss, Eric J; Kaplan, Kevin; Jazrawi, Laith; Rosen, Jeffrey
Purpose: There are many options for arthroscopic knots including the type of knot and suture material used. The current investigation evaluated knot properties using 3 high-strength suture materials tied in 5 common arthroscopic knot configurations. Methods: Four arthroscopic sliding knots including the Roeder, Weston, SMC, and Tennessee Slider and an arthroscopic nonsliding Surgeon's knot were evaluated. Each knot was tied with each of 3 No. 2 polyblended suture types (Fiberwire [Arthrex, Naples, FL], Ultrabraid [Smith & Nephew, Andover, MA], and Orthocord [Mitek, Raynham, MA]). Each configuration was tied 8 times, for a total of 120 samples. Loop security and knot security were then evaluated by using a previously described protocol comparing the different knot types and suture material. Results: With respect to loop security, Orthocord performed better than the other tested suture materials, producing on average smaller knot loops. For the nonsliding Surgeon's knot, there was no difference in loop security observed between suture types. For the Roeder knot, Fiberwire had superior knot security compared with Ultrabraid and Orthocord (P < .001). For the Weston knot, Ultrabraid showed superior knot security compared with Orthocord (P < .02). Knot security for the Tenessee slider knot was better for both Fiberwire and Ultrabraid compared with Orthocord (P < .001, respectively). Similar results were seen with the SMC knot, with Fiberwire and Ultrabraid outperforming Orthocord (P < .001, respectively). The nonsliding Surgeon's knot had significantly lower mean loads to failure compared with arthroscopic sliding knots for each tested suture material (P < .02 for all comparisons). Conclusions: Loop security and knot security varied depending on the type of knot tied and suture material used. Arthroscopic sliding knots performed better than the nonsliding Surgeon's knot. Clinical Relevance: Surgeons should try to use sliding knots instead of Surgeon's knots when using polyblend suture material. Differences between the brands in this suture category will change the characteristics of the knots thrown and may ultimately affect tissue fixation
PMID: 17681211
ISSN: 1526-3231
CID: 73341

Effect of tibial positioning on the diagnosis of posterolateral rotatory instability in the posterior cruciate ligament-deficient knee

Strauss, Eric J; Ishak, Charbel; Inzerillo, Christopher; Walsh, Michael; Yildirim, Gokce; Walker, Peter; Jazrawi, Laith; Rosen, Jeffrey
OBJECTIVE: To determine whether positioning of the tibia affects the degree of tibial external rotation seen during a dial test in the posterior cruciate ligament (PCL)-posterolateral corner (PLC)-deficient knee. DESIGN: Laboratory investigation. SETTING: Biomechanics laboratory. Hypothesis: An anterior force applied to the tibia in the combined PCL-PLC-deficient knee will yield increased tibial external rotation during a dial test. METHODS: The degree of tibial external rotation was measured with 5 Nm of external rotation torque applied to the tibia at both 30 degrees and 90 degrees of knee flexion. Before the torque was applied, an anterior force, a posterior force, or neutral (normal, reduced control) force was applied to the tibia. External rotation measurements were repeated after sequential sectioning of the PCL, the posterolateral structures and the fibular collateral ligament (FCL). RESULTS: Baseline testing of the intact specimens demonstrated a mean external rotation of 18.6 degrees with the knee flexed to 30 degrees (range 16.1-21.0 degrees ), and a mean external rotation of 17.3 degrees with the knee flexed to 90 degrees (range 13.8-20.0 degrees ). Sequential sectioning of the PCL, popliteus and popliteofibular ligament, and the FCL led to a significant increase in tibial external rotation compared with the intact knee for all testing scenarios. After sectioning of the popliteus and popliteofibular ligament, the application of an anterior force during testing led to a mean tibial external rotation that was 5 degrees greater than during testing in the neutral position and 7.5 degrees greater than during testing with a posterior force. In the PCL, popliteus/popliteofibular ligament and FCL-deficient knee, external rotation was 9 degrees and 12 degrees greater with the application of an anterior force during testing compared with neutral positioning and the application of a posterior force, respectively. CONCLUSION: An anterior force applied to the tibia during the dial test in a combined PCL-PLC-injured knee increased the overall amount of observed tibial external rotation during the dial test. The anterior force reduced the posterior tibial subluxation associated with PCL injury, which is analogous to what is observed when the dial test is performed with the patient in the prone position. Reducing the tibia with either an anterior force when the patient is supine or performing the dial test with the patient in the prone position increases the ability of an examiner to detect a concomitant PLC injury in the setting of a PCL-deficient knee
PMCID:2465456
PMID: 17261553
ISSN: 1473-0480
CID: 73874

Operative treatment of acute Achilles tendon ruptures: an institutional review of clinical outcomes

Strauss, Eric J; Ishak, Charbel; Jazrawi, Laith; Sherman, Orrin; Rosen, Jeffrey
PURPOSE: To retrospectively review the clinical outcome and incidence of post-operative complications after open end-to-end repair of acute Achilles tendon ruptures. METHODS: Seventy consecutive patients (74 open Achilles tendon repairs) operated on between 1989 and 2002 were identified for inclusion in this investigation. The medical records were reviewed and patients were contacted for a follow up interview in order to survey their post-operative function. Outcome scores were calculated based on the Boyden outcome and AOFAS ankle-hindfoot scoring systems. Post-operative complications were documented during the chart review and follow up interview, including an additional nine patients (nine repairs), who were not included in the clinical evaluation portion of the study. RESULTS: Fifty-two patients (54 repairs) were successfully contacted and completed the follow up interview. Within this cohort there were 44 males and 8 females with a mean age of 41 years. Achilles tendon rupture in this population was attributable to participation in athletic activity in 87% of cases. At a mean post-operative follow up of 45 months, 96% of cases achieved an overall Boyden outcome score of good to excellent. The mean AOFAS ankle-hindfoot score was 96, with 74% of cases scoring greater than 90. Forty-two cases (78%) reported no pain and 40 cases (74%) reported no activity limitations. Fourteen post-operative complications were identified after 83 open Achilles tendon repairs, resulting in an institutional complication rate of 16.8%. The complications included four superficial wound infections, five deep wound infections requiring irrigation and debridement, one heel ulcer secondary to post-operative boot wear, three partial Achilles tendon re-ruptures, and one complete Achilles tendon re-rupture. CONCLUSION: Our results demonstrate that open end-to-end repair of acute Achilles tendon ruptures provides long-term functional outcomes with consistent good to excellent results. However, this high clinical success rate was associated with a relatively high incidence of post-operative complications. With careful attention to the surgical wound and patient adherence to post-operative rehabilitation protocols, operative repair of acute Achilles tendon ruptures is a reliable treatment for active patients
PMID: 16945370
ISSN: 0020-1383
CID: 74164

The effect of cartilage-derived morphogenetic protein 2 on initial healing of a rotator cuff defect in a rat model

Murray, Douglas H; Kubiak, Erik N; Jazrawi, Laith M; Araghi, Arash; Kummer, Frederick; Loebenberg, Mark I; Zuckerman, Joseph D
This animal study evaluated the healing of supraspinatus tendon tears by use of a cartilage-derived morphogenetic protein 2 growth factor (CDMP-2) delivered to the repair. Forty-eight rats had bilateral, surgically created complete tears repaired by sutures with the growth factor introduced on one side. They were killed at 2, 3, 4, and 6 weeks, and the strength of the repairs was determined and histologic analysis performed. At 4 and 6 weeks, the CDMP-2-treated repairs were significantly stronger than the untreated repairs and histologic analysis showed more organized healing. The use of growth factors introduced at the time of rotator cuff repair might promote more rapid healing and subsequent, rapid patient rehabilitation
PMID: 17113320
ISSN: 1532-6500
CID: 70978

The modified racking hitch(MRH) knot: a new sliding knot for arthroscopic surgery

Chokshi, Biren V; Ishak, Charbel; Iesaka, Kazuho; Jazrawi, Laith M; Kummer, Frederic J; Rosen, Jeffrey E
Sliding knots are commonly used in arthroscopic surgery and can be problematic in terms of strength and loop security. A new sliding knot for arthroscopic surgery, a modified racking hitch (MRH) knot, is described. The knot is essentially a modified cow's hitch knot that includes two self-locking loops. By tensioning the loop strands, a snug knot is created without backward sliding and provides excellent knot and loop security. In laboratory testing, the MRH knot provided comparable strength and security to other sliding knots. Experience gained from approximately 5 years of clinical use has added to the promise of the useful application of the MRH knot in arthroscopy
PMID: 18081550
ISSN: 1936-9719
CID: 76150

Surgical management of os acromiale: a case report and review of the literature [Case Report]

Sahajpal, Deenesh; Strauss, Eric J; Ishak, Charbel; Keyes, J M O'Malley; Joseph, George; Jazrawi, Laith M
PMID: 18081552
ISSN: 1936-9719
CID: 76152