Try a new search

Format these results:

Searched for:

person:svirsm01 or azadpm01 or sagie01 or Nicole Capach (capacn01)

Total Results:

175


A Smartphone Application for Customized Frequency Table Selection in Cochlear Implants

Jethanamest, Daniel; Azadpour, Mahan; Zeman, Annette M; Sagi, Elad; Svirsky, Mario A
HYPOTHESIS: A novel smartphone-based software application can facilitate self-selection of frequency allocation tables (FAT) in postlingually deaf cochlear implant (CI) users. BACKGROUND: CIs use FATs to represent the tonotopic organization of a normal cochlea. Current CI fitting methods typically use a standard FAT for all patients regardless of individual differences in cochlear size and electrode location. In postlingually deaf patients, different amounts of mismatch can result between the frequency-place function they experienced when they had normal hearing and the frequency-place function that results from the standard FAT. For some CI users, an alternative FAT may enhance sound quality or speech perception. Currently, no widely available tools exist to aid real-time selection of different FATs. This study aims to develop a new smartphone tool for this purpose and to evaluate speech perception and sound quality measures in a pilot study of CI subjects using this application. METHODS: A smartphone application for a widely available mobile platform (iOS) was developed to serve as a preprocessor of auditory input to a clinical CI speech processor and enable interactive real-time selection of FATs. The application's output was validated by measuring electrodograms for various inputs. A pilot study was conducted in six CI subjects. Speech perception was evaluated using word recognition tests. RESULTS: All subjects successfully used the portable application with their clinical speech processors to experience different FATs while listening to running speech. The users were all able to select one table that they judged provided the best sound quality. All subjects chose a FAT different from the standard FAT in their everyday clinical processor. Using the smartphone application, the mean consonant-nucleus-consonant score with the default FAT selection was 28.5% (SD 16.8) and 29.5% (SD 16.4) when using a self-selected FAT. CONCLUSION: A portable smartphone application enables CI users to self-select frequency allocation tables in real time. Even though the self-selected FATs that were deemed to have better sound quality were only tested acutely (i.e., without long-term experience with them), speech perception scores were not inferior to those obtained with the clinical FATs. This software application may be a valuable tool for improving future methods of CI fitting.
PMCID:5556943
PMID: 28806335
ISSN: 1537-4505
CID: 2669212

Cochlear implants and electronic hearing

Svirsky, Mario
ISI:000407102700022
ISSN: 1945-0699
CID: 2675482

Enhancing Intervention for Residual Rhotic Errors Via App-Delivered Biofeedback: A Case Study

Byun, Tara McAllister; Campbell, Heather; Carey, Helen; Liang, Wendy; Park, Tae Hong; Svirsky, Mario
Purpose: Recent research suggests that visual-acoustic biofeedback can be an effective treatment for residual speech errors, but adoption remains limited due to barriers including high cost and lack of familiarity with the technology. This case study reports results from the first participant to complete a course of visual-acoustic biofeedback using a not-for-profit iOS app, Speech Therapist's App for /r/ Treatment. Method: App-based biofeedback treatment for rhotic misarticulation was provided in weekly 30-min sessions for 20 weeks. Within-treatment progress was documented using clinician perceptual ratings and acoustic measures. Generalization gains were assessed using acoustic measures of word probes elicited during baseline, treatment, and maintenance sessions. Results: Both clinician ratings and acoustic measures indicated that the participant significantly improved her rhotic production accuracy in trials elicited during treatment sessions. However, these gains did not transfer to generalization probes. Conclusions: This study provides a proof-of-concept demonstration that app-based biofeedback is a viable alternative to costlier dedicated systems. Generalization of gains to contexts without biofeedback remains a challenge that requires further study. App-delivered biofeedback could enable clinician-research partnerships that would strengthen the evidence base while providing enhanced treatment for children with residual rhotic errors. Supplemental Material: https://doi.org/10.23641/asha.5116318.
PMCID:5544407
PMID: 28655050
ISSN: 1558-9102
CID: 2613622

Self-Selection of Frequency Tables with Bilateral Mismatches in an Acoustic Simulation of a Cochlear Implant

Fitzgerald, Matthew B; Prosolovich, Ksenia; Tan, Chin-Tuan; Glassman, E Katelyn; Svirsky, Mario A
BACKGROUND: Many recipients of bilateral cochlear implants (CIs) may have differences in electrode insertion depth. Previous reports indicate that when a bilateral mismatch is imposed, performance on tests of speech understanding or sound localization becomes worse. If recipients of bilateral CIs cannot adjust to a difference in insertion depth, adjustments to the frequency table may be necessary to maximize bilateral performance. PURPOSE: The purpose of this study was to examine the feasibility of using real-time manipulations of the frequency table to offset any decrements in performance resulting from a bilateral mismatch. RESEARCH DESIGN: A simulation of a CI was used because it allows for explicit control of the size of a bilateral mismatch. Such control is not available with users of CIs. STUDY SAMPLE: A total of 31 normal-hearing young adults participated in this study. DATA COLLECTION AND ANALYSIS: Using a CI simulation, four bilateral mismatch conditions (0, 0.75, 1.5, and 3 mm) were created. In the left ear, the analysis filters and noise bands of the CI simulation were the same. In the right ear, the noise bands were shifted higher in frequency to simulate a bilateral mismatch. Then, listeners selected a frequency table in the right ear that was perceived as maximizing bilateral speech intelligibility. Word-recognition scores were then assessed for each bilateral mismatch condition. Listeners were tested with both a standard frequency table, which preserved a bilateral mismatch, or with their self-selected frequency table. RESULTS: Consistent with previous reports, bilateral mismatches of 1.5 and 3 mm yielded decrements in word recognition when the standard table was used in both ears. However, when listeners used the self-selected frequency table, performance was the same regardless of the size of the bilateral mismatch. CONCLUSIONS: Self-selection of a frequency table appears to be a feasible method for ameliorating the negative effects of a bilateral mismatch. These data may have implications for recipients of bilateral CIs who cannot adapt to a bilateral mismatch, because they suggest that (1) such individuals may benefit from modification of the frequency table in one ear and (2) self-selection of a "most intelligible" frequency table may be a useful tool for determining how the frequency table should be altered to optimize speech recognition.
PMCID:5563263
PMID: 28534729
ISSN: 2157-3107
CID: 2574732

Pitch Matching between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Contralateral Ear with Residual Hearing

Tan, Chin-Tuan; Martin, Brett; Svirsky, Mario A
BACKGROUND: Cochlear implants (CIs) successfully restore hearing in postlingually deaf adults, but in doing so impose a frequency-position function in the cochlea that may differ from the physiological one. PURPOSE: The CI-imposed frequency-position function is determined by the frequency allocation table programmed into the listener's speech processor and by the location of the electrode array along the cochlea. To what extent can postlingually deaf CI users successfully adapt to the difference between physiological and CI-imposed frequency-position functions? RESEARCH DESIGN: We attempt to answer the question by combining behavioral measures of electroacoustic pitch matching (PM) and measures of electrode location within the cochlea. STUDY SAMPLE: The participants in this study were 16 adult CI users with residual hearing who could match the pitch of acoustic pure tones presented to their unimplanted ears to the pitch resulting from stimulation of different CI electrodes. DATA COLLECTION AND ANALYSIS: We obtained data for four to eight apical electrodes from 16 participants with CIs (most of whom were long-term users), and estimated electrode insertion angle for 12 of these participants. PM functions in this group were compared with the two frequency-position functions discussed above. RESULTS: Taken together, the findings were consistent with the possibility that adaptation to the frequency-position function imposed by CIs does happen, but it is not always complete. CONCLUSIONS: Some electrodes continue to be perceived as higher pitched than the acoustic frequencies with which they are associated despite years of listening experience after cochlear implantation.
PMCID:5435235
PMID: 28277210
ISSN: 2157-3107
CID: 2476332

Contribution of formant frequency information to vowel perception in steady-state noise by cochlear implant users

Sagi, Elad; Svirsky, Mario A
Cochlear implant (CI) recipients have difficulty understanding speech in noise even at moderate signal-to-noise ratios. Knowing the mechanisms they use to understand speech in noise may facilitate the search for better speech processing algorithms. In the present study, a computational model is used to assess whether CI users' vowel identification in noise can be explained by formant frequency cues (F1 and F2). Vowel identification was tested with 12 unilateral CI users in quiet and in noise. Formant cues were measured from vowels in each condition, specific to each subject's speech processor. Noise distorted the location of vowels in the F2 vs F1 plane in comparison to quiet. The best fit model to subjects' data in quiet produced model predictions in noise that were within 8% of actual scores on average. Predictions in noise were much better when assuming that subjects used a priori knowledge regarding how formant information is degraded in noise (experiment 1). However, the model's best fit to subjects' confusion matrices in noise was worse than in quiet, suggesting that CI users utilize formant cues to identify vowels in noise, but to a different extent than how they identify vowels in quiet (experiment 2).
PMCID:5392095
PMID: 28253672
ISSN: 1520-8524
CID: 2471552

Self-Reported Usage, Functional Benefit, and Audiologic Characteristics of Cochlear Implant Patients Who Use a Contralateral Hearing Aid

Neuman, Arlene C; Waltzman, Susan B; Shapiro, William H; Neukam, Jonathan D; Zeman, Annette M; Svirsky, Mario A
Ninety-four unilateral CI patients with bimodal listening experience (CI plus HA in contralateral ear) completed a questionnaire that focused on attitudes toward hearing aid use postimplantation, patterns of usage, and perceived bimodal benefits in daily life. Eighty participants continued HA use and 14 discontinued HA use at the time of the questionnaire. Participant responses provided useful information for counseling patients both before and after implantation. The majority of continuing bimodal (CI plus HA) participants reported adapting to using both devices within 3 months and also reported that they heard better bimodally in quiet, noisy, and reverberant conditions. They also perceived benefits including improved sound quality, better music enjoyment, and sometimes a perceived sense of acoustic balance. Those who discontinued HA use found either that using the HA did not provide additional benefit over the CI alone or that using the HA degraded the signal from the CI. Because there was considerable overlap in the audiograms and in speech recognition performance in the unimplanted ear between the two groups, we recommend that unilateral CI recipients are counseled to continue to use the HA in the contralateral ear postimplantation in order to determine whether or not they receive functional or perceived benefit from using both devices together.
PMCID:5435367
PMID: 28351216
ISSN: 2331-2165
CID: 2508302

Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array

Svrakic, Maja; Roland, J Thomas Jr; McMenomey, Sean O; Svirsky, Mario A
OBJECTIVE: To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE). STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: Sixty-three MSE implants in pediatric and adult patients were compared with age- and sex-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. INTERVENTION: Cochlear implantation with either the AB 1j electrode or the AB MSE. MAIN OUTCOME MEASURES: The MSE and 1j electrodes were compared in their angular depth of insertion and pre to postoperative change in hearing thresholds. Hearing preservation was analyzed as a function of angular depth of insertion. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. RESULTS: Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2000 Hz were 10, 7, 2, and 6 dB smaller for the MSE electrode than for the 1j (p < 0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. CONCLUSION: The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect.
PMCID:5104204
PMID: 27755356
ISSN: 1537-4505
CID: 2279922

Enhancing speech envelope by integrating hair-cell adaptation into cochlear implant processing

Azadpour, Mahan; Smith, Robert L
Cochlear implants (CIs) bypass some of the mechanisms that underlie normal neural behavior as occurs in acoustic hearing. One such neural mechanism is short-term adaptation, which has been proposed to have a significant role in speech perception. Acoustically-evoked neural adaptation has been mainly attributed to the depletion of neurotransmitter in the hair-cell to auditory-nerve synapse and is therefore not fully present in CI stimulation. This study evaluated a signal processing method that integrated a physiological model of hair-cell adaptation into CI speech processing. The linear high-pass adaptation process expanded the range of rapid variations of the electrical signal generated by the clinical processing strategy. Speech perception performance with the adaptation-based processing was compared to that of the clinical strategy in seven CI users. While there was large variability across subjects, the new processing improved sentence recognition and consonant identification scores in quiet in all the tested subjects with an average improvement of 8% and 6% respectively. Consonant recognition scores in babble noise were improved at the higher signal-to-noise ratios tested (10 and 6 dB) only. Information transfer analysis of consonant features showed significant improvements for manner and place of articulation features, but not for voicing. Enhancement of within-channel envelope cues was confirmed by consonant recognition results obtained with single-channel strategies that presented the overall amplitude envelope of the signal on a single active electrode. Adaptation-inspired envelope enhancement techniques can potentially improve perception of important speech features by CI users.
PMID: 27697486
ISSN: 1878-5891
CID: 2386102

A physiological and behavioral system for hearing restoration with cochlear implants

King, Julia; Shehu, Ina; Roland, J Thomas Jr; Svirsky, Mario A; Froemke, Robert C
Cochlear implants are neuroprosthetic devices that provide hearing to deaf patients, although outcomes are highly variable even with prolonged training and use. The central auditory system must process cochlear implant signals, but it is unclear how neural circuits adapt - or fail to adapt - to such inputs. Understanding these mechanisms is required for development of next-generation neuroprosthetics that interface with existing neural circuits and enable synaptic plasticity to improve perceptual outcomes. Here we describe a new system for cochlear implant insertion, stimulation, and behavioral training in rats. Animals were first ensured to have significant hearing loss via physiological and behavioral criteria. We developed a surgical approach for multi-channel (2-channel or 8-channel) array insertion, comparable to implantation procedures and depth in humans. Peripheral and cortical responses to stimulation were used to objectively program the implant. Animals fitted with implants learned to use them for an auditory-dependent task that assesses frequency detection and recognition, in a background of environmentally- and self-generated noise, and ceased responding appropriately to sounds when the implant was temporarily inactivated. This physiologically-calibrated and behaviorally-validated system provides a powerful opportunity to study the neural basis of neuroprosthetic device use and plasticity.
PMCID:4995281
PMID: 27281743
ISSN: 1522-1598
CID: 2136552