Searched for: person:svirsm01 or azadpm01 or sagie01 or Nicole Capach (capacn01)
The Effect of Hearing Aid Bandwidth and Configuration of Hearing Loss on Bimodal Speech Recognition in Cochlear Implant Users
Neuman, Arlene C; Zeman, Annette; Neukam, Jonathan; Wang, Binhuan; Svirsky, Mario A
OBJECTIVES/OBJECTIVE:(1) To determine the effect of hearing aid (HA) bandwidth on bimodal speech perception in a group of unilateral cochlear implant (CI) patients with diverse degrees and configurations of hearing loss in the nonimplanted ear, (2) to determine whether there are demographic and audiometric characteristics that would help to determine the appropriate HA bandwidth for a bimodal patient. DESIGN/METHODS:Participants were 33 experienced bimodal device users with postlingual hearing loss. Twenty three of them had better speech perception with the CI than the HA (CI>HA group) and 10 had better speech perception with the HA than the CI (HA>CI group). Word recognition in sentences (AzBio sentences at +10 dB signal to noise ratio presented at 0° azimuth) and in isolation [CNC (consonant-nucleus-consonant) words] was measured in unimodal conditions [CI alone or HAWB, which indicates HA alone in the wideband (WB) condition] and in bimodal conditions (BMWB, BM2k, BM1k, and BM500) as the bandwidth of an actual HA was reduced from WB to 2 kHz, 1 kHz, and 500 Hz. Linear mixed-effect modeling was used to quantify the relationship between speech recognition and listening condition and to assess how audiometric or demographic covariates might influence this relationship in each group. RESULTS:For the CI>HA group, AzBio scores were significantly higher (on average) in all bimodal conditions than in the best unimodal condition (CI alone) and were highest at the BMWB condition. For CNC scores, on the other hand, there was no significant improvement over the CI-alone condition in any of the bimodal conditions. The opposite pattern was observed in the HA>CI group. CNC word scores were significantly higher in the BM2k and BMWB conditions than in the best unimodal condition (HAWB), but none of the bimodal conditions were significantly better than the best unimodal condition for AzBio sentences (and some of the restricted bandwidth conditions were actually worse). Demographic covariates did not interact significantly with bimodal outcomes, but some of the audiometric variables did. For CI>HA participants with a flatter audiometric configuration and better mid-frequency hearing, bimodal AzBio scores were significantly higher than the CI-alone score with the WB setting (BMWB) but not with other bandwidths. In contrast, CI>HA participants with more steeply sloping hearing loss and poorer mid-frequency thresholds (≥82.5 dB) had significantly higher bimodal AzBio scores in all bimodal conditions, and the BMWB did not differ significantly from the restricted bandwidth conditions. HA>CI participants with mild low-frequency hearing loss showed the highest levels of bimodal improvement over the best unimodal condition on CNC words. They were also less affected by HA bandwidth reduction compared with HA>CI participants with poorer low-frequency thresholds. CONCLUSIONS:The pattern of bimodal performance as a function of the HA bandwidth was found to be consistent with the degree and configuration of hearing loss for both patients with CI>HA performance and for those with HA>CI performance. Our results support fitting the HA for all bimodal patients with the widest bandwidth consistent with effective audibility.
PMID: 30067559
ISSN: 1538-4667
CID: 3217482
Locus coeruleus activation accelerates perceptual learning
Glennon, Erin; Carcea, Ioana; Martins, Ana Raquel O; Multani, Jasmin; Shehu, Ina; Svirsky, Mario A; Froemke, Robert C
Neural representations of the external world are constructed and updated in a manner that depends on behavioral context. For neocortical networks, this contextual information is relayed by a diverse range of neuromodulatory systems, which govern attention and signal the value of internal state variables such as arousal, motivation, and stress. Neuromodulators enable cortical circuits to differentially process specific stimuli and modify synaptic strengths in order to maintain short- or long-term memory traces of significant perceptual events and behavioral episodes. One of the most important subcortical neuromodulatory systems for attention and arousal is the noradrenergic locus coeruleus. Here we report that the noradrenergic system can enhance behavior in rats performing a self-initiated auditory recognition task, and optogenetic stimulation of noradrenergic locus coeruleus neurons accelerated the rate at which trained rats began correctly responding to a change in reward contingency. Animals successively progressed through distinct behavioral epochs, including periods of perseverance and exploration that occurred much more rapidly when animals received locus coeruleus stimulation. In parallel, we made recordings from primary auditory cortex and found that pairing tones with locus coeruleus stimulation led to a similar set of changes to cortical tuning profiles. Thus both behavioral and neural responses go through phases of adjustment for exploring and exploiting environmental reward contingencies. Furthermore, behavioral engagement does not necessarily recruit optimal locus coeruleus activity.
PMID: 29859972
ISSN: 1872-6240
CID: 3144272
Deactivating cochlear implant electrodes to improve speech perception: A computational approach
Sagi, Elad; Svirsky, Mario A
A potential bottleneck to improving speech perception performance in cochlear implant (CI) users is that some of their electrodes may poorly encode speech information. Several studies have examined the effect of deactivating poorly encoding electrodes on speech perception with mixed results. Many of these studies focused on identifying poorly encoding electrodes by some measure (e.g. electrode discrimination, pitch ordering, threshold, CT-guided, masked modulation detection), but provide inconsistent criteria about which electrodes, and how many, should be deactivated, and without considering how speech information becomes distributed across the electrode array. The present simulation study addresses this issue using computational approaches. Previously validated models were used to generate predictions of speech scores as a function of all possible combinations of active electrodes in a 22-electrode array in three groups of hypothetical subjects representative of relatively better, moderate, and poorer performing CI users. Using high-performance computing, over 500 million predictions were generated. Although deactivation of the poorest encoding electrodes sometimes resulted in predicted benefit, this benefit was significantly less relative to predictions resulting from model-optimized deactivations. This trend persisted when using novel stimuli (i.e. other than those used for optimization) and when using different processing strategies. Optimum electrode deactivation patterns produced an average predicted increase in word scores of 10% with some scores increasing by more than 20%. Optimum electrode deactivation patterns typically included 11 to 19 (out of 22) active electrodes, depending on the performance group. Optimal active electrode combinations were those that maximized discrimination of speech cues, maintaining 80%-100% of the physical span of the array. The present study demonstrates the potential for further improving CI users' speech scores with appropriate selection of active electrodes.
PMID: 30396747
ISSN: 1878-5891
CID: 3455692
A potential neurophysiological correlate of electric-acoustic pitch matching in adult cochlear implant users: Pilot data
Tan, Chin-Tuan; Martin, Brett A; Svirsky, Mario A
The overall goal of this study was to identify an objective physiological correlate of electric-acoustic pitch matching in unilaterally implanted cochlear implant (CI) participants with residual hearing in the non-implanted ear. Electrical and acoustic stimuli were presented in a continuously alternating fashion across ears. The acoustic stimulus and the electrical stimulus were either matched or mismatched in pitch. Auditory evoked potentials were obtained from nine CI users. Results indicated that N1 latency was stimulus-dependent, decreasing when the acoustic frequency of the tone presented to the non-implanted ear was increased. More importantly, there was an additional decrease in N1 latency in the pitch-matched condition. These results indicate the potential utility of N1 latency as an index of pitch matching in CI users.
PMCID:6123823
PMID: 29508662
ISSN: 1754-7628
CID: 2992042
Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users
Azadpour, Mahan; McKay, Colette M; Svirsky, Mario A
Stimulation pulse rate affects current amplitude discrimination by cochlear implant (CI) users, indicated by the evidence that the JND (just noticeable difference) in current amplitude delivered by a CI electrode becomes larger at higher pulse rates. However, it is not clearly understood whether pulse rate would affect discrimination of speech intensities presented acoustically to CI processors, or what the size of this effect might be. Intensity discrimination depends on two factors: the growth of loudness with increasing sound intensity and the loudness JND (or the just noticeable loudness increment). This study evaluated the hypothesis that stimulation pulse rate affects loudness JND. This was done by measuring current amplitude JNDs in an experiment design based on signal detection theory according to which loudness discrimination is related to internal noise (which is manifested by variability in loudness percept in response to repetitions of the same physical stimulus). Current amplitude JNDs were measured for equally loud pulse trains of 500 and 3000Â pps (pulses per second) by increasing the current amplitude of the target pulse train until it was perceived just louder than a same-rate or different-rate reference pulse train. The JND measures were obtained at two presentation levels. At the louder level, the current amplitude JNDs were affected by the rate of the reference pulse train in a way that was consistent with greater noise or variability in loudness perception for the higher pulse rate. The results suggest that increasing pulse rate from 500 to 3000Â pps can increase loudness JND by 60Â % at the upper portion of the dynamic range. This is equivalent to a 38Â % reduction in the number of discriminable steps for acoustic and speech intensities.
PMCID:5962473
PMID: 29532190
ISSN: 1438-7573
CID: 2992622
Cochlear implants and electronic hearing
Svirsky, Mario
ISI:000407102700022
ISSN: 1945-0699
CID: 2675482
A Smartphone Application for Customized Frequency Table Selection in Cochlear Implants
Jethanamest, Daniel; Azadpour, Mahan; Zeman, Annette M; Sagi, Elad; Svirsky, Mario A
HYPOTHESIS: A novel smartphone-based software application can facilitate self-selection of frequency allocation tables (FAT) in postlingually deaf cochlear implant (CI) users. BACKGROUND: CIs use FATs to represent the tonotopic organization of a normal cochlea. Current CI fitting methods typically use a standard FAT for all patients regardless of individual differences in cochlear size and electrode location. In postlingually deaf patients, different amounts of mismatch can result between the frequency-place function they experienced when they had normal hearing and the frequency-place function that results from the standard FAT. For some CI users, an alternative FAT may enhance sound quality or speech perception. Currently, no widely available tools exist to aid real-time selection of different FATs. This study aims to develop a new smartphone tool for this purpose and to evaluate speech perception and sound quality measures in a pilot study of CI subjects using this application. METHODS: A smartphone application for a widely available mobile platform (iOS) was developed to serve as a preprocessor of auditory input to a clinical CI speech processor and enable interactive real-time selection of FATs. The application's output was validated by measuring electrodograms for various inputs. A pilot study was conducted in six CI subjects. Speech perception was evaluated using word recognition tests. RESULTS: All subjects successfully used the portable application with their clinical speech processors to experience different FATs while listening to running speech. The users were all able to select one table that they judged provided the best sound quality. All subjects chose a FAT different from the standard FAT in their everyday clinical processor. Using the smartphone application, the mean consonant-nucleus-consonant score with the default FAT selection was 28.5% (SD 16.8) and 29.5% (SD 16.4) when using a self-selected FAT. CONCLUSION: A portable smartphone application enables CI users to self-select frequency allocation tables in real time. Even though the self-selected FATs that were deemed to have better sound quality were only tested acutely (i.e., without long-term experience with them), speech perception scores were not inferior to those obtained with the clinical FATs. This software application may be a valuable tool for improving future methods of CI fitting.
PMCID:5556943
PMID: 28806335
ISSN: 1537-4505
CID: 2669212
Enhancing Intervention for Residual Rhotic Errors Via App-Delivered Biofeedback: A Case Study
Byun, Tara McAllister; Campbell, Heather; Carey, Helen; Liang, Wendy; Park, Tae Hong; Svirsky, Mario
Purpose: Recent research suggests that visual-acoustic biofeedback can be an effective treatment for residual speech errors, but adoption remains limited due to barriers including high cost and lack of familiarity with the technology. This case study reports results from the first participant to complete a course of visual-acoustic biofeedback using a not-for-profit iOS app, Speech Therapist's App for /r/ Treatment. Method: App-based biofeedback treatment for rhotic misarticulation was provided in weekly 30-min sessions for 20 weeks. Within-treatment progress was documented using clinician perceptual ratings and acoustic measures. Generalization gains were assessed using acoustic measures of word probes elicited during baseline, treatment, and maintenance sessions. Results: Both clinician ratings and acoustic measures indicated that the participant significantly improved her rhotic production accuracy in trials elicited during treatment sessions. However, these gains did not transfer to generalization probes. Conclusions: This study provides a proof-of-concept demonstration that app-based biofeedback is a viable alternative to costlier dedicated systems. Generalization of gains to contexts without biofeedback remains a challenge that requires further study. App-delivered biofeedback could enable clinician-research partnerships that would strengthen the evidence base while providing enhanced treatment for children with residual rhotic errors. Supplemental Material: https://doi.org/10.23641/asha.5116318.
PMCID:5544407
PMID: 28655050
ISSN: 1558-9102
CID: 2613622
Self-Selection of Frequency Tables with Bilateral Mismatches in an Acoustic Simulation of a Cochlear Implant
Fitzgerald, Matthew B; Prosolovich, Ksenia; Tan, Chin-Tuan; Glassman, E Katelyn; Svirsky, Mario A
BACKGROUND: Many recipients of bilateral cochlear implants (CIs) may have differences in electrode insertion depth. Previous reports indicate that when a bilateral mismatch is imposed, performance on tests of speech understanding or sound localization becomes worse. If recipients of bilateral CIs cannot adjust to a difference in insertion depth, adjustments to the frequency table may be necessary to maximize bilateral performance. PURPOSE: The purpose of this study was to examine the feasibility of using real-time manipulations of the frequency table to offset any decrements in performance resulting from a bilateral mismatch. RESEARCH DESIGN: A simulation of a CI was used because it allows for explicit control of the size of a bilateral mismatch. Such control is not available with users of CIs. STUDY SAMPLE: A total of 31 normal-hearing young adults participated in this study. DATA COLLECTION AND ANALYSIS: Using a CI simulation, four bilateral mismatch conditions (0, 0.75, 1.5, and 3 mm) were created. In the left ear, the analysis filters and noise bands of the CI simulation were the same. In the right ear, the noise bands were shifted higher in frequency to simulate a bilateral mismatch. Then, listeners selected a frequency table in the right ear that was perceived as maximizing bilateral speech intelligibility. Word-recognition scores were then assessed for each bilateral mismatch condition. Listeners were tested with both a standard frequency table, which preserved a bilateral mismatch, or with their self-selected frequency table. RESULTS: Consistent with previous reports, bilateral mismatches of 1.5 and 3 mm yielded decrements in word recognition when the standard table was used in both ears. However, when listeners used the self-selected frequency table, performance was the same regardless of the size of the bilateral mismatch. CONCLUSIONS: Self-selection of a frequency table appears to be a feasible method for ameliorating the negative effects of a bilateral mismatch. These data may have implications for recipients of bilateral CIs who cannot adapt to a bilateral mismatch, because they suggest that (1) such individuals may benefit from modification of the frequency table in one ear and (2) self-selection of a "most intelligible" frequency table may be a useful tool for determining how the frequency table should be altered to optimize speech recognition.
PMCID:5563263
PMID: 28534729
ISSN: 2157-3107
CID: 2574732
Self-Reported Usage, Functional Benefit, and Audiologic Characteristics of Cochlear Implant Patients Who Use a Contralateral Hearing Aid
Neuman, Arlene C; Waltzman, Susan B; Shapiro, William H; Neukam, Jonathan D; Zeman, Annette M; Svirsky, Mario A
Ninety-four unilateral CI patients with bimodal listening experience (CI plus HA in contralateral ear) completed a questionnaire that focused on attitudes toward hearing aid use postimplantation, patterns of usage, and perceived bimodal benefits in daily life. Eighty participants continued HA use and 14 discontinued HA use at the time of the questionnaire. Participant responses provided useful information for counseling patients both before and after implantation. The majority of continuing bimodal (CI plus HA) participants reported adapting to using both devices within 3 months and also reported that they heard better bimodally in quiet, noisy, and reverberant conditions. They also perceived benefits including improved sound quality, better music enjoyment, and sometimes a perceived sense of acoustic balance. Those who discontinued HA use found either that using the HA did not provide additional benefit over the CI alone or that using the HA degraded the signal from the CI. Because there was considerable overlap in the audiograms and in speech recognition performance in the unimplanted ear between the two groups, we recommend that unilateral CI recipients are counseled to continue to use the HA in the contralateral ear postimplantation in order to determine whether or not they receive functional or perceived benefit from using both devices together.
PMCID:5435367
PMID: 28351216
ISSN: 2331-2165
CID: 2508302