Try a new search

Format these results:

Searched for:

person:rosena23

Total Results:

527


Dynamic contrast-enhanced MRI of the prostate with high spatiotemporal resolution using compressed sensing, parallel imaging, and continuous golden-angle radial sampling: Preliminary experience

Rosenkrantz, Andrew B; Geppert, Christian; Grimm, Robert; Block, Tobias K; Glielmi, Christian; Feng, Li; Otazo, Ricardo; Ream, Justi M; Romolo, Melanie Moccaldi; Taneja, Samir S; Sodickson, Daniel K; Chandarana, Hersh
PURPOSE: To demonstrate dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate with both high spatial and temporal resolution via a combination of golden-angle radial k-space sampling, compressed sensing, and parallel-imaging reconstruction (GRASP), and to compare image quality and lesion depiction between GRASP and conventional DCE in prostate cancer patients. MATERIALS AND METHODS: Twenty prostate cancer patients underwent two 3T prostate MRI examinations on separate dates, one using standard DCE (spatial resolution 3.0 x 1.9 x 1.9 mm, temporal resolution 5.5 sec) and the other using GRASP (spatial resolution 3.0 x 1.1 x 1.1 mm, temporal resolution 2.3 sec). Two radiologists assessed measures of image quality and dominant lesion size. The experienced reader recorded differences in contrast arrival times between the dominant lesion and benign prostate. RESULTS: Compared with standard DCE, GRASP demonstrated significantly better clarity of the capsule, peripheral/transition zone boundary, urethra, and periprostatic vessels; image sharpness; and lesion conspicuity for both readers (P < 0.001-0.020). GRASP showed improved interreader correlation for lesion size (GRASP: r = 0.691-0.824, standard: r = 0.495-0.542). In 8/20 cases, only GRASP showed earlier contrast arrival in tumor than benign; in no case did only standard DCE show earlier contrast arrival in tumor. CONCLUSION: High spatiotemporal resolution prostate DCE is possible with GRASP, which has the potential to improve image quality and lesion depiction as compared with standard DCE.J. Magn. Reson. Imaging 2014. (c) 2014 Wiley Periodicals, Inc.
PMCID:4233205
PMID: 24833417
ISSN: 1053-1807
CID: 996522

Important nonurgent imaging findings: use of a hybrid digital and administrative support tool for facilitating clinician communication

Johnson, Evan; Sanger, Joseph; Rosenkrantz, Andrew B
A departmental tool that provides a digital/administrative solution for communication of important imaging findings was evaluated. The tool allows the radiologist to click a button to mark an examination for ordering physician follow-up with subsequent fax and confirmation. The tool's log was reviewed. Of 466 entries; 99.4% were successfully faxed with phone confirmation. Most common reasons for usage were lung nodule/mass (29.2%) and osseous fracture (12.4%). Subsequent clinical action was documented in 41.0% of entries. Our data show the reliability of the tool in assisting the communication of findings, as well as providing documentation of notification, with minimal workflow disruption.
PMID: 25636525
ISSN: 0899-7071
CID: 1448022

Magnetic Resonance Sentinel Lymph Node Detection in Prostate Cancer: A New Solution to a Longstanding Problem?

Rosenkrantz, Andrew B; Taneja, Samir S
PMID: 25797301
ISSN: 1878-4046
CID: 1513762

Advances in T1-Weighted and T2-Weighted Imaging in the Abdomen and Pelvis

Ream, Justin M; Rosenkrantz, Andrew B
Utilization of abdominopelvic MR imaging continues to increase in volume and gain widespread clinical acceptance. Many factors such as diaphragmatic respiratory motion, bulk patient motion, and the need for large volumetric coverage while maintaining clinically feasible scan times have proven challenging for body applications of MRI. However, many advances in MR acquisition, including non-Cartesian T1-weighted and T2-weighted acquisitions, advanced Dixon sequences, and 3-dimensional volumetric T2-weighted imaging have helped to mitigate some of the issues which have hampered abdominopelvic MR. This article will summarize these advances in T1-weighted and T2-weighted imaging, with an emphasis on clinical applications and implementation.
PMID: 25953291
ISSN: 1557-8275
CID: 1569652

Quantitative Graphical Analysis of Simultaneous Dynamic PET/MRI For Assessment of Prostate Cancer

Rosenkrantz, Andrew B; Koesters, Thomas; Vahle, Anne-Kristin; Friedman, Kent; Bartlett, Rachel M; Taneja, Samir S; Ding, Yu-Shin; Logan, Jean
PURPOSE: Dynamic FDG imaging for prostate cancer characterization is limited by generally small size and low uptake in prostate tumors. Our aim in this pilot study was to explore feasibility of simultaneous PET/MRI to guide localization of prostate lesions for dynamic FDG analysis using a graphical approach. METHODS: Three patients with biopsy-proven prostate cancer underwent simultaneous FDG PET/MRI, incorporating dynamic prostate imaging. Histology and multiparametric MRI findings were used to localize tumors, which in turn guided identification of tumors on FDG images. Regions of interest were manually placed on tumor and benign prostate tissue. Blood activity was extracted from a region of interest placed on the femoral artery on PET images. FDG data were analyzed by graphical analysis using the influx constant Ki (Patlak analysis) when FDG binding seemed irreversible and distribution volume VT (reversible graphical analysis) when FDG binding seemed reversible given the presence of washout. RESULTS: Given inherent coregistration, simultaneous acquisition facilitated use of MRI data to localize small lesions on PET and subsequent graphical analysis in all cases. In 2 cases with irreversible binding, tumor had higher Ki than benign using Patlak analysis (0.023 vs 0.006 and 0.019 vs 0.008 mL/cm per minute). In 1 case appearing reversible, tumor had higher VT than benign using reversible graphical analysis (0.68 vs 0.52 mL/cm). CONCLUSIONS: Simultaneous PET/MRI allows localization of small prostate tumors for dynamic PET analysis. By taking advantage of inclusion of the femoral arteries in the FOV, we applied advanced PET data analysis methods beyond conventional static measures and without blood sampling.
PMCID:4352122
PMID: 25608166
ISSN: 0363-9762
CID: 1440332

Continued evolution of clinical decision support tools for guiding imaging utilization [Letter]

Rosenkrantz, Andrew B; Doshi, Ankur M
PMID: 25753596
ISSN: 1076-6332
CID: 1494702

Prostate cancer: top places where tumors hide on multiparametric MRI

Rosenkrantz, Andrew B; Verma, Sadhna; Turkbey, Baris
OBJECTIVE: Prostate tumors occasionally have unusual manifestations on multiparametric MR images that can present a diagnostic dilemma and result in a false-negative interpretation. This article presents examples of such "hiding places" of prostate tumors, four in the peripheral zone and four in the central gland. CONCLUSION: The provided pointers in multiparametric MRI assessment can aid the radiologist in achieving an accurate diagnosis of tumor in the eight scenarios described.
PMID: 25794094
ISSN: 0361-803x
CID: 1506552

Whole-lesion apparent diffusion coefficient metrics as a marker of percentage Gleason 4 component within Gleason 7 prostate cancer at radical prostatectomy

Rosenkrantz, Andrew B; Triolo, Michael J; Melamed, Jonathan; Rusinek, Henry; Taneja, Samir S; Deng, Fang-Ming
PURPOSE: To retrospectively assess the utility of whole-lesion apparent diffusion coefficient (ADC) metrics in characterizing the Gleason 4 component of Gleason 7 prostate cancer (PCa) at radical prostatectomy. MATERIALS AND METHODS: Seventy patients underwent phased-array coil 3T-magnetic resonance imaging (MRI) before prostatectomy. A uropathologist mapped locations and Gleason 4 percentage (G4%) of Gleason 7 tumors. Two radiologists independently reviewed ADC maps, aware of tumor locations but not G4%, and placed a volume-of-interest (VOI) on all slices including each lesion on the ADC map to obtain whole-lesion mean ADC and ADC entropy. Entropy reflects textural variation and increases with greater macroscopic heterogeneity. Performance for characterizing Gleason 7 tumors was assessed with mixed-model analysis of variance (ANOVA) and logistic regression. RESULTS: Among 84 Gleason 7 tumors (G4% 5%-85%, median 30%; 59 Gleason 3+4, 25 Gleason 4+3), ADC entropy was significantly higher in Gleason 4+3 than Gleason 3+4 tumors (R1: 5.27 +/- 0.61 vs. 4.62 +/- 0.78, P = 0.001; R2: 5.91 +/- 0.32 vs. 5.57 +/- 0.56, P = 0.004); mean ADC was not significantly different between these groups (R1: 0.90 +/- 0.15*10-3 cm2 /s vs. 0.98 +/- 0.21*10-3 cm2 /s, P = 0.075; R2: 1.06 +/- 0.19*10-3 cm2 /s vs. 1.14 +/- 0.16*10-3 cm2 /s, P = 0.083). The area under the receiver operating characteristic (ROC) curve (AUC) for differentiating groups was significantly higher with ADC entropy than mean ADC for one observer (R1: 0.74 vs. 0.57, P = 0.027; R2: 0.69 vs. 0.61, P = 0.329). For R1, correlation with G4% was moderate for ADC entropy (r = 0.45) and weak for mean ADC (r = -0.25). For R2, correlation with G4% was moderate for ADC entropy (r = 0.41) and mean ADC (r = -0.32). For both readers, ADC entropy (P = 0.028-0.003), but not mean ADC (P = 0.384-0.854), was a significant independent predictor of G4%. CONCLUSION: Whole-lesion ADC entropy outperformed mean ADC in characterizing Gleason 7 tumors and may help refine prognosis for this heterogeneous PCa subset. J. Magn. Reson. Imaging 2014. (c) 2014 Wiley Periodicals, Inc.
PMCID:4696491
PMID: 24616064
ISSN: 1053-1807
CID: 918092

T2-weighted imaging of the prostate: Impact of the BLADE technique on image quality and tumor assessment

Rosenkrantz, Andrew B; Bennett, Genevieve L; Doshi, Ankur; Deng, Fang-Ming; Babb, James S; Taneja, Samir S
PURPOSE: To retrospectively compare standard and BLADE T2-weighted imaging (T2WI) sequences of the prostate in terms of image quality and tumor assessment. METHODS: 49 prostate cancer patients (64 +/- 6 years) who underwent 3 T phased-array coil MRI before prostatectomy were included. T2WI was acquired using standard rectilinear and BLADE techniques. Two readers (R1, R2) independently localized the dominant lesion using T2WI alone and using multi-parametric imaging; recorded presence of extraprostatic extension (EPE) in each lobe; and scored lesion conspicuity and absence of motion artifact (1-5 scale; 5 = highest quality). A third reader, unblinded to pathology, placed ROIs to record tumor-to-peripheral-zone contrast. Standard and BLADE T2WI were compared using paired Wilcoxon tests. RESULTS: BLADE showed a trend toward improved motion artifact for R1 (3.4 +/- 1.3 vs. 2.9 +/- 1.5; p = 0.054) but not R2 (4.0 +/- 1.0 vs. 3.9 +/- 1.1; p = 0.880). Dominant lesions showed significantly lower conspicuity using BLADE for R1 (2.8 +/- 2.0 vs. 3.2 +/- 2.0; p = 0.011) but not R2 (2.3 +/- 1.6 vs. 2.4 +/- 1.7; p = 0.353), and significantly lower tumor-to-peripheral-zone contrast using BLADE (0.35 +/- 0.13 vs. 0.42 +/- 0.15; p
PMID: 25156471
ISSN: 0942-8925
CID: 1162262

Association between changes in suspicious prostate lesions on serial MRI examinations and follow-up biopsy results

Rosenkrantz, Andrew B; Rice, Samuel L; Wehrli, Natasha E; Deng, Fang-Ming; Taneja, Samir S
We assessed changes in prostate lesions on serial magnetic resonance imaging (MRI) examinations in predicting biopsy results. Fifty-five men undergoing two prostate MRI examinations >/=6months apart, followed by targeted biopsy, were included. Two radiologists assessed dominant lesions for an increase in size or suspicion score. Progression on MRI had lower sensitivity (23.5%-35.3%) and higher specificity (76.2%-90.5%) than prostate-specific antigen (PSA) velocity (sensitivity 70.6%, specificity 52.4%) for predicting positive biopsy. Highest accuracy was achieved by PSA velocity (63.6%) for positive biopsy, and by MRI (65.5%-72.7%) for Gleason >6 tumor. Findings support lesion progression on MRI serving as a basis for performing subsequent targeted biopsy.
PMID: 25457528
ISSN: 0899-7071
CID: 1370712