Searched for: person:svirsm01 or azadpm01 or sagie01 or Nicole Capach (capacn01)
Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array
Svrakic, Maja; Roland, J Thomas Jr; McMenomey, Sean O; Svirsky, Mario A
OBJECTIVE: To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE). STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: Sixty-three MSE implants in pediatric and adult patients were compared with age- and sex-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. INTERVENTION: Cochlear implantation with either the AB 1j electrode or the AB MSE. MAIN OUTCOME MEASURES: The MSE and 1j electrodes were compared in their angular depth of insertion and pre to postoperative change in hearing thresholds. Hearing preservation was analyzed as a function of angular depth of insertion. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. RESULTS: Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2000 Hz were 10, 7, 2, and 6 dB smaller for the MSE electrode than for the 1j (p < 0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. CONCLUSION: The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect.
PMCID:5104204
PMID: 27755356
ISSN: 1537-4505
CID: 2279922
Enhancing speech envelope by integrating hair-cell adaptation into cochlear implant processing
Azadpour, Mahan; Smith, Robert L
Cochlear implants (CIs) bypass some of the mechanisms that underlie normal neural behavior as occurs in acoustic hearing. One such neural mechanism is short-term adaptation, which has been proposed to have a significant role in speech perception. Acoustically-evoked neural adaptation has been mainly attributed to the depletion of neurotransmitter in the hair-cell to auditory-nerve synapse and is therefore not fully present in CI stimulation. This study evaluated a signal processing method that integrated a physiological model of hair-cell adaptation into CI speech processing. The linear high-pass adaptation process expanded the range of rapid variations of the electrical signal generated by the clinical processing strategy. Speech perception performance with the adaptation-based processing was compared to that of the clinical strategy in seven CI users. While there was large variability across subjects, the new processing improved sentence recognition and consonant identification scores in quiet in all the tested subjects with an average improvement of 8% and 6% respectively. Consonant recognition scores in babble noise were improved at the higher signal-to-noise ratios tested (10 and 6 dB) only. Information transfer analysis of consonant features showed significant improvements for manner and place of articulation features, but not for voicing. Enhancement of within-channel envelope cues was confirmed by consonant recognition results obtained with single-channel strategies that presented the overall amplitude envelope of the signal on a single active electrode. Adaptation-inspired envelope enhancement techniques can potentially improve perception of important speech features by CI users.
PMID: 27697486
ISSN: 1878-5891
CID: 2386102
A physiological and behavioral system for hearing restoration with cochlear implants
King, Julia; Shehu, Ina; Roland, J Thomas Jr; Svirsky, Mario A; Froemke, Robert C
Cochlear implants are neuroprosthetic devices that provide hearing to deaf patients, although outcomes are highly variable even with prolonged training and use. The central auditory system must process cochlear implant signals, but it is unclear how neural circuits adapt - or fail to adapt - to such inputs. Understanding these mechanisms is required for development of next-generation neuroprosthetics that interface with existing neural circuits and enable synaptic plasticity to improve perceptual outcomes. Here we describe a new system for cochlear implant insertion, stimulation, and behavioral training in rats. Animals were first ensured to have significant hearing loss via physiological and behavioral criteria. We developed a surgical approach for multi-channel (2-channel or 8-channel) array insertion, comparable to implantation procedures and depth in humans. Peripheral and cortical responses to stimulation were used to objectively program the implant. Animals fitted with implants learned to use them for an auditory-dependent task that assesses frequency detection and recognition, in a background of environmentally- and self-generated noise, and ceased responding appropriately to sounds when the implant was temporarily inactivated. This physiologically-calibrated and behaviorally-validated system provides a powerful opportunity to study the neural basis of neuroprosthetic device use and plasticity.
PMCID:4995281
PMID: 27281743
ISSN: 1522-1598
CID: 2136552
Functional Segregation of Cortical Regions Underlying Speech Timing and Articulation
Long, Michael A; Katlowitz, Kalman A; Svirsky, Mario A; Clary, Rachel C; Byun, Tara McAllister; Majaj, Najib; Oya, Hiroyuki; Howard, Matthew A 3rd; Greenlee, Jeremy D W
Spoken language is a central part of our everyday lives, but the precise roles that individual cortical regions play in the production of speech are often poorly understood. To address this issue, we focally lowered the temperature of distinct cortical regions in awake neurosurgical patients, and we relate this perturbation to changes in produced speech sequences. Using this method, we confirm that speech is highly lateralized, with the vast majority of behavioral effects seen on the left hemisphere. We then use this approach to demonstrate a clear functional dissociation between nearby cortical speech sites. Focal cooling of pars triangularis/pars opercularis (Broca's region) and the ventral portion of the precentral gyrus (speech motor cortex) resulted in the manipulation of speech timing and articulation, respectively. Our results support a class of models that have proposed distinct processing centers underlying motor sequencing and execution for speech.
PMCID:4833207
PMID: 26924439
ISSN: 1097-4199
CID: 2009232
Information Theoretic Evaluation of a Noiseband-Based Cochlear Implant Simulator
Aguiar, Daniel E; Taylor, N Ellen; Li, Jing; Gazanfari, Daniel K; Talavage, Thomas M; Laflen, J Brandon; Neuberger, Heidi; Svirsky, Mario A
Noise-band vocoders are often used to simulate the signal processing algorithms used in cochlear implants (CIs), producing acoustic stimuli that may be presented to normal hearing (NH) subjects. Such evaluations may obviate the heterogeneity of CI user populations, achieving greater experimental control than when testing on CI subjects. However, it remains an open question whether advancements in algorithms developed on NH subjects using a simulator will necessarily improve performance in CI users. This study assessed the similarity in vowel identification of CI subjects and NH subjects using an 8-channel noise-band vocoder simulator configured to match input and output frequencies or to mimic output after a basalward shift of input frequencies. Under each stimulus condition, NH subjects performed the task both with and without feedback/training. Similarity of NH subjects to CI users was evaluated using correct identification rates and information theoretic approaches. Feedback/training produced higher rates of correct identification, as expected, but also resulted in error patterns that were closer to those of the CI users. Further evaluation remains necessary to determine how patterns of confusion at the token level are affected by the various parameters in CI simulators, providing insight into how a true CI simulation may be developed to facilitate more rapid prototyping and testing of novel CI signal processing and electrical stimulation strategies.
PMCID:4798893
PMID: 26409068
ISSN: 1878-5891
CID: 1787122
The neural encoding of formant frequencies contributing to vowel identification in normal-hearing listeners
Won, Jong Ho; Tremblay, Kelly; Clinard, Christopher G; Wright, Richard A; Sagi, Elad; Svirsky, Mario
Even though speech signals trigger coding in the cochlea to convey speech information to the central auditory structures, little is known about the neural mechanisms involved in such processes. The purpose of this study was to understand the encoding of formant cues and how it relates to vowel recognition in listeners. Neural representations of formants may differ across listeners; however, it was hypothesized that neural patterns could still predict vowel recognition. To test the hypothesis, the frequency-following response (FFR) and vowel recognition were obtained from 38 normal-hearing listeners using four different vowels, allowing direct comparisons between behavioral and neural data in the same individuals. FFR was employed because it provides an objective and physiological measure of neural activity that can reflect formant encoding. A mathematical model was used to describe vowel confusion patterns based on the neural responses to vowel formant cues. The major findings were (1) there were large variations in the accuracy of vowel formant encoding across listeners as indexed by the FFR, (2) these variations were systematically related to vowel recognition performance, and (3) the mathematical model of vowel identification was successful in predicting good vs poor vowel identification performers based exclusively on physiological data.
PMCID:4706540
PMID: 26826999
ISSN: 1520-8524
CID: 1931872
Measurement of Cochlear Implant Electrode Position From Intraoperative Post-insertion Skull Radiographs: A Validation Study
Svrakic, Maja; Friedmann, David R; Berman, Phillip M; Davis, Adam J; Roland, J Thomas Jr; Svirsky, Mario A
OBJECTIVE: To validate a method of measuring angular depth of insertion (aDOI) as well as positional depth of each electrode contact in a cochlear implant by using intraoperative postinsertion skull radiographs. STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: Intraoperative postinsertion radiographs obtained from 18 cochlear implant recipients were chosen for analysis. One high-resolution computer tomography scan of the head with the electrode in place was also analyzed. One cadaveric temporal bone with an inserted electrode provided additional data for analysis. INTERVENTION: aDOI and position of each electrode contact were measured from the radiographs using readily available software. High-resolution computer tomography imaging of the cochlea and electrode were reconstructed in three dimensions and used to simulate head rotation during intraoperative radiographs. The cadaveric temporal bone was imaged by x-ray at various acquisition angles. MAIN OUTCOME MEASURES: We evaluated the error introduced in measuring aDOI by assessing intra- and inter-rater variability. We also evaluated the error introduced by x-ray acquisition at nonstandardized angles by analyzing the three-dimensional construct and the cadaveric temporal bone. RESULTS: The concordance correlation coefficients for intrarater (0.991) and inter-rater (0.996) variability in aDOI measurement were excellent. The error introduced by nonstandardized x-ray acquisition angles was only -12.5 degrees to +15.8 degrees even at the limits of clinically relevant head rotation. CONCLUSIONS: The intraoperative postinsertion radiograph is sufficient for estimating positional depth of electrode contacts and the aDOI. This measure is robust in the face of nonstandardized x-ray acquisition angles, and shows good intra- and inter-rater variability.
PMCID:4574306
PMID: 26375970
ISSN: 1537-4505
CID: 1778232
The Relationship Between Insertion Angles, Default Frequency Allocations, and Spiral Ganglion Place Pitch in Cochlear Implants
Landsberger, David M; Svrakic, Maja; Roland, J Thomas Jr; Svirsky, Mario
OBJECTIVES: Commercially available cochlear implant systems attempt to deliver frequency information going down to a few hundred Hertz, but the electrode arrays are not designed to reach the most apical regions of the cochlea, which correspond to these low frequencies. This may cause a mismatch between the frequencies presented by a cochlear implant electrode array and the frequencies represented at the corresponding location in a normal-hearing cochlea. In the following study, the mismatch between the frequency presented at a given cochlear angle and the frequency expected by an acoustic hearing ear at the corresponding angle is examined for the cochlear implant systems that are most commonly used in the United States. DESIGN: The angular insertion of each of the electrodes on four different electrode arrays (MED-EL Standard, MED-EL Flex28, Advanced Bionics HiFocus 1J, and Cochlear Contour Advance) was estimated from X-ray. For the angular location of each electrode on each electrode array, the predicted spiral ganglion frequency was estimated. The predicted spiral ganglion frequency was compared with the center frequency provided by the corresponding electrode using the manufacturer's default frequency-to-electrode allocation. RESULTS: Differences across devices were observed for the place of stimulation for frequencies below 650 Hz. Longer electrode arrays (i.e., the MED-EL Standard and Flex28) demonstrated smaller deviations from the spiral ganglion map than the other electrode arrays. For insertion angles up to approximately 270 degrees , the frequencies presented at a given location were typically approximately an octave below what would be expected by a spiral ganglion frequency map, while the deviations were larger for angles deeper than 270 degrees . For frequencies above 650 Hz, the frequency to angle relationship was consistent across all four electrode models. CONCLUSIONS: A mismatch was observed between the predicted frequency and the default frequency provided by every electrode on all electrode arrays. The mismatch can be reduced by changing the default frequency allocations, inserting electrodes deeper into the cochlea, or allowing cochlear implant users to adapt to the mismatch. Further studies are required to fully assess the clinical significance of the frequency mismatch.
PMCID:4549170
PMID: 25860624
ISSN: 1538-4667
CID: 1742442
A proposed mechanism for rapid adaptation to spectrally distorted speech
Azadpour, Mahan; Balaban, Evan
The mechanisms underlying perceptual adaptation to severely spectrally-distorted speech were studied by training participants to comprehend spectrally-rotated speech, which is obtained by inverting the speech spectrum. Spectral-rotation produces severe distortion confined to the spectral domain while preserving temporal trajectories. During five 1-hour training sessions, pairs of participants attempted to extract spoken messages from the spectrally-rotated speech of their training partner. Data on training-induced changes in comprehension of spectrally-rotated sentences and identification/discrimination of spectrally-rotated phonemes were used to evaluate the plausibility of three different classes of underlying perceptual mechanisms: (1) phonemic remapping (the formation of new phonemic categories that specifically incorporate spectrally-rotated acoustic information); (2) experience-dependent generation of a perceptual "inverse-transform" that compensates for spectral-rotation; and (3) changes in cue weighting (the identification of sets of acoustic cues least affected by spectral-rotation, followed by a rapid shift in perceptual emphasis to favour those cues, combined with the recruitment of the same type of "perceptual filling-in" mechanisms used to disambiguate speech-in-noise). Results exclusively support the third mechanism, which is the only one predicting that learning would specifically target temporally-dynamic cues that were transmitting phonetic information most stably in spite of spectral-distortion. No support was found for phonemic remapping or for inverse-transform generation.
PMID: 26233005
ISSN: 1520-8524
CID: 2689882
Electrode Selection and Speech Understanding in Patients With Auditory Brainstem Implants
McKay, Colette M; Azadpour, Mahan; Jayewardene-Aston, Deanne; O'Driscoll, Martin; El-Deredy, Wael
OBJECTIVES: The objective of this study was to evaluate whether speech understanding in auditory brainstem implant (ABI) users who have a tumor pathology could be improved by the selection of a subset of electrodes that were appropriately pitch ranked and distinguishable. It was hypothesized that disordered pitch or spectral percepts and channel interactions may contribute significantly to the poor outcomes in most ABI users. DESIGN: A single-subject design was used with five participants. Pitch ranking information for all electrodes in the patients' clinic maps was obtained using a pitch ranking task and previous pitch ranking information from clinic sessions. A multidimensional scaling task was used to evaluate the stimulus space evoked by stimuli on the same set of electrodes. From this information, a subset of four to six electrodes was chosen and a new map was created, using just this subset, that the subjects took home for 1 month's experience. Closed-set consonant and vowel perception and sentences in quiet were tested at three sessions: with the clinic map before the test map was given, after 1 month with the test map, and after an additional 2 weeks with their clinic map. RESULTS: The results of the pitch ranking and multidimensional scaling procedures confirmed that the ABI users did not have a well-ordered set of percepts related to electrode position, thus supporting the proposal that difficulty in processing of spectral information may contribute to poor speech understanding. However, none of the subjects benefited from a map that reduced the stimulation electrode set to a smaller number of electrodes that were well ordered in place pitch. CONCLUSIONS: Although poor spectral processing may contribute to poor understanding in ABI users, it is not likely to be the sole contributor to poor outcomes.
PMID: 25668392
ISSN: 1538-4667
CID: 2689892