Try a new search

Format these results:

Searched for:

person:bhatlp01

in-biosketch:true

Total Results:

49


PATIENT-SPECIFIC SIMULATION OF RIGHT VENTRICLE OUTFLOW TRACT CONDUIT BALLOON ANGIOPLASTY USING CARDIAC MRI-DERIVED 3D VIRTUAL MODELS TO ASSESS THE RISK OF CORONARY ARTERY COMPRESSION DURING TRANSCATHETER PULMONARY VALVE REPLACEMENT [Meeting Abstract]

Bhatla, Puneet; Chakravarti, Sujata; Ludomirsky, Achiau; Argilla, Michael; Berman, Phillip; McElhinney, Doff; Flamini, Vittoria
ISI:000375328800573
ISSN: 0735-1097
CID: 2962462

Comparison of Reported Outcomes With Percutaneous Versus Surgical Closure of Ruptured Sinus of Valsalva Aneurysm

Kuriakose, Emy M; Bhatla, Puneet; McElhinney, Doff B
Sinus of Valsalva aneurysm is a rare cardiac malformation that stems from incomplete fusion of the aortic media and the aortic valve annulus, a weakness that may result in rupture of the sinus, large left-to-right shunt, and severe congestive heart failure. Historically, this lesion has been repaired surgically, but percutaneous closure (PC) has emerged as a therapeutic intervention over the last 20 years. We review and contrast 34 studies detailing the PC approach with 16 studies on surgical closure (SC), together comprising a total of 877 patients who were treated for ruptured sinus of Valsalva aneurysm from 1956 to 2014. Both groups had similar sites of rupture, age distribution, and clinical symptoms at presentation. Selection bias ultimately prohibits a direct comparison between the 2 groups as patients who underwent SC often had worse aortic regurgitation and more complex associated lesions, including endocarditis, bicuspid aortic valve, tunnel-type fistulous connections, larger defect size, and multiple site of rupture. In conclusion, although SC is indicated and reserved for these more complicated patients, our review of previously published reports reveals that PC in patients who are too ill to undergo bypass, with mild or no aortic regurgitation and simple associated defects (muscular ventricular septal defects, secundum atrial septal defect, small patent ductus arteriosus), can be safe, effective, and practical.
PMID: 25488356
ISSN: 0002-9149
CID: 1433012

Use of the Aquadexâ„¢ system for ultrafiltration therapy in a hemodynamically unstable pediatric patient [Case Report]

Farrell, Meghan K; Bhatla, Puneet; Bull, Catherine; Mosca, Ralph S; Chakravarti, Sujata B
In this case report, we describe the use of the Aquadexâ„¢ system for ultrafiltration therapy in the pediatric cardiac intensive care setting in a patient with fluid overload and acute kidney injury after congenital heart surgery. The patient is an 11-year-old, 25 kg male with complex single ventricle anatomy who underwent a one and a half ventricle repair. The patient experienced multiple organ dysfunction syndrome including acute kidney injury in the early post-operative period secondary to low cardiac output syndrome and tachyarrhythmia. Ultrafiltration using the Aquadexâ„¢ system was utilized to treat fluid overload in the setting of acute kidney injury and hemodynamic instability. Negative fluid balance was safely achieved. It was subsequently possible to wean ventilatory and inotropic support. We conclude that the use of ultrafiltration therapy is feasible in hemodynamically unstable pediatric patients with significant fluid overload in the setting of acute kidney injury following congenital heart surgery.
PMCID:6530742
PMID: 31214453
ISSN: 2146-4618
CID: 3956162

Vascular ring in an infant with cystic fibrosis

Tetter, Justin T; Bhatla, Puneet; Chakravarti, Sujata
A vascular ring (VR) is a rare congenital anomaly that has variable clinical presentation, but may cause trachea-esophageal compressive symptoms. We describe an infant with cystic fibrosis and subtle trachea-esophageal compressive symptoms which were initially attributed to other causes, delaying the diagnosis of a VR
ORIGINAL:0009377
ISSN: 1927-1255
CID: 1431972

Cardiovascular magnetic resonance as an alternate method for serial evaluation of proximal aorta: comparison with echocardiography

Bhatla, Puneet; Nielsen, James C
Thoracic aortic disease is a known cause of aortic dilatation and poses significant risk of aortic dissection and rupture. Serial assessment of aortic root dimensions is traditionally performed using echocardiography, which is limited with older age and following surgery, due to poor acoustic windows. Although diastolic measurements are utilized as standard practice in decision making of adult aortopathy, systolic diameters are utilized in pediatric practice. Three-dimensional steady-state free precision (3D-SSFP) has shown promise as an alternate method for providing accurate and reproducible aortic measurements. The agreement between proximal aorta measurements by diastolic 3D-SSFP and echocardiography (both systole and diastole) was examined in 40 subjects. The maximum inner diameters at aortic annulus, root and sinotubular junction demonstrated excellent agreement between 3D-SSFP and echocardiography for all the 3 levels. The best agreement was observed for diastolic root dimensions with a mean difference of +0.01 cm, limits of agreement being -0.26 to +0.28 cm. Three D-SSFP can be used interchangeably with echocardiography in the serial assessment of the aortic root size. Careful attention to obtain an imaging plane utilizing 3D multiplanar reformatting is critical to maximize the agreement between the two imaging modalities.
PMID: 23311530
ISSN: 0742-2822
CID: 556342

Pulmonic valvar disease

Chapter by: Srivastava, Shubhika; Bhatla, Puneet
in: Perioperative transesophageal echocardiography : a companion to Kaplan's cardiac anesthesia by Reich, David L; Fischer, Gregory W [Eds]
Philadelphia PA : Elsevier Saunders, 2013
pp. 163-166
ISBN: 1455707619
CID: 556362

Normal values of left atrial volume in pediatric age group using a validated allometric model

Bhatla, Puneet; Nielsen, James C; Ko, Helen H; Doucette, John; Lytrivi, Irene D; Srivastava, Shubhika
BACKGROUND: Left atrial volume (LAV) increase is an indicator of diastolic dysfunction and a surrogate marker of significant left to right shunts. Normalization of LAV is currently performed by indexing to body surface area(1) (BSA(1)). The indexed LAV thus derived does not account for the nonlinear relationship of physiologic variables to BSA and has not been tested for independence to body size. Our objective was to identify a valid allometric model for indexing LAV and use it to develop Z-scores in children. METHODS AND RESULTS: LAV was measured in 300 normal subjects by echocardiography using the biplane area length method. LAV/BSA(1) had a residual relationship to BSA (r=0.52, P<0.0001). The allometric exponent (AE) derived for the entire cohort (1.27) using the least squares regression analysis also failed to eliminate the residual relationship to BSA (r=-0.15, P=0.01). Dividing the cohort in two groups with a BSA cut-off of 1 m(2) provided the best-fit allometric model. The AE for each group was 1.48 and 1.08 for BSA1 m(2), respectively, and was validated against an independent sample. The mean indexed LAV+/-SD for BSA1 m(2) is 31.5+/-5.5 mL and 26.0+/-4.2 mL, respectively, and was used to derive Z-scores. CONCLUSIONS: This study demonstrates the fallacy of using "per-BSA(1) standards" for normalization of LAV in pediatrics. LAV/BSA(1.48) for children with BSA1 m(2) is accurate and can be used to derive Z-scores.
PMID: 23074344
ISSN: 1941-9651
CID: 556352

Normal values for left ventricular volume in infants and young children by the echocardiographic subxiphoid five-sixth area by length (bullet) method

Lytrivi, Irene D; Bhatla, Puneet; Ko, H Helen; Yau, Jen; Geiger, Miwa K; Walsh, Rowan; Parness, Ira A; Srivastava, Shubhika; Nielsen, James C
BACKGROUND: Left ventricular (LV) end-diastolic volume (LVEDV) can be estimated by the formula (5/6) x area x length, or the "bullet" method. The aim of this study was to determine the range of normal LVEDV values in infants and young children (aged 0-3 years) by the subxiphoid bullet method. METHODS: Echocardiograms from 100 normal subjects aged
PMID: 21281912
ISSN: 0894-7317
CID: 174704

The accuracy of echocardiographic assessment of left ventricular size in children by the 5/6 area x length (bullet) method

Nielsen, James C; Lytrivi, Irene D; Ko, H Helen; Yau, Jen; Bhatla, Puneet; Parness, Ira A; Srivastava, Shubhika
INTRODUCTION: Left ventricular end-diastolic volume (LVEDV) calculation is important in decision making in children with congenital heart disease (CHD). This study examined the accuracy of LVEDV calculation by the formula: 5/6 x area x length ("bullet" method), by comparing echocardiographic (ECHO) LVEDV against cardiac magnetic resonance (CMR). METHODS: ECHO and CMR data from 72 consecutive subjects with CHD < or =10 years of age were retrospectively reviewed. Exclusion criteria included: >3 months between examinations; unavailable or poor-quality images. Subxiphoid short- and long-axis echocardiographic images were analyzed. Bullet LVEDV was compared to CMR volumes. RESULTS: Seventeen subjects (median age 5.5 years, range 1-10 years) comprised the study group. ECHO and CMR LVEDV showed an excellent correlation (r = 0.97) and a good agreement with a mean difference (limits of agreement) of -1.0 mL (-13.9 to 11.9 mL). CONCLUSIONS: Subxiphoid echocardiographic bullet method of measuring LVEDV shows a good agreement with CMR obtained LV size in young children.
PMID: 20412269
ISSN: 0742-2822
CID: 174705