Try a new search

Format these results:

Searched for:

person:ceradd01 or pc92 or leuchp01 or lup03 or ramkhb01 or itom02 or psr237 or wosczm01

active:yes

exclude-minors:true

Total Results:

803


Ultrathin lithium disilicate and translucent zirconia crowns for posterior teeth: Survival and failure modes

Benalcazar Jalkh, Ernesto B; Ramalho, Ilana S; Bergamo, Edmara T P; Alves, Larissa M M; Tanaka, Ricardo; Witek, Lukasz; Coelho, Paulo G; Hirata, Ronaldo; Bonfante, Estevam A
PURPOSE/OBJECTIVE:To evaluate the reliability and failure modes of ultrathin (0.5 mm) lithium disilicate, translucent and ultra-translucent zirconia crowns for posterior teeth restorations. MATERIALS AND METHODS/METHODS:Fifty-four mandibular first molar crowns of three ceramic materials: (1) Lithium disilicate (e.max CAD, Ivoclar Vivadent), (2) 3Y-TZP (Zirconn Translucent, Vipi), and (3) 5Y-PSZ (Cercon XT, Dentsply Sirona), with 0.5 mm of thickness were milled and cemented onto composite resin abutments. Eighteen samples of each group were tested under mouth-motion step-stress accelerated life testing in a humid environment using mild, moderate, and aggressive profiles. Data was subjected to Weibull statistics. Use level curves were plotted and reliability was calculated for a given mission of 100,000 cycles at 100, 200, and 300 N. Fractographic analyses of representative samples were performed in scanning electron microscope. RESULTS:Beta (β) values suggest that failures were dictated by material's strength for lithium disilicate and by fatigue damage accumulation for both zirconias. No significant differences were detected in Weibull modulus and characteristic strength among groups. At a given mission of 100,000 cycles at 100 N, lithium disilicate presented higher reliability (98% CB: 95-99) regarding 3Y-TZP and 5Y-PSZ groups (84% CB: 65%-93% and 79% CB: 37&-94%, respectively). At 200 N, lithium disilicate reliability (82% CB: 66%-91%) was higher than 5Y-PSZ (20% CB: 4%-44%) and not significantly different from 3Y-TZP (54% CB: 32%-72%). Furthermore, at 300 N no significant differences in reliability were detected among groups, with a notable reduction in the reliability of all materials. Fractographic analyses showed that crack initiated at the interface between the composite core and the ceramic crowns due to tensile stress generated at the intaglio surface. CONCLUSIONS:Ultrathin lithium disilicate crowns demonstrated higher reliability relative to zirconia crowns at functional loads. Lithium disilicate and zirconia crown's reliability decreased significantly for missions at higher loads and similar failure modes were observed regardless of crown material. The indication of 0.5 mm thickness crowns in high-load bearing regions must be carefully evaluated. CLINICAL SIGNIFICANCE/CONCLUSIONS:Ultraconservative lithium disilicate and zirconia crowns of 0.5 mm thickness may be indicated in anterior restorations and pre-molars. Their clinical indication in high-load requirement regions must be carefully evaluated.
PMID: 37676053
ISSN: 1708-8240
CID: 5625542

Bone Tissue Engineering (BTE) of the Craniofacial Skeleton, Part II: Translational Potential of 3D-Printed Scaffolds for Defect Repair

Slavin, Blaire V.; Nayak, Vasudev V.; Boczar, Daniel; Bergamo, Edmara T.P.; Slavin, Benjamin R.; Yarholar, Lauren M.; Torroni, Andrea; Coelho, Paulo G.; Witek, Lukasz
Computer-aided design/computer-aided manufacturing and 3-dimensional (3D) printing techniques have revolutionized the approach to bone tissue engineering for the repair of craniomaxillofacial skeletal defects. Ample research has been performed to gain a fundamental understanding of the optimal 3D-printed scaffold design and composition to facilitate appropriate bone formation and healing. Benchtop and preclinical, small animal model testing of 3D-printed bioactive ceramic scaffolds augmented with pharmacological/biological agents have yielded promising results given their potential combined osteogenic and osteoinductive capacity. However, other factors must be evaluated before newly developed constructs may be considered analogous alternatives to the "gold standard" autologous graft for defect repair. More specifically, the 3D-printed bioactive ceramic scaffold's long-term safety profile, biocompatibility, and resorption kinetics must be studied. The ultimate goal is to successfully regenerate bone that is comparable in volume, density, histologic composition, and mechanical strength to that of native bone. In vivo studies of these newly developed bone tissue engineering in translational animal models continue to make strides toward addressing regulatory and clinically relevant topics. These include the use of skeletally immature animal models to address the challenges posed by craniomaxillofacial defect repair in pediatric patients. This manuscript reviews the most recent preclinical animal studies seeking to assess 3D-printed ceramic scaffolds for improved repair of critical-sized craniofacial bony defects.
SCOPUS:85181516357
ISSN: 1049-2275
CID: 5630232

Surgical repair of large segmental bone loss with the induced membrane technique: patient reported outcomes are comparable to nonunions without bone loss

Konda, Sanjit R; Boadi, Blake I; Leucht, Philipp; Ganta, Abhishek; Egol, Kenneth A
OBJECTIVE:To compare the outcomes of patients with segmental bone loss who underwent repair with the induced membrane technique (IMT) with a matched cohort of nonunion fractures without bone loss. DESIGN/METHODS:Retrospective analysis on prospectively collected data. SETTING/METHODS:Academic medical center. PATIENTS/METHODS:Two cohorts of patients, those with upper and lower extremity diaphyseal large segmental bone loss and those with ununited fractures, were enrolled prospectively between 2013 and 2020. Sixteen patients who underwent repair of 17 extremities with segmental diaphyseal or meta-diaphyseal bone defects treated with the induced membrane technique were identified, and matched with 17 patients who were treated for 17 fracture nonunions treated without an induced membrane. Sixteen of the bone defects treated with the induced membrane technique were due to acute bone loss, and the other was a chronic aseptic nonunion. MAIN OUTCOME MEASUREMENTS/METHODS:Healing rate, time to union, functional outcome scores using the Short Musculoskeletal Functional Assessment (SMFA) and pain assessed by the Visual Analog Scale (VAS). RESULTS:The initial average defect size for patients treated with the induced membrane technique was 8.85 cm. Mean follow-up times were similar with 17.06 ± 10.13 months for patients treated with the IMT, and 20.35 ± 16.68. months for patients treated without the technique. Complete union was achieved in 15/17 (88.2%) of segmental bone loss cases treated with the IMT and 17/17 (100%) of cases repaired without the technique at the latest follow up visit. The average time to union for patients treated with the induced membrane technique was 13.0 ± 8.4 months and 9.64 ± 4.7 months for the matched cohort. There were no significant differences in reported outcomes measured by the SMFA or VAS. Patients treated with the induced membrane technique required more revision surgeries than those not treated with an induced membrane. CONCLUSION/CONCLUSIONS:Outcomes following treatment of acute bone loss from the diaphysis of long bones with the induced membrane technique produces clinical and radiographic outcomes similar to those of long bone fracture nonunions without bone loss that go on to heal. LEVEL OF EVIDENCE/METHODS:III.
PMID: 37439888
ISSN: 1432-1068
CID: 5537692

Nav1.7 as a chondrocyte regulator and therapeutic target for osteoarthritis

Fu, Wenyu; Vasylyev, Dmytro; Bi, Yufei; Zhang, Mingshuang; Sun, Guodong; Khleborodova, Asya; Huang, Guiwu; Zhao, Libo; Zhou, Renpeng; Li, Yonggang; Liu, Shujun; Cai, Xianyi; He, Wenjun; Cui, Min; Zhao, Xiangli; Hettinghouse, Aubryanna; Good, Julia; Kim, Ellen; Strauss, Eric; Leucht, Philipp; Schwarzkopf, Ran; Guo, Edward X; Samuels, Jonathan; Hu, Wenhuo; Attur, Mukundan; Waxman, Stephen G; Liu, Chuan-Ju
Osteoarthritis (OA) is the most common joint disease. Currently there are no effective methods that simultaneously prevent joint degeneration and reduce pain1. Although limited evidence suggests the existence of voltage-gated sodium channels (VGSCs) in chondrocytes2, their expression and function in chondrocytes and in OA remain essentially unknown. Here we identify Nav1.7 as an OA-associated VGSC and demonstrate that human OA chondrocytes express functional Nav1.7 channels, with a density of 0.1 to 0.15 channels per µm2 and 350 to 525 channels per cell. Serial genetic ablation of Nav1.7 in multiple mouse models demonstrates that Nav1.7 expressed in dorsal root ganglia neurons is involved in pain, whereas Nav1.7 in chondrocytes regulates OA progression. Pharmacological blockade of Nav1.7 with selective or clinically used pan-Nav channel blockers significantly ameliorates the progression of structural joint damage, and reduces OA pain behaviour. Mechanistically, Nav1.7 blockers regulate intracellular Ca2+ signalling and the chondrocyte secretome, which in turn affects chondrocyte biology and OA progression. Identification of Nav1.7 as a novel chondrocyte-expressed, OA-associated channel uncovers a dual target for the development of disease-modifying and non-opioid pain relief treatment for OA.
PMCID:10794151
PMID: 38172636
ISSN: 1476-4687
CID: 5626502

Bone Tissue Engineering (BTE) of the Craniofacial Skeleton, Part II: Translational Potential of 3D-Printed Scaffolds for Defect Repair

Slavin, Blaire V; Nayak, Vasudev V; Boczar, Daniel; Bergamo, Edmara Tp; Slavin, Benjamin R; Yarholar, Lauren M; Torroni, Andrea; Coelho, Paulo G; Witek, Lukasz
Computer-aided design/computer-aided manufacturing and 3-dimensional (3D) printing techniques have revolutionized the approach to bone tissue engineering for the repair of craniomaxillofacial skeletal defects. Ample research has been performed to gain a fundamental understanding of the optimal 3D-printed scaffold design and composition to facilitate appropriate bone formation and healing. Benchtop and preclinical, small animal model testing of 3D-printed bioactive ceramic scaffolds augmented with pharmacological/biological agents have yielded promising results given their potential combined osteogenic and osteoinductive capacity. However, other factors must be evaluated before newly developed constructs may be considered analogous alternatives to the "gold standard" autologous graft for defect repair. More specifically, the 3D-printed bioactive ceramic scaffold's long-term safety profile, biocompatibility, and resorption kinetics must be studied. The ultimate goal is to successfully regenerate bone that is comparable in volume, density, histologic composition, and mechanical strength to that of native bone. In vivo studies of these newly developed bone tissue engineering in translational animal models continue to make strides toward addressing regulatory and clinically relevant topics. These include the use of skeletally immature animal models to address the challenges posed by craniomaxillofacial defect repair in pediatric patients. This manuscript reviews the most recent preclinical animal studies seeking to assess 3D-printed ceramic scaffolds for improved repair of critical-sized craniofacial bony defects.
PMID: 37622526
ISSN: 1536-3732
CID: 5598722

Does Flipping from Prone to Supine for Medial Malleolar Fixation of Trimalleolar Ankle Fractures Improve Results?

Kadiyala, Manasa L; Merrell, Lauren A; Ganta, Abhishek; Konda, Sanjit R; Rivero, Steven M; Leucht, Philipp; Tejwani, Nirmal C; Egol, Kenneth A
There has been a paradigm shift towards fixing the posterior malleolus in trimalleolar ankle fractures. This study evaluated whether a surgeon's preference to intraoperatively flip or not flip patients from prone to supine for medial malleolar fixation following repair of fibular and posterior malleoli impacted surgical outcomes. A retrospective patient cohort treated at a large urban academic center and level 1 trauma center was reviewed to identify all operative trimalleolar ankle fractures initially positioned prone. One hundred and forty-seven patients with mean 12-month follow up were included and divided based on positioning for medial malleolar fixation, prone or supine (following closure, flip and re-prep and drape). Data was collected on patient demographics, injury mechanism, perioperative variables, and complication rates. Postoperative reduction films were reviewed by orthopedic traumatologists to grade the accuracy of anatomic fracture reduction. Overall, 74 (50.3%) had the medial malleolus fixed prone, while 73 (49.7%) were flipped and fixed supine. No differences in demographics, injury details, and fracture type existed between the groups. The supine group had a higher rate of initial external fixation (p=0.047), longer operative time in minutes (p<0.001), and a higher use of plate and screw constructs for medial malleolar fixation (p=0.019). There were no differences in clinical and radiographic outcomes and complication rates. This study demonstrated that intraoperative change in positioning for improved medial malleolar visualization in trimalleolar ankle fractures results in longer operative times but similar radiographic and clinical results. The decision of operative position should be based on surgeon comfort.
PMID: 38103721
ISSN: 1542-2224
CID: 5612532

3D Printing Applications for Craniomaxillofacial Reconstruction: A Sweeping Review

Slavin, Blaire V; Ehlen, Quinn T; Costello, Joseph P; Nayak, Vasudev Vivekanand; Bonfante, Estavam A; Benalcázar Jalkh, Ernesto B; Runyan, Christopher M; Witek, Lukasz; Coelho, Paulo G
The field of craniomaxillofacial (CMF) surgery is rich in pathological diversity and broad in the ages that it treats. Moreover, the CMF skeleton is a complex confluence of sensory organs and hard and soft tissue with load-bearing demands that can change within millimeters. Computer-aided design (CAD) and additive manufacturing (AM) create extraordinary opportunities to repair the infinite array of craniomaxillofacial defects that exist because of the aforementioned circumstances. 3D printed scaffolds have the potential to serve as a comparable if not superior alternative to the "gold standard" autologous graft. In vitro and in vivo studies continue to investigate the optimal 3D printed scaffold design and composition to foster bone regeneration that is suited to the unique biological and mechanical environment of each CMF defect. Furthermore, 3D printed fixation devices serve as a patient-specific alternative to those that are available off-the-shelf with an opportunity to reduce operative time and optimize fit. Similar benefits have been found to apply to 3D printed anatomical models and surgical guides for preoperative or intraoperative use. Creation and implementation of these devices requires extensive preclinical and clinical research, novel manufacturing capabilities, and strict regulatory oversight. Researchers, manufacturers, CMF surgeons, and the United States Food and Drug Administration (FDA) are working in tandem to further the development of such technology within their respective domains, all with a mutual goal to deliver safe, effective, cost-efficient, and patient-specific CMF care. This manuscript reviews FDA regulatory status, 3D printing techniques, biomaterials, and sterilization procedures suitable for 3D printed devices of the craniomaxillofacial skeleton. It also seeks to discuss recent clinical applications, economic feasibility, and future directions of this novel technology. By reviewing the current state of 3D printing in CMF surgery, we hope to gain a better understanding of its impact and in turn identify opportunities to further the development of patient-specific surgical care.
PMID: 37982644
ISSN: 2373-9878
CID: 5608172

Minimally processed recycled yttria-stabilized tetragonal zirconia for dental applications: Effect of sintering temperature on glass infiltration

Campos, Tiago Moreira Bastos; Dos Santos, Claudinei; Alves, Larissa Marcia Martins; Benalcazar-Jalkh, Ernesto B; Strazzi-Sahyon, Henrico Badaoui; Bergamo, Edmara T P; Tebcherani, Sérgio Mazurek; Witek, Lukasz; Coelho, Paulo G; Yamaguchi, Satoshi; Thim, Gilmar P; Bonfante, Estevam A
This study aimed to develop a recycling process for the remnants of milled 3Y-TZP and enhance their properties using glass infiltration. 3Y-TZP powder was gathered from the vacuum system of CAD-CAM milling equipment, calcined and sieved (x < 75 μm). One hundred twenty discs were fabricated and pre-sintered at 1000 °C/h. These specimens were then divided into four groups, categorized by glass infiltration (non-infiltrated [Zr] or glass-infiltrated [Zr-G]) and sintering temperature (1450 °C [Zr-1450] or 1550 °C [Zr-1550]/2h). After sintering, the specimens were characterized by X-Ray Diffraction (XRD), relative density measurement, and scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS). The biaxial flexural strength test was performed according to the ISO 6872 and followed by fractographic analysis. Subsequent results were analyzed using Weibull statistics. Relative density values of the sintered specimens from Zr-1450 and Zr-1550 groups were 86.7 ± 1.5% and 92.2 ± 1.7%, respectively. Particle size distribution revealed particles within the range of 0.1-100 μm. XRD analysis highlighted the presence of the ZrO2-tetragonal in both the Zr-1450 and Zr-1550 groups. Glass infiltration, however, led to the formation of the ZrO2-monoclinic of 9.84% (Zr-1450-G) and 18.34% (Zr-1550-G). SEM micrographs demonstrated similar microstructural characteristics for Zr-1450 and Zr-1550, whereas the glass-infiltrated groups exhibited comparable infiltration patterns. The highest characteristic strength was observed in the glass-infiltrated groups. Fractographic analyses suggested that fracture origins were related to defects on the tensile side, which propagated to the compression side of the samples. Both the sintering temperature and glass infiltration significantly influenced the mechanical properties of the 3Y-TZP recycled.
PMID: 38128470
ISSN: 1878-0180
CID: 5611772

A Narrative Review on Polycrystalline Ceramics for Dental Applications and Proposed Update of a Classification System

Benalcázar-Jalkh, Ernesto B; Bergamo, Edmara T P; Campos, Tiago M B; Coelho, Paulo G; Sailer, Irena; Yamaguchi, Satoshi; Alves, Larissa M M; Witek, Lukasz; Tebcherani, Sérgio M; Bonfante, Estevam A
Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias' translucency. However, concerns regarding the hydrothermal stability of partially stabilized zirconia and the trade-off observed between optical and mechanical properties resulting from the increased cubic content remain issues of concern. While the significant developments in polycrystalline ceramics have led to a wide diversity of zirconia materials with different compositions, properties, and clinical indications, the implementation of strong, esthetic, and sufficiently stable materials for long-span fixed dental prostheses has not been completely achieved. Alternatives, including advanced polycrystalline composites, functionally graded structures, and nanosized zirconia, have been proposed as promising pathways to obtain high-strength, hydrothermally stable biomaterials. Considering the evolution of zirconia ceramics in dentistry, this manuscript aims to present a critical perspective as well as an update to previous classifications of dental restorative ceramics, focusing on polycrystalline ceramics, their properties, indications, and performance.
PMCID:10744432
PMID: 38138684
ISSN: 1996-1944
CID: 5611842

A Narrative Review on Polycrystalline Ceramics for Dental Applications and Proposed Update of a Classification System

Benalcázar-Jalkh, Ernesto B.; Bergamo, Edmara T.P.; Campos, Tiago M.B.; Coelho, Paulo G.; Sailer, Irena; Yamaguchi, Satoshi; Alves, Larissa M.M.; Witek, Lukasz; Tebcherani, Sérgio M.; Bonfante, Estevam A.
Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias"™ translucency. However, concerns regarding the hydrothermal stability of partially stabilized zirconia and the trade-off observed between optical and mechanical properties resulting from the increased cubic content remain issues of concern. While the significant developments in polycrystalline ceramics have led to a wide diversity of zirconia materials with different compositions, properties, and clinical indications, the implementation of strong, esthetic, and sufficiently stable materials for long-span fixed dental prostheses has not been completely achieved. Alternatives, including advanced polycrystalline composites, functionally graded structures, and nanosized zirconia, have been proposed as promising pathways to obtain high-strength, hydrothermally stable biomaterials. Considering the evolution of zirconia ceramics in dentistry, this manuscript aims to present a critical perspective as well as an update to previous classifications of dental restorative ceramics, focusing on polycrystalline ceramics, their properties, indications, and performance.
SCOPUS:85180618008
ISSN: 1996-1944
CID: 5630642