Try a new search

Format these results:

Searched for:

person:colbyk01

in-biosketch:true

Total Results:

111


Descemet Membrane Endothelial Keratoplasty After Failed Descemet Stripping Without Endothelial Keratoplasty [Case Report]

Rao, Rohini; Borkar, Durga S; Colby, Kathryn A; Veldman, Peter B
PURPOSE/OBJECTIVE:To describe the clinical course, surgical experience, and postoperative outcomes of 3 patients with Fuchs endothelial dystrophy who underwent Descemet membrane endothelial keratoplasty (DMEK) after failed Descemet stripping without endothelial keratoplasty. METHODS:Three patients who underwent DMEK for management of persistent corneal edema after deliberate Descemet stripping in the setting of Fuchs endothelial dystrophy were identified. Patients were examined at day 1, week 1, and months 1, 3, and 6 after DMEK. Visual acuity, central corneal thickness (CCT), and evaluation of central corneal endothelial cell counts were recorded. RESULTS:Two women and one man, aged 56, 72, and 68 years, were included. The time interval between primary Descemet stripping and DMEK ranged from 3.5 to 8 months. Preoperative visual acuities were 20/200, 20/300, and 20/80. Immediately before DMEK, no patients had countable central endothelial cells, and CCTs were 825, 1034, and 878 μm. After DMEK, all patients had improvement in visual acuity to 20/70, 20/20, and 20/20 with CCTs of 529, 504, and 528. The postoperative period in the first case was notable for the immediate development of a pigmented pupillary membrane with posterior synechiae, as well as cystoid macular edema, of uncertain chronicity, noted 1 month postoperatively. The second case also developed posterior synechiae. Two cases completed 6-month endothelial cell counts totaling 2200 and 3114 cells per square millimeter (endothelial cell loss of 13% and 5.3%). CONCLUSIONS:DMEK is a reliable procedure to facilitate corneal rehabilitation and visual recovery in the event of poor corneal clearance after Descemet stripping without endothelial keratoplasty.
PMID: 28437275
ISSN: 1536-4798
CID: 4501312

Pigmented Caruncular Apocrine Hidrocystoma With Oncocytic Features [Case Report]

Jakobiec, Frederick A; Stagner, Anna M; Colby, Kathryn A
An unprecedented pigmented caruncular apocrine hidrocystoma with the additional feature of an oncocytic transformation of the cyst's lining cells is reported. Over a year, a 79-year-old woman developed a centrally pigmented lesion of her right caruncle with translucent borders. Because of concern about a melanoma, a carunculectomy with adjunctive cryotherapy and placement of an amniotic membrane graft were performed, and the excised specimen was evaluated microscopically. A large cyst dominated the caruncle and was lined by an inner layer of columnar eosinophilic and granular cells with an outer, interrupted layer of flattened myoepithelial cells. Phosphotungstic acid hematoxylin staining disclosed myriad cytoplasmic, dot-like mitochondria signifying an oncocytic change. Immunohistochemistry revealed gross cystic fluid disease protein-15 and cytokeratin 7-positivity indicative of apocrine differentiation. Oncocytic change is characteristically encountered in lacrimal ductal cysts and tumors.
PMID: 25794031
ISSN: 1537-2677
CID: 4501222

Boston keratoprosthesis type I in the elderly

Homayounfar, Gelareh; Grassi, Christina M; Al-Moujahed, Ahmad; Colby, Kathryn A; Dohlman, Claes H; Chodosh, James
BACKGROUND/AIMS:To determine the outcomes of Boston type I keratoprosthesis implanted in elderly patients. METHODS:A retrospective case series was performed on patients at least 75 years old who received the Boston type I keratoprosthesis between 1 January 2007 and 31 December 2012. Preoperative diagnosis, interval visual acuity, keratoprosthesis retention and postoperative complications were recorded for each patient. RESULTS:Forty-four Boston type I keratoprostheses were implanted in 44 eyes of 43 patients. The most common indication for surgery was corneal graft failure (n=23; 52.3%) followed by corneal scar (n=8; 18.2%) and limbal stem cell dysfunction (n=8; 18.2%). All patients had preoperative visual acuity of ≤20/200. Thirty-six of 44 (82%) patients achieved visual acuity of 20/200 or better postoperatively, and 20 of those (55.6%) maintained 20/200 or better for 1 year after surgery. The median length of follow-up was 825 days (range: 27-2193 days), and at the last follow-up visit, 20 of 44 (45.5%) had 20/200 or better vision. The median best-corrected visual acuity (logMAR) improved from 2.6 preoperatively to 1.0 at 1 year postoperative (p<0.00001). Device retention at 1 year postoperative was 88.9%. The most common postoperative complications were retroprosthetic membrane formation in 20 patients (45.5%) and cystoid macular oedema in six patients (13.6%). One patient developed keratitis and consecutive endophthalmitis 2 months after surgery and required enucleation. CONCLUSIONS:Boston type I keratoprosthesis is an effective modality in corneal blindness in elderly patients. Failure to restore or maintain ambulatory vision was typically due to non-corneal comorbidities, often unrelated to the keratoprosthesis.
PMID: 27381593
ISSN: 1468-2079
CID: 4501292

Outcomes of Descemet Stripping Endothelial Keratoplasty Using Eye Bank-Prepared Preloaded Grafts

Palioura, Sotiria; Colby, Kathryn
PURPOSE/OBJECTIVE:To evaluate the feasibility of Descemet stripping endothelial keratoplasty using grafts preloaded by an eye bank in a commercially available insertion device. METHODS:In this retrospective case series, a series of 35 eyes in 34 consecutive patients who underwent Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy or previously failed full-thickness grafts at a single tertiary care center from March 2013 to March 2014 was included. The donor tissue had undergone pre-lamellar dissection, trephination, and loading into EndoGlide Ultrathin inserters at the Lions Eye Institute for Transplant and Research (Tampa, FL) and was shipped overnight in Optisol GS to the surgeon (K.C.). Surgery was performed within 24 hours from tissue preparation and loading by the eye bank. Donor and recipient characteristics, endothelial cell density (ECD), best-corrected visual acuity, and central corneal thickness were recorded. The main outcome measures were intraoperative and postoperative complications and ECD loss at 3, 6, and 12 months. RESULTS:One primary graft failure (2.8%), 2 rebubblings (5.7%), and 1 graft rejection (2.8%) occurred. Mean preoperative donor ECD was 2821 ± 199 cells/mm. Six months postoperatively, the mean endothelial cell loss was 25.3% ± 17.2% (n = 32), which remained stable at 1 year (31.5% ± 17.9%, n = 32). Mean best-corrected visual acuity improved from 20/100 preoperatively to 20/25 at a mean follow-up of 1 year (n = 32). Mean central corneal thickness was reduced from 711 ± 110 μm to 638 ± 66 μm at the last follow-up visit. CONCLUSIONS:Donor graft tissue preloaded by an eye bank can be used successfully for endothelial keratoplasty. Preloading reduces intraoperative tissue manipulation.
PMID: 27741016
ISSN: 1536-4798
CID: 4501302

Treatment of Fuchs Endothelial Dystrophy by Descemet Stripping Without Endothelial Keratoplasty

Borkar, Durga S; Veldman, Peter; Colby, Kathryn A
PURPOSE/OBJECTIVE:To evaluate the effect of deliberate removal of the central Descemet membrane on endothelial function and morphology in patients with Fuchs endothelial dystrophy (FED) and cataract undergoing phacoemulsification. METHODS:In this retrospective case series, patients with FED and visually significant cataract underwent phacoemulsification in an academic cornea practice in Boston, MA. Four millimeters of the central Descemet membrane was stripped and removed after intraocular lens insertion. Vision, corneal pachymetry, and confocal imaging of the endothelial anatomy were performed before surgery and at 1, 3, 6, and 12 months after surgery. Patients were classified as fast responders, responders, slow responders, and nonresponders on the basis of postoperative time to resolution of corneal edema with visible central endothelial mosaic. RESULTS:Eleven patients (13 eyes) aged 51 to 91 years were included in the study. No eyes had countable central endothelial cells by confocal imaging before surgery. Preoperative visual acuity ranged from 20/25 to 20/400. All corneas showed stromal and microcystic edema in the area of Descemet stripping at days 1 and 7 after surgery. Four eyes demonstrated resolution of corneal edema with visible central endothelial cell mosaic (range: 410-864 cells/mm) by postoperative month 1 with visual acuity ranging between 20/25 and 20/40. Four additional eyes demonstrated a similar response by postoperative month 3 and an additional 2 eyes had resolution of corneal edema with an intact central endothelial mosaic at postoperative month 6 or later. Cell counts (range: 428-864 cells/mm) were maintained in all 10 responders at the last follow-up visit (range: postoperative months 6-24). Final vision ranged from 20/15 to 20/20 in these 10 eyes with the exception of 2 eyes with retinal pathology. Three eyes required endothelial keratoplasty. CONCLUSIONS:Repopulation of the central corneal endothelium with corneal deturgescence can occur after deliberate central Descemet stripping in patients with FED who underwent cataract removal. This may offer a novel treatment for patients with FED that could reduce the need for endothelial transplantation. Further studies are needed to delineate the optimal patient population for Descemet stripping because not all patients will respond to this intervention.
PMID: 27310885
ISSN: 1536-4798
CID: 4501272

Re: Lee et al.: Boston keratoprosthesis: outcomes and complications: a report by the American Academy of Ophthalmology (Ophthalmology 2015;122:1504-11) [Comment]

Kaufman, Aaron R; Colby, Kathryn A
PMID: 27342333
ISSN: 1549-4713
CID: 4501282

Corneal Reinnervation and Sensation Recovery in Patients With Herpes Zoster Ophthalmicus: An In Vivo and Ex Vivo Study of Corneal Nerves [Case Report]

Cruzat, Andrea; Hamrah, Pedram; Cavalcanti, Bernardo M; Zheng, Lixin; Colby, Kathryn; Pavan-Langston, Deborah
PURPOSE/OBJECTIVE:To study corneal reinnervation and sensation recovery in Herpes zoster ophthalmicus (HZO). METHODS:Two patients with HZO were studied over time with serial corneal esthesiometry and laser in vivo confocal microscopy (IVCM). A Boston keratoprosthesis type 1 was implanted, and the explanted corneal tissues were examined by immunofluorescence histochemistry for βIII-tubulin to stain for corneal nerves. RESULTS:The initial central corneal IVCM performed in each patient showed a complete lack of the subbasal nerve plexus, which was in accordance with severe loss of sensation (0 of 6 cm) measured by esthesiometry. When IVCM was repeated 2 years later before undergoing surgery, case 1 showed a persistent lack of central subbasal nerves and sensation (0 of 6). In contrast, case 2 showed regeneration of the central subbasal nerves (4786 μm/mm) with partial recovery of corneal sensation (2.5 of 6 cm). Immunostaining of the explanted corneal button in case 1 showed no corneal nerves, whereas case 2 showed central and peripheral corneal nerves. Eight months after surgery, IVCM was again repeated in the donor tissue around the Boston keratoprosthesis in both patients to study innervation of the corneal transplant. Case 1 showed no nerves, whereas case 2 showed new nerves growing from the periphery into the corneal graft. CONCLUSIONS:We demonstrate that regaining corneal innervation and corneal function are possible in patients with HZO as shown by corneal sensation, IVCM, and ex vivo immunostaining, indicating zoster neural damage is not always permanent and it may recover over an extended period of time.
PMCID:4816653
PMID: 26989956
ISSN: 1536-4798
CID: 4501262

Periprosthetic Tissue Loss in Patients With Idiopathic Vitreous Inflammation After the Boston Keratoprosthesis

Grassi, Christina M; Cruzat, Andrea; Taniguchi, Elise V; Crnej, Alja; Colby, Kathryn A; Dohlman, Claes H; Chodosh, James
PURPOSE/OBJECTIVE:Idiopathic vitritis is a poorly understood complication after Boston keratoprosthesis surgery with unclear etiology. We sought to determine whether an association exists between periprosthetic corneal tissue loss and the development of idiopathic vitritis in keratoprosthesis recipients. METHODS:Thirteen Boston type I keratoprosthesis recipient eyes with a history of idiopathic vitritis and 34 type I keratoprosthesis recipient eyes with no history of idiopathic vitritis underwent anterior segment optical coherence tomography (AS-OCT) at a median time postoperatively of 2.4 years versus 1.9 years (range, 0.5-14.2 vs. 0.1-13.6 years), respectively. Areas of corneal graft tissue loss ("gaps") around the keratoprosthesis stem were identified and analyzed by 2 masked observers. The difference in the presence, number, and size of gaps was compared between cases and controls. RESULTS:A periprosthetic gap was identified more commonly in idiopathic vitritis cases than in controls on AS-OCT (11/13, 86% vs. 11/34, 33.3%, P < 0.001). The number of gaps between cases and controls was also significantly different (2.6 ± 1.6 vs. 0.5 ± 0.8, P < 0.001), but not the estimated gap area (0.056 ± 0.049 mm² vs. 0.039 ± 0.025 mm², P = 0.22). CONCLUSIONS:A significantly higher proportion of keratoprosthesis recipient eyes with idiopathic vitritis had corneal tissue loss around the keratoprosthesis stem than did controls. Tissue loss could serve as an entry point for debris or bacterial components, triggering idiopathic vitritis. Our study underscores the utility of AS-OCT imaging in the postoperative management of keratoprosthesis patients.
PMID: 26226472
ISSN: 1536-4798
CID: 4501242

Diffuse Epibulbar Complex Lacrimal-Cartilaginous Choristoma: Diagnostic Clues and Management [Case Report]

Grob, Seanna R; Jakobiec, Frederick A; Stagner, Anna M; Colby, Kathryn A
PURPOSE/OBJECTIVE:To describe the clinical and histopathologic features distinguishing an extensive complex choristoma of the epibulbar surface and to address the management of such lesions. METHODS:Clinical history, diagnostic imaging studies, and histopathologic sections stained with hematoxylin and eosin were reviewed from a 2-year-old girl with a congenital conjunctival lesion of the right eye that was surgically excised. RESULTS:The patient clinically displayed an extensive, vascularized amelanotic conjunctival lesion located superotemporally with extension onto the cornea. Her visual acuity was reduced to 20/670. The clinical diagnosis was a large lacrimal gland choristoma with corneal involvement and resulting deprivation amblyopia. The patient underwent an excision of the lesion including the corneal portion, and the ocular surface was reconstructed with amniotic membrane. Histopathologic evaluation disclosed lobules of lacrimal tissue and cartilage plaques, smooth muscle, and nerves consistent with a complex choristoma. Six weeks postoperatively, the visual acuity had improved to 20/180. The patient returned to her local ophthalmologist for amblyopia management. CONCLUSIONS:We emphasize the importance of recognizing lesion-induced amblyopia and the timely performance of appropriate surgery for complex epibulbar choristomas. A differential diagnosis of other congenital epibulbar lesions is provided.
PMID: 26147834
ISSN: 1536-4798
CID: 4501232

Primary implantation of type I Boston keratoprosthesis in nonautoimmune corneal diseases

Chang, Han-Ying Peggy; Luo, Zhonghui Katie; Chodosh, James; Dohlman, Claes H; Colby, Kathryn A
PURPOSE/OBJECTIVE:The aim of this study was to report outcomes of type I Boston keratoprosthesis (KPro) as primary corneal surgery in nonautoimmune corneal disorders. METHODS:In this retrospective, observational, large single-center case series of 43 eyes (37 patients) that were followed for an average of 39 months (1-6 years), primary implantation of the type I Boston KPro was performed in all patients. Visual acuity at year 1, visual acuity at last follow-up, and postoperative complication rates were examined for all eyes. RESULTS:Preoperative best-corrected visual acuity ranged from 20/60 to light perception, with vision of 20/200 or worse in 88%. Vision was ≥20/200 at 1 year in 77% of eyes (P < 0.0001). Complications included retroprosthetic membrane formation (51%), glaucoma progression (47%), corneal melt (19%), and sterile vitritis (14%). CONCLUSIONS:In a large series with long follow-up, primary Boston KPro effectively restored vision. Close follow-up is needed to manage the known complications after Boston KPro.
PMID: 25611395
ISSN: 1536-4798
CID: 4501212