Try a new search

Format these results:

Searched for:

person:ror01

in-biosketch:true

Total Results:

28


Echocardiographic Imaging for Transcatheter Tricuspid Edge-to-Edge Repair

Ro, Richard; Tang, Gilbert H L; Seetharam, Karthik; Khera, Sahil; Sharma, Samin K; Kini, Annapoorna S; Lerakis, Stamatios
PMID: 32089056
ISSN: 2047-9980
CID: 4482252

Stress Cardiomyopathy in a Patient with Hypertrophic Cardiomyopathy: Case Presentation and Review of the Literature [Case Report]

Vinardell, Juan M; Mihos, Christos G; Nader, Adam; Ro, Richard; Escolar, Esteban; Santana, Orlando
Stress cardiomyopathy and hypertrophic cardiomyopathy are two distinct entities with different pathophysiologic causes. In the recent medical literature their concurrency has been described. During the acute phase of a stress cardiomyopathy making the diagnosis of a concomitant hypertrophic cardiomyopathy may be challenging, and has important implications in both the acute and longterm clinical management. Herein, we present a case of a stress cardiomyopathy occurring in a patient with hypertrophic cardiomyopathy, along with a review of the literature.
PMID: 31032604
ISSN: 1530-6550
CID: 4482242

Mitral valve coaptation and its relationship to late diastolic flow: A color Doppler and vector flow map echocardiographic study in normal subjects

Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard
BACKGROUND: Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. METHODS AND RESULTS: We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78+/-16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. CONCLUSIONS: Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow.
PMID: 28247433
ISSN: 1540-8175
CID: 2471272

Reply: The Strain, the Valve, and the LVOT Obstruction [Letter]

Sherrid, Mark V; Ro, Richard; Halpern, Dan; Sahn, David J; Homel, Peter; Arabadjian, Milla; Lopresto, Charles
PMID: 25953757
ISSN: 1558-3597
CID: 1570742

Statins and cognitive function: an updated review

Chatterjee, Saurav; Krishnamoorthy, Parasuram; Ranjan, Pragya; Roy, Ahana; Chakraborty, Anasua; Sabharwal, Manpreet Singh; Ro, Richard; Agarwal, Vikram; Sardar, Partha; Danik, Jacqueline; Giri, Jay S; DeGoma, Emil M; Kumbhani, Dharam J
Ischemic heart disease remains the leading cause of death in the USA. Statins have substantially contributed to the decline in mortality due to heart disease. Historically, statins are hypothesized to be neuroprotective and beneficial in dementia, but recent reports have suggested an association with transient cognitive decline. We have critically appraised the relationship between statins and cognitive function in this review. Most of the data are observational and reported a protective effect of statins on dementia and Alzheimer's disease in patients with normal cognition at baseline. Few studies, including two randomized control trials, were unable to find a statistically significant decrease in the risk or improvement in patients with established dementia or decline in cognitive function with statin use. As more randomized control trials are required to definitively settle this, cardiovascular benefits of statins must be weighed against the risks of cognitive decline on an individual basis.
PMID: 25618304
ISSN: 1534-3170
CID: 4482232

Vector flow mapping in obstructive hypertrophic cardiomyopathy to assess the relationship of early systolic left ventricular flow and the mitral valve

Ro, Richard; Halpern, Dan; Sahn, David J; Homel, Peter; Arabadjian, Milla; Lopresto, Charles; Sherrid, Mark V
BACKGROUND: The hydrodynamic cause of systolic anterior motion of the mitral valve (SAM) is unresolved. OBJECTIVES: This study hypothesized that echocardiographic vector flow mapping, a new echocardiographic technique, would provide insights into the cause of early SAM in obstructive hypertrophic cardiomyopathy (HCM). METHODS: We analyzed the spatial relationship of left ventricular (LV) flow and the mitral valve leaflets (MVL) on 3-chamber vector flow mapping frames, and performed mitral valve measurements on 2-dimensional frames in patients with obstructive and nonobstructive HCM and in normal patients. RESULTS: We compared 82 patients (22 obstructive HCM, 23 nonobstructive HCM, and 37 normal) by measuring 164 LV pre- and post-SAM velocity vector flow maps, 82 maximum isovolumic vortices, and 328 2-dimensional frames. We observed color flow and velocity vector flow posterior to the MVL impacting them in the early systolic frames of 95% of obstructive HCM, 22% of nonobstructive HCM, and 11% of normal patients (p < 0.001). In both pre- and post-SAM frames, we measured a high angle of attack >60 degrees of local vector flow onto the posterior surface of the leaflets whether the flow was ejection (59%) or the early systolic isovolumic vortex (41%). Ricochet of vector flow, rebounding off the leaflet into the cul-de-sac, was noted in 82% of the obstructed HCM, 9% of nonobstructive HCM, and none (0%) of the control patients (p < 0.001). Flow velocities in the LV outflow tract on the pre-SAM frame 1 and 2 mm from the tip of the anterior leaflet were low: 39 and 43 cm/s, respectively. CONCLUSIONS: Early systolic flow impacts the posterior surfaces of protruding MVL initiating SAM in obstructive HCM.
PMID: 25440093
ISSN: 1558-3597
CID: 1570762

Health-related quality of life after transcatheter or surgical aortic valve replacement in high-risk patients with severe aortic stenosis: an updated review of literature

Chatterjee, Saurav; Kumbhani, Dharam Jaydeep; Sardar, Partha; Chakraborty, Anasua; Biondi-Zoccai, Giuseppe; Sabharwal, Manpreet Singh; Ro, Richard; Pratap, Balaji; Bavishi, Chirag P; Bangalore, Sripal
Recent trials have highlighted the comparable mortality benefits and durability of the results for patients with severe aortic stenosis (AS) and high surgical risk managed with either transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (AVR). Various national guidelines and international regulatory bodies have approved TAVR, thereby leading to potential wide usage and dissemination of this technique worldwide. Quality-of-life outcomes, in spite of being an important measure of success and acceptability of the procedure, have not been publicized as extensively. For high risk patients with severe AS, implementation of TAVR has resulted in comparable survival, but different and novel adverse events compared with AVR. We present an updated review focusing on the quality-of-life outcomes and issues with this new and important procedural approach.
PMID: 24585114
ISSN: 1523-3782
CID: 967402

Comparison of the diagnostic characteristics of two B-type natriuretic peptide point-of-care devices

Ro, Richard; Thode, Henry C; Taylor, Maria; Gulla, Janet; Tetrault, Ellen; Singer, Adam J
BACKGROUND:B-type natriuretic peptide (BNP) is used to diagnose heart failure (HF). OBJECTIVE:To compare the accuracy of two commercially available point-of-care (POC) devices for measuring B-type natriuretic peptide (BNP) in emergency department (ED) patients with suspected heart failure using the central laboratory testing results as the criterion standard. METHODS:Venous blood samples were collected from adults with suspected heart failure and split into three samples for BNP analysis: central laboratory (Siemens ADIVA Centaur; Siemens, Deerfield, IL), Triage BNP POC device (Biosite, San Diego, CA), and i-STAT BNP POC device (Abbott, East Windsor, NJ). The criterion standard for BNP levels was the central laboratory. RESULTS:Two hundred fifty patients were enrolled. Mean (SD) age was 70.7 (13.8) years; 200 (80%) were over age 55 years; 146 (58.4%) were male. A final hospital discharge diagnosis of heart failure was made in 108 (42%) patients. The i-STAT system yielded a result within a median of 9 min (interquartile range [IQR] 9-10 min). The Triage device yielded a result within a median of 19 min (IQR 15-22 min); p < 0.001. The device failure rate for the central laboratory (8 failures, 3.2%) was significantly higher than that of the i-STAT device (1 failure, 0.4%, p = 0.04), but not statistically different than the Triage device (3 failures, 1.2%). Neither the Triage nor the i-STAT were statistically different than the central laboratory result in terms of sensitivity; the i-STAT was less specific than the Triage result (p = 0.003). The area under the curve for the Triage device was 0.95 (95% confidence interval [CI] 0.91-0.98), whereas the area under the curve for the i-STAT device was 0.98 (95% CI 0.96-0.99; p < 0.01). CONCLUSIONS:Both POC devices tested were accurate and rarely failed; however, the i-STAT was faster with single use.
PMID: 21620610
ISSN: 0736-4679
CID: 4482222