Try a new search

Format these results:

Searched for:

person:zaimwy01

in-biosketch:yes

Total Results:

95


Tribute to Anne Bertrand (1978-2018): Neuroradiologist, scientist, teacher and friend In Memoriam [Biography]

Dormont, Didier; Ben-Eliezer, Noam; Burgos, Ninon; Colliot, Olivier; Fallani, Fabrizio De Vico; Dhenain, Marc; Durrleman, Stanley; Epelbaum, Stephane; Habert, Marie-Odile; Le Ber, Isabelle; Meder, Jean-Francois; Menu, Yves; Oppenheim, Catherine; Wadghiri, Youssef Z.
Anne Bertrand passed away on March 2nd 2018. She was in a touring-skiers group led by a guide and swept by an avalanche in the French Alps. This paper is a tribute to Anne and an attempt, by some of her closest colleagues, to provide an overview of her major contributions.
ISI:000463305800010
ISSN: 0150-9861
CID: 3809982

Novel Use of mu-PET/CT Imaging to Detect Cardiopulmonary Changes in a Murine Model Following World Trade Center Particular Matter Exposure [Meeting Abstract]

Oskuei, A.; Veerappan, A.; Vaidyanathan, S.; Crowley, G.; Wadghiri, Y.; Nolan, A.
ISI:000466771102338
ISSN: 1073-449x
CID: 3896782

World Trade Center Particulate Matter Associated Cardiopulmonary Dysfunction and Injury: Incorporating Echocardiography in a Murine Model [Meeting Abstract]

Veerappan, A.; Oskuei, A.; Vaidyanathan, S.; Crowley, G.; Wadghiri, Y.; Nolan, A.
ISI:000466771102336
ISSN: 1073-449x
CID: 3896762

Measurement of blood-brain barrier permeability using dynamic contrast-enhanced magnetic resonance imaging with reduced scan time

Bae, Jonghyun; Zhang, Jin; Wadghiri, Youssef Zaim; Minhas, Atul Singh; Poptani, Harish; Ge, Yulin; Kim, Sungheon Gene
PURPOSE/OBJECTIVE:To investigate the feasibility of measuring the subtle disruption of blood-brain barrier (BBB) using DCE-MRI with a scan duration shorter than 10 min. METHODS:) in the estimation of vascular permeability-surface area product (PS). Numerical simulation studies were carried out to investigate how the reduction in scan time affects the accuracy in estimating contrast kinetic parameters. DCE-MRI studies of the rat brain were conducted with Fisher rats to confirm the results from the simulation. Intracranial F98 glioblastoma models were used to assess areas with different levels of permeability. In the normal brain tissues, the Patlak model (PM) and EPM were compared, whereas the 2-compartment-exchange-model (TCM) and EPM were assessed in the peri-tumor and the tumor regions. RESULTS:was high as in the gray matter, the bias in PM-PS (>900%) were larger than that in EPM-PS (<42%). The animal study also showed similar results, where the PM parameters were more sensitive to the scan duration than the EPM parameters. It was also demonstrated that, in the peri-tumor region, the EPM parameters showed less change by scan duration than the TCM parameters. CONCLUSION/CONCLUSIONS:The results of this study suggest that EPM can be used to measure PS with a scan duration of 10 min or less.
PMID: 29508443
ISSN: 1522-2594
CID: 2975152

High-resolution Imaging of Myeloperoxidase Activity Sensors in Human Cerebrovascular Disease

Wadghiri, Youssef Z; Hoang, Dung Minh; Leporati, Anita; Gounis, Matthew J; Rodríguez-Rodríguez, Aurora; Mazzanti, Mary L; Weaver, John P; Wakhloo, Ajay K; Caravan, Peter; Bogdanov, Alexei A
Progress in clinical development of magnetic resonance imaging (MRI) substrate-sensors of enzymatic activity has been slow partly due to the lack of human efficacy data. We report here a strategy that may serve as a shortcut from bench to bedside. We tested ultra high-resolution 7T MRI (µMRI) of human surgical histology sections in a 3-year IRB approved, HIPAA compliant study of surgically clipped brain aneurysms. µMRI was used for assessing the efficacy of MRI substrate-sensors that detect myeloperoxidase activity in inflammation. The efficacy of Gd-5HT-DOTAGA, a novel myeloperoxidase (MPO) imaging agent synthesized by using a highly stable gadolinium (III) chelate was tested both in tissue-like phantoms and in human samples. After treating histology sections with paramagnetic MPO substrate-sensors we observed relaxation time shortening and MPO activity-dependent MR signal enhancement. An increase of normalized MR signal generated by ultra-short echo time MR sequences was corroborated by MPO activity visualization by using a fluorescent MPO substrate. The results of µMRI of MPO activity associated with aneurysmal pathology and immunohistochemistry demonstrated active involvement of neutrophils and neutrophil NETs as a result of pro-inflammatory signalling in the vascular wall and in the perivascular space of brain aneurysms.
PMCID:5956082
PMID: 29769642
ISSN: 2045-2322
CID: 3121122

In Vivo Evaluation of Neuronal Transport in Murine Models of Neurodegeneration Using Manganese-Enhanced MRI

Bertrand, Anne; Baron, Maria; Hoang, Dung M; Hill, Lindsay K; Mendoza, Sebastian L; Sigurdsson, Einar M; Wadghiri, Youssef Z
Manganese-enhanced MRI (MRI) is a technique that allows for a noninvasive in vivo estimation of neuronal transport. It relies on the physicochemical properties of manganese, which is both a calcium analogue being transported along neurons by active transport, and a paramagnetic compound that can be detected on conventional T1-weighted images. Here, we report a multi-session MEMRI protocol that helps establish time-dependent curves relating to neuronal transport along the olfactory tract over several days. The characterization of these curves via unbiased fitting enables us to infer objectively a set of three parameters (the rate of manganese transport from the maximum slope, the peak intensity, and the time to peak intensity). These parameters, measured previously in wild type mice during normal aging, have served as a baseline to demonstrate their significant sensitivity to pathogenic processes associated with Tau pathology. Importantly, the evaluation of these three parameters and their use as indicators can be extended to monitor any normal and pathogenic processes where neuronal transport is altered. This approach can be applied to characterize and quantify the effect of any neurological disease conditions on neuronal transport in animal models, together with the efficacy of potential therapies.
PMID: 29886555
ISSN: 1940-6029
CID: 3154912

Exploiting chemical biology to generate protein-iron oxide hybrid biomaterials for theranostics [Meeting Abstract]

Hill, Lindsay; Jihad, Teeb; Wadghiri, Youssef Zaim; Montclare, Jin
ISI:000429556703371
ISSN: 0065-7727
CID: 3049292

Iron oxide-decorated protein-engineered fibers for MRI-monitoring of chemotherapeutic delivery [Meeting Abstract]

Hill, L K; Liu, C F; Jihad, T; Vawda, S; Wadghiri, Y Z; Montclare, J K
Introduction Theranostics, combining diagnostic imaging with drug therapy, is promising in cancer treatment. Protein engineering may prove beneficial in theranostics development, allowing for the synthesis of rationally designed therapeutic platforms combinable with imaging probes. Here, we have engineered a theranostic agent entirely reliant on protein structure for drug binding and iron oxide (FeOx) organization and templation. FeOx is an appealing MRI probe because it is highly sensitive and well tolerated in vivo. We therefore propose that FeOx-decorated protein fibers should serve as a sensitive and biocompatible agent for tracking chemotherapeutic delivery via MRI. Our agent is based on self-assembling azide-functionalized fibers composed of a coiled-coiled protein1 with a hydrophobic pore for binding small molecules, such as anti-neoplastic curcumin. The azide moieties allow for functionalization including conjugation to an FeOx-templating peptide derived from the C-terminus of the magnetosome-associated protein Mms6 (dubbed CMms6)2. Methods Synthesis: Azide-functionalized protein was expressed in methionine auxotrophic E. coli using azidohomoalanine supplemented media. Pure protein was dialyzed into acidic pH initiating the assembly of nanofibers subsequently bound to curcumin1 forming fluorescent mesofibers then crosslinked for stability. Nanofibers and mesofibers were visualized with transmission electron microscopy (TEM) and fluorescence microscopy, respectively. Mesofibers were conjugated to alkyne-CMms6 via azide-alkyne cycloaddition and iron co-precipitation in the presence of CMms6- bound fibers yielded templated FeOx nanoparticles. Imaging: MR images and relaxometry were acquired at 7 Tesla on FeOx-bound fibers diluted in 2% agarose. 2D relaxation maps were acquired using a rapid acquisition with relaxation enhancement with variable repetition time (RAREVTR) sequence. Data was fit using T1 and T2 mono-exponential curves to determine relaxivity. T1 , T2 , and T2 *-weighted images were acquired using Look-Locker, multi-spin multi-echo, and multi-gradient echo sequences, respectively. Results TEM and fluorescence microscopy revealed fibers with an average diameter of 200nm (N=20) and 24mum (N=28) before and after curcumin binding. TEM analysis of FeOx-bound fibers revealed nanoparticles 6.6nm in diameter (N =20). A neodymium magnet confirmed the agent's magnetic responsiveness, to be further investigated by superconducting quantum interference device (SQUID) magnetometry. Relaxometry revealed a 5.7-fold higher r21 than clinical FeOx agent Feraheme, suggesting its use as a pure T2/T2* agent. Subsequent MRI confirmed the agent's potential in T2/T2 *-weighted imaging in comparison to its weak signal change when T1 -weighted. Conclusion By biologically synthesizing a coiled-coil protein and utilizing bio-inspired FeOx templation, we engineered a magnetically-functionalized drug-carrying vehicle. Initial studies suggest that this agent may have potential in magnetically-driven or implantable drug delivery visualized viaT2/T2 *-weighted MRI. (Figure Presented)
EMBASE:613937586
ISSN: 1860-2002
CID: 2395422

Rapid quantification of gadolinium in nanoparticles by time-resolved fluorescence [Meeting Abstract]

Hill, L K; Russell, S; Hoang, D M; Wadghiri, Y Z
Introduction Gadolinium (Gd)-based MRI contrast agents (GBCA) are crucial for the diagnosis and monitoring of various diseases. Their use in dynamic, such as perfusion MRI (pMRI), scans provides valuable information about tissue microenvironment and function beyond conventional assessment of lesion volume or area changes1,2. However, accurate concentration-time curves2 are required to quantitatively characterize diseased tissue, monitor therapeutic efficacy, and provide insight into drug mechanisms1. The increasing reliance on image-derived GBCA quantification is problematic as indirect signal measurement from surrounding proton exchange can be affected by non-linear relaxivity in tissue3, hardware imperfection, and motion. Direct GBCA quantification in plasma samples varies in sensitivity by method. Relaxivity achieves sub-millimolar sensitivity, requiring large sample volume, and although ICP-MS can detect nanomolar levels4, it is not readily available. We previously developed a technique to quantify a GBCA using Carbostyril 124 (cs124)-sensitized DTPA via energy transfer using a simple fluorescence plate reader widely available in research labs5. The present work extends our method to multivalent Gd complexes (see image). Methods All absorbance and fluorescence measurements were made in a standard plate reader. Amide chemistry was used to conjugate cs124 to DTPA-DPPE and Gd was chelated in water, yielding cs124-GdDTPA-DPPE. The absorption of cs124 at 330nm was used to quantify Gd. The product was dialyzed and the size distribution was assessed via dynamic light scattering (DLS). Time-resolved fluorescence, using excitation at 330nm and emission at 480nm, was integrated from 600mus-2000mus. The collision model of energy transfer was fit to fluorescence data to determine system sensitivity5. MRI: T1 images and relaxometry were acquired on a 7-Telsa Bruker using phantoms of cs124-GdDTPADPPE particles and clinical Gd-DTPA (Magnevist). Results DLS showed a monodisperse distribution with an average 575nm radius (Fig.1), consistent with liposomal structure expected from this lipid. The starting Gd concentration used for fluorescence studies was 35muM (Fig.2). The limit of detection was 67nM, which is comparable to ICP-MS4 (Fig. 3). T1-weighted MRI showed that our multivalent cs124-based T1-agent achieved a signal comparable to that of 10x higher concentration monovalent GdDTPA concentration (Fig.4). Relaxometry confirmed a 26.5x amplification in r1 and a 1.04 r2/r1 ratio (Table 1). Conclusion Incorporating cs124 into multivalent GBCAs proved effective in maintaining nanomolar quantification of Gd using a spectrophotometer. The cs124 conjugation did not hinder the agent's r1 relaxivity, suggesting its use in other novel GBCA of various sizes. This expedient system may significantly ease in-house throughput for MR agents' characterization and optimization. It may also prove useful to calibrate the arterial input function in pMRI studies. [IMAGE PRESENTED]
EMBASE:613981033
ISSN: 1860-2002
CID: 2415702

Traceable and thermoresponsive multifunctional engineered protein drug delivery agents for metastatic breast cancer [Meeting Abstract]

Frezzo, J A; Hoang, D M; Wadghiri, Y Z; Montclare, J K
Introduction Theranostics is the field whereby both drug delivery and imaging are merged to promote more effective therapies1. This is especially important in the delivery of small molecule cancer therapeutics such as doxorubicin (DOX) where clinicians must strike a balance between administering an effective dose while limiting off-target cardiotoxicity risks2. In this work, an engineered fluorinated protein polymer is investigated for theranostic use as a chemotherapeutic carrier and 19F MR agent. The fluorinated protein polymer, CE2-RGD-TFL, is comprised of two functional domains: 1) a coiled-coil domain (C), flanked by two integrin targeting domains, capable of encapsulating small hydrophobic drugs and; 2) two elastin-like peptide domains (E) that impart concentration-dependent thermoresponsiveness. In this study, we have characterized CE2-RGD-TFL as a promising thermally T2-dependent MRI tracer as well as thermoresponsive to drug release for DOX delivery properties. Materials and Methods Trifluoroleucine (TFL) incorporation was achieved via recombinant expression in leucine auxotrophic E. coli. Proteins were subjected to UV-Vis spectroscopy, circular dichroism (CD), dynamic light scattering (DLS) and 19F R1 (1/T1) and R2 (1/T2) NMR relaxometry at 11.7-Tesla (-T). Water Phantoms with and without CE2-RGD-TFL were imaged using a 7-T Bruker micro-MRI using a homemade broadband coil tunable to 19F or 1H. DOX-bound protein was separated from free drug by size exclusion chromatography (SEC). Results Fluorination imparts interesting thermoresponsive properties upon CE2-RGD. While the CD analysis reveals that CE2-RGD-TFL is less structured than the wild-type variant, CE2-RGD-TFL coacervates in the physiological range for hyperthermic treatment (39-42degreeC). Relaxometric characterization revealed a remarkable R2 linear dependence as a function of concentrations and temperatures and very little change in R1 (Fig. 1, plots). The predominant R2 linear sensitivity based on relative r2 /r1 ratio within physiological temperature range supports the prospect for using this protein as a T2-nano-thermometer. MRI water Phantoms with and without CE2-RGD-TFL were expectedly visible with 1H MRI while only CE2-RGD-TFL was visualized in 19F imaging. Importantly, CE2-RGD-TFL exhibited a 2.75 times increase in DOX loading (49.1%) compared to CE2-RGD with only 17.8% loading. Conclusion Incorporation of TFL in CE2-RGD yields a drug carrier nanoparticle that can undergo temperature dependent structural changes associated with R2 linear variation, making this compound a great potential candidate as a nanothermometric tracer. Furthermore, preliminary 19F MRI confirmed our ability to visualize CE2-RGD-TFL. Finally, fluorination imparts both greater thermoresponsiveness and greater loading of doxorubicin which provides further value to CE2-RGD-TFL as a theranostic agent. Future work includes ultra-short echo time MRI to increase sensitivity and testing of the targeting capability to integrin +/- breast cell lines for effective DOX delivery and release upon hyperthermic induction
EMBASE:613981120
ISSN: 1860-2002
CID: 2415682