Try a new search

Format these results:

Searched for:

department:Ophthalmology

recent-years:2

school:SOM

Total Results:

353


Opting out of Medicare: Characteristics and differences between optometrists and ophthalmologists

Maywood, Michael J; Ahmed, Harris; Parikh, Ravi; Begaj, Tedi
OBJECTIVE:To determine the rate of Medicare opt-out among optometrists and ophthalmologists and to contrast the differences in the characteristics and geographic distribution of these populations. DESIGN/METHODS:A retrospective cross-sectional study. SETTING/METHODS:Using a publicly available Centers for Medicare & Medicaid Services (CMS) data set, we collated data for ophthalmologists and optometrists who opted out in each year between 2005 and 2023. We calculated the rate of opt-out annually in each year window and cumulatively from 2005 to 2023. Comparative analysis was used to identify clinician characteristics associated with opt-out. MAIN OUTCOMES AND MEASURES/METHODS:Both annual and cumulative rate of ophthalmologist and optometrist opt-out from Medicare. RESULTS:The estimated prevalence of Medicare opt-outs was 0.52% (77/14,807) for ophthalmologists and 0.38% (154/40,526) for optometrists. Ophthalmologists opting out were predominantly male (67.5%), had a longer practice duration (average 31.8 years), and were more often located in urban areas (83.1%), compared to optometrists (53.2% male, average 19.6 years in practice, 59.1% in urban areas, p = 0.04, p<0.001, p<0.001 respectively). Approximately 83% of ophthalmologists were either anterior segment or oculoplastics specialties, while the majority (52.1%) of optometrists were in optometry-only practices; >75% of identified clinicians were in private practice. Geographical distribution across the US showed variable opt-out rates, with the top 3 states including Oklahoma (3.4%), Arizona (2.1%), and Kansas (1.6%) for ophthalmology and Idaho (4.3%), Montana (3.1%), and Wyoming (1.4%) for optometry. CONCLUSIONS AND RELEVANCE/CONCLUSIONS:Few ophthalmologists and optometrists opt-out of Medicare but this trend has significantly increased since 2012. Of those who disenrolled from Medicare, 83% of ophthalmologists were in urbanized areas while 41% of optometrists were in non-urbanized areas. Because reasons for Medicare opt-out cannot be solely determined by administrative data, further investigation is warranted given the potential impact on healthcare accessibility.
PMCID:11383217
PMID: 39250498
ISSN: 1932-6203
CID: 5690032

INTERACTIONS OF METFORMIN AND OTHER MEDICATIONS IN REDUCING THE ODDS OF AGE-RELATED MACULAR DEGENERATION IN A COHORT OF PATIENTS WITH DIABETES

Shaw, Lincoln; Khanna, Saira; Hyman, Max J.; Ham, Sandra; Blitzer, Andrea; Parvar, Seyedeh P.; Soo, Jackie; Flores, Andrea; Hariprasad, Seenu; Skondra, Dimitra
ISI:001148297700021
ISSN: 0275-004x
CID: 5994512

Application of Negative Pressure by the Ocular Pressure Adjusting Pump to Provide a Sustained Reduction in IOP

Ferguson, Tanner J; Herndon, Leon W; Terveen, Daniel C; Shah, Manjool; Samuelson, Thomas W; Yoo, Paul; Berdahl, John P
PURPOSE/UNASSIGNED:To evaluate the sustainability of IOP reduction with continuous negative pressure application over an extended duration with use of the Ocular Pressure Adjusting Pump. METHODS/UNASSIGNED:Prospective, controlled, open-label, randomized, single site, pilot study. Subjects with primary open-angle glaucoma (OAG) were enrolled. One eye of each subject was randomized to receive negative pressure application; the fellow eye served as a control. The study eye negative pressure setting was programmed for 60% of the baseline IOP. Subjects wore the Ocular Pressure Adjusting Pump for 8 consecutive hours and IOP measurements occurred at 2-hour intervals for a total of 5 IOP measurements (08:00, 10:00, 12:00, 14:00, 16:00). RESULTS/UNASSIGNED:Nine subjects successfully enrolled and completed the study. The mean programmed negative pressure setting was -12.0 mmHg. At baseline, the mean IOP in the study eye was 21.4 ± 4.3 mmHg. The mean IOP reduction in the study eye at hours 0, 2, 4, 6, and 8 was 8.1 (37%), 6.4 (28%), 6.3 (29%), 7.3 (34%) and 6.7 (31%), respectively. All IOP measurements during negative pressure application were reduced from baseline. There were no serious adverse events. CONCLUSION/UNASSIGNED:The Ocular Pressure Adjusting Pump provides a sustained reduction in IOP while the device is worn with negative pressure applied with an IOP reduction exceeding 25% across 8 hours of continuous wear.
PMCID:11550690
PMID: 39525873
ISSN: 1177-5467
CID: 5752542

Early diagnostics and interventional glaucoma

De Francesco, Ticiana; Bacharach, Jason; Smith, Oluwatosin; Shah, Manjool
The glaucoma treatment paradigm is starting to change from a more reactive approach that relies on topical medications to a more proactive approach that leverages procedural interventions. This evolution toward interventional glaucoma has been enabled by a growing array of lower-risk minimally invasive procedures such as laser trabeculoplasty, minimally invasive glaucoma surgery, and procedural pharmaceuticals. A common feature of these glaucoma interventions-as with all glaucoma interventions-is the need for early, prompt, and accurate diagnosis. The present review summarizes new and upcoming developments in glaucoma diagnostics. These include technologies and techniques for home-based intraocular pressure measurement, novel visual field platforms, photography- and optical coherence tomography-based visualization, and artificial intelligence applications. They also include emerging technologies such as mitochondrial flavoprotein fluorescence imaging, detection of apoptosing retinal cells, collector channel visualization, and genetic testing. These diagnostic modalities have the potential to circumvent the limitations of traditional diagnostic methods. By increasing the frequency and feasibility of obtaining valuable glaucoma data with more rapid detection of disease and progression, these diagnostics may enable an interventional approach to glaucoma treatment for the betterment of patient care.
PMCID:11483761
PMID: 39421852
ISSN: 2515-8414
CID: 5718842

Corneal Epithelial Thickness in Sjogren's Disease: A Pilot Study

Nguyen, Brian J; Gupta, Angela S; He, Jocelyn; Ying, Gui-Shuang; Bunya, Vatinee Y; Macchi, Ilaria; Massaro-Giordano, Mina
PURPOSE/UNASSIGNED:This study was to assess corneal epithelial thickness (CET) in patients with Sjogren's disease (SjD). METHODS/UNASSIGNED:A retrospective chart review was conducted of SjD patients from September 2021 to January 2022. Patient demographics, unanesthetized Schirmer's test, serologic markers, and symptoms as measured by the Ocular Surface Disease Index (OSDI) were reviewed. Epithelial thickness from both eyes was measured using anterior segment OCT at the central 3mm and concentric 5mm, 7mm, and 9mm zones for the superior, temporal, inferior, and nasal corneal quadrants. Associations between corneal epithelial thickness with patient demographics, clinical characteristics, and symptoms were evaluated using regression models. RESULTS/UNASSIGNED:Fifteen SjD patients (100% female) were included with a mean age of 58.4 years. Patients with Sjogren's disease had a significantly thinner superior corneal epithelium compared to the inferior epithelium (mean 47.7mm vs 53.1mm, p = 0.001). The epithelial thickness mean standard deviation (MSD) was significantly inversely correlated with the unanesthetized Schirmer test (r=-0.39, p = 0.005), suggesting that an overall variability of CET correlates with decreased aqueous tear production. SS-A, SS-B, ANA, and RF positivity were not associated with any measures of CET. CONCLUSION/UNASSIGNED:This pilot study suggests that there is significant superior versus inferior thinning of corneal epithelium in Sjogren's patients. There was a significant correlation between variability of corneal epithelial thickness and decreased tear production in Sjogren's patients. Further larger studies are needed to understand the relationship of CET with objective and subjective measurements of ocular surface disease.
PMCID:11298560
PMID: 39104872
ISSN: 1177-5467
CID: 5849472

Response of Diabetic Macular Edema to Anti-VEGF Medications Correlates with Improvement in Macular Vessel Architecture Measured with OCT Angiography

Massengill, Michael T; Cubillos, Samuel; Sheth, Neil; Sethi, Abhishek; Lim, Jennifer I
PURPOSE/UNASSIGNED:Improvements in best-corrected visual acuity (BCVA) and central subfield thickness (CST) have been well documented after intravitreal injection of anti-VEGF medications in diabetic macular edema (DME); however, their effect on the vasculature of the macula in diabetic retinopathy (DR) remains poorly understood. Our aim was to explore the effect of intravitreal injection of anti-VEGF on parameters of retinal vascular microstructure in DR with OCT angiography (OCTA). DESIGN/UNASSIGNED:Retrospective study of adult patients with DME that were treated with anti-VEGF intravitreal injections at the University of Illinois at Chicago between 2017 and 2022. PARTICIPANTS/UNASSIGNED:Forty-one eyes from 30 patients with nonproliferative or proliferative DR with a mean age of 58.83 ± 11.71 years, mean number of intravitreal injections of 2.8 ± 1.4, and mean follow-up of 6.5 ± 1.7 months. METHODS/UNASSIGNED:tests and analysis of variance were used to determine statistical significance. MAIN OUTCOME MEASURES/UNASSIGNED:A primary analysis was performed comparing the mean of each parameter of all patients as a single group at the beginning and end of the study period. A subgroup analysis was then performed after stratifying patients based on visual improvement, change in CST, prior injection history, and number of injections. RESULTS/UNASSIGNED:Eyes demonstrated statistical improvement in BCVA logarithm of the minimum angle of resolution score and CST after anti-VEGF treatment. Primary analysis showed a reduction in the vessel diameter of the superficial and deep retinal vasculature, as well as an increase in the circularity of the FAZ within the superficial retinal vasculature after anti-VEGF treatment. Subgroup analysis revealed that eyes with improvement in BCVA exhibited reduced vessel diameter in the superficial retinal vasculature and that eyes with the largest decrease in CST displayed increased perfusion density and VLD in the deep retinal vasculature. CONCLUSIONS/UNASSIGNED:Intravitreal injection of anti-VEGF agents to treat DME improved parameters of retinal vascular microstructure on OCTA over a period of 3 to 9 months, and this effect was most pronounced in eyes that experienced improvement in BCVA and CST. FINANCIAL DISCLOSURES/UNASSIGNED:Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
PMCID:11141254
PMID: 38827030
ISSN: 2666-9145
CID: 5922972

Rod mediated dark adaptation, a functional test for early and intermediate AMD outcomes

Owsley, Cynthia; Swain, Thomas A; Kar, Deepayan; Curcio, Christine A
PMCID:10869142
PMID: 38370915
ISSN: 1746-9899
CID: 5929252

Imaging Modalities for Assessing the Vascular Component of Diabetic Retinal Disease: Review and Consensus for an Updated Staging System

Tan, Tien-En; Jampol, Lee M; Ferris, Frederick L; Tadayoni, Ramin; Sadda, Srinivas R; Chong, Victor; Domalpally, Amitha; Blodi, Barbara L; Duh, Elia J; Curcio, Christine A; Antonetti, David A; Dutta, Sanjoy; Levine, S Robert; Sun, Jennifer K; Gardner, Thomas W; Wong, Tien Yin
PURPOSE/UNASSIGNED:To review the evidence for imaging modalities in assessing the vascular component of diabetic retinal disease (DRD), to inform updates to the DRD staging system. DESIGN/UNASSIGNED:Standardized narrative review of the literature by an international expert workgroup, as part of the DRD Staging System Update Effort, a project of the Mary Tyler Moore Vision Initiative. Overall, there were 6 workgroups: Vascular Retina, Neural Retina, Systemic Health, Basic and Cellular Mechanisms, Visual Function, and Quality of Life. PARTICIPANTS/UNASSIGNED:The Vascular Retina workgroup, including 16 participants from 4 countries. METHODS/UNASSIGNED:Literature review was conducted using standardized evidence grids for 5 modalities: standard color fundus photography (CFP), widefield color photography (WFCP), standard fluorescein angiography (FA), widefield FA (WFFA), and OCT angiography (OCTA). Summary levels of evidence were determined on a validated scale from I (highest) to V (lowest). Five virtual workshops were held for discussion and consensus. MAIN OUTCOME MEASURES/UNASSIGNED:Level of evidence for each modality. RESULTS/UNASSIGNED:Levels of evidence for standard CFP, WFCP, standard FA, WFFA, and OCTA were I, II, I, I, and II respectively. Traditional vascular lesions on standard CFP should continue to be included in an updated staging system, but more studies are required before they can be used in posttreatment eyes. Widefield color photographs can be used for severity grading within the area covered by standard CFPs, although these gradings may not be directly interchangeable with each other. Evaluation of the peripheral retina on WFCP can be considered, but the method of grading needs to be clarified and validated. Standard FA and WFFA provide independent prognostic value, but the need for dye administration should be considered. OCT angiography has significant potential for inclusion in the DRD staging system, but various barriers need to be addressed first. CONCLUSIONS/UNASSIGNED:This study provides evidence-based recommendations on the utility of various imaging modalities for assessment of the vascular component of DRD, which can inform future updates to the DRD staging system. Although new imaging modalities offer a wealth of information, there are still major gaps and unmet research needs that need to be addressed before this potential can be realized. FINANCIAL DISCLOSURES/UNASSIGNED:Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
PMCID:10837643
PMID: 38313399
ISSN: 2666-9145
CID: 5930622

Deep Learning Assisted Imaging Methods to Facilitate Access to Ophthalmic Telepathology

Browne, Andrew W; Kim, Geunwoo; Vu, Anderson N; To, Josiah K; Minckler, Don S; Estopinal, Maria Del Valle; Rao, Narsing A; Curcio, Christine A; Baldi, Pierre F
PURPOSE/UNASSIGNED:To investigate the use of super-resolution imaging techniques to enable telepathology using low-cost commercial cameras. DESIGN/UNASSIGNED:Experimental study. PARTICIPANTS/UNASSIGNED:A total of 139 ophthalmic pathology slides obtained from the Ophthalmic Pathology service at the University of California, Irvine. METHODS/UNASSIGNED:Denoising Diffusion Probabilistic Model (DDPM) was developed to predict super-resolution pathology slide images from low-resolution inputs. The model was pretrained using 150 000 images randomly sampled from the ImageNet dataset. Patch aggregation was used to generate large images with DDPM. The performance of DDPM was evaluated against that of generative adversarial networks (GANs) and Robust UNet, which were also trained on the same dataset. MAIN OUTCOME MEASURES/UNASSIGNED:The performance of models trained to generate super-resolution output images from low-resolution input images can be evaluated by using the mean squared error (MSE) and Structural Similarity Index Measure (SSIM), as well as subjective grades provided by expert pathologist graders. RESULTS/UNASSIGNED:In total, our study included 110 training images, 9 validation images, and 20 testing images. The objective performance scores were averaged over patches generated from 20 test images. The DDPM-based approach with pretraining produced the best results, with an MSE score of 1.35e-5 and an SSIM score of 0.8987. A qualitative analysis of super-resolution images was conducted by expert 3 pathologists and 1 expert ophthalmic microscopist, and the average accuracy of identifying the correct ground truth images ranged from 25% to 70% (with an average accuracy of 46.5%) for widefield images and 25% to 60% (with an average accuracy of 38.25%) for individual patches. CONCLUSIONS/UNASSIGNED:The DDPM-based approach with pretraining is assessed to be effective at super-resolution prediction for ophthalmic pathology slides both in terms of objective and subjective measures. The proposed methodology is expected to decrease the reliance on costly slide scanners for acquiring high-quality pathology slide images, while also streamlining clinical workflow and expanding the scope of ophthalmic telepathology. FINANCIAL DISCLOSURES/UNASSIGNED:Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
PMCID:10847934
PMID: 38327842
ISSN: 2666-9145
CID: 5930632

KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE

Kalogeropoulos, Dimitrios; Shaw, Lincoln; Skondra, Dimitra; Ch\ng, Soon Wai; Christodoulou, Aikaterini; Kalogeropoulos, Chris
ISI:001014834100002
ISSN: 0023-2165
CID: 5994632