Searched for: person:chinil01
Autonomic manipulation influences both temporal and frequency analyses of late potentials
Schwartzman D; Demopoulos L; Schrem S; Caracciolo E; Perez J; Chinitz L; Slater W
Previous studies of late potentials have not standardized the autonomic milieu at the time of testing. We studied the effects of autonomic manipulation in seven patients with previous Q wave myocardial infarction. Late potentials were evaluated using standard temporal (TD) and spectral temporal mapping techniques (STM) in the drug free state, and during separate intravenous administration of each of the following: isoproterenol, esmolol, and atropine. Isoproterenol was titrated to achieve a heart rate of 130% of baseline. Esmolol was infused at a rate of 250 micrograms/kg per minute, after a loading dose of 500 micrograms/kg. Atropine was given as a 2-mg bolus. In addition, five patients who received no drug infusions acted as controls, undergoing four serial signal-averaging studies in the baseline state: a 'baseline' study, and then three additional studies at time intervals similar to those incurred by the study patients. Therefore, a total of 21 TD and 21 STM tests were done in the study group (seven patients; three drugs per patient) during the drug infusions, and 15 TD and 15 STM tests were done in the control group (five patients; three 'nonbaseline' tests per patient). A change (normal to abnormal, or vice versa) in TD during a drug infusion occurred in 24% of the tests. No such change occurred in the control group (P < 0.01). A change in STM during a drug infusion occurred in 38% of tests, versus 13% of tests in the control group (P = 0.14). Overall, six of seven patients had a change in TD and/or STM diagnosis with infusion of one or more of the study drugs.(ABSTRACT TRUNCATED AT 250 WORDS)
PMID: 1279625
ISSN: 0147-8389
CID: 13392
HEART-RATE-VARIABILITY CORRELATES WITH THE ELECTROCARDIOGRAPHIC QT INTERVAL IN A HEALTHY POPULATION [Meeting Abstract]
DEMAZUMDER, D; SCHWARTZMAN, D; GLICKSTEIN, J; CHINITZ, L
ISI:A1992JQ52100053
ISSN: 0009-9279
CID: 51876
PERCUTANEOUS LEFT ATRIAL FEMORAL BYPASS FOR THE TREATMENT OF CARDIOGENIC-SHOCK
WINER, HE; GLASSMAN, E; SLATER, J; CHINITZ, LA; LEVITE, HA; RIBAKOVE, G
ISI:A1992JJ57900003
ISSN: 1042-3931
CID: 51906
Percutaneous mitral valvuloplasty following surgical repair of sinus venosus atrial septal defect [Case Report]
Gerber R; Sedlis SP; Tunick PA; Chinitz L; Altszuler H; Gindea A
Mitral valvuloplasty performed 5 y after repair of a sinus venosus ASD was difficult because of a thickened septum, but resulted in improved mitral valve opening and did not lead to ASD. Thus, prior repair of a sinus venosus ASD may not be an absolute contraindication to mitral valvuloplasty
PMID: 1889084
ISSN: 0098-6569
CID: 13949
Comparison of cardiac catheterization and Doppler echocardiography in the decision to operate in aortic and mitral valve disease [see comments] [Comment]
Slater J; Gindea AJ; Freedberg RS; Chinitz LA; Tunick PA; Rosenzweig BP; Winer HE; Goldfarb A; Perez JL; Glassman E; et al
Clinical decisions utilizing either Doppler echocardiographic or cardiac catheterization data were compared in adult patients with isolated or combined aortic and mitral valve disease. A clinical decision to operate, not operate or remain uncertain was made by experienced cardiologists given either Doppler echocardiographic or cardiac catheterization data. A prospective evaluation was performed on 189 consecutive patients (mean age 67 years) with valvular heart disease who were being considered for surgical treatment on the basis of clinical information. All patients underwent cardiac catheterization and detailed Doppler echocardiographic examination. Three sets of two cardiologist decision makers who did not know patient identity were given clinical information in combination with either Doppler echocardiographic or cardiac catheterization data. The combination of Doppler echocardiographic and clinical data was considered inadequate for clinical decision making in 21% of patients with aortic and 5% of patients with mitral valve disease. The combination of cardiac catheterization and clinical data was considered inadequate in 2% of patients with aortic and 2% of patients with mitral valve disease. Among the remaining patients, the cardiologists using echocardiographic or angiographic data were in agreement on the decision to operate or not operate in 113 (76% overall). When the data were analyzed by specific valve lesion, decisions based on Doppler echocardiography or catheterization were in agreement in 92%, 90%, 83% and 69%, respectively, of patients with aortic regurgitation, mitral stenosis, aortic stenosis and mitral regurgitation. Differences in cardiac output determination, estimation of valvular regurgitation and information concerning coronary anatomy were the main reasons for different clinical management decisions. These results suggest that for most adult patients with aortic or mitral valve disease, alone or in combination, Doppler echocardiographic data enable the clinician to make the same decision reached with catheterization data
PMID: 2007699
ISSN: 0735-1097
CID: 14079
Echocardiographic and hemodynamic characteristics of atrial septal defects created by percutaneous valvuloplasty
Kronzon I; Tunick PA; Goldfarb A; Freedberg RS; Chinitz L; Slater J; Schwinger ME; Gindea AJ; Glassman E; Daniel WG
Twenty-nine patients were studied by pulsed, continuous wave, and color Doppler before and after percutaneous transseptal valvuloplasty. New atrial septal defects were detected in 14 patients, and the patients were monitored for up to 320 days after the procedure. The diameter of the defect, best evaluated by the transesophageal approach, was 3 to 15 mm. A narrow, high velocity (1.4 to 3.1 meters per second) left-to-right shunt jet was detected in 13 of 14 patients. The shunt jet was continuous in nine of 14 patients, late systolic-holodiastolic in four patients, and bidirectional in one patient. Cardiac catheterization in nine patients confirmed the Doppler findings and demonstrated a peak pressure gradient of 10 to 32 mm Hg between the left and right atria. Oximetry revealed a calculated pulmonary to systemic flow ratio ranging from 2.3:1 in the patient with the largest atrial septal defect by echocardiography to 1:1 (no oxygen saturation step-up) in the patient with the smallest atrial septal defect. In the three patients who underwent cardiac surgery, the operative findings confirmed those of echocardiography. We concluded that atrial septal defects are common after transseptal valvuloplasty. Usually, their relatively small size and the underlying valvular disease that produces high left atrial pressure are responsible for the high pressure gradient between the left and right atria. This results in the high velocity and continuous shunt jet detected by Doppler echocardiography
PMID: 2310594
ISSN: 0894-7317
CID: 63046
High flow velocity across a complicated atrial septal defect: Doppler findings and hemodynamic correlations [Case Report]
Goldfarb A; Chinitz LA; Kronzon I
An unusually high atrial shunt flow velocity pattern was recorded in a patient whose atrial septal defect was created iatrogenically during a transatrial septal approach to aortic valvuloplasty. The flow velocity pattern measured by Doppler echocardiography was predictive of the high transatrial pressure gradient noted later at catheterization
PMID: 3272784
ISSN: 0894-7317
CID: 10967
Total occlusion of the abdominal aorta in a patient with Takayasu's arteritis: the importance of lower rib notching in the differential diagnosis [Case Report]
Chinitz, L A; Kronzon, I; Trehan, N; Kang, J G
PMID: 2880669
ISSN: 0098-6569
CID: 100119
Acquired immune deficiency syndrome possibly related to transfusion in an adult without known disease-risk factors [Case Report]
Gordon SM; Valentine FT; Holzman RS; Holliday RA; Baggott B; Chinitz LA; Brick PD
PMID: 6736676
ISSN: 0022-1899
CID: 15513