Searched for: person:lw901
Characterization and in vivo evaluation of laser sintered dental endosseous implants in dogs
Witek, Lukasz; Marin, Charles; Granato, Rodrigo; Bonfante, Estevam A; Campos, Felipe; Bisinotto, Julio; Suzuki, Marcelo; Coelho, Paulo G
Laser metal sintering has shown promising results, but no comparison with other commercially available surface has been performed. This study sought to evaluate the biomechanical and histological early bone response to laser sintered implants relative to alumina-blasted/acid-etched (AB/AE). Surface topography was characterized by scanning electron microscopy and optical interferometry. Surface chemistry was assessed by x-ray photoelectron spectroscopy. Beagle dogs (n = 18) received 4 Ti-6Al-4V implants (one per surface) in each radius, remaining for 1, 3, and 6 weeks (n = 6 dogs per evaluation time) in vivo. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated. Biomechanical evaluation comprised torque-to-interface failure. The laser sintered surface presented higher S(a) and S(q) than AB/AE. Chemistry assessment showed the alloy metallic components along with adsorbed carbon species. Significantly higher torque was observed at 1 (p < 0.02) and 6 week (p < 0.02) for the laser sintered, whereas at 3 week no significant differences were observed. Significantly higher BIC and BAFO was observed for the Laser Sintered (p < 0.04, and p < 0.03, respectively) only at 1 week, whereas no significant differences were observed at 3 and 6 weeks. The laser sintered implants presented biocompatible and osseoconductive properties and improved biomechanical response compared with the AB/AE surface only at 1 and 6 weeks in vivo.
PMID: 22692877
ISSN: 1552-4973
CID: 461902
Argon-based atmospheric pressure plasma enhances early bone response to rough titanium surfaces
Coelho, Paulo G; Giro, Gabriela; Teixeira, Hellen S; Marin, Charles; Witek, Lukas; Thompson, Van P; Tovar, Nick; Silva, Nelson R F A
This study investigated the effect of an Argon-based atmospheric pressure plasma (APP) surface treatment operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: rough titanium surface (Ti) and rough titanium surface + Argon-based APP (Ti-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received two plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ti, C, and O for the Ti and Ti- Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (C-C, C-H) with lower levels of oxidized carbon forms. The Ti-Plasma presented large increase in the Ti (+11%) and O (+16%) elements for the Ti- Plasma group along with a decrease of 23% in surface-adsorbed C content. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC (>300%) and mean BAFO (>30%) were observed for Ti-Plasma treated surfaces. From a morphologic standpoint, improved interaction between connective tissue was observed at 1 week, likely leading to more uniform and higher bone formation at 3 weeks for the Ti-Plasma treated implants was observed.
PMID: 22492543
ISSN: 1549-3296
CID: 461942
Expression patterns of kinin-dependent genes in endometrial cancer
Orchel, Joanna; Witek, Lukasz; Kimsa, Malgorzata; Strzalka-Mrozik, Barbara; Kimsa, Magdalena; Olejek, Anita; Mazurek, Urszula
OBJECTIVE: The present study has focused on the identification of the differences between expression patterns of kinin-dependent genes in endometrial cancer with the use of real-time quantitative reverse transcription polymerase chain reaction and oligonucleotide microarray. MATERIALS AND METHODS: The study group consisted of 50 endometrium samples collected from women with endometrial cancer. Gene expression of kinin receptors BR1 and BR2 was evaluated with real-time quantitative reverse transcription polymerase chain reaction. The analysis of the expression profile of genes related to the kinin mitogenic signal transduction pathway was performed using HG-U133A oligonucleotide microarrays. RESULTS: The transcriptional activity of the B1 receptor for kinins increased in patients with grade 1 (G1) and grade 2 (G2) endometrial cancer when compared to the control group, whereas it decreased in patients with grade 3 (G3) endometrial cancer. The expression of the B2 receptor showed a growing trend reaching the peak in the G2, whereas G3 was characterized by a decrease in the gene transcriptional activity. Significant differential gene expression was recorded for GNB1, PRKAR1A, KRAS, MAP2K2, GNG5, MAPK1, ADCY9, GNG11, JUN, PRKCA, PRKACB, FOS, PLCB4, ADCY8, and GNG12. CONCLUSION: The expression changes in kinin-dependent genes might cause disturbance in the underlying biological processes, which could be important for the pathogenesis of endometrial cancer. This will eventually help to improve treatment strategies for patients with endometrial cancer in the future.
PMID: 22706224
ISSN: 1525-1438
CID: 2654862
Assessment of a chair-side argon-based non-thermal plasma treatment on the surface characteristics and integration of dental implants with textured surfaces
Teixeira, Hellen S; Marin, Charles; Witek, Lukasz; Freitas, Amilcar Jr; Silva, Nelson R F; Lilin, Thomas; Tovar, Nick; Janal, Malvin N; Coelho, Paulo G
The biomechanical effects of a non-thermal plasma (NTP) treatment, suitable for use in a dental office, on the surface character and integration of a textured dental implant surface in a beagle dog model were evaluated. The experiment compared a control treatment, which presented an alumina-blasted/acid-etched (AB/AE) surface, to two experimental treatments, in which the same AB/AE surface also received NTP treatment for a period of 20 or 60 s per implant quadrant (PLASMA 20' and PLASMA 60' groups, respectively). The surface of each specimen was characterized by electron microscopy and optical interferometry, and surface energy and surface chemistry were determined prior to and after plasma treatment. Two implants of each type were then placed at six bilateral locations in 6 dogs, and allowed to heal for 2 or 4 weeks. Following sacrifice, removal torque was evaluated as a function of animal, implant surface and time in vivo in a mixed model ANOVA. Compared to the CONTROL group, PLASMA 20' and 60' groups presented substantially higher surface energy levels, lower amounts of adsorbed C species and significantly higher torque levels (p=.001). Result indicated that the NTP treatment increased the surface energy and the biomechanical fixation of textured-surface dental implants at early times in vivo.
PMID: 22498282
ISSN: 1878-0180
CID: 164450
Effect of Si addition on Ca- and P-impregnated implant surfaces with nanometer-scale roughness: an experimental study in dogs
Coelho, PG; Granato, R; Marin, C; Jimbo, R; Lin, S; Witek, L; Suzuki, M; Bonfante, EA
Objectives: To investigate the effect of Si addition on a nanometer-scale roughness Ca and P implant surfaces in a canine tibia model by biomechanical and histomorphometric evaluations. Material and methods: The implant surfaces comprised a resorbable media CaP microblasted (control) and a CaP resorbable media+silica-boost microblasted (experimental) surfaces. Surfaces were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and optical interferometry (IFM) down to the nanometric level. The animal model involved the bilateral placement of control (n=24) and experimental surface (n=24) implants along the proximal tibiae of six dogs, remaining in vivo for 2 or 4 weeks. After euthanization, half of the specimens were torqued-to-interface failure, and the other half was subjected to histomorphologic and bone-to-implant contact (BIC) evaluation. Torque and BIC statistical evaluation was performed by the Friedman test at 95% level of significance, and comparisons between groups was performed by the Dunn test. Results: IFM and SEM observations depicted comparable roughness parameters for both implant surfaces on the micrometer and nanometer scales. XPS analysis revealed similar chemical composition, except for the addition of Si on the experimental group. Torque-to-interface failure and BIC mean values showed no significant differences (P=0.25 and 0.51, respectively) at both 2- and 4-week evaluation points for experimental and control groups. Early bone healing histomorphologic events were similar between groups. Conclusions: The experimental surface resulted in not significantly different biomechanical fixation and BIC relative to control. Both surfaces were biocompatible and osseoconductive. To cite this article: Coelho PG, Granato R, Marin C, Jimbo R, Lin S, Witek L, Suzuki M, Bonfante EA. Effect of Si addition on Ca- and P-impregnated implant surfaces with nanometer-scale roughness: an experimental study in dogs. Clin. Oral Impl. Res. 23, 2012; 373-378. doi: 10.1111/j.1600-0501.2010.02150.x.
PMID: 21435014
ISSN: 0905-7161
CID: 160237
Effect of drilling dimension on implant placement torque and early osseointegration stages: an experimental study in dogs
Campos, Felipe E; Gomes, Julio B; Marin, Charles; Teixeira, Hellen S; Suzuki, Marcelo; Witek, Lukasz; Zanetta-Barbosa, Darceny; Coelho, Paulo G
PURPOSE: Primary stability has been regarded as a key factor to ensure uneventful osseointegration of dental implants. Such stability is often achieved by placing implants in undersized drilled bone. The present study evaluated the effect of drilling dimensions in insertion torque and early implant osseointegration stages in a beagle dog model. MATERIALS AND METHODS: Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before death. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in diameter. The insertion torque was recorded for all samples. After death, the implants in bone were nondecalcified processed and morphologically and morphometrically (bone-to-implant contact and bone area fraction occupancy) evaluated. Statistical analyses were performed using the Kruskal-Wallis test followed by Dunn's post hoc test for multiple comparisons at the 95% level of significance. RESULTS: The insertion torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2-mm and 3.8-mm groups (P = .003). Despite a significant increase in the bone-to-implant contact over time in vivo for all groups (P = .007), no effect for the drilling dimension was observed. Additionally, no effect of the drilling dimension and time was observed for the bone area fraction occupancy parameter (P = .31). The initial healing pathways differed between implants placed in bone drilled to different dimensions. CONCLUSIONS: Although different degrees of torque were observed with different drilling dimensions and these resulted in different healing patterns, no differences in the histometrically evaluated parameters were observed.
PMID: 22182660
ISSN: 0278-2391
CID: 160697
Bone Morphometric Evaluation around Immediately Placed Implants Covered with Porcine-Derived Pericardium Membrane: An Experimental Study in Dogs
Jimbo, Ryo; Marin, Charles; Witek, Lukasz; Suzuki, Marcelo; Tovar, Nick; Chesnoiu-Matei, Ioana; Dragan, Irina Florentina; Coelho, Paulo G
Objective. To investigate whether porcine-derived bioresorbable pericardium membrane coverage enhances the osseointegration around implants placed in fresh extraction sockets. Study Design. Twenty-four commercially available endosseous implants were placed in the fresh extraction sockets of the mandibular first molar of mature beagles (n = 6). On one side, implants and osteotomy sites were covered with porcine-derived bioresorbable pericardium membranes, whereas on the other side, no membranes were used. After 6 weeks, samples were retrieved and were histologically processed for histomorphometric analysis. Results. The histological observation showed that bone loss and soft tissue migration in the coronal region of the implant were evident for the control group, whereas bone fill was evident up to the neck of the implant for the membrane-covered group. Bone-to-implant contact was significantly higher for the membrane-covered group compared to the control group, 75% and 45% (P < 0.02), respectively. Conclusion. The experimental membranes proved to regenerate bone around implants placed in fresh extraction sockets without soft tissue intrusion.
PMCID:3512292
PMID: 23227052
ISSN: 1687-8787
CID: 461912
Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
Bonfante, Estevam A; Witek, Lukasz; Tovar, Nick; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Coelho, Paulo G
Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo. Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results. Significantly, higher S(a) (P < 0.03) and S(q) (P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion. Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants.
PMCID:3434399
PMID: 22969806
ISSN: 1687-8787
CID: 461932
Interval cranioplasty: comparison of current standards
Sultan, Steven M; Davidson, Edward H; Butala, Parag; Schachar, Jeffrey S; Witek, Lukasz; Szpalski, Caroline; Ricci, Jack L; Saadeh, Pierre B; Warren, Stephen M
BACKGROUND: Although different cranioplasty storage methods are currently in use, no study has prospectively compared these methods. The authors compare freezing and subcutaneous storage methods in a rat model. METHODS: Trephine defects (10 mm) were created in 45 Sprague-Dawley rats. The cranial bone grafts were stored in an autologous subcutaneous pocket (n = 15), frozen at -80 degrees C (n = 15), immediately analyzed (n = 12), or immediately replanted into the defect (n = 3). After 10 days of storage, the subcutaneous or frozen grafts were either replanted (subcutaneous, n = 3; frozen, n = 3) or analyzed (subcutaneous, n = 12; frozen, n = 12). Grafts underwent histologic analysis, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, alkaline phosphatase assay, mechanical testing, and micro-computed tomographic imaging. RESULTS: After 10 days of storage, physiologic assays demonstrated a significant decrease in cellular functionality (e.g., alkaline phosphatase assay concentration: fresh, 18.8 +/- 0.77 mM/mg; subcutaneous, 12.2 +/- 0.63 mM/mg; frozen, 8.07 +/- 1.1 mM/mg; p < 0.012 for all comparisons). Mechanical integrity (maximal load) of fresh grafts was greatest (fresh, 9.26 +/- 0.29 N; subcutaneous, 6.27 +/- 0.64 N; frozen, 4.65 +/- 0.29 N; fresh compared with frozen, p < 0.001; fresh compared with subcutaneous, p = 0.006). Replantation of subcutaneously stored and frozen grafts resulted in limited bony union and considerable resorption after 12 weeks; in contrast, replanted fresh grafts demonstrated bony union and little resorption. CONCLUSIONS: Current preservation methods for interval cranioplasty do not maintain bone graft viability. Subcutaneous storage appears to provide a small advantage compared with freezing.
PMID: 21532415
ISSN: 1529-4242
CID: 156286
Characterization of five different implant surfaces and their effect on osseointegration: a study in dogs
Coelho, Paulo G; Bonfante, Estevam A; Pessoa, Roberto S; Marin, Charles; Granato, Rodrigo; Giro, Gabriela; Witek, Lukasz; Suzuki, Marcelo
BACKGROUND: Chemical modification of implant surface is typically associated with surface topographic alterations that may affect early osseointegration. This study investigates the effects of controlled surface alterations in early osseointegration in an animal model. METHODS: Five implant surfaces were evaluated: 1) alumina-blasting, 2) biologic blasting, 3) plasma, 4) microblasted resorbable blasting media (microblasted RBM), and 5) alumina-blasting/acid-etched (AB/AE). Surface topography was characterized by scanning electron microscopy and optical interferometry, and chemical assessment by x-ray photoelectron spectroscopy. The implants were placed in the radius of six dogs, remaining 2 and 4 weeks in vivo. After euthanization, specimens were torqued-to-interface failure and non-decalcified-processed for histomorphologic bone-implant contact, and bone area fraction-occupied evaluation. Statistical evaluation was performed by one-way analysis of variance (P <0.05) and post hoc testing by the Tukey test. RESULTS: The alumina-blasting surface presented the highest average surface roughness and mean root square of the surface values, the biologic blasting the lowest, and AB/AE an intermediate value. The remaining surfaces presented intermediate values between the biologic blasting and AB/AE. The x-ray photoelectron spectroscopy spectra revealed calcium and phosphorus for the biologic blasting and microblasted RBM surfaces, and the highest oxygen levels for the plasma, microblasted RBM, and AB/AE surfaces. Significantly higher torque was observed at 2 weeks for the microblasted RBM surface (P <0.04), but no differences existed between surfaces at 4 weeks (P >0.74). No significant differences in bone-implant contact and bone area fraction-occupied values were observed at 2 and 4 weeks. CONCLUSION: The five surfaces were osteoconductive and resulted in high degrees of osseointegration and biomechanical fixation.
PMID: 21054223
ISSN: 0022-3492
CID: 160708