Surface characterization, biomechanical, and histologic evaluation of alumina and bioactive resorbable blasting textured surfaces in titanium implant healing chambers: an experimental study in dogs
Witek, Lukasz; Marin, Charles; Granato, Rodrigo; Bonfante, Estevam A; Campos, Felipe E B; Gomes, Julio Bisinotto; Suzuki, Marcelo; Coelho, Paulo G
PURPOSE: The present study was conducted to determine whether biomechanical and histologic parameters would differ between implant surfaces blasted with bioactive ceramic resorbable media (biologic blasting) and blasted with alumina and acid-etched. MATERIALS AND METHODS: Fourteen beagle dogs were used. Eight animals received two implants of each surface per limb, and each limb provided samples that remained in vivo for 3 and 6 weeks. The other six animals received two implants of each surface in one limb, which remained in vivo for 1 week. After euthanization, half of the implants were subjected to torque-to-interface fracture; the other half of the implants were processed for nondecalcified histology to calculate bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed with the Kruskal-Wallis test (95% level of significance). RESULTS: While no significant differences were observed for BIC and BAFO between surfaces at all three times in vivo and for torque levels at 1 and 3 weeks, a significantly higher torque was observed for the biologic blasting group after 6 weeks in vivo. Bone morphology was similar between groups at all times. CONCLUSION: A significant increase in early biomechanical fixation was observed for implants with the biologic blasting surface. However, no significant differences were observed for BIC and BAFO at any observation point.
PMID: 23748299
ISSN: 0882-2786
CID: 461992
Osseointegration assessment of chairside argon-based nonthermal plasma-treated Ca-P coated dental implants
Giro, Gabriela; Tovar, Nick; Witek, Lukasz; Marin, Charles; Silva, Nelson R F; Bonfante, Estevam A; Coelho, Paulo G
This study investigated the effect of an Argon-based nonthermal plasma (NTP) surface treatment-operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: Calcium-Phosphate (CaP) and CaP + NTP (CaP-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received 2 plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ca, C, O, and P for the CaP and CaP-Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (CC, CH) with lower levels of oxidized carbon forms. The CaP surface presented atomic percent values of 38, 42, 11, and 7 for C, O, Ca, and P, respectively, and the CaP-Plasma presented increases in O, Ca, and P atomic percent levels at 53, 12, and 13, respectively, in addition to a decrease in C content at 18 atomic percent. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC and BAFO were observed for CaP-Plasma treated surfaces. Surface elemental chemistry was modified by the Ar-based NTP. Ar-based NTP improved bone formation around plateau-root form implants at 3 weeks compared with CaP treatment alone. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A:98-103, 2013.
PMID: 22826209
ISSN: 1549-3296
CID: 208102
Expression patterns of kinin-dependent genes in endometrial cancer
Orchel, Joanna; Witek, Lukasz; Kimsa, Malgorzata; Strzalka-Mrozik, Barbara; Kimsa, Magdalena; Olejek, Anita; Mazurek, Urszula
OBJECTIVE: The present study has focused on the identification of the differences between expression patterns of kinin-dependent genes in endometrial cancer with the use of real-time quantitative reverse transcription polymerase chain reaction and oligonucleotide microarray. MATERIALS AND METHODS: The study group consisted of 50 endometrium samples collected from women with endometrial cancer. Gene expression of kinin receptors BR1 and BR2 was evaluated with real-time quantitative reverse transcription polymerase chain reaction. The analysis of the expression profile of genes related to the kinin mitogenic signal transduction pathway was performed using HG-U133A oligonucleotide microarrays. RESULTS: The transcriptional activity of the B1 receptor for kinins increased in patients with grade 1 (G1) and grade 2 (G2) endometrial cancer when compared to the control group, whereas it decreased in patients with grade 3 (G3) endometrial cancer. The expression of the B2 receptor showed a growing trend reaching the peak in the G2, whereas G3 was characterized by a decrease in the gene transcriptional activity. Significant differential gene expression was recorded for GNB1, PRKAR1A, KRAS, MAP2K2, GNG5, MAPK1, ADCY9, GNG11, JUN, PRKCA, PRKACB, FOS, PLCB4, ADCY8, and GNG12. CONCLUSION: The expression changes in kinin-dependent genes might cause disturbance in the underlying biological processes, which could be important for the pathogenesis of endometrial cancer. This will eventually help to improve treatment strategies for patients with endometrial cancer in the future.
PMID: 22706224
ISSN: 1525-1438
CID: 2654862
Characterization and in vivo evaluation of laser sintered dental endosseous implants in dogs
Witek, Lukasz; Marin, Charles; Granato, Rodrigo; Bonfante, Estevam A; Campos, Felipe; Bisinotto, Julio; Suzuki, Marcelo; Coelho, Paulo G
Laser metal sintering has shown promising results, but no comparison with other commercially available surface has been performed. This study sought to evaluate the biomechanical and histological early bone response to laser sintered implants relative to alumina-blasted/acid-etched (AB/AE). Surface topography was characterized by scanning electron microscopy and optical interferometry. Surface chemistry was assessed by x-ray photoelectron spectroscopy. Beagle dogs (n = 18) received 4 Ti-6Al-4V implants (one per surface) in each radius, remaining for 1, 3, and 6 weeks (n = 6 dogs per evaluation time) in vivo. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated. Biomechanical evaluation comprised torque-to-interface failure. The laser sintered surface presented higher S(a) and S(q) than AB/AE. Chemistry assessment showed the alloy metallic components along with adsorbed carbon species. Significantly higher torque was observed at 1 (p < 0.02) and 6 week (p < 0.02) for the laser sintered, whereas at 3 week no significant differences were observed. Significantly higher BIC and BAFO was observed for the Laser Sintered (p < 0.04, and p < 0.03, respectively) only at 1 week, whereas no significant differences were observed at 3 and 6 weeks. The laser sintered implants presented biocompatible and osseoconductive properties and improved biomechanical response compared with the AB/AE surface only at 1 and 6 weeks in vivo.
PMID: 22692877
ISSN: 1552-4973
CID: 461902
Bone Morphometric Evaluation around Immediately Placed Implants Covered with Porcine-Derived Pericardium Membrane: An Experimental Study in Dogs
Jimbo, Ryo; Marin, Charles; Witek, Lukasz; Suzuki, Marcelo; Tovar, Nick; Chesnoiu-Matei, Ioana; Dragan, Irina Florentina; Coelho, Paulo G
Objective. To investigate whether porcine-derived bioresorbable pericardium membrane coverage enhances the osseointegration around implants placed in fresh extraction sockets. Study Design. Twenty-four commercially available endosseous implants were placed in the fresh extraction sockets of the mandibular first molar of mature beagles (n = 6). On one side, implants and osteotomy sites were covered with porcine-derived bioresorbable pericardium membranes, whereas on the other side, no membranes were used. After 6 weeks, samples were retrieved and were histologically processed for histomorphometric analysis. Results. The histological observation showed that bone loss and soft tissue migration in the coronal region of the implant were evident for the control group, whereas bone fill was evident up to the neck of the implant for the membrane-covered group. Bone-to-implant contact was significantly higher for the membrane-covered group compared to the control group, 75% and 45% (P < 0.02), respectively. Conclusion. The experimental membranes proved to regenerate bone around implants placed in fresh extraction sockets without soft tissue intrusion.
PMCID:3512292
PMID: 23227052
ISSN: 1687-8787
CID: 461912
Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
Bonfante, Estevam A; Witek, Lukasz; Tovar, Nick; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Coelho, Paulo G
Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo. Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results. Significantly, higher S(a) (P < 0.03) and S(q) (P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion. Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants.
PMCID:3434399
PMID: 22969806
ISSN: 1687-8787
CID: 461932
Argon-based atmospheric pressure plasma enhances early bone response to rough titanium surfaces
Coelho, Paulo G; Giro, Gabriela; Teixeira, Hellen S; Marin, Charles; Witek, Lukas; Thompson, Van P; Tovar, Nick; Silva, Nelson R F A
This study investigated the effect of an Argon-based atmospheric pressure plasma (APP) surface treatment operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: rough titanium surface (Ti) and rough titanium surface + Argon-based APP (Ti-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received two plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ti, C, and O for the Ti and Ti- Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (C-C, C-H) with lower levels of oxidized carbon forms. The Ti-Plasma presented large increase in the Ti (+11%) and O (+16%) elements for the Ti- Plasma group along with a decrease of 23% in surface-adsorbed C content. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC (>300%) and mean BAFO (>30%) were observed for Ti-Plasma treated surfaces. From a morphologic standpoint, improved interaction between connective tissue was observed at 1 week, likely leading to more uniform and higher bone formation at 3 weeks for the Ti-Plasma treated implants was observed.
PMID: 22492543
ISSN: 1549-3296
CID: 461942
Histologic and biomechanical evaluation of alumina-blasted/acid-etched and resorbable blasting media surfaces
Bonfante, Estevam A; Marin, Charles; Granato, Rodrigo; Suzuki, Marcelo; Hjerppe, Jenni; Witek, Lukasz; Coelho, Paulo G
This study evaluated the early biomechanical fixation and bone-to-implant contact (BIC) of an alumina-blasted/acid-etched (AB/AE) compared with an experimental resorbable blasting media (RBM) surface in a canine model. Higher texturization was observed for the RBM than for the AB/AE surface, and the presence of calcium and phosphorus was only observed for the RBM surface. Time in vivo and implant surface did not influence torque. For both surfaces, BIC significantly increased from 2 to 4 weeks.
PMID: 20925518
ISSN: 0160-6972
CID: 184402
Abutment Design for Implant-Supported Indirect Composite Molar Crowns: Reliability and Fractography
Bonfante, EA; Suzuki, M; Lubelski, W; Thompson, VP; Carvalho, RM; Witek, L; Coelho, PG
Purpose: To investigate the reliability of titanium abutments veneered with indirect composites for implant-supported crowns and the possibility to trace back the fracture origin by qualitative fractographic analysis. Materials and Methods: Large base (LB) (6.4-mm diameter base, with a 4-mm high cone in the center for composite retention), small base (SB-4) (5.2-mm base, 4-mm high cone), and small base with cone shortened to 2 mm (SB-2) Ti abutments were used. Each abutment received incremental layers of indirect resin composite until completing the anatomy of a maxillary molar crown. Step-stress accelerated-life fatigue testing (n = 18 each) was performed in water. Weibull curves with use stress of 200 N for 50,000 and 100,000 cycles were calculated. Probability Weibull plots examined the differences between groups. Specimens were inspected in light-polarized and scanning electron microscopes for fractographic analysis. Results: Use level probability Weibull plots showed Beta values of 0.27 for LB, 0.32 for SB-4, and 0.26 for SB-2, indicating that failures were not influenced by fatigue and damage accumulation. The data replotted as Weibull distribution showed no significant difference in the characteristic strengths between LB (794 N) and SB-4 abutments (836 N), which were both significantly higher than SB-2 (601 N). Failure mode was cohesive within the composite for all groups. Fractographic markings showed that failures initiated at the indentation area and propagated toward the margins of cohesively failed composite. Conclusions: Reliability was not influenced by abutment design. Qualitative fractographic analysis of the failed indirect composite was feasible.
PMID: 22672650
ISSN: 1059-941x
CID: 169264
Assessment of a chair-side argon-based non-thermal plasma treatment on the surface characteristics and integration of dental implants with textured surfaces
Teixeira, Hellen S; Marin, Charles; Witek, Lukasz; Freitas, Amilcar Jr; Silva, Nelson R F; Lilin, Thomas; Tovar, Nick; Janal, Malvin N; Coelho, Paulo G
The biomechanical effects of a non-thermal plasma (NTP) treatment, suitable for use in a dental office, on the surface character and integration of a textured dental implant surface in a beagle dog model were evaluated. The experiment compared a control treatment, which presented an alumina-blasted/acid-etched (AB/AE) surface, to two experimental treatments, in which the same AB/AE surface also received NTP treatment for a period of 20 or 60 s per implant quadrant (PLASMA 20' and PLASMA 60' groups, respectively). The surface of each specimen was characterized by electron microscopy and optical interferometry, and surface energy and surface chemistry were determined prior to and after plasma treatment. Two implants of each type were then placed at six bilateral locations in 6 dogs, and allowed to heal for 2 or 4 weeks. Following sacrifice, removal torque was evaluated as a function of animal, implant surface and time in vivo in a mixed model ANOVA. Compared to the CONTROL group, PLASMA 20' and 60' groups presented substantially higher surface energy levels, lower amounts of adsorbed C species and significantly higher torque levels (p=.001). Result indicated that the NTP treatment increased the surface energy and the biomechanical fixation of textured-surface dental implants at early times in vivo.
PMID: 22498282
ISSN: 1878-0180
CID: 164450