Searched for: person:levinj04
Medial Sural Artery Musculocutaneous Perforator (MSAP) Flap for Reconstruction of Pharyngoesophageal Defects
Taufique, Zahrah M; Daar, David A; Levine, Jamie P; Jacobson, Adam S
We describe the use of the medial sural artery musculocutaneous perforator (MSAP) flap at our institution. It is a relatively new flap, originally described in 2001 for lower extremity defects, that has become increasingly popular for head and neck reconstruction due to its versatility, thinness, pliability, long pedicle, and particularly favorable donor site. It has been described for reconstruction of oral defects, but there is little published on its use in pharyngeal reconstruction. We suggest that the MSAP is an ideal flap for addressing defects caused by pharyngoesophageal stenosis, pharyngeal fistulas, or laryngopharyngectomies. We review 5 cases at our institution from June 2016 to November 2017.
PMID: 32393106
ISSN: 1097-6817
CID: 4437982
Does Laterality of Lower Extremity Donor Site Affect Outcomes in Microvascular Soft Tissue Lower Extremity Reconstruction?
Yu, Jason W; Rifkin, William J; Lee, Z-Hye; Borab, Zachary; Alfonso, Allyson R; Thanik, Vishal D; Levine, Jamie P
BACKGROUND: There are many different variables to consider in lower extremity microvascular soft tissue reconstruction including flap choice. Our aim is to objectively evaluate recipient complications related to lower extremity donor flap laterality. METHODS: A total of 77 lower extremity soft tissue reconstructions utilizing microvascular free tissue transfers for Gustilo type III between 1979 and 2016 were collected. We compared complication rates between ipsilateral and contralateral donor sites relative to the injured leg. The following parameters were analyzed: overall complications, total flap failure, partial flap failure, major complications, operative takebacks, and salvage rates. RESULTS: = 0.006). CONCLUSION/CONCLUSIONS: Although there is a higher risk of anastomotic thrombosis, particularly venous thrombosis, associated with ipsilateral donor-site group, there were no significant differences in complications or flap survival. Flaps can be harvested from a traumatized leg with acceptable complication rates while avoiding the morbidity of operating on an uninjured limb.
PMID: 31994158
ISSN: 1098-8947
CID: 4294172
Larger free flap size is associated with increased complications in lower extremity trauma reconstruction
Lee, Z-Hye; Abdou, Salma A; Ramly, Elie P; Daar, David A; Stranix, John T; Anzai, Lavinia; Saadeh, Pierre B; Levine, Jamie P; Thanik, Vishal D
BACKGROUND:Free flap reconstruction after lower extremity trauma remains challenging with various factors affecting overall success. Increasing defect and flap size have been demonstrated to be a surrogate for overall injury severity and correlated with complications. In addition, larger free flaps that encompass more tissue theoretically possess high metabolic demand, and may be more susceptible to ischemic insult. Therefore, the purpose of our study was to determine how flap size affects microsurgical outcomes in the setting of lower extremity trauma reconstruction. METHODS:. Partial flap failure, total flap failure, takebacks, and overall major complications (defined as events involving flap compromise) were compared between these two groups. Multivariate logistic regression was performed to determine whether flap size independently predicts complications and flap failures, controlling for injury-related and operative factors. RESULTS:, use of muscle flaps was associated with significantly increased flap failure rates (p = .008) while for smaller flap size, there was no significant difference in complications between muscle and fasciocutaneous flaps. CONCLUSION/CONCLUSIONS:was associated with significantly increased flap failure and complications particularly among muscle-based flaps. Therefore, we suggest that fasciocutaneous flaps be utilized for injuries requiring large surface area of soft tissue reconstruction.
PMID: 31912944
ISSN: 1098-2752
CID: 4257362
Free Tissue Transfer with Distraction Osteogenesis and Masquelet Technique Is Effective for Limb Salvage in Patients with Gustilo Type IIIB Open Fractures
Abdou, Salma A; Stranix, John T; Daar, David A; Mehta, Devan D; McLaurin, Toni; Tejwani, Nirmal; Saadeh, Pierre B; Levine, Jamie P; Leucht, Philipp; Thanik, Vishal D
Osteocutaneous reconstruction can be challenging because of concomitant injuries and limited donor sites. There is a paucity of data on limb salvage outcomes following combined soft-tissue reconstruction and bone transport or Masquelet procedures. The authors reviewed a consecutive series of open tibia fracture patients undergoing soft-tissue reconstruction with either distraction osteogenesis or Masquelet technique. Endpoints were perioperative flap complications and bone union. Fourteen patients with Gustilo type IIIB open tibia fractures were included. Half of the group received muscle flaps and the remaining half received fasciocutaneous flaps. Ten patients (71.4 percent) underwent distraction osteogenesis and the remaining patients underwent Masquelet technique. Average bone gap length was 65.7 ± 31.3 mm (range, 20 to 120 mm). In the bone transport group, the average external fixation duration was 245 days (range, 47 to 686 days). In the Masquelet group, the average duration of the first stage of this two-stage procedure (i.e., time from cement spacer placement to bone grafting) was 95 days (range, 42 to 181 days). Bone union rate, as determined by radiographic evidence, was 85.7 percent. There was one complete flap failure (7.1 percent). One patient underwent below-knee amputation after failing bone transport and developing chronic osteomyelitis and subsequent infected nonunion. Our case series demonstrates that nonosteocutaneous flap methods of limb reconstruction are a viable option in patients with segmental long bone defects, with a bone union rate of 85 percent and a limb salvage rate over 90 percent in patients with Gustilo type IIIB fractures. CLINICAL QUESTION/LEVEL OF EVIDENCE:: Therapeutic, IV.
PMID: 32221236
ISSN: 1529-4242
CID: 4369902
Robotically Assisted Omentum Flap Harvest: A Novel, Minimally Invasive Approach for Vascularized Lymph Node Transfer
Frey, Jordan D; Yu, Jason W; Cohen, Steven M; Zhao, Lee C; Choi, Mihye; Levine, Jamie P
Background/UNASSIGNED:The omentum provides abundant lymphatic tissue with reliable vascular anatomy, representing an ideal donor for vascularized lymph node transfer without risk for donor site lymphedema. We describe a novel, robotically assisted approach for omental flap harvest. Methods/UNASSIGNED:All patients undergoing robotically assisted omentum harvest for vascularized lymph node transfer from 2017 to 2019 were identified. Patient demographics, intraoperative variables, and postoperative outcomes were reviewed. Results/UNASSIGNED:, respectively. Indications for lymph node transfer were upper extremity lymphedema following mastectomy, radiation, and lymphadenectomy (60.0%); congenital unilateral lower extremity lymphedema (20.0%); and bilateral lower extremity/scrotal lymphedema following partial penectomy and bilateral inguinal/pelvic lymphadenectomy (20.0%). Four patients (80.0%) underwent standard robotic harvest, whereas 1 patient underwent single-port robotic harvest. The average number of port sites was 4.4. All patients underwent omentum flap transfer to 2 sites; in 2 cases, the flap was conjoined, and in 3 cases, the flap was segmented. The average overall operative time was 9:19. The average inpatient hospitalization was 5.2 days. Two patients experienced cellulitis, which is resolved with oral antibiotics. There were no major complications. All patients reported subjective improvement in swelling and softness of the affected extremity. The average follow-up was 8.8 months. Conclusions/UNASSIGNED:Robotically assisted omental harvest for vascularized lymph node transfer is a novel, safe, and viable minimally invasive approach offering improved intra-abdominal visibility and maneuverability for flap dissection.
PMCID:7209865
PMID: 32440389
ISSN: 2169-7574
CID: 4447032
Simultaneous Ventral Hernia Repair and Panniculectomy: A Systematic Review and Meta-Analysis of Outcomes
Sosin, Michael; Termanini, Kareem M; Black, Cara K; Thanik, Vishal; Saadeh, Pierre B; Levine, Jamie P
BACKGROUND:Simultaneous ventral hernia repair and panniculectomy (SVHRP) is a procedure that is more commonly being offered to patients with excess skin and subcutaneous tissue in need of a ventral hernia repair; however, there are concerns about surgical-site complications and uncertainty regarding the durability of repair. SVHRP outcomes vary within the literature. This study assessed the durability, complication profile, and safety of SVHRP through a large data-driven repository of SVHRP cases.360 METHODS:: The current SVHRP literature was queried using the MEDLINE, PubMed, and Cochrane databases. Predefined selection criteria resulted in 76 relevant titles yielding 16 articles for analysis. Meta-analysis was used to analyze primary outcomes, identified as surgical-site occurrence and hernia recurrence. Secondary outcomes included review of techniques used and systemic complications, which were analyzed with pooled weighted mean analysis from the collected data. RESULTS:There were 917 patients who underwent an SVHRP (mean age, 52.2 ± 7.0 years; mean body mass index, 36.1 ± 5.8 kg/m; mean pannus weight, 3.2 kg). The mean surgical-site occurrence rate was 27.9 percent (95 percent CI, 15.6 to 40.2 percent; I = 70.9 percent) and the mean hernia recurrence rate was 4.9 percent (95 percent CI, 2.4 to 7.3 percent; I = 70.1 percent). Mean follow-up was 17.8 ± 7.7 months. The most common complications were superficial surgical-site infection (15.8 percent) and seroma formation (11.2 percent). Systemic complications were less common (7.8 percent), with a thromboembolic event rate of 1.2 percent. The overall mortality rate was 0.4 percent. CONCLUSIONS:SVHRP is associated with a high rate of surgical-site occurrence, but surgical-site infection seems to be less prominent than previously anticipated. The low hernia recurrence rate and the safety of this procedure support its current implementation in abdominal wall reconstruction.
PMID: 32221233
ISSN: 1529-4242
CID: 4371182
Evolution of the Surgical Technique for "Breast in a Day" Direct-to-Implant Breast Reconstruction: Transitioning from Dual-Plane to Prepectoral Implant Placement
Frey, Jordan D; Salibian, Ara A; Levine, Jamie P; Karp, Nolan S; Choi, Mihye
PMID: 32097340
ISSN: 1529-4242
CID: 4324282
The Rich Get Richer: Osseous Chimeric Versatility to the Anterolateral Thigh Flap
Yu, Jason W; Frey, Jordan D; Thanik, Vishal D; Rodriguez, Eduardo D; Levine, Jamie P
BACKGROUND: The lateral femoral circumflex artery (LFCA) system, which supplies the anterolateral thigh (ALT) flap territory, offers a plethora of tissue types for composite, functional reconstruction. However, the ability to include a reliable and flexible osseous component is limited. Based on cadaveric dissections, we describe an isolated LFCA branch to the femur separate from the vastus intermedius that can be included in ALT flap harvest in cases requiring bony reconstruction. METHODS: Cadaveric dissection was undertaken to define the LFCA vascular system with specific dissection of the proximal branches of the descending branch of the LFCA (db-LFCA) to define any muscular, periosteal, and/or osseous branches to the femur. RESULTS: Six thighs in four cadavers were dissected. Consistent in all specimens, there was an isolated branch extending distally, medially, and posteriorly from the proximal LFCA and entering the periosteum of the femur. In five specimens, the identified branch to the femur was located approximately 1-cm distal to the rectus femoris branch of the LFCA and approximately 1-cm proximal to a separate branch entering and supplying the vastus intermedius. In one specimen, there was a common trunk. The length of this branch from the origin at the LFCA to insertion into the femoral periosteum was approximately 6 to 8 cm. CONCLUSION/CONCLUSIONS: There appears to be a consistent and reliable branch to the femur based on the proximal LFCA that may be included in ALT flap harvest, adding even more versatility, as another option in complex cases requiring composite reconstruction, including bone.
PMID: 31652481
ISSN: 1098-8947
CID: 4163112
The Decline of Head and Neck Reconstruction in Plastic Surgery: Where Do We Go from Here?
Lee, Z-Hye; Daar, David A; Jacobson, Adam S; Levine, Jamie P
PMID: 31985694
ISSN: 1529-4242
CID: 4293902
Alexis Retractor: Institutional Experience of Its Applications in Head and Neck Surgery and Review of the Literature
Lee, Jasmine; Yu, Jason W; Lee, Z-Hye; Levine, Jamie P; Jacobson, Adam S
BACKGROUND/UNASSIGNED:The Alexis retractor is a device that provides simultaneous radial retraction and wound protection during surgical procedures. Although typically used in abdominal and pelvic surgeries, there has been increased development of novel operative techniques utilizing the Alexis retractors in head and neck surgeries. METHODS/UNASSIGNED:We describe 2 cases of utilizing the Alexis retractor to attain transoral exposure in the setting of free flap reconstruction of intraoral defects. RESULTS/UNASSIGNED:In both cases, the Alexis retractor provided improved retraction, decreasing the number of instruments required for adequate exposure. Additionally, the polyurethane sheath component acted as a protective membrane over the lips and mucosa. CONCLUSIONS/UNASSIGNED:The Alexis retractor can be a powerful retraction tool for certain surgical procedures involving the head and neck regions.
PMID: 31960710
ISSN: 1545-1569
CID: 4273842