Searched for: person:avr6
A Predictive Model for Root Caries Incidence
Ritter, André V; Preisser, John S; Puranik, Chaitanya P; Chung, Yunro; Bader, James D; Shugars, Daniel A; Makhija, Sonia; Vollmer, William M
This study aimed to find the set of risk indicators best able to predict root caries (RC) incidence in caries-active adults utilizing data from the Xylitol for Adult Caries Trial (X-ACT). Five logistic regression models were compared with respect to their predictive performance for incident RC using data from placebo-control participants with exposed root surfaces at baseline and from two study centers with ancillary data collection (n = 155). Prediction performance was assessed from baseline variables and after including ancillary variables [smoking, diet, use of removable partial dentures (RPD), toothbrush use, income, education, and dental insurance]. A sensitivity analysis added treatment to the models for both the control and treatment participants (n = 301) to predict RC for the control participants. Forty-nine percent of the control participants had incident RC. The model including the number of follow-up years at risk, the number of root surfaces at risk, RC index, gender, race, age, and smoking resulted in the best prediction performance, having the highest AUC and lowest Brier score. The sensitivity analysis supported the primary analysis and gave slightly better performance summary measures. The set of risk indicators best able to predict RC incidence included an increased number of root surfaces at risk and increased RC index at baseline, followed by white race and nonsmoking, which were strong nonsignificant predictors. Gender, age, and increased number of follow-up years at risk, while included in the model, were also not statistically significant. The inclusion of health, diet, RPD use, toothbrush use, income, education, and dental insurance variables did not improve the prediction performance.
PMID: 27160516
ISSN: 1421-976x
CID: 4143992
The influence of two different curing regimens on light energy transmission through bulk-fill resin composites and Vickers hardness
de Vasconcellos, Adalberto B; Delgado, Alex; Hirata, Ronaldo; Blackmon, Richard; Swift, Edward J Jr; Heymann, Harald O; Oldenburg, Amy L; Ritter, Andre V
PURPOSE: To evaluate the presence and length of microcracks in resin-based materials finished with different techniques, using optical coherence tomography (OCT). METHODS: Standardized Class V preparations (3x2x2mm) were made in the facial and lingual surfaces of 20 recently-extracted human third molars. 20 preparations were restored with a resin-based composite material (RBC; Filtek Supreme Ultra) and the other 20 with a resin-modified glass-ionomer material (RMGI; Ketac Nano). After final polymerization, specimens were further stratified by finishing system: aluminum oxide discs (Sof-Lex) or spiral fluted carbide bur series (H48L). By random allocation, each extracted tooth therefore received one RBC and one RMGI restoration, and equal numbers of restorations from each material were finished using each finishing system (n= 10). After 24 hours of storage in 100% humidity at room temperature, the specimens were evaluated at x20 to x600 under environmental SEM. Cross-sectional occlusal-cervical B-mode images were obtained in increments of 25 mm from the mesial margin to the distal margin of the restoration using a spectral-domain (SD) OCT system and analyzed using Image J software to identify and measure microcrack penetration into each restoration. The total length (mm) at the point of the deepest microcrack penetration in each specimen was recorded. Data were statistically analyzed using a t-test. RESULTS: No microcracks were observed in the RBC samples. However, microcrack presence was identified in all of the RMGI specimens. The t-test showed a statistically significant difference (P< 0.05) in mean microcrack length values based on the finishing technique used for the RMGI samples. [SofLex: 0.67 (+/- 0.28) mm; carbide: 1.26 (+/- 0.30)] mm. Two-way ANOVA showed significant differences in the factors "finishing technique" and "restorative material" (P< 0.001). The interaction of these two factors was also statistically significant (P< 0.001). For the tested RMGI, Tukey post-hoc test revealed that the finishing with aluminum oxide groups resulted in statistically significant lower mean microcrack length when compared to spiral fluted carbide burs (P< 0.001). CLINICAL SIGNIFICANCE: Resin-modified glass-ionomer (RMGI) is more susceptible to microcrack presence than resin-based composites. Also, aluminum oxide discs produced lower values of mean microcrack length than spiral fluted carbide burs after the finishing procedure of RMGI restorations.
PMID: 29178744
ISSN: 0894-8275
CID: 2797772
Eighteen-month clinical evaluation of a two-component self-etch adhesive [Meeting Abstract]
Ritter, Andre V; Heymann, HO; Swift, EJ; Sturdevant, J; Boushell, LW; Lambert, C
ORIGINAL:0014365
ISSN: 0022-0345
CID: 4154952
Effect of composite type and placement technique on shrinkage stress [Meeting Abstract]
Olafsson, VG; Ritter, Andre V; Swift, EJ; Boushell, LW; Ko, C; Donovan, TE
ORIGINAL:0014370
ISSN: 0022-0345
CID: 4155002
Etching and water storage affect self-etch porcelain repair systems [Meeting Abstract]
Guha, U; Ritter, Andre V; Parker, J; Swift, EJ; Donovan, T
ORIGINAL:0014369
ISSN: 0022-0345
CID: 4154992
Assessment of patient and provider satisfaction of different dental isolation methods [Meeting Abstract]
Ahmed, S; Erickson, K; Ritter, Andre V
ORIGINAL:0014366
ISSN: 0022-0345
CID: 4154962
Cross-sectional visualization of microcracks in resin-based materials by optical coherence tomography [Meeting Abstract]
Vasconcellos, AB; Hirata, R; Blackmon, R; Swift, EJ; Heymann, H; Delgado, AH; Oldenburg, AL; Ritter, Andre V
ORIGINAL:0014368
ISSN: 0022-0345
CID: 4154982
Optical properties and light irradiance of monolithic zirconia at variable thicknesses [Meeting Abstract]
Sulaiman, T; Abulmajeed, A; Donovan, T; Ritter, Andre V; Vallittu, P; Narhi, T; Lassila, L
ORIGINAL:0014367
ISSN: 0022-0345
CID: 4154972
Operative dentistry
Chapter by: Ritter, Andre V
in: Mosby's review for the NBDE : Part two by Dowd, Frank J (Ed)
St. Louis, Missouri : Elsevier, [2015]
pp. 35-78
ISBN: 0323225683
CID: 4151802
Degree of conversion of dual-polymerizing cements light polymerized through monolithic zirconia of different thicknesses and types
Sulaiman, Taiseer A; Abdulmajeed, Aous A; Donovan, Terrence E; Ritter, André V; Lassila, Lippo V; Vallittu, Pekka K; Närhi, Timo O
STATEMENT OF PROBLEM/BACKGROUND:Monolithic zirconia restorations are increasingly common. Dual-polymerizing cements have been advocated for cementation. The opacious nature of zirconia restoration can attenuate light, compromising optimal resin polymerization and eventually restoration debonding. PURPOSE/OBJECTIVE:The purpose of this in vitro study was to evaluate the influence of material thickness on light irradiance, radiant exposure, and the degree of monomer conversion (DC) of 2 dual-polymerizing resin cements light-polymerized through different brands of monolithic zirconia. MATERIAL AND METHODS/METHODS:Dual-polymerizing resin cements (RelyX Ultimate; 3M-ESPE, and Variolink II; Ivoclar, Vivadent) were mixed according to the manufacturers' instructions with a film thickness of 40 μm, placed under a 10 × 10 mm specimen of monolithic zirconia (Prettau Anterior by Zirkonzahn, Katana by Noritake, BruxZir by Glidewell, and Zenostar by Wieland) and a zirconia core control (ICE zirkon by Zirkonzahn) at various thicknesses (0.50, 1.00, 1.50, and 2.00 mm, n = 5 of each thickness). Each specimen was irradiated for 20 seconds (RelyX Ultimate) and 40 seconds (Variolink II) with Elipar S10 (3M-ESPE, 1200 mW/cm(2)). The amount of irradiance and radiant exposure was quantified for each specimen. Fourier transform infrared spectroscopy was used to measure the DC from the bottom surface of the resin. Statistical analysis was performed with 2-way ANOVA and post hoc Tukey honest significant difference (HSD) tests (α = .05). RESULTS:Light irradiance and radiant exposure decreased as the thickness of the specimen increased (P < .05) regardless of the brand. The ranking from least to highest was BruxZir < ICE zircon = Wieland < Katana = Prettau Anterior. The zirconia brand, thickness, and cement type had a significant effect on the DC (P < .001). The DC decreased significantly as the thickness of the zirconia increased (P < .001). Katana and Prettau Anterior showed the highest DC and BruxZir showed the lowest. CONCLUSION/CONCLUSIONS:The thickness of zirconia affects the DC of resin-based cements. The DC of the resin cements differed significantly between cements and among zirconia brands. More polymerizing time may be needed to deliver sufficient energy through some brands of zirconia.
PMID: 25882969
ISSN: 1097-6841
CID: 4143962