Searched for: school:SOM
Department/Unit:Otolaryngology
Postoperative imaging of the multichannel cochlear implant
Shpizner BA; Holliday RA; Roland JT; Cohen NL; Waltzman SB; Shapiro WH
PURPOSE: To present the postoperative radiographic appearance of the multichannel cochlear implant and to suggest criteria for the radiographic evaluation of postimplant patients. METHODS: One hundred forty-one patients, 73 female and 68 male, had multichannel cochlear implants inserted. One hundred thirty-five intraoperative radiographs, 31 postoperative radiographic examinations, and 10 postoperative CT examinations were retrospectively reviewed. RESULTS: In 135 patients, a Stenver's or anteroposterior projection confirmed the normal placement of the implant by demonstrating the electrodes to be regularly spaced and gently curved within the first turn of the cochlea. The insertion depth was determined by counting the number of electrodes that projected medial to the cochlear promontory. In 5 patients in whom intracochlear placement of the electrode array could not be confirmed on plain radiographs, CT demonstrated the location of the electrode array. In 3 patients with postoperative infections, CT either correctly identified or excluded the presence of a collection beneath the implant. CONCLUSION: Plain radiographs of the temporal bone are sufficient for the postoperative treatment of the majority of postimplant patients. CT should be performed when plain radiographs cannot adequately show the location of the electrode array or if postoperative infection is suspected
PMID: 7484646
ISSN: 0195-6108
CID: 6867
Determination of robust ocular pharmacokinetic parameters in serum and vitreous humor of albino rabbits following systemic administration of ciprofloxacin from sparse data sets by using IT2S, a population pharmacokinetic modeling program
Drusano, G L; Liu, W; Perkins, R; Madu, A; Madu, C; Mayers, M; Miller, M H
Robust determination of the concentration-time profile of anti-infective agents in certain specialized compartments is often limited by the inability to obtain more than a single sample from such a site in any one subject. Vitreous humor and cerebrospinal fluid are obvious examples for which the determination of concentrations of anti-infective agents is limited. Advances in pharmacodynamics have pointed out the importance of understanding the profiles of drugs in the plasma and in specialized compartments in order to dose the drugs to obtain the best patient outcomes. Advances in population pharmacokinetic modeling hold the promise of allowing proper estimation of drug penetration into the vitreous (or other specialized compartment) with only a single vitreous sample, in conjunction with plasma sampling. We have developed a rabbit model which allows multiple samples of vitreous to be obtained without breaking down the blood-vitreous barrier. We have employed this model to test the hypothesis that robust estimates of vitreous penetration by the fluoroquinolone ciprofloxacin can be obtained from a traditional intensive plasma sampling set plus a single vitreous sample. We studied 33 rabbits which were receiving 40 mg of ciprofloxacin per kg of body weight intravenously as short infusions and from which multiple plasma and vitreous samples were obtained and assayed for ciprofloxacin content by high-performance liquid chromatography. Data were analyzed by the iterative two-stage population modeling technique (IT2S), employing the iterative two-stage program of Forrest et al. (Antimicrob. Agents Chemother. 37:1065-1072, 1993). Two data sets were analyzed: all plasma and vitreous samples versus all plasma samples and the initially obtained single vitreous sample. The pharmacokinetic parameter values identified were used to calculate the percent vitreous penetration as the ratio of the area under the concentration-time curve for the vitreous to that for the plasma. The values identified, 4% penetration for the full data set versus 3% penetration for the single vitreous sample data set, and their corresponding estimates were not statistically significantly different. We conclude that population modeling holds promise for the analysis of penetration of antimicrobiol agents into specialized spaces from which only single samples can be obtained, particularly for patients with whom robust plasma sampling can be performed.
PMCID:162807
PMID: 7486900
ISSN: 0066-4804
CID: 2793502
Clinical use of a frameless stereotactic arm: results of 325 cases [Case Report]
Golfinos JG; Fitzpatrick BC; Smith LR; Spetzler RF
The viewing wand is a frameless stereotactic arm that can be used in conjunction with computerized tomography (CT) or magnetic resonance (MR) imaging to provide image-based intraoperative navigation. The authors report a series of 325 cases in which the viewing wand was used and evaluated for its utility, ease of integration into the standard surgical setup, reliability, and real-world accuracy. The use of the system was associated with minimal additional effort or time spent in setting up the procedure as long as a trained technician performed the data transfer and reconstruction. The viewing wand was used in 165 cases in conjunction with CT and 145 cases with MR imaging. The system was reliable, achieving a useful registration in 310 of 325 cases (95.4%). Fiducial-based registration was more accurate than an anatomical landmark-surface fit algorithm method of registration (mean 2.8 vs. 5.6 mm error, respectively, for CT; and mean 3.0 vs. 6.2 mm for MR imaging). The actual error of the system in estimating the position of the probe tip just after registration was judged by the operating surgeon to be less than 2 mm in 92% of MR imaging cases and in 82% of CT cases, between 2 and 5 mm in 7% of MR imaging and 17% of CT cases, and greater than 5 mm in less than 1% of MR imaging and 1.2% of CT cases. The accuracy of the system degraded during the operation, so that by the third evaluation the error was estimated to be less than 2 mm in 77% of MR imaging and 62% of CT cases. Overall, the viewing wand was found to be reliable and accurate. This real-world accuracy was sufficient for a broad range of applications including glioma resection, cerebrospinal fluid shunting procedures, resection of small subcortical masses, and temporal lobe resection. The system is a useful navigational aid that allows a direct approach to intracranial pathology without the drawbacks of application and the limitations of a stereotactic frame
PMID: 7616261
ISSN: 0022-3085
CID: 42029
Metastatic basal cell carcinoma of the head and neck [Case Report]
Tavin E; Persky MS; Jacobs J
Metastases are occasionally associated with cutaneous squamous cell carcinoma but only rarely with basal cell carcinoma. There are approximately 200 cases of metastases from basal cell carcinoma reported in the world literature. We describe 6 additional cases. All of our patients demonstrated recurrence at the primary site before they developed their metastases. Metastases presented in subcutaneous tissue, cervical lymph nodes, bone, and lung between 1.5 and 14 years after initial treatment of the primary lesion. The long interval seen in these patients between the initial treatment of the primary and the development of metastases underscores the need for long-term follow-up in what is often thought to be a nonaggressive, nonmetastasizing malignancy
PMID: 7630292
ISSN: 0023-852x
CID: 6870
Preferred listening levels for linear and slow-acting compression hearing aids
Neuman AC; Bakke MH; Hellman S; Levitt H
OBJECTIVE: The purpose of the present experiment was to determine the relationship between most comfortable listening level and preferred listening levels for linear and slow-acting compression hearing aids as a function of variations in speech and noise level. DESIGN: A digital hearing aid test system was used to simulate six hearing aids having compression ratios of 1, 1.5, 2, 3, 5, and 10:1. Speech was presented in three different noises (vent, apartment, and cafeteria), with speech input level being varied (55, 70, 85 dB SPL). Subjects were 20 listeners with sensorineural hearing loss (half with a dynamic range < or = 30 dB and half with a dynamic range >30 dB). The boundaries of the most comfortable listening range were measured to estimate most comfortable listening level. Preferred listening level was measured by having subjects adjust the output of the hearing aid for satisfactory listening. RESULTS: On average, the deviation of preferred listening level from most comfortable loudness (MCL) was less than 5 dB. Dynamic range, noise type, and input level were all found to have small, but significant, effects on the deviation of preferred listening level from MCL. On average, subjects with a small dynamic range listened slightly below MCL, and subjects with a larger dynamic range listened slightly above MCL. For favorable signal-to-noise ratios, preferred listening levels were highest for high input levels and for conditions that resulted in high output levels before level adjustment. Although the pattern of average performance differed slightly at poorer signal-to-noise ratios, all preferred listening levels were close to MCL. CONCLUSIONS: The gain of a slow-acting compression hearing aid should place the output within 5 dB of MCL. The output for low and medium inputs should approximate MCL and the output for high input levels should be slightly above MCL. This pattern of gain may be obtained with mild compression ratios and a gain rule that places a speech input of 70 dB at MCL
PMID: 8549896
ISSN: 0196-0202
CID: 58934
Non-Hodgkin's lymphoma of the external auditory canal in an HIV-positive patient [Case Report]
Kieserman, S P; Finn, D G
This is a case report of non-Hodgkin's lymphoma of the external auditory canal, and infratemporal fossa, which presented with multiple cranial nerve palsies. The diagnosis was achieved via biopsy of tissue from the external auditory canal, and treatment with radiation therapy led to improvement of the symptoms. The management of AIDS-related lymphoma of the skull base with cranial neuropathies is reviewed.
PMID: 7561500
ISSN: 0022-2151
CID: 2077262
Chronic hemoptysis: an unusual manifestation of fungal sinusitis [Case Report]
Fiero, R A; Groth, M; Hurewitz, A; April, M; Nuovo, M
A woman with chronic hemoptysis as her only complaint had extensive testing and did not respond to antibiotic therapy. Radiologic examination of the sinuses identified a mass which, on surgical exploration, was found to be the result of a fungus, Pseudallescheria boydii. Although this fungus is known to be a cause of epistaxis, this is the first instance in which it has been reported to cause hemoptysis.
PMID: 7597490
ISSN: 0038-4348
CID: 2348322
Exercise-induced laryngomalacia [Case Report]
Smith RJ; Bauman NM; Bent JP; Kramer M; Smits WL; Ahrens RC
Exercise-induced laryngomalacia (EIL) is characterized by severe dyspnea, stridor, and mild wheezing unresponsive to prophylactic treatment with beta-agonists and cromolyn sodium. Symptoms develop with extreme exertion, but resolve quickly as the degree of exercise is decreased. Diagnosis requires flexible fiberoptic laryngoscopy before, during, and after exercise. If the diagnosis of EIL is confirmed by laryngoscopy during maximal exercise, laser epiglottoplasty is effective in alleviating symptoms and improving the airway. However, because symptoms develop only during maximal exertion, EIL is unlikely to produce symptoms or functional disability in persons who lead relatively sedentary lives
PMID: 7598366
ISSN: 0003-4894
CID: 27086
Current trends in pediatric tracheotomy
Ward RF; Jones J; Carew JF
A retrospective analysis was performed on 103 pediatric patients, less than 5 years of age, undergoing tracheotomy at New York Hospital between 1980 and 1990. Charts were reviewed with respect to primary diagnosis, indication for tracheotomy, duration of the tracheotomy, complication rate and mortality rate. Approximately 62% of the tracheotomies were performed in patients less than 12 months of age, with the most common indication being an acquired or congenital airway abnormality. The number of patients receiving tracheotomies for neurological disorders, however, increased more than threefold over the course of this review. Approximately one-third of the patients experienced immediate, early or delayed complications. There was a significant correlation between the complication rate and weight at the time of the tracheotomy as well as the degree of prematurity of the child. Over one half of the infants under 2000 g suffered complications. A mortality rate of 2.9% was noted in our study with mucous plugging of the tracheotomy being the most common etiology of death
PMID: 7665270
ISSN: 0165-5876
CID: 27204
Pharmacokinetics of ofloxacin in serum and vitreous humor of albino and pigmented rabbits
Perkins, R J; Liu, W; Drusano, G; Madu, A; Mayers, M; Madu, C; Miller, M H
The purpose of this study was to evaluate the pharmacokinetics of ofloxacin in serum and vitreous humor samples from albino and pigmented rabbits by using a recently described animal model which permits robust estimation of parameter values. The drug was administered to rabbits intravenously, multiple vitreous humor and serum samples were taken from each rabbit, and the vitreous humor and serum samples were assayed by high-pressure liquid chromatography. The pharmacokinetic parameters were determined with RSTRIP, an iterative, nonlinear, weighted, least-squares regression program. Eight New Zealand White rabbits and eight Dutch Belted rabbits (split into single-dose and multiple-dose groups) were investigated in this study. The value of penetration into the vitreous humor of albino rabbits (n = 6) was 32.6% +/- 2.12%, with terminal-elimination half-life values of 3.21 and 2.39 h, respectively, for vitreous humor and serum. In pigmented rabbits after a single dose (n = 3) and with a steady-state concentration of drug in serum (n = 4), penetration values were similar, at 30.4% +/- 2.98% and 30.0% +/- 4.12%, respectively (P > 0.10). Following a single dose of ofloxacin, pigmented animals had elimination half-life values from serum and vitreous humor of 2.64 and 4.32 h, respectively. After steady state was achieved, half-life values for serum and vitreous humor were 3.12 and 6.05 h, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
PMCID:162769
PMID: 7492092
ISSN: 0066-4804
CID: 2793512