Try a new search

Format these results:

Searched for:

person:jtm13

Total Results:

264


Nano-bio-chip sensor platform for examination of oral exfoliative cytology

Weigum, Shannon E; Floriano, Pierre N; Redding, Spencer W; Yeh, Chih-Ko; Westbrook, Stephen D; McGuff, H Stan; Lin, Alan; Miller, Frank R; Villarreal, Fred; Rowan, Stephanie D; Vigneswaran, Nadarajah; Williams, Michelle D; McDevitt, John T
Oral cancer is a deadly and disfiguring disease that could greatly benefit from new diagnostic approaches enabling early detection. In this pilot study, we describe a nano-bio-chip (NBC) sensor technique for analysis of oral cancer biomarkers in exfoliative cytology specimens, targeting both biochemical and morphologic changes associated with early oral tumorigenesis. Here, oral lesions from 41 dental patients, along with normal epithelium from 11 healthy volunteers, were sampled using a noninvasive brush biopsy technique. Specimens were enriched, immunolabeled, and imaged in the NBC sensor according to previously established assays for the epidermal growth factor receptor (EGFR) biomarker and cytomorphometry. A total of 51 measurement parameters were extracted using custom image analysis macros, including EGFR labeling intensity, cell and nuclear size, and the nuclear-to-cytoplasmic ratio. Four key parameters were significantly elevated in both dysplastic and malignant lesions relative to healthy oral epithelium, including the nuclear area and diameter (P < 0.0001), the nuclear-to-cytoplasmic ratio (P < 0.0001), and EGFR biomarker expression (P < 0.03). Further examination using logistic regression and receiver operating characteristic curve analyses identified morphologic features as the best predictors of disease (area under the curve < or =0.93) individually, whereas a combination of all features further enhanced discrimination of oral cancer and precancerous conditions (area under the curve, 0.94) with high sensitivity and specificity. Further clinical trials are necessary to validate the regression model and evaluate other potential biomarkers, but this pilot study supports the NBC sensor technique as a promising new diagnostic tool for early detection of oral cancer, which could enhance patient care and survival.
PMCID:2853714
PMID: 20332305
ISSN: 1940-6215
CID: 1390502

Programmable nano-bio-chip sensors: analytical meets clinical

Jokerst, Jesse V; Jacobson, James W; Bhagwandin, Bryon D; Floriano, Pierre N; Christodoulides, Nicolaos; McDevitt, John T
There have been many recent advances in the nano-bio-chip analysis methodology with implications for a number of high-morbidity diseases including HIV, cancer, and heart disease. (To listen to a podcast about this article, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html .).
PMCID:2853750
PMID: 20128622
ISSN: 0003-2700
CID: 1390512

Current developments in salivary diagnostics

Miller, Craig S; Foley, Joseph D; Bailey, Alison L; Campell, Charles L; Humphries, Roger L; Christodoulides, Nicolaos; Floriano, Pierre N; Simmons, Glennon; Bhagwandin, Bryon; Jacobson, James W; Redding, Spencer W; Ebersole, Jeffrey L; McDevitt, John T
Salivary diagnostics is an emerging field that has progressed through several important developments in the past decade, including the publication of the human salivary proteome and the infusion of federal funds to integrate nanotechnologies and microfluidic engineering concepts into developing compact point-of-care devices for rapid analysis of this secretion. In this article, we discuss some of these developments and their relevance to the prognosis, diagnosis and management of periodontitis, as an oral target, and cardiovascular disease, as a systemic example for the potential of these biodiagnostics. Our findings suggest that several biomarkers are associated with distinct biological stages of these diseases and demonstrate promise as practical biomarkers in identifying and managing periodontal disease, and acute myocardial infarction. The majority of these studies have progressed through biomarker discovery, with the identified molecules requiring more robust clinical studies to enable substantive validation for disease diagnosis. It is predicted that with continued advances in this field the use of a combination of biomarkers in multiplex panels is likely to yield accurate screening tools for these diagnoses in the near future.
PMCID:2857781
PMID: 20387312
ISSN: 1752-0363
CID: 1390522

Programmable nano-bio-chips: multifunctional clinical tools for use at the point-of-care

Jokerst, Jesse V; McDevitt, John T
A new generation of programmable diagnostic devices is needed to take advantage of information generated from the study of genomics, proteomics, metabolomics and glycomics. This report describes the 'programmable nano-bio-chip' with potential to bridge the significant scientific, technology and clinical gaps through the creation of a diagnostic platform to measure the molecules of life. This approach, with results at the point-of-care, possesses capabilities for measuring such diverse analyte classes as cells, proteins, DNA and small molecules in the same compact device. Applications such as disease diagnosis and prognosis for areas including cancer, heart disease and HIV are described. New diagnostic panels are inserted as 'plug and play' elements into the modular platform with universal assay operating systems and standard read out sequences. The nano-bio-chip ensemble exhibits excellent analytical performance and cost-effectiveness with extensive validation versus standard reference methods (R(2) = 0.95-0.99). This report describes the construction and use of two major classes of nano-bio-chip designs that serve as cellular and chemical processing units, and provides perspective on future growth in this newly emerging field of programmable nano-bio-chip sensor systems.
PMCID:3063103
PMID: 20025471
ISSN: 1743-5889
CID: 1390532

ANYL 15-Probing the analytical parameters of a nanobiochip immunoassay system for the detection of carcinoembryonic antigen [Meeting Abstract]

Pollard, Amanda A; McDevitt, John T
ISI:000207861901130
ISSN: 0065-7727
CID: 1408852

Nano-bio-chips for high performance multiplexed protein detection: determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels

Jokerst, Jesse V; Raamanathan, Archana; Christodoulides, Nicolaos; Floriano, Pierre N; Pollard, Amanda A; Simmons, Glennon W; Wong, Jorge; Gage, Carole; Furmaga, Wieslaw B; Redding, Spencer W; McDevitt, John T
The integration of semiconductor nanoparticle quantum dots (QDs) into a modular, microfluidic biosensor for the multiplexed quantitation of three important cancer markers, carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), and Her-2/Neu (C-erbB-2) was achieved. The functionality of the integrated sample processing, analyte capture and detection modalities was demonstrated using both serum and whole saliva specimens. Here, nano-bio-chips that employed a fluorescence transduction signal with QD-labeled detecting antibody were used in combination with antigen capture by a microporous agarose bead array supported within a microfluidics ensemble so as to complete the sandwich-type immunoassay. The utilization of QD probes in this miniaturized biosensor format resulted in signal amplification 30 times relative to that of standard molecular fluorophores as well as affording a reduction in observed limits of detection by nearly 2 orders of magnitude (0.02 ng/mL CEA; 0.11 pM CEA) relative to enzyme-linked immunosorbent assay (ELISA). Assay validation studies indicate that measurements by the nano-bio-chip system correlate to standard methods at R(2)=0.94 and R(2)=0.95 for saliva and serum, respectively. This integrated nano-bio-chip assay system, in tandem with next-generation fluorophores, promises to be a sensitive, multiplexed tool for important diagnostic and prognostic applications.
PMCID:2740498
PMID: 19576756
ISSN: 0956-5663
CID: 1390542

Use of saliva-based nano-biochip tests for acute myocardial infarction at the point of care: a feasibility study

Floriano, Pierre N; Christodoulides, Nicolaos; Miller, Craig S; Ebersole, Jeffrey L; Spertus, John; Rose, Beate G; Kinane, Denis F; Novak, M John; Steinhubl, Steven; Acosta, Shelley; Mohanty, Sanghamitra; Dharshan, Priya; Yeh, Chih-ko; Redding, Spencer; Furmaga, Wieslaw; McDevitt, John T
BACKGROUND: For adults with chest pain, the electrocardiogram (ECG) and measures of serum biomarkers are used to screen and diagnose myocardial necrosis. These measurements require time that can delay therapy and affect prognosis. Our objective was to investigate the feasibility and utility of saliva as an alternative diagnostic fluid for identifying biomarkers of acute myocardial infarction (AMI). METHODS: We used Luminex and lab-on-a-chip methods to assay 21 proteins in serum and unstimulated whole saliva procured from 41 AMI patients within 48 h of chest pain onset and from 43 apparently healthy controls. Data were analyzed by use of logistic regression and area under curve (AUC) for ROC analysis to evaluate the diagnostic utility of each biomarker, or combinations of biomarkers, in screening for AMI. RESULTS: Both established and novel cardiac biomarkers demonstrated significant differences in concentrations between patients with AMI and controls without AMI. The saliva-based biomarker panel of C-reactive protein, myoglobin, and myeloperoxidase exhibited significant diagnostic capability (AUC = 0.85, P < 0.0001) and in conjunction with ECG yielded strong screening capacity for AMI (AUC = 0.96) comparable to that of the panel (brain natriuretic peptide, troponin-I, creatine kinase-MB, myoglobin; AUC = 0.98) and far exceeded the screening capacity of ECG alone (AUC approximately 0.6). En route to translating these findings to clinical practice, we adapted these unstimulated whole saliva tests to a novel lab-on-a-chip platform for proof-of-principle screens for AMI. CONCLUSIONS: Complementary to ECG, saliva-based tests within lab-on-a-chip systems may provide a convenient and rapid screening method for cardiac events in prehospital stages for AMI patients.
PMID: 19556448
ISSN: 0009-9147
CID: 1390552

Lab-on-a-chip sensor for analysis of cellular biomarkers in oral exfoliative cytology: A new diagnostic tool for early detection of oral cancer [Meeting Abstract]

Weigum, SE; Redding, SW; Yeh, C; McGuff, HS; Vigneswaran, N; McDevitt, JT
ISI:000271015100206
ISSN: 1368-8375
CID: 1391082

Integration of semiconductor quantum dots into nano-bio-chip systems for enumeration of CD4+ T cell counts at the point-of-need

Jokerst, Jesse V; Floriano, Pierre N; Christodoulides, Nicolaos; Simmons, Glennon W; McDevitt, John T
Recent humanitarian efforts have led to the widespread release of antiretroviral drugs for the treatment of the more than 33 million HIV afflicted people living in resource-scarce settings. Here, the enumeration of CD4+ T lymphocytes is required to establish the level at which the immune system has been compromised. The gold standard method used in developed countries, based on flow cytometry, though widely accepted and accurate, is precluded from widespread use in resource-scarce settings due to its high expense, high technical requirements, difficulty in operation-maintenance and the lack of portability for these sophisticated laboratory-confined systems. As part of continuing efforts to develop practical diagnostic instrumentation, the integration of semiconductor nanocrystals (quantum dots, QDs) into a portable microfluidic-based lymphocyte capture and detection device is completed. This integrated system is capable of isolating and counting selected lymphocyte sub-populations (CD3+CD4+) from whole blood samples. By combining the unique optical properties of the QDs with the sample handling capabilities and cost effectiveness of novel microfluidic systems, a practical, portable lymphocyte measurement modality that correlates nicely with flow cytometry (R2 = 0.97) has been developed. This QD-based system reduces the optical requirements significantly relative to molecular fluorophores and the mini-CD4 counting device is projected to be suitable for use in both point-of-need and resource-scarce settings.
PMCID:2847472
PMID: 19023471
ISSN: 1473-0189
CID: 1390562

ANYL 149-Serum and saliva CEA determinations via fluorescent nanoparticles [Meeting Abstract]

Jokerst, Jesse V; Pollard, Amanda; McDevitt, John T
ISI:000271775100359
ISSN: 0065-7727
CID: 1408952