Try a new search

Format these results:

Searched for:

school:SOM

Department/Unit:Plastic Surgery

Total Results:

5759


Decreasing Opioid Prescriptions in Women Undergoing Mastectomy and Breast Reconstruction

Tedesco, Deborah; Mayo, James L
BACKGROUND:Florida enacted legislation limiting opioid prescriptions and affecting the management of acute pain in the postoperative patient. Patients in a reconstructive surgery practice were receiving prescriptions for opioids as their primary method of pain management. Clinic providers identified a need to limit opioid prescriptions. AIM/OBJECTIVE:The aim of this quality improvement initiative was to decrease the number of opioids prescribed while effectively managing pain in women undergoing mastectomy and breast tissue expander placement. DESIGN/METHODS:This is a quality improvement project. METHODS:The Model for Improvement was used as a framework for this project. An evidence-based pain management plan was developed after a review of the breast reconstruction surgery literature. The plan incorporated preoperative patient and family education and the standard use of preemptive analgesia, intraoperative nerve blocks, and postoperative multimodal analgesia in all patients undergoing mastectomy with breast tissue expander placement. Patient and family education and perioperative pain management were provided to patients, and the number of opioid tablets prescribed was tracked. RESULTS:Between January 2018 and August 2019, the average number of opioid tablets prescribed per patient decreased from 84.7 to 8.4. CONCLUSIONS:Opioid prescriptions can be decreased in women undergoing breast reconstruction with the use of patient education and multimodal analgesia.
PMID: 32280011
ISSN: 1532-8635
CID: 4518482

Reply: Does Staged Breast Reduction before Nipple-Sparing Mastectomy Decrease Complications? A Matched Cohort Study between Staged and Nonstaged Techniques [Comment]

Salibian, Ara A; Frey, Jordan D; Karp, Nolan S; Choi, Mihye
PMID: 32740610
ISSN: 1529-4242
CID: 4581232

In Response to "Regarding the MSAP Flap: A Better Option in Complex Head and Neck Reconstruction?" [Letter]

Daar, David A; Taufique, Zahrah M; Cohen, Leslie E; Thanik, Vishal D; Levine, Jamie P; Jacobson, Adam S
PMID: 32343418
ISSN: 1531-4995
CID: 4438502

Excuse me, but I have a question [Editorial]

Jerrold, Laurance
PMID: 32534796
ISSN: 1097-6752
CID: 4514722

In Reference to The Medial Sural Artery Perforator Flap: A Better Option in Complex Head and Neck Reconstruction? [Letter]

Silva, Amanda K; Portugal, Louis; Blair, Elizabeth A
PMID: 32343425
ISSN: 1531-4995
CID: 4494532

Plastic Surgery Chairs and Program Directors: Are the Qualifications Different for Men and Women?

Zhang, Ben; Chen, Kevin; Ha, Grace; Smith, Mark L; Bradley, James P; Thorne, Charles H; Kasabian, Armen K; Pusic, Andrea L; Tanna, Neil
BACKGROUND:The gender disparity between the number of female and male chairs and program directors has been previously established. The aim of this study was to determine whether any differences in objective credentials existed between male and female plastic surgery department chairs/division chiefs and program directors. METHODS:Information about each plastic surgery program director and chair/chief was extracted from the websites of all institutions affiliated with a plastic surgery residency program. For each individual, information about the length of their career, number of fellowships completed, and number of publications was recorded. The two-tailed t test was used to compare differences between male and female chairs and program directors. RESULTS:A total of 99 chairs were recorded, of which nine (9.1 percent) were female. Of the 99 program directors, 13 (13.1 percent) were female. There was no difference in the number of years in practice or number of fellowships between men and women for either position. On average, male chairs had significantly fewer publications than female chairs (71.9 versus 128; p < 0.05). There was no significant difference in the number of publications between male and female program directors. Compared to program directors, chairs had significantly more years in practice and numbers of publications, which held true for both men and women. CONCLUSIONS:Women are not only underrepresented in the department chair and program director positions, but also possess higher qualifications that may reflect differences in standards for promotion and appointment. Additional research is needed to elucidate the reasons behind the observed differences in qualifications.
PMID: 32740601
ISSN: 1529-4242
CID: 4553572

Obesity/Metabolic Syndrome and Diabetes Mellitus on Peri-implantitis

de Oliveira, Paula Gabriela Faciola Pessôa; Bonfante, Estevam A; Bergamo, Edmara T P; de Souza, Sérgio Luis Scombatti; Riella, Leonardo; Torroni, Andrea; Benalcazar Jalkh, Ernesto B; Witek, Lukasz; Lopez, Christopher D; Zambuzzi, Willian Fernando; Coelho, Paulo G
Literature has reported that up to 50% of dental implants may be affected by peri-implantitis, a bacteria-induced chronic inflammatory process, which promotes osteoclast-mediated bone resorption and inhibits bone formation, leading to progressive bone loss around implants. Current evidence points toward an increased risk for the development of peri-implantitis in both obesity/metabolic syndrome (MetS) and diabetes mellitus (DM) conditions relative to the healthy population. Currently, there is no effective treatment for peri-implantitis and the 50% prevalence in MetS and DM, along with its predicted increase in the worldwide population, presents a major concern in implant dentistry as hyperglycemic conditions are associated with bone-healing impairment; this may be through dysfunction of osteocalcin-induced glucose metabolism. The MetS/DM proinflammatory systemic condition and altered immune/microbiome response affect both catabolic and anabolic events of bone-healing that include increased osteoclastogenesis and compromised osteoblast activity, which could be explained by the dysfunction of insulin receptor that led to activation of signals related with osteoblast differentiation. Furthermore, chronic hyperglycemia along with associated micro- and macro-vascular ailments leads to delayed/impaired wound healing due to activation of pathways that are particularly important in initiating events linked to inflammation, oxidative stress, and cell apoptosis; this may be through deactivation of AKT/PKB protein, which possesses a pivotal role in drive survival and eNOS signaling. This review presents an overview of the local and systemic mechanisms synergistically affecting bone-healing impairment in MetS/DM individuals, as well as a rationale for hierarchical animal model selection, in an effort to characterize peri-implantitis disease and treatment.
PMID: 32591106
ISSN: 1879-3061
CID: 4510852

Anesthetic Considerations in Facial Transplantation: Experience at NYU Langone Health and Systematic Review

Alfonso, Allyson R; Ramly, Elie P; Kantar, Rami S; Rifkin, William J; Diaz-Siso, J Rodrigo; Gelb, Bruce E; Yeh, Joseph S; Espina, Mark F; Jain, Sudheer K; Piper, Greta L; Rodriguez, Eduardo D
Anesthetic considerations are integral to the success of facial transplantation (FT), yet limited evidence exists to guide quality improvement. This study presents an institutional anesthesia protocol, defines reported anesthetic considerations, and provides a comprehensive update to inform future directions of the field.
PMCID:7489595
PMID: 32983760
ISSN: 2169-7574
CID: 4616462

The Impact of COVID-19-based Suspension of Surgeries on Plastic Surgery Practices: A Survey of ACAPS Members

Sarac, Benjamin A; Schoenbrunner, Anna R; Wilson, Stelios C; Chiu, Ernest S; Janis, Jeffrey E
The coronavirus disease 2019 (COVID-19) pandemic led to a drastic decline in the number of elective surgeries performed in the United States. Many national societies and local governments provided recommendations for surgeons to initially suspend and progressively resume elective surgery. The authors used a survey to the American Council of Academic Plastic Surgeons (ACAPS) to assess the effect on plastic surgeons.
PMCID:7489607
PMID: 32983820
ISSN: 2169-7574
CID: 4651662

Effect of indenter material on reliability of all-ceramic crowns

Lorenzoni, Fabio C; Bonfante, Estevam A; Valverde, Guilherme B; Coelho, Paulo G; Bonfante, Gerson; Thompson, Van P; Silva, Nelson R F A
OBJECTIVES/OBJECTIVE:Controversy exists about whether the elastic modulus (E) mismatch between the loading indenter and ceramic materials influences fatigue testing results. The research hypotheses were that for porcelain veneered Y-TZP crowns 1) A low modulus Steatite indenter (SB) leads to higher fatigue reliability compared to a high modulus tungsten carbide indenter (WC); 2) Different surface damage patterns are expected between low and high modulus indenters after sliding contact fatigue testing. All ceramic crowns will exhibit similar step-stress accelerated life testing (SSALT) contact fatigue reliability (hypothesis 1) and failure characteristics (hypothesis 2) when using high stiffness tungsten carbide (WC, E = 600 GPa) vs. enamel like steatite (SB, E = 90 GPa) indenters. METHODS:Manufacturer (3M Oral Care) prepared Y-TZP-veneered all-ceramic molar crowns were bonded to aged resin composite reproductions of a standard tooth preparation and subjected to mouth-motion SSALT fatigue (n = 18 per indenter type). Failure was defined either as initial inner cone crack (IC), or final fracture (FF) when porcelain fractured (chipping). Selected IC specimens that did not progress to FF were embedded in epoxy resin and sectioned for fractographic analysis. RESULTS:The distribution of failures across the load and cycle profiles lead to similar calculated Weibull Use Level Probability Plots with overlap of the 2-sided 90% confidence bounds. The calculated reliability for IC and FF was equivalent at a mission of 300 N or 700 N load and 50,000 cycles, although the WC indenter had a trend for lower reliability for IC at 700 N. Both indenters produced similar patterns of wear and cracking on crown surfaces. Fractographic landmarks showed competing failure modes, but sliding contact partial inner cone cracks were the most dominant for both groups. SIGNIFICANCE/CONCLUSIONS:The more compliant Steatite indenter had similar veneered crown fatigue reliability and failure modes to those found with use of a high stiffness tungsten carbide indenter (hypotheses 1 and 2 rejected).
PMID: 32469725
ISSN: 1878-0180
CID: 4465712