Try a new search

Format these results:

Searched for:

person:lw901

Total Results:

178


"Bone Tissue Engineering in the Growing Calvaria: A 3D Printed Bioceramic Scaffold to Reconstruct Critical-Sized Defects in a Skeletally Immature Pig Model"

DeMitchell-Rodriguez, Evellyn M; Shen, Chen; Nayak, Vasudev V; Tovar, Nick; Witek, Lukasz; Torroni, Andrea; Yarholar, Lauren M; Cronstein, Bruce N; Flores, Roberto L; Coelho, Paulo G
BACKGROUND:3D-printed bioceramic scaffolds composed of 100% beta(β)-tricalcium phosphate augmented with dipyridamole (3DPBC-DIPY) can regenerate bone across critically sized defects in skeletally mature and immature animal models. Prior to human application, safe and effective bone formation should be demonstrated in a large translational animal model. This study evaluated the ability of 3DPBC-DIPY scaffolds to restore critically sized calvarial defects in a skeletally immature, growing minipig. METHODS:Unilateral calvarial defects (~1.4cm) were created in six-week-old Göttingen minipigs (n=12). Four defects were filled with a 1000µ M 3DPBC-DIPY scaffold with a cap (a solid barrier on the ectocortical side of the scaffold to prevent soft tissue infiltration), four defects were filled with a 1000µM 3DPBC-DIPY scaffold without a cap, and four defects served as negative controls (no scaffold). Animals were euthanized 12-weeks post-operatively. Calvaria were subjected to micro-computed tomography, 3D-reconstruction with volumetric analysis, qualitative histologic analysis, and nanoindentation. RESULTS:Scaffold-induced bone growth was statistically greater than negative controls (p≤0.001) and the scaffolds with caps produced significantly more bone generation compared to the scaffolds without caps (p≤0.001). Histological analysis revealed woven and lamellar bone with the presence of haversian canals throughout the regenerated bone. Additionally, cranial sutures were observed to be patent and there was no evidence of ectopic bone formation or excess inflammatory response. Reduced elastic modulus (Er) and hardness (H) of scaffold-regenerated bone were found to be statistically equivalent to native bone (p = 0.148 for Er of scaffolds with and without caps, and p = 0.228 and p = 0.902, for H of scaffolds with and without caps, respectively). CONCLUSION/CONCLUSIONS:3DPBC-DIPY scaffolds have the capacity to regenerate bone across critically sized calvarial defects in a skeletally immature translational pig model.
PMID: 36723712
ISSN: 1529-4242
CID: 5420092

Three-Dimensional Printing Bioceramic Scaffolds Using Direct-Ink-Writing for Craniomaxillofacial Bone Regeneration

Nayak, Vasudev Vivekanand; Slavin, Blaire V; Bergamo, Edmara T P; Torroni, Andrea; Runyan, Christopher M; Flores, Roberto L; Kasper, F Kurtis; Young, Simon; Coelho, Paulo G; Witek, Lukasz
Defects characterized as large osseous voids in bone, in certain circumstances, are difficult to treat, requiring extensive treatments which lead to an increased financial burden, pain, and prolonged hospital stays. Grafts exist to aid in bone tissue regeneration (BTR), among which ceramic-based grafts have become increasingly popular due to their biocompatibility and resorbability. BTR using bioceramic materials such as β-tricalcium phosphate has seen tremendous progress and has been extensively used in the fabrication of biomimetic scaffolds through the three-dimensional printing (3DP) workflow. 3DP has hence revolutionized BTR by offering unparalleled potential for the creation of complex, patient, and anatomic location-specific structures. More importantly, it has enabled the production of biomimetic scaffolds with porous structures that mimic the natural extracellular matrix while allowing for cell growth-a critical factor in determining the overall success of the BTR modality. While the concept of 3DP bioceramic bone tissue scaffolds for human applications is nascent, numerous studies have highlighted its potential in restoring both form and function of critically sized defects in a wide variety of translational models. In this review, we summarize these recent advancements and present a review of the engineering principles and methodologies that are vital for using 3DP technology for craniomaxillofacial reconstructive applications. Moreover, we highlight future advances in the field of dynamic 3D printed constructs via shape-memory effect, and comment on pharmacological manipulation and bioactive molecules required to treat a wider range of boney defects.
PMID: 37463403
ISSN: 1937-3392
CID: 5535642

In vitro analysis of durability of S-PRG filler-containing composite crowns for primary molar restoration

Nakase, Yutaro; Yamaguchi, Satoshi; Jalkh, Ernesto B Benalcázar; Atria, Pablo J; Witek, Lukasz; Bonfante, Estevam A; Li, Hefei; Sakai, Takahiko; Okawa, Rena; Nakano, Kazuhiko; Imazato, Satoshi
OBJECTIVE:To evaluate the reliability, maximum principal stress, shear stress, and crack initiation of a computer-aided design/computer-aided manufacturing (CAD/CAM) resin composite (RC) incorporating surface pre-reacted glass (S-PRG) filler for primary molar teeth. METHODS:Mandibular primary molar crowns fabricated by experimental (EB) or commercially available CAD/CAM RCs (HC) were prepared and cemented to a resinous abutment tooth using an adhesive resin cement (Cem) or a conventional glass-ionomer cement (CX). These specimens were subjected to a single compressive test (n = 5/each) and the step-stress accelerated life testing (SSALT) (n = 12/each). Data was evaluated using Weibull analyses and reliability was calculated. Afterwards, the maximum principal stress and crack initiation point of each crown was analyzed by finite element analysis. To evaluate bonding of EB and HC to dentin, microtensile bond strength (μTBS) testing was conducted using primary molar teeth (n = 10/each). RESULTS:There was no significant difference between the fracture loads of EB and HC for either cement (p > 0.05). The fracture loads of EB-CX and HC-CX were significantly lower than EB-Cem and HC-Cem (p < 0.05). The reliability at 600 N for EB-Cem was greater than that for EB-CX, HC-Cem, and HC-CX. The maximum principal stress concentrated on EB was lower than that on HC. The shear stress concentrated in the cement layer for EB-CX was higher than that for HC-CX. There was no significant difference among the μTBSs of EB-Cem, EB-CX, HC-Cem, and HC-CX (p > 0.05). SIGNIFICANCE/CONCLUSIONS:The crowns fabricated with the experimental CAD/CAM RC incorporating S-PRG filler yielded greater fracture loads and reliability than the crowns manufactured with commercially available CAD/CAM RC regardless of the luting materials. These findings suggest that the experimental CAD/CAM RC crown may be clinically useful for the restoration of primary molars.
PMID: 37208292
ISSN: 1879-0097
CID: 5538232

Manufacturing and characterization of a 3D printed lithium disilicate ceramic via robocasting: A pilot study

Abreu, João Luiz Bittencourt de; Hirata, Ronaldo; Witek, Lukasz; Benalcazar Jalkh, Ernesto Byron; Nayak, Vasudev Vivekanand; de Souza, Bruno Martins; Silva, Eduardo Moreira da
OBJECTIVE:) ceramic structures fabricated using additive manufacturing (3D printing). METHODS:powder was combined with ammonium polyacrylate, hydroxypropyl methylcellulose, and polyelectrolyte to create a colloidal gel, which was then used for printing. A digital CAD model of a disc was designed, and the G-code transferred to a custom built DIW 3D printer. The control group samples were prepared using pre-crystallized ceramic blocks, which were cut to obtain discs with same dimensions as the AR group. Disc-shaped specimens from both groups were crystallized at 840 °C. Mechanical properties were evaluated using biaxial flexural strength test (BFS) and Vickers hardness test. Representative fractographic images of the specimens were acquired using scanning electron microscopy (SEM) to analyze the fracture origin and crack propagation. Energy-dispersive X-ray spectroscopy (EDS) and attenuated total reflection Fourier transform infrared spectroscopy (FTIR-ATR) were used for chemical analysis, and X-ray diffractometry (XRD) was performed to analyze the crystalline phases. RESULTS:) in the AM group. SEM micrographs showed a more porous microstructure associated with the 3D printed samples. SIGNIFICANCE/CONCLUSIONS:crystals and higher degrees of porosity.
PMID: 37163816
ISSN: 1878-0180
CID: 5541172

Employing Indirect Adenosine 2A Receptors (A2AR) to Enhance Osseointegration of Titanium Devices: A Pre-Clinical Study

Pacheco-Vergara, Maria Jesus; Benalcázar-Jalkh, Ernesto Byron; Nayak, Vasudev V; Bergamo, Edmara T P; Cronstein, Bruce; Zétola, André Luis; Weiss, Fernando Pessoa; Grossi, João Ricardo Almeida; Deliberador, Tatiana Miranda; Coelho, Paulo G; Witek, Lukasz
The present study aimed to evaluate the effect of dipyridamole, an indirect adenosine 2A receptors (A2AR), on the osseointegration of titanium implants in a large, translational pre-clinical model. Sixty tapered, acid-etched titanium implants, treated with four different coatings ((i) Type I Bovine Collagen (control), (ii) 10 μM dipyridamole (DIPY), (iii) 100 μM DIPY, and (iv) 1000 μM DIPY), were inserted in the vertebral bodies of 15 female sheep (weight ~65 kg). Qualitative and quantitative analysis were performed after 3, 6, and 12 weeks in vivo to assess histological features, and percentages of bone-to-implant contact (%BIC) and bone area fraction occupancy (%BAFO). Data was analyzed using a general linear mixed model analysis with time in vivo and coating as fixed factors. Histomorphometric analysis after 3 weeks in vivo revealed higher BIC for DIPY coated implant groups (10 μM (30.42% ± 10.62), 100 μM (36.41% ± 10.62), and 1000 μM (32.46% ± 10.62)) in comparison to the control group (17.99% ± 5.82). Further, significantly higher BAFO was observed for implants augmented with 1000 μM of DIPY (43.84% ± 9.97) compared to the control group (31.89% ± 5.46). At 6 and 12 weeks, no significant differences were observed among groups. Histological analysis evidenced similar osseointegration features and an intramembranous-type healing pattern for all groups. Qualitative observation corroborated the increased presence of woven bone formation in intimate contact with the surface of the implant and within the threads at 3 weeks with increased concentrations of DIPY. Coating the implant surface with dipyridamole yielded a favorable effect with regard to BIC and BAFO at 3 weeks in vivo. These findings suggest a positive effect of DIPY on the early stages of osseointegration.
PMCID:10298984
PMID: 37367272
ISSN: 2079-4983
CID: 5540212

Long-term effects of canagliflozin treatment on the skeleton of aged UM-HET3 mice

Yildirim, Gozde; Bergamo, Edmara T P; Poudel, Sher Bahadur; Ruff, Ryan R; Dixit, Manisha; Hu, Bin; Mijares, Dindo Q; Witek, Lukasz; Chlebek, Carolyn; Harrison, David E; Strong, Randy; Miller, Richard A; Ladiges, Warren; Bromage, Timothy G; Rosen, Clifford J; Yakar, Shoshana
Sodium glucose cotransporter-2 inhibitors (SGLT2is) promote urinary glucose excretion and decrease plasma glucose levels independent of insulin. Canagliflozin (CANA) is an SGLT2i, which is widely prescribed, to reduce cardiovascular complications, and as a second-line therapy after metformin in the treatment of type 2 diabetes mellitus. Despite the robust metabolic benefits, reductions in bone mineral density (BMD) and cortical fractures were reported for CANA-treated subjects. In collaboration with the National Institute on Aging (NIA)-sponsored Interventions Testing Program (ITP), we tested skeletal integrity of UM-HET3 mice fed control (137 mice) or CANA-containing diet (180 ppm, 156 mice) from 7 to 22 months of age. Micro-computed tomography (micro-CT) revealed that CANA treatment caused significant thinning of the femur mid-diaphyseal cortex in both male and female mice, did not affect trabecular bone architecture in the distal femur or the lumbar vertebra-5 in male mice, but was associated with thinning of the trabeculae at the distal femur in CANA-treated female mice. In male mice, CANA treatment is associated with significant reductions in cortical bone volumetric BMD by micro-CT, and by quantitative backscattered scanning electron microscopy. Raman microspectroscopy, taken at the femur mid-diaphyseal posterior cortex, showed significant reductions in the mineral/matrix ratio and an increased carbonate/phosphate ratio in CANA-treated male mice. These data were supported by thermogravimetric assay (TGA) showing significantly decreased mineral and increased carbonate content in CANA-treated male mice. Finally, the sintered remains of TGA were subjected to X-ray diffraction and showed significantly higher fraction of whitlockite, a calcium orthophosphate mineral, which has higher resorbability than hydroxyapatite. Overall, long-term CANA treatment compromised bone morphology and mineral composition of bones, which likely contribute to increased fracture risk seen with this drug.
PMID: 37166526
ISSN: 2509-2723
CID: 5495712

Evaluation of instrumentation and pedicle screw design for posterior lumbar fixation: A pre-clinical in vivo/ex vivo ovine model

Witek, Lukasz; Parente, Paulo Eduardo Lima; Torroni, Andrea; Greenberg, Michael; Nayak, Vasudev Vivekanand; Hacquebord, Jacques Henri; Coelho, Paulo G
BACKGROUND/UNASSIGNED:" osseodensification rotary drilling compacts the bone fragments into the osteotomy walls, creating nucleating sites for regeneration. METHODS/UNASSIGNED:This study aimed to compare both manual versus rotary Osseodensification (OD) instrumentation as well as two different pedicle screw thread designs in a controlled split animal model in posterior lumbar stabilization to determine the feasibility and potential advantages of each variable with respect to mechanical stability and histomorphology. A total of 164 single thread (82 per thread configuration), pedicle screws (4.5 × 35 mm) were used for the study. Each animal received eight pedicles (four per thread design) screws, which were placed in the lumbar spine of 21 adult sheep. One side of the lumbar spine underwent rotary osseodensification instrumentation, while the contralateral underwent conventional, hand, instrumentation. The animals were euthanized after 6- and 24-weeks of healing, and the vertebrae were removed for biomechanical and histomorphometric analyses. Pullout strength and histologic analysis were performed on all harvested samples. RESULTS/UNASSIGNED: = 0.026) greater pullout strength (1060.6 N ± 181) relative to hand instrumentation (769.3 N ± 181) at the 24-week healing time point. Histomorphometric analysis exhibited significantly higher degrees of bone to implant contact for the rotary instrumentation only at the early healing time point (6 weeks), whereas bone area fraction occupancy was statistically higher for rotary instrumentation at both healing times. The levels of soft tissue infiltration were lower for pedicle screws placed in osteotomies prepared using OD instrumentation relative to hand instrumentation, independent of healing time. CONCLUSION/UNASSIGNED:The rotary instrumentation yielded enhanced mechanical and histologic results relative to the conventional hand instrumentation in this lumbar spine stabilization model.
PMCID:10285755
PMID: 37361331
ISSN: 2572-1143
CID: 5540112

The presence of 3D printing in orthopedics: A clinical and material review

Rodriguez Colon, Ricardo; Nayak, Vasudev Vivekanand; Parente, Paulo E L; Leucht, Philipp; Tovar, Nick; Lin, Charles C; Rezzadeh, Kevin; Hacquebord, Jacques H; Coelho, Paulo G; Witek, Lukasz
The field of additive manufacturing, 3D printing (3DP), has experienced an exponential growth over the past four decades, in part due to increased accessibility. Developments including computer-aided design and manufacturing, incorporation of more versatile materials, and improved printing techniques/equipment have stimulated growth of 3DP technologies within various industries, but most specifically the medical field. Alternatives to metals including ceramics and polymers have been garnering popularity due to their resorbable properties and physiologic similarity to extracellular matrix. 3DP has the capacity to utilize an assortment of materials and printing techniques for a multitude of indications, each with their own associated benefits. Within the field of medicine, advances in medical imaging have facilitated the integration of 3DP. In particular, the field of orthopedics has been one of the earliest medical specialties to implement 3DP. Current indications include education for patients, providers, and trainees, in addition to surgical planning. Moreover, further possibilities within orthopedic surgery continue to be explored, including the development of patient-specific implants. This review aims to highlight the use of current 3DP technology and materials by the orthopedic community, and includes comments on current trends and future direction(s) within the field.
PMID: 35634867
ISSN: 1554-527x
CID: 5235812

Giant Increase of Hardness in Silicon Carbide by Metastable Single Layer Diamond-Like Coating

Rejhon, Martin; Zhou, Xinliu; Lavini, Francesco; Zanut, Alessandra; Popovich, Filip; Schellack, Lorenzo; Witek, Lukasz; Coelho, Paulo; Kunc, Jan; Riedo, Elisa
Silicon carbide (SiC) is one of the hardest known materials. Its exceptional mechanical properties combined with its high thermal conductivity make it a very attractive material for a variety of technological applications. Recently, it is discovered that two-layer epitaxial graphene films on SiC can undergo a pressure activated phase transition into a sp3 diamene structure at room temperature. Here, it is shown that epitaxial graphene films grown on SiC can increase the hardness of SiC up to 100% at low loads (up to 900 µN), and up to 30% at high loads (10 mN). By using a Berkovich diamond indenter and nanoindentation experiments, it is demonstrated that the 30% increase in hardness is present even for indentations depths of 175 nm, almost three hundred times larger than the graphene film thickness. The experiments also show that the yield point of SiC increases up to 77% when the SiC surface is coated with epitaxial graphene. These improved mechanical properties are explained with the formation of diamene under the indenter's pressure.
PMCID:9951309
PMID: 36599685
ISSN: 2198-3844
CID: 5434292

Impact of implant thread design on insertion torque and osseointegration: a preclinical model

Benalcázar-Jalkh, E-B; Nayak, V-V; Gory, C; Marquez-Guzman, A; Bergamo, E-T; Tovar, N; Coelho, P-G; Bonfante, E-A; Witek, L
BACKGROUND:Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. MATERIAL AND METHODS/METHODS:A total of 48 type V Ti alloy implants were divided in two groups according to their thread design (D1= +0.1x/mm and D2= +0.15x/mm) and placed in an interpolated fashion into the radii of six beagles. Insertion torque was measured at time of placement, radii were extracted for histological processing following 3- and 6-week healing intervals. Histologic and histomorphometric analyses were performed in terms of bone to implant contact (%BIC) and bone area fraction occupancy within implant threads (%BAFO). Statistical analyses were performed through a linear mixed model with fixed factors of time and implant thread design. RESULTS:Surface roughness analysis demonstrated no significant differences in Sa and Sq between D1 and D2 implant designs, which confirmed that both implant designs were homogenous except for their respective thread profiles. For insertion torque, statistically significant lower values were recorded for D1 in comparison to D2 (59.6 ± 11.1 and 78.9 ± 10.1 N⋅cm, respectively). Furthermore, there were no significant differences with respect to histological analysis and histomorphometric parameters, between D1 and D2 at both time points. CONCLUSIONS:Both thread profiles presented equivalent potential to successfully osseointegrate in the osteotomies, with D2 yielding higher mechanical retention upon placement without detrimental bone resorption.
PMCID:9805329
PMID: 36173722
ISSN: 1698-6946
CID: 5409102