Effects of Anatomical Differences on Electromagnetic Fields, SAR, and Temperature Change

Alon, Leeor; Deniz, Cem Murat; Carluccio, Giuseppe; Brown, Ryan; Sodickson, Daniel K; Collins, Christopher M
Electromagnetic field simulations are increasingly used to assure RF safety of patients during MRI exams. In practice, however, tissue property distribution of the patient being imaged is not known, but may be represented with a pre-existing model. Repeatedly, agreement in transmit magnetic (B1 +) field distributions between two geometries has been used to suggest agreement in heating distributions. Here we examine relative effects of anatomical differences on B1 + distribution, Specific Absorption Rate (SAR) and temperature change (DeltaT). Numerical simulations were performed for a single surface coil positioned adjacent a homogeneous phantom and bovine phantom, each with slight geometric variations, and adjacent two different human body models. Experimental demonstration was performed on a bovine phantom using MR thermometry and B1 + mapping. Simulations and experiments demonstrate that B1 + distributions in different samples can be well correlated, while notable difference in maximum SAR and DeltaT occur. This work illustrates challenges associated with utilizing simulations or experiments for RF safety assurance purposes. Reliance on B1 + distributions alone for validation of simulations and/or experiments with a sample or subject for assurance of safety in another should be performed with caution.
PMCID:4847547
PMID: 27134586
ISSN: 1552-5031
CID: 2101092

A method for safety testing of radiofrequency/microwave-emitting devices using MRI

Alon, Leeor; Cho, Gene Y; Yang, Xing; Sodickson, Daniel K; Deniz, Cem M
PURPOSE: Strict regulations are imposed on the amount of radiofrequency (RF) energy that devices can emit to prevent excessive deposition of RF energy into the body. In this study, we investigated the application of MR temperature mapping and 10-g average specific absorption rate (SAR) computation for safety evaluation of RF-emitting devices. METHODS: Quantification of the RF power deposition was shown for an MRI-compatible dipole antenna and a non-MRI-compatible mobile phone via phantom temperature change measurements. Validation of the MR temperature mapping method was demonstrated by comparison with physical temperature measurements and electromagnetic field simulations. MR temperature measurements alongside physical property measurements were used to reconstruct 10-g average SAR. RESULTS: The maximum temperature change for a dipole antenna and the maximum 10-g average SAR were 1.83 degrees C and 12.4 W/kg, respectively, for simulations and 1.73 degrees C and 11.9 W/kg, respectively, for experiments. The difference between MR and probe thermometry was <0.15 degrees C. The maximum temperature change and the maximum 10-g average SAR for a cell phone radiating at maximum output for 15 min was 1.7 degrees C and 0.54 W/kg, respectively. CONCLUSION: Information acquired using MR temperature mapping and thermal property measurements can assess RF/microwave safety with high resolution and fidelity. Magn Reson Med, 2014. (c) 2014 Wiley Periodicals, Inc.
PMCID:4442746
PMID: 25424724
ISSN: 0740-3194
CID: 1359712

Magnetic resonance fingerprint compression [Meeting Abstract]

Cloos, Marijin; Zhao, T; Knoll, Florian; Alon, L; Lattanzi, R; Sodickson, Daniel K
ORIGINAL:0014695
ISSN: 1524-6965
CID: 4534412

A Fast Method to Estimate SAR Distribution from Temperature Images Highly Affected by Noise [Meeting Abstract]

Carluccio, Giuseppe; Knoll, Florian; Deniz, Cem Murat; Alon, Leeor; Collins, Chistopher Michael
ORIGINAL:0014708
ISSN: 1524-6965
CID: 4534582

Maximum efficiency radiofrequency shimming: Theory and initial application for hip imaging at 7 tesla

Deniz, Cem Murat; Brown, Ryan; Lattanzi, Riccardo; Alon, Leeor; Sodickson, Daniel K; Zhu, Yudong
Radiofrequency shimming with multiple channel excitation has been proposed to increase the transverse magnetic field uniformity and reduce specific absorption rate at high magnetic field strengths (>/=7 T) where high-frequency effects can make traditional single channel volume coils unsuitable for transmission. In the case of deep anatomic regions and power-demanding pulse sequences, optimization of transmit efficiency may be a more critical requirement than homogeneity per se. This work introduces a novel method to maximize transmit efficiency using multiple channel excitation and radiofrequency shimming. Shimming weights are calculated in order to obtain the lowest possible net radiofrequency power deposition into the subject for a given transverse magnetic field strength. The method was demonstrated in imaging studies of articular cartilage of the hip joint at 7 T. We show that the new radiofrequency shimming method can enable reduction in power deposition while maintaining an average flip angle or adiabatic condition in the hip cartilage. Building upon the improved shimming, we further show that the signal-to-noise ratio in hip cartilage at 7 T can be substantially greater than that at 3 T, illustrating the potential benefits of high field hip imaging. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
PMCID:3478493
PMID: 22714835
ISSN: 0740-3194
CID: 221072

Method for in situ characterization of radiofrequency heating in parallel transmit MRI

Alon, Leeor; Deniz, Cem Murat; Brown, Ryan; Sodickson, Daniel K; Zhu, Yudong
In ultra-high-field magnetic resonance imaging, parallel radiofrequency (RF) transmission presents both opportunities and challenges for specific absorption rate management. On one hand, parallel transmission provides flexibility in tailoring electric fields in the body while facilitating magnetization profile control. On the other hand, it increases the complexity of energy deposition as well as possibly exacerbating local specific absorption rate by improper design or delivery of RF pulses. This study shows that the information needed to characterize RF heating in parallel transmission is contained within a local power correlation matrix. Building upon a calibration scheme involving a finite number of magnetic resonance thermometry measurements, this work establishes a way of estimating the local power correlation matrix. Determination of this matrix allows prediction of temperature change for an arbitrary parallel transmit RF pulse. In the case of a three transmit coil MR experiment in a phantom, determination and validation of the power correlation matrix were conducted in less than 200 min with induced temperature changes of <4 degrees C. Further optimization and adaptation are possible, and simulations evaluating potential feasibility for in vivo use are presented. The method allows general characteristics indicative of RF coil/pulse safety determined in situ. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
PMCID:3449021
PMID: 22714806
ISSN: 0740-3194
CID: 221082

RF-emission device safety testing using MRI

Alon, L; Cho, GY; Yang, X; Zhu, Y; Sodickson, DK; Deniz, CM
Radiofrequency (RF) emitting wireless devices such as mobile phones are required to undergo standardized safety testing prior to entering the consumer market. Strict regulations are imposed on the amount of RF energy these devices are allowed to emit to prevent excessive deposition of RF energy into the body. In this work, a novel safety evaluation test for wireless devices using magnetic resonance thermometry is proposed.
SCOPUS:84894165647
ISSN: 1522-3965
CID: 843672

System and SAR characterization in parallel RF transmission

Zhu Y; Alon L; Deniz CM; Brown R; Sodickson DK
The markedly increased degrees of freedom introduced by parallel radiofrequency transmission presents both opportunities and challenges for specific absorption rate (SAR) management. On one hand they enable E-field tailoring and SAR reduction while facilitating excitation profile control. On other hand they increase the complexity of SAR behavior and the risk of inadvertently exacerbating SAR by improper design or playout of radiofrequency pulses. The substantial subject-dependency of SAR in high field magnetic resonance can be a compounding factor. Building upon a linear system concept and a calibration scheme involving a finite number of in situ measurements, this work establishes a clinically applicable method for characterizing global SAR behavior as well as channel-by-channel power transmission. The method offers a unique capability of predicting, for any excitation, the SAR and power consequences that are specific to the subject to be scanned and the MRI hardware. The method was validated in simulation and experimental studies, showing promise as the foundation to a prospective paradigm where power and SAR are not only monitored but, through prediction-guided optimization, proactively managed. Magn Reson Med, 2011. (c) 2011 Wiley Periodicals, Inc
PMCID:3299876
PMID: 22139808
ISSN: 1522-2594
CID: 149834

Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design

Deniz, Cem Murat; Alon, Leeor; Brown, Ryan; Sodickson, Daniel K; Zhu, Yudong
Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for which a regularization term is typically selected to control the integrated or peak pulse waveform amplitude. Unlike single-channel transmission, the specific absorption rate of parallel transmission is significantly influenced by interferences between the electric fields associated with the individual transmission elements, which a conventional regularization term does not take into account. This work explores the effects upon specific absorption rate of incorporating experimentally measurable electric field interactions into parallel transmission pulse design. Results of numerical simulations and phantom experiments show that the global specific absorption rate during parallel transmission decreases when electric field interactions are incorporated into pulse design optimization. The results also show that knowledge of electric field interactions enables robust prediction of the net power delivered to the sample or subject by parallel radiofrequency pulses before they are played out on a scanner. Magn Reson Med, 2011. (c) 2011 Wiley-Liss, Inc
PMCID:3245373
PMID: 22135040
ISSN: 1522-2594
CID: 147689

Prediction of motor recovery using initial impairment and fMRI 48 h poststroke

Zarahn, Eric; Alon, Leeor; Ryan, Sophia L; Lazar, Ronald M; Vry, Magnus-Sebastian; Weiller, Cornelius; Marshall, Randolph S; Krakauer, John W
There is substantial interpatient variation in recovery from upper limb impairment after stroke in patients with severe initial impairment. Defining recovery as a change in the upper limb Fugl-Meyer score (DeltaFM), we predicted DeltaFM with its conditional expectation (i.e., posterior mean) given upper limb Fugl-Meyer initial impairment (FM(ii)) and a putative functional magnetic resonance imaging (fMRI) recovery measure. Patients with first time, ischemic stroke were imaged at 2.5 +/- 2.2 days poststroke with 1.5-T fMRI during a hand closure task alternating with rest (fundamental frequency = 0.025 Hz, scan duration = 172 s). Confirming a previous finding, we observed that the prediction of DeltaFM by FM(ii) alone is good in patients with nonsevere initial hemiparesis but is not good in patients with severe initial hemiparesis (96% and 16% of the total sum of squares of DeltaFM explained, respectively). In patients with severe initial hemiparesis, prediction of DeltaFM by the combination of FM(ii) and the putative fMRI recovery measure nonsignificantly increased predictive explanation from 16% to 47% of the total sum of squares of DeltaFM explained. The implications of this preliminary negative result are discussed.
PMCID:3209795
PMID: 21527788
ISSN: 1047-3211
CID: 357422