Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants

Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S
OBJECTIVES: A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. DESIGN: Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. RESULTS: For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not observed for adults. An additional finding was that SMRT score was negatively correlated with age for adults with implants. CONCLUSIONS: Results from this study suggest that basic psychophysical capabilities of early implanted children and postlingually implanted adults differ when assessed in the sound field using their personal implant processors. Because spectral resolution does not improve with age for early implanted children, it seems likely that the sparse representation of the signal provided by a cochlear implant limits spectral resolution development. These results are supported by the finding that postlingually implanted adults, whose auditory systems matured before the onset of hearing loss, perform significantly better than early implanted children on the spectral resolution test.
PMID: 28682810
ISSN: 1538-4667
CID: 2617372

Perceptual Differences Between Low-Frequency Analog and Pulsatile Stimulation as Shown by Single- and Multidimensional Scaling

Stupak, Natalia; Padilla, Monica; Morse, Robert P; Landsberger, David M
Cochlear-implant users who have experienced both analog and pulsatile sound coding strategies often have strong preferences for the sound quality of one over the other. This suggests that analog and pulsatile stimulation may provide different information or sound quality to an implant listener. It has been well documented that many implant listeners both prefer and perform better with multichannel analog than multichannel pulsatile strategies, although the reasons for these differences remain unknown. Here, we examine the perceptual differences between analog and pulsatile stimulation on a single electrode. A multidimensional scaling task, analyzed across two dimensions, suggested that pulsatile stimulation was perceived to be considerably different from analog stimulation. Two associated tasks using single-dimensional scaling showed that analog stimulation was perceived to be less Clean on average than pulsatile stimulation and that the perceptual differences were not related to pitch. In a follow-up experiment, it was determined that the perceptual differences between analog and pulsatile stimulation were not dependent on the interpulse gap present in pulsatile stimulation. Although the results suggest that there is a large perceptual difference between analog and pulsatile stimulation, further work is needed to determine the nature of these differences.
PMID: 30378468
ISSN: 2331-2165
CID: 3400842

Pitch Ranking with Different Virtual Channel Configurations in Electrical Hearing

Padilla, Monica; Stupak, Natalia; Landsberger, David M
Monopolar Virtual Channels (MPVCs) use current steering to increase the number of spectral channels provided to cochlear implant users beyond the physical number of electrodes. The current spread created with a current steered channel is similar to the spread found for monopolar stimulation, and this spread may be one of the bottlenecks for improved performance with an increased number of channels. Quadrupolar Virtual Channels (QPVCs) use current focusing in combination with steering in an attempt to increase the number of channels while reducing channel interaction. However, due to the potentially asymmetric current field generated by QPVCs, there may be distortions in the place pitch representation using this mode. A Virtual Tripole (VTP) is introduced as a current focused virtual channel with a relatively symmetrical electric field distribution. In this study, we looked at pitch ranking in cochlear implant users with QPVC, VTP, and MPVC configurations to determine if place pitch shifts similarly across the cochlea or if any of the stimulation modes shift non-monotonically. Results suggest that MPVC and VTP stimulation provide a consistent monotonic shift across cochlear positions while the place shift provided by QPVCs was more variable. The use of VTP stimulation would be recommended instead of QPVC for a speech processing strategy.
PMID: 28216122
ISSN: 1878-5891
CID: 2460132

Loudness and Pitch Perception using Dynamically Compensated Virtual Channels

Nogueira, Waldo; Litvak, Leonid; Landsberger, David M; Buchner, Andreas
Reducing power consumption is important for the development of smaller cochlear implant (CI) speech processors. Simultaneous electrode stimulation may improve power efficiency by minimizing the required current applied to a given electrode. Simultaneous in-phase stimulation on adjacent electrodes (i.e. virtual channels) can be used to elicit pitch percepts intermediate to the ones provided by each of the physical electrodes in isolation. Virtual channels are typically implemented in monopolar stimulation mode, producing broad excitation patterns. Focused stimulation may reduce the excitation patterns, but is inefficient in terms of power consumption. To create a more power efficient virtual channel, we developed the Dynamically Compensated Virtual Channel (DC-VC) using four adjacent electrodes. The two central electrodes are current steered using the coefficient alpha (0
PMCID:5421637
PMID: 27939418
ISSN: 1878-5891
CID: 2363232

Use of Research Interfaces for Psychophysical Studies With Cochlear-Implant Users

Litovsky, Ruth Y; Goupell, Matthew J; Kan, Alan; Landsberger, David M
A growing number of laboratories are using research interfaces to conduct experiments with cochlear-implant (CI) users. Because these interfaces bypass a subject's clinical sound processor, several concerns exist regarding safety and stimulation levels. Here we suggest best-practice approaches for how to safely and ethically perform this type of research and highlight areas of limited knowledge where further research is needed to help clarify safety limits. The article is designed to provide an introductory level of technical detail about the devices and the effects of electrical stimulation on perception and neurophysiology. From this, we summarize what should be the best practices in the field, based on the literature and our experience. Findings from the review of the literature suggest that there are three main safety concerns: (a) to prevent biological or neural damage, (b) to avoid presentation of uncomfortably loud sounds, and (c) to ensure that subjects have control over stimulus presentation. Researchers must pay close attention to the software-hardware interface to ensure that the three main safety concerns are closely monitored. An important area for future research will be the determination of the amount of biological damage that can occur from electrical stimulation from a CI placed in the cochlea, not in direct contact with neural tissue. As technology used in research with CIs evolve, some of these approaches may change. However, the three main safety principles outlined here are not anticipated to undergo change with technological advances.
PMCID:5764139
PMID: 29113579
ISSN: 2331-2165
CID: 2772032

Encoding a Melody Using Only Temporal Information for Cochlear-Implant and Normal-Hearing Listeners

Todd, Ann E; Mertens, Griet; Van de Heyning, Paul; Landsberger, David M
One way to provide pitch information to cochlear implant users is through amplitude-modulation rate. It is currently unknown whether amplitude-modulation rate can provide cochlear implant users with pitch information adequate for perceiving melodic information. In the present study, the notes of a song were encoded via amplitude-modulation rate of pulse trains on single electrodes at the apex or middle of long electrode arrays. The melody of the song was either physically correct or modified by compression or expansion. Nine cochlear implant users rated the extent to which the song was out of tune in the different conditions. Cochlear implant users on average did not show sensitivity to melody compression or expansion regardless of place of stimulation. These results were found despite the fact that three of the cochlear implant users showed the expected sensitivity to melody compression and expansion with the same task using acoustic pure tones in a contralateral acoustic ear. Normal-hearing listeners showed an inconsistent and weak effect of melody compression and expansion when the notes of the song were encoded with acoustic pulse rate. The results suggest that amplitude-modulation rate provides insufficient access to melodic information for cochlear-implant and normal-hearing listeners.
PMCID:5703098
PMID: 29161987
ISSN: 2331-2165
CID: 2791592

Clinically Paired Electrodes Are Often Not Perceived as Pitch Matched

Aronoff, Justin M; Padilla, Monica; Stelmach, Julia; Landsberger, David M
For bilateral cochlear implant (CI) patients, electrodes that receive the same frequency allocation often stimulate locations in the left and right ear that do not yield the same perceived pitch, resulting in a pitch mismatch. This pitch mismatch may be related to degraded binaural abilities. Pitch mismatches have been found for some bilateral CI users and the goal of this study was to determine whether pitch mismatches are prevalent in bilateral CI patients, including those with extensive experience with bilateral CIs. To investigate this possibility, pitch matching was conducted with 16 bilateral CI patients. For 14 of the 16 participants, there was a significant difference between those electrodes in the left and right ear that yielded the same pitch and those that received the same frequency allocation in the participant's clinical map. The results suggest that pitch mismatches are prevalent with bilateral CI users. The results also indicated that pitch mismatches persist even with extended bilateral CI experience. Such mismatches may reduce the benefits patients receive from bilateral CIs.
PMCID:5029799
PMID: 27641682
ISSN: 2331-2165
CID: 2254532

Qualities of Single Electrode Stimulation as a Function of Rate and Place of Stimulation with a Cochlear Implant

Landsberger, David M; Vermeire, Katrien; Claes, Annes; Van Rompaey, Vincent; Van de Heyning, Paul
OBJECTIVES: Although it has been shown previously that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. The authors hypothesized that although temporal coding may provide useable information at any cochlear location, low rates of stimulation might provide better sound quality in apical regions that are more likely to encode temporal information in the normal ear. In the present study, sound qualities of single electrode pulse trains were scaled to provide insight into the combined effects of cochlear location and stimulation rate on sound quality. DESIGN: Ten long-term users of MED-EL cochlear implants with 31-mm electrode arrays (Standard or FLEX) were asked to scale the sound quality of single electrode pulse trains in terms of how "Clean," "Noisy," "High," and "Annoying" they sounded. Pulse trains were presented on most electrodes between 1 and 12 representing the entire range of the long electrode array at stimulation rates of 100, 150, 200, 400, or 1500 pulses per second. RESULTS: Although high rates of stimulation are scaled as having a Clean sound quality across the entire array, only the most apical electrodes (typically 1 through 3) were considered Clean at low rates. Low rates on electrodes 6 through 12 were not rated as Clean, whereas the low-rate quality of electrodes 4 and 5 were typically in between. Scaling of Noisy responses provided an approximately inverse pattern as Clean responses. High responses show the trade-off between rate and place of stimulation on pitch. Because High responses did not correlate with Clean responses, subjects were not rating sound quality based on pitch. CONCLUSIONS: If explicit temporal coding is to be provided in a cochlear implant, it is likely to sound better when provided apically. In addition, the finding that low rates sound clean only at apical places of stimulation is consistent with previous findings that a change in rate of stimulation corresponds to an equivalent change in perceived pitch at apical locations. Collectively, the data strongly suggest that temporal coding with a cochlear implant is optimally provided by electrodes placed well into the second cochlear turn.
PMCID:4844766
PMID: 26583480
ISSN: 1538-4667
CID: 1848702

Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users

Padilla, Monica; Landsberger, David M
Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy.
PMCID:4907334
PMID: 26778546
ISSN: 1878-5891
CID: 1922002

Frequency-place map for electrical stimulation in cochlear implants: Change over time

Vermeire, Katrien; Landsberger, David M; Van de Heyning, Paul H; Voormolen, Maurits; Kleine Punte, Andrea; Schatzer, Reinhold; Zierhofer, Clemens
The relationship between the place of electrical stimulation from a cochlear implant and the corresponding perceived pitch remains uncertain. Previous studies have estimated what the pitch corresponding to a particular location should be. However, perceptual verification is difficult because a subject needs both a cochlear implant and sufficient residual hearing to reliably compare electric and acoustic pitches. Additional complications can arise from the possibility that the pitch corresponding to an electrode may change as the auditory system adapts to a sound processor. In the following experiment, five subjects with normal or near-to-normal hearing in one ear and a cochlear implant with a long electrode array in the other ear were studied. Pitch matches were made between single electrode pulse trains and acoustic tones before activation of the speech processor to gain an estimate of the pitch provided by electrical stimulation at a given insertion angle without the influence of exposure to a sound processor. The pitch matches were repeated after 1, 3, 6, and 12 months of experience with the sound processor to evaluate the effect of adaptation over time. Pre-activation pitch matches were lower than would be estimated by a spiral ganglion pitch map. Deviations were largest for stimulation below 240 degrees degrees and smallest above 480 degrees . With experience, pitch matches shifted towards the frequency-to-electrode allocation. However, no statistically significant pitch shifts were observed over time. The likely explanation for the lack of pitch change is that the frequency-to-electrode allocations for the long electrode arrays were already similar to the pre-activation pitch matches. Minimal place pitch shifts over time suggest a minimal amount of perceptual remapping needed for the integration of electric and acoustic stimuli, which may contribute to shorter times to asymptotic performance.
PMCID:4524783
PMID: 25840373
ISSN: 1878-5891
CID: 1663442