Try a new search

Format these results:

Searched for:

person:vigdoj01

Total Results:

162


Templating for Total Hip Arthroplasty in the Modern Age

Vigdorchik, Jonathan M; Sharma, Abhinav K; Jerabek, Seth A; Mayman, David J; Sculco, Peter K
Preoperative templating provides several benefits to the patient, surgeon, and hospital. Appropriate implant selection and sizing optimizes surgical workflow and leads to efficient care-delivery systems. Accurate templating establishes intraoperative targets for component position and reduces complications such as leg length inequality, impingement, wear, dislocation, and fracture, all of which lead to decreased patient satisfaction. Recent technological advances in preoperative imaging include a better understanding of patient-specific pelvic motion allowing the surgeon to preoperatively address the risk of lumbar pathology with adjustments in component placement and bearing choice. The introduction of two-dimensional to three-dimensional (3D) radiographs, biplanar low-dose radiographs, and computed tomography scans with 3D reconstructions have all allowed for a more comprehensive preoperative planning in 3D. This article will review the fundamentals of templating before total hip arthroplasty with an emphasis on how to incorporate and implement patient-specific pelvic motion and 3D templating into practice.
PMID: 33543909
ISSN: 1940-5480
CID: 4776702

An Overview of Telehealth in Total Joint Arthroplasty

Windsor, Eric N; Sharma, Abhinav K; Gkiatas, Ioannis; Elbuluk, Ameer M; Sculco, Peter K; Vigdorchik, Jonathan M
With the increase in technological advances over the years, telehealth services in orthopedic surgery have gained in popularity, yet adoption among surgeons has been slow. With the onset of the COVID-19 pandemic, however, orthopedic surgery practices nationwide have accelerated adaptation to telemedicine. Telehealth can be effectively applied to total joint arthroplasty, with the ability to perform preoperative consultations, postoperative follow-up, and telerehabilitation in a virtual, remote manner with similar outcomes to in-person visits. New technologies that have emerged, such as virtual goniometers, wearable sensors, and app-based patient questionnaires, have improved clinicians' ability to conduct telehealth visits. Benefits of using telehealth include high patient satisfaction, cost-savings, increased access to care, and more efficiency. Notably, some challenges still exist, including widespread accessibility and adaptation of new technologies, inability to conduct an in-person orthopedic physical examination, and regulatory barriers, such as insurance reimbursement, increased medicolegal risk, and privacy and confidentiality concerns. Despite these hurdles, telehealth is here to stay and can be successfully incorporated in any total joint arthroplasty practice with the appropriate adjustments.
PMCID:8077983
PMID: 33967642
ISSN: 1556-3316
CID: 4867072

Telemedicine in an Outpatient Arthroplasty Setting During the COVID-19 Pandemic: Early Lessons from New York City

LeBrun, Drake G; Malfer, Christina; Wilson, Mallory; Carroll, Kaitlin M; Wang Ms, Victoria; Mayman, David J; Cross, Michael B; Alexiades, Michael M; Jerabek, Seth A; Cushner, Fred D; Vigdorchik, Jonathan M; Haas, Steven B; Ast, Michael P
Background: The early months of the coronavirus disease 19 (COVID-19) pandemic in New York City led to a rapid transition of non-essential in-person health care, including outpatient arthroplasty visits, to a telemedicine context. Questions/Purposes: Based on our initial experiences with telemedicine in an outpatient arthroplasty setting, we sought to determine early lessons learned that may be applicable to other providers adopting or expanding telemedicine services. Methods: A cross-sectional study was performed by surveying all patients undergoing telemedicine visits with 8 arthroplasty surgeons at 1 orthopedic specialty hospital in New York City from April 8 to May 19, 2020. Descriptive statistics were used to analyze demographic data, satisfaction with the telemedicine visit, and positive and negative takeaways. Results: In all, 164 patients completed the survey. The most common reasons for the telemedicine visit were short-term (less than 6 months), postoperative appointment (n = 88; 54%), and new patient consultation (n = 32; 20%). A total of 84 patients (51%) noted a reduction in expenses versus standard outpatient care. Several positive themes emerged from patient feedback, including less anxiety and stress related to traveling (n = 82; 50%), feeling more at ease in a familiar environment (n = 54; 33%), and the ability to assess postoperative home environment (n = 13; 8%). However, patients also expressed concerns about the difficulty addressing symptoms in the absence of an in-person examination (n = 28; 17%), a decreased sense of interpersonal connection with the physician (n = 20; 12%), and technical difficulties (n = 14; 9%). Conclusions: Patients were satisfied with their telemedicine experience during the COVID-19 pandemic; however, we identified several areas amenable to improvement. Further study is warranted.
PMCID:8077980
PMID: 33967638
ISSN: 1556-3316
CID: 4867062

Periprosthetic Fractures Through Tracking Pin Sites Following Computer Navigated and Robotic Total and Unicompartmental Knee Arthroplasty: A Systematic Review

Smith, Tyler J; Siddiqi, Ahmed; Forte, Salvador A; Judice, Anthony; Sculco, Peter K; Vigdorchik, Jonathan M; Schwarzkopf, Ran; Springer, Bryan D
BACKGROUND:Use of computer-assisted navigation (CAN) and robotic-assisted (RA) surgery in total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) both necessitate the use of tracking pins rigidly fixed to the femur and tibia. Although periprosthetic fractures through tracking pin sites are rare, there is a paucity of literature on this potential complication. Therefore, the purpose of this study was to perform a systematic review of the current literature to assess the incidence and clinical outcomes of periprosthetic fractures through tracking pin sites following CAN and RA TKA and UKA. METHODS:A systematic review was performed following PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines using the PubMed, MEDLINE, and Cochrane databases in April 2020. Studies were assessed for the presence of pin site fractures, fracture characteristics, and clinical outcomes. RESULTS:Seventeen clinical studies (5 case series, 1 cohort study, and 11 case reports) involving 29 pin-related fractures were included for review. The overall incidence ranged from 0.06% to 4.8%. The mean time from index arthroplasty to fracture was 9.5 weeks (range, 0 to 40 weeks). The majority of fractures occurred in the femoral diaphysis (59%). Nineteen fractures (66%) were displaced and 10 (34%) were nondisplaced or occult. The majority of cases were atraumatic in nature or involved minor trauma and were typically preceded by persistent leg pain. A transcortical pin trajectory, large pin diameter (>4 mm), diaphyseal fixation, multiple placement attempts, and the use of non-self-drilling, non-self-tapping pins were the most commonly reported risk factors for pin-related periprosthetic fractures following CAN or RA TKA. CONCLUSIONS:Surgeons should maintain a high index of suspicion for pin-related fractures in patients with ongoing leg or thigh pain after CAN or RA TKA in order to avoid fracture displacement and additional morbidity. As CAN and RA TKA have unique complication risks, the debate regarding the value of technology-assisted TKA and its cost-effectiveness continues. LEVEL OF EVIDENCE/METHODS:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
PMID: 33502139
ISSN: 2329-9185
CID: 4767282

High Offset Stems Are Protective of Dislocation in High-Risk Total Hip Arthroplasty

Vigdorchik, Jonathan M; Sharma, Abhinav K; Elbuluk, Ameer M; Carroll, Kaitlin M; Mayman, David J; Lieberman, Jay R
BACKGROUND:Spinal stiffness has been shown to increase risk of dislocation due to impingement and instability. Increasing anteversion of the acetabular component has been suggested to prevent dislocation, but little has been discussed in terms of femoral or global offset restoration. The purpose of this study is to quantify dislocation rates after primary THA using standard versus high-offset femoral components and to determine how differences in offset affect impingement-free range of motion in a stiff spine cohort using a novel impingement model. METHODS:A total of 12,365 patients undergoing THA from 2016 to 2018 were retrospectively reviewed to determine dislocation rates and utilization of standard- versus high-offset stems. For 50 consecutive patients with spinal stiffness, a CT-based computer software impingement modeling system assessed bony or prosthetic impingement during simulated range of motion. The model was run 5 times for each patient with varying offsets. Range of motion was simulated in each scenario to determine the degree at which impingement occurred. RESULTS:There were 51 dislocations for a 0.41% dislocation rate. Total utilization of high-offset stems in the entire cohort was 49%. Of those patients who sustained a dislocation, 49 (96%) utilized a standard-offset stem. The impingement modeling demonstrated 5 degrees of added range of motion until impingement for every 1 mm offset increase. CONCLUSION/CONCLUSIONS:In the impingement model, high-offset stems facilitated greater ROM before bony impingement and resulted in lower dislocation rates. In the setting of high-risk THA due to spinal stiffness, surgeons should consider the use of high-offset stems and pay attention to offset restoration.
PMID: 32741711
ISSN: 1532-8406
CID: 4553622

Lewinnek Safe Zone References are Frequently Misquoted

Burapachaisri, Aonnicha; Elbuluk, Ameer; Abotsi, Edem; Pierrepont, Jim; Jerabek, Seth A; Buckland, Aaron J; Vigdorchik, Jonathan M
Background/UNASSIGNED:Optimal acetabular component orientation in total hip arthroplasty (THA) is a necessity in achieving a stable implant. Although there has been considerable debate in the literature concerning the safe zone, to date, there has not been any review to determine if these references are consistent with the definition applied by Lewinnek et al. in 1978. Therefore, this article aims to examine the available literature in the PubMed database to determine how often a correct reference to the safe zone as defined by Lewinnek was applied to discussions regarding THA. Methods/UNASSIGNED:A search for literature in the PubMed database was performed for articles from 1978 to 2019. Search criteria included terms 'Lewinnek,' 'safe zone,' and 'total hip arthroplasty.' Exclusions included abstract-only articles, non-English articles, articles unrelated to THA, and those lacking full content. Results/UNASSIGNED:A review of literature yielded 147 articles for inclusion. Overall, only 11% (17) cited the Lewinnek article correctly. Forty-five percent (66) of articles referenced measurements in the supine position, 18% (26) referenced other positions, and 37% (55) did not specify. Nineteen percent (28) reported measurements of the acetabular cup orthogonal to the anterior pelvic plane, while 73% (108) did not, and 7% (11) did not specify. Twenty-three percent (34) measured from computed tomography scans instead of other methods. Conclusions/UNASSIGNED:In the discussion of the safe zone regarding THA, only 11% of articles listed are consistent with the definition established by Lewinnek. This warrants further investigation into a consistent application of the term and its implications for THA implant stability and dislocation rates.
PMCID:7701843
PMID: 33299915
ISSN: 2352-3441
CID: 4709122

The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip

Vigdorchik, Jonathan M; Sharma, Abhinav K; Aggarwal, Vinay K; Carroll, Kaitlin M; Jerabek, Seth A
Background/UNASSIGNED:Total hip arthroplasty (THA) is an effective operation for patients with hip osteoarthritis; however, patients with hip dysplasia present a particular challenge. Our novel study examined the effect of robot-assisted THA in patients with hip dysplasia. Methods/UNASSIGNED:We retrospectively reviewed patients with developmental dysplasia of the hip undergoing primary THA using robotic arm assistance at 2 institutions from January 2010 to January 2017. Patients undergoing revision arthroplasty were excluded. Preoperatively, all patients underwent a computed tomography scan so that 3-dimensional templating could be performed. Hip range of motion (ROM) and clinical leg length discrepancy were recorded preoperatively. Two independent observers calculated Crowe and Hartofilakidis grades for each operative hip. At the final follow-up, hip ROM, postoperative complications, and modified Harris Hip scores were obtained. Results/UNASSIGNED:< .0002). There were no complications during the short-term interim follow-up (mean: 3.1 years). Conclusions/UNASSIGNED:Robot-assisted THA can be a useful method to ensure adequate component positioning and excellent outcomes in patients with hip dysplasia. Level of Evidence/UNASSIGNED:Level III, Retrospective.
PMCID:7490591
PMID: 32964085
ISSN: 2352-3441
CID: 4603452

The Efficacy and Safety of Opioids in Total Joint Arthroplasty: Systematic Review and Direct Meta-Analysis

Hannon, Charles P; Fillingham, Yale A; Nam, Denis; Courtney, P Maxwell; Curtin, Brian M; Vigdorchik, Jonathan; Mullen, Kyle; Casambre, Francisco; Riley, Connor; Hamilton, William G; Della Valle, Craig J
BACKGROUND:Opioids are frequently used to treat pain after total joint arthroplasty (TJA). The purpose of this study was to evaluate the efficacy and safety of opioids in primary TJA to support the combined clinical practice guidelines of the American Association of Hip and Knee Surgeons, American Academy of Orthopaedic Surgeons, Hip Society, Knee Society, and the American Society of Regional Anesthesia and Pain Management. METHODS:The MEDLINE, EMBASE, and Cochrane Central Register of controlled trials were searched for studies published before November 2018 on opioids in TJA. All included studies underwent qualitative and quantitative homogeneity testing followed by a systematic review and direct comparison meta-analysis to assess the efficacy and safety of opioids. RESULTS:Preoperative opioid use leads to increased opioid consumption and complications after TJA along with a higher risk of chronic opioid use and inferior patient-reported outcomes. Scheduled opioids administered preemptively, intraoperatively, or postoperatively reduce the need for additional opioids for breakthrough pain. Prescribing fewer opioid pills after discharge is associated with equivalent functional outcomes and decreased opioid consumption. Tramadol reduces postoperative opioid consumption but increases the risk of postoperative nausea, vomiting, dry mouth, and dizziness. CONCLUSION/CONCLUSIONS:Moderate evidence supports the use of opioids in TJA to reduce postoperative pain and opioid consumption. Opioids should be used cautiously as they may increase the risk of complications, such as respiratory depression and sedation, especially if combined with other central nervous system depressants or used in the elderly.
PMID: 32571589
ISSN: 1532-8406
CID: 4703592

Opioids in Total Joint Arthroplasty: The Clinical Practice Guidelines of the American Association of Hip and Knee Surgeons, American Society of Regional Anesthesia and Pain Medicine, American Academy of Orthopedic Surgeons, Hip Society, and Knee Society

Hannon, Charles P; Fillingham, Yale A; Nam, Denis; Courtney, P Maxwell; Curtin, Brian M; Vigdorchik, Jonathan M; Buvanendran, Asokumar; Hamilton, William G; Della Valle, Craig J
PMID: 32571594
ISSN: 1532-8406
CID: 4492922

Does Prosthetic or Bony Impingement Occur More Often in Total Hip Arthroplasty: A Dynamic Preoperative Analysis

Vigdorchik, Jonathan M; Sharma, Abhinav K; Madurawe, Chameka S; Elbuluk, Ameer M; Baré, Jonathan V; Pierrepont, Jim W
BACKGROUND:Impingement is a leading cause for instability resulting in revision total hip arthroplasty (THA). Impingement can be prosthetic, bony, or soft tissue. The purpose of this study is to investigate, using a virtual simulation, whether bony or prosthetic impingement presents first in well-positioned THAs. METHODS:Twenty-three patients requiring THA were planned for a ceramic-on-poly cementless construct using dynamic planning software. Cups were orientated at 45° inclination and 25° anteversion when standing. Femoral components and neck lengths were positioned to reproduce native anteversion and match contralateral leg length and offset. The type and location of impingement was then recorded with recreation of anterior and posterior impingement during standard and extreme ranges of motion (ROM). RESULTS:In standard ROM, flexion produced both prosthetic and bony impingement and extension resulted in prosthetic impingement in models with lipped liners. In extreme ROM, anterior impingement was 78% bony in 32-mm articulations, and 88% bony in 36-mm articulations. Posterior impingement was 65% prosthetic in 32-mm articulations, and 55% prosthetic in 36-mm articulations. Dual mobility cups showed the greatest risk of posterior prosthetic impingement in hyperextension (74%). CONCLUSION/CONCLUSIONS:In standard ROM, both bony and prosthetic impingement occurred in flexion, while prosthetic impingement occurred in extension in models with lipped liners. In hyperextension, prosthetic impingement was more common than bony impingement, and was exclusively the cause of impingement when a lip was used. In flexion, impingement was primarily bony with the use of a 36-mm head. The risk of posterior prosthetic impingement was greatest with dual mobility cups. LEVEL OF EVIDENCE/METHODS:3.
PMID: 32507449
ISSN: 1532-8406
CID: 4477672