Try a new search

Format these results:

Searched for:

person:it16

Total Results:

124


Prevalence and Characteristics of Accessory Mandibular Canals: A Cone-Beam Computed Tomography Study in a European Adult Population

Varvara, Giuseppe; Feragalli, Beatrice; Turkyilmaz, Ilser; D'Alonzo, Aurelio; Rinaldi, Fabiola; Bianchi, Serena; Piattelli, Maurizio; Macchiarelli, Guido; Bernardi, Sara
The purpose of this observational study is to evaluate the prevalence and main characteristics of bifid canals within a European adult population, analyzing cone-beam-computed tomography (CBCT). The population study examined 300 subjects. The CBCTs were performed between 2012 and 2019, using PaX-Zenith3D with a standard protocol of acquisition. The parameters analyzed were the presence and lengths of the bifid mandibular canals. The sample included 49% male and 51% female participants. The mean age of the patients was 47.07 ± 17.7 years. Anatomical variants of the mandibular canal were identified in 28.8% of the sides and 50.3% of the patients. In 7.3% of the subjects, the anatomical variants were present bilaterally. The most frequently encountered bifid canal was Type 3 (40.5%), followed by the Type 1 canal (39.3%), the Type 2 canal (14.5%), and the Type 4 canal (5.9%), 40% on the right side and 60% on the left side. The average length of the bifid canals located on the right side of the mandible was 11.96 ± 5.57 mm, compared to 11.38 ± 4.89 mm for those measured on the left side. The bifid mandibular canal is a common anatomical variation of the mandibular canal. It is fundamental to performing an accurate preoperative evaluation using CBCT analysis to avoid and/or reduce intraoperative and postoperative complications.
PMCID:9406331
PMID: 36010235
ISSN: 2075-4418
CID: 5387212

Transforming smiles using an intraoral scanner and face scan application on smartphone

Asutay, Hilal Ciftci; Turkyilmaz, Ilser; Benli, Merve; Martinez, Jacqueline L
PMCID:9236924
PMID: 35784169
ISSN: 2213-8862
CID: 5280802

Moving from analogue to digital workflows in dentistry: Understanding undermilling and overmilling as detrimental factors in fabricating CAD/CAM crowns

Turkyilmaz, Ilser; Wilkins, Gregory Neil; Yun, Sarah
Due to the limitations caused by the specific dimensions of milling burs, milling machines may inaccurately fabricate restorations by either over-reducing or under-reducing restorative material, respectively known as "overmilling" and "undermilling". Overmilling occurs when the bur is unable to accommodate areas smaller than the size of the bur, especially at cusp tips and sharp line angles. This results in excess cement space and a weaker restoration. Undermilling occurs when small concavities are ignored by the larger milling bur, particularly at the margins. This results in inadequate seating of the restoration and open margins due to premature binding, which can lead to restorative failure. To prevent these processing errors, clinicians should ensure that all incisal edges and cusp tips are flattened and rounded, verify that there are no undercuts, and prepare teeth with 1mm thick, smooth finish lines. Furthermore, clinicians may use the preparation check and milling simulation step of computer-aided design/computer-aided manufacturing (CAD/CAM) software to confirm the preparation is adequate and the restorative design does not have potential areas that will lead to overmilling.
PMID: 35658655
ISSN: 2050-1684
CID: 5236322

Transformation of preclinical education with a digital platform using progressive learning modules on denture teeth arrangement

Turkyilmaz, Ilser; Wilkins, Gregory Neil; Skiba, William Friere
PMID: 35383502
ISSN: 2050-1684
CID: 5201612

Relationship between the data quality of digital scans from intraoral scanners and surface topography of prepared teeth

Turkyilmaz, Ilser; Wilkins, Gregory Neil; Benli, Merve
PMCID:8738113
PMID: 35028093
ISSN: 2213-8862
CID: 5116312

Effects of abutment length and platform size on the retention of implant-supported CAD/CAM crowns using six different cements

Kirman, Emine Ayca; Asar, Neset Volkan; Erdem, Babur; Turkyilmaz, Ilser
PMCID:8739273
PMID: 35028096
ISSN: 2213-8862
CID: 5147442

Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans

Uluc, Irem Gokce; Guncu, Mustafa Baris; Aktas, Guliz; Turkyilmaz, Ilser
Background/purpose/UNASSIGNED:Advancements in digital dentistry and the development of intraoral scanners (IOS) have provided clinicians with an accurate and efficient alternative to analog impressions. The aim of this study was to assess the accuracy of the marginal and internal fit of 5-unit monolithic zirconia fixed dental prostheses (FDPs) fabricated with CAD/CAM technology using direct and indirect digitalization methods. Material and methods/UNASSIGNED:Three teeth in a maxillary typodont model were prepared to receive a 5-unit zirconia FDP. Six different groups were created according to the type of scanner (intraoral and extraoral) and the type of workflow. For direct workflow, the typodont was scanned with two different IOS (3Shape Trios 3 [3S-IOS] and Cerec Omnicam [C-IOS]). For indirect workflow, after conventional impressions were obtained, the impressions (IMP) were scanned with two different laboratory scanners (3S-IMP and C-IMP). After the impressions were poured, the stone (STN) casts were scanned with the same laboratory scanners (3S-STN and C-STN). Sixty 5-unit monolithic zirconia FDPs (10 in each group) were designed and milled. The marginal and internal fit was assessed. Results/UNASSIGNED:The mean marginal gap values were 78.2±9 μm in the IOS group, 82.6± 9 μm in the IMP group, and 82.6±9 μm in the STN group, indicating no statistically significant differences among groups (p > 0.05). The mean axial gap values were 77.7 ± 10 μm in IOS group, 83.61 ± 15 μm in the IMP group, and 84.5±9 μm in the STN group, indicating no statistically significant differences among groups (p > 0.05). Conclusion/UNASSIGNED:The marginal and internal fit of 5-unit monolithic zirconia FDPs fabricated with direct and indirect digital scans were similar. The smallest gap values were observed at the marginal region while the greatest gap values were detected at the occlusal region.
PMCID:8739750
PMID: 35028021
ISSN: 2213-8862
CID: 5182472

Analysis of the relationship between the surface topography of prepared tooth surfaces and data quality of digital impressions from an intraoral scanner

Asar, Neset Volkan; Yun, Sarah; Schwartz, Shelby; Turkyilmaz, Ilser
Background/purpose/UNASSIGNED:With the rise of digitalization in dentistry, intraoral scanners and digital impressions have recently been adopted by many clinicians. The aim of this study was to investigate surface topography of prepared teeth and the accuracy of digital impressions. Materials and methods/UNASSIGNED:Twenty mandibular typodonts, containing left first premolar and left first molar abutment teeth manufactured by using CAD/CAM, were used in this study. An intraoral scanner was used to scan each typodont, and each STL file generated was exported in high resolution (Group H), moderate resolution (Group M), and low resolution (Group L). All 60 files were inspected in a 3-D mesh processing software. For each file, the number of triangulation points in the meshwork were obtained for both abutment teeth. Results/UNASSIGNED:The measurements obtained from the 3-D mesh processing software revealed that the mean number of triangulation points on the 3-D surface of the abutment teeth (20 premolars + 20 M) were 790,625 ± 98,890 dots in Group H, 592,283 ± 74,881 dots in Group M, and 198,067 ± 19,328 dots in Group L. Significant differences were found between Group H and M (p < 0.05), Group H and L (p < 0.001), and Group M and L (p < 0.01). Conclusion/UNASSIGNED:The outcomes of this study reveal that there are strong correlations between the data quality of digital impressions and surface topography of prepared teeth. Therefore, the utilization of STL files in high resolution format is the recommended choice for clinicians engaging in a digital workflow process.
PMCID:8740072
PMID: 35028082
ISSN: 2213-8862
CID: 5142302

Correlation between the data quality of digital impressions and surface topography of prepared teeth

Turkyilmaz, Ilser; Yun, Sarah; Wilkins, Gregory Neil; Benli, Merve
PMCID:8739252
PMID: 35028090
ISSN: 2213-8862
CID: 5142312

Swirl marks on the internal surface of restorations during mill simulation: A pathway to catastrophic failures

Turkyilmaz, Ilser; Wilkins, Gregory Neil
PMCID:8739247
PMID: 35028098
ISSN: 2213-8862
CID: 5142322