Try a new search

Format these results:

Searched for:

person:holmed01

in-biosketch:true

Total Results:

92


Personalized Ablation Strategies Optimize First Pass Isolation and Minimize Pulmonary Vein Reconnection During Paroxysmal Atrial Fibrillation Ablation

Junarta, Joey; Qiu, Jessica; Cheng, Austin V; Barbhaiya, Chirag R; Jankelson, Lior; Holmes, Douglas; Kushnir, Alexander; Knotts, Robert J; Yang, Felix; Bernstein, Scott A; Park, David S; Chinitz, Larry A; Aizer, Anthony
PMID: 39447812
ISSN: 1556-3871
CID: 5740132

Performance of a Protein Language Model for Variant Annotation in Cardiac Disease

Hochstadt, Aviram; Barbhaiya, Chirag; Aizer, Anthony; Bernstein, Scott; Cerrone, Marina; Garber, Leonid; Holmes, Douglas; Knotts, Robert J; Kushnir, Alex; Martin, Jacob; Park, David; Spinelli, Michael; Yang, Felix; Chinitz, Larry A; Jankelson, Lior
BACKGROUND:Genetic testing is a cornerstone in the assessment of many cardiac diseases. However, variants are frequently classified as variants of unknown significance, limiting the utility of testing. Recently, the DeepMind group (Google) developed AlphaMissense, a unique artificial intelligence-based model, based on language model principles, for the prediction of missense variant pathogenicity. We aimed to report on the performance of AlphaMissense, accessed by VarCardio, an open web-based variant annotation engine, in a real-world cardiovascular genetics center. METHODS AND RESULTS/RESULTS:<0.001). Genotype-phenotype concordance was highly aligned using VarCard.io predictions, at 95.9% (95% CI, 92.8-97.9) concordance rate. For 109 variants classified as pathogenic, likely pathogenic, benign, or likely benign by ClinVar, concordance with VarCard.io was high (90.5%). CONCLUSIONS:AlphaMissense, accessed via VarCard.io, may be a highly efficient tool for cardiac genetic variant interpretation. The engine's notable performance in assessing variants that are classified as variants of unknown significance in ClinVar demonstrates its potential to enhance cardiac genetic testing.
PMID: 39392163
ISSN: 2047-9980
CID: 5706292

Catheter ablation alone versus catheter ablation with combined percutaneous left atrial appendage closure for atrial fibrillation: a systematic review and meta-analysis

Junarta, Joey; Siddiqui, Muhammad U; Abaza, Ehab; Zhang, Peter; Roshandel, Aarash; Barbhaiya, Chirag R; Jankelson, Lior; Park, David S; Holmes, Douglas; Chinitz, Larry A; Aizer, Anthony
BACKGROUND:Combined catheter ablation (CA) with percutaneous left atrial appendage closure (LAAC) may produce comprehensive treatment for atrial fibrillation (AF) whereby rhythm control is achieved and stroke risk is reduced without the need for chronic oral anticoagulation. However, the efficacy and safety of this strategy is still controversial. METHODS:This meta-analysis was reported according to the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines. Medline, Scopus, and Cochrane Central Register of Controlled Trials were systematically searched to identify relevant studies. The risk of bias was assessed using the Modified Newcastle-Ottawa scale and Cochrane risk of bias tool. Eligible studies reported outcomes in patients with AF who underwent combined CA and LAAC vs CA alone. Studies performing CA without pulmonary vein isolation were excluded. RESULTS:Eight studies comprising 1878 patients were included (2 RCT, 6 observational). When comparing combined CA and LAAC vs CA alone, pooled results showed no difference in arrhythmia recurrence (risk ratio (RR) 1.04; 95% confidence interval (CI) 0.82-1.33), stroke or systemic embolism (RR 0.78; 95% CI 0.27-2.22), or major periprocedural complications (RR 1.28; 95% CI 0.28-5.89). Total procedure time was shorter with CA alone (mean difference 48.45 min; 95% CI 23.06-74.62). CONCLUSION/CONCLUSIONS:Combined CA with LAAC for AF is associated with similar rates of arrhythmia-free survival, stroke, and major periprocedural complications when compared to CA alone. A combined strategy may be as safe and efficacious for patients at moderate to high risk for bleeding events to negate the need for chronic oral anticoagulation.
PMID: 39230634
ISSN: 1572-8595
CID: 5687972

Risk of malignant ventricular arrhythmias in patients with mildly to moderately reduced ejection fraction after permanent pacemaker implantation

Dai, Matthew; Peterson, Connor; Chorin, Udi; Leiva, Orly; Katz, Moshe; Sliman, Hend; Aizer, Anthony; Barbhaiya, Chirag; Bernstein, Scott; Holmes, Douglas; Knotts, Robert; Park, David; Spinelli, Michael; Chinitz, Larry; Jankelson, Lior
BACKGROUND:Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown. OBJECTIVE:The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF. METHODS:Retrospective analysis was performed of 243 patients with LVEF between 35% and 49% who underwent PPM placement and did not meet indications for an ICD. The primary end point was occurrence of sustained VT/VF. Competing risks regression was performed to calculate subhazard ratios for the primary end point. RESULTS:Median follow-up was 27 months; 73% of patients were male, average age was 79 ± 10 years, average LVEF was 42% ± 4%, and 70% were New York Heart Association class II or above. Most PPMs were implanted for sick sinus syndrome (34%) or atrioventricular block (50%). Of 243 total patients, 11 (4.5%) met the primary end point of VT/VF. Multivessel coronary artery disease (CAD) was associated with significantly higher rates of VT/VF, with a subhazard ratio of 5.4 (95% CI, 1.5-20.1; P = .01). Of patients with multivessel CAD, 8 of 82 (9.8%) patients met the primary end point for an annualized risk of 4.3% per year. CONCLUSION:Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias. Patients in this population may benefit from additional risk stratification for VT/VF and consideration for upfront ICD implantation.
PMID: 38490597
ISSN: 1556-3871
CID: 5713832

Catheter ablation compared to medical therapy for ventricular tachycardia in sarcoidosis: nationwide outcomes and hospital readmissions

Gurin, Michael I; Xia, Yuhe; Tarabanis, Constantine; Goldberg, Randal I; Knotts, Robert J; Donnino, Robert; Reyentovich, Alex; Bernstein, Scott; Jankelson, Lior; Kushnir, Alexander; Holmes, Douglas; Spinelli, Michael; Park, David S; Barbhaiya, Chirag R; Chinitz, Larry A; Aizer, Anthony
BACKGROUND/UNASSIGNED:Catheter ablation (CA) for ventricular tachycardia (VT) can be a useful treatment strategy, however, few studies have compared CA to medical therapy (MT) in the sarcoidosis population. OBJECTIVE/UNASSIGNED:To assess in-hospital outcomes and unplanned readmissions following CA for VT compared to MT in patients with sarcoidosis. METHODS/UNASSIGNED:Data was obtained from the Nationwide Readmissions Database between 2010 and 2019 to identify patients with sarcoidosis admitted for VT either undergoing CA or MT during elective and non-elective admission. Primary endpoints were a composite endpoint of inpatient mortality, cardiogenic shock, cardiac arrest and 30-day hospital readmissions. Procedural complications at index admission and causes of readmission were also identified. RESULTS/UNASSIGNED: = 0.343). The most common cause of readmission were ventricular arrhythmias (VA) in both groups, however, those undergoing elective CA were less likely to be readmitted for VA compared to non-elective CA. The most common complication in the CA group was cardiac tamponade (4.8 %). CONCLUSION/UNASSIGNED:VT ablation is associated with similar rates of 30-day readmission compared to MT and does not confer increased risk of harm with respect to inpatient mortality, cardiogenic shock or cardiac arrest. Further research is warranted to determine if a subgroup of sarcoidosis patients admitted with VT are better served with an initial conservative management strategy followed by VT ablation.
PMCID:11279686
PMID: 39070127
ISSN: 2666-6022
CID: 5731242

Caudal-Tilt Ultrasound Guided Axillary Venous Access for Transvenous Pacing Lead Implant

Kaul, Risheek; Yang, Felix; Jankelson, Lior; Knotts, Robert J; Holmes, Douglas; Aizer, Anthony; Chinitz, Larry A; Barbhaiya, Chirag R
PMID: 38266750
ISSN: 1556-3871
CID: 5624992

Conduction velocity is reduced in the posterior wall of hypertrophic cardiomyopathy patients with normal bipolar voltage undergoing ablation for paroxysmal atrial fibrillation

Zahid, Sohail; Malik, Tahir; Peterson, Connor; Tarabanis, Constantine; Dai, Matthew; Katz, Moshe; Bernstein, Scott A; Barbhaiya, Chirag; Park, David S; Knotts, Robert J; Holmes, Douglas S; Kushnir, Alexander; Aizer, Anthony; Chinitz, Larry A; Jankelson, Lior
OBJECTIVES/OBJECTIVE:We investigated characteristics of left atrial conduction in patients with HCM, paroxysmal AF and normal bipolar voltage. BACKGROUND:Patients with hypertrophic cardiomyopathy (HCM) exhibit abnormal cardiac tissue arrangement. The incidence of atrial fibrillation (AF) is increased fourfold in patients with HCM and confers a fourfold increased risk of death. Catheter ablation is less effective in HCM, with twofold increased risk of AF recurrence. The mechanisms of AF perpetuation in HCM are poorly understood. METHODS:We analyzed 20 patients with HCM and 20 controls presenting for radiofrequency ablation of paroxysmal AF normal left atrial voltage(> 0.5 mV). Intracardiac electrograms were extracted from the CARTO mapping system and analyzed using Matlab/Python code interfacing with Core OpenEP software. Conduction velocity maps were calculated using local activation time gradients. RESULTS: = 0.13, p = 0.03). CONCLUSIONS:Atrial conduction velocity is significantly reduced in patients with HCM and paroxysmal AF, possibly contributing to arrhythmia persistence after catheter ablation.
PMID: 36952090
ISSN: 1572-8595
CID: 5523872

Optimal conditions for high-power, short-duration radiofrequency ablation using a novel, flexible-tipped, force-sensing catheter

Piccini, Jonathan P; Dave, Amish S; Holmes, Douglas S; Winterfield, Jeffrey R; Tranter, John H; Pipenhagen, Catherine; Moon, L Boyce; Ambrosius, Nicholas M; Overmann, Jed A; Boudlali, Hana; Thao, Riki; Geurkink, Chris; Thamavong, Zada; Jensen, James A; Fish, Jeffrey M
BACKGROUND/UNASSIGNED:High-power, short-duration (HPSD) radiofrequency ablation (RFA) reduces procedure time; however, safety and efficacy thresholds vary with catheter design. OBJECTIVE/UNASSIGNED:The study sought to determine optimal HPSD ablation conditions with a novel flexible-tipped, contact force-sensing RFA catheter. METHODS/UNASSIGNED:RFA lesions were created in thigh muscle (16 swine) over a range of conditions (51-82 W, 2-40 g, 8-40 mL/min irrigation). An intracardiac study was performed (12 swine) to characterize steam pop thresholds. Lesions were created in a second intracardiac study (14 swine, n = 290 pulmonary vein isolation [PVI] lesions) with combinations of radiofrequency power, duration, and contact force. PVI was tested, animals were sacrificed, and lesions were measured. RESULTS/UNASSIGNED:= .038). During PVI, focal atrial lesions ranged in width from 4.2 to 12.5 mm and were transmural 80.8% of the time. PVI was achieved in 13 of 14 veins. Logistic regression identified that the optimal parameters for radiofrequency application were 60 to 70 W with a duration <8 seconds and <15 g contact force. CONCLUSIONS/UNASSIGNED:Optimal HPSD lesions with this this flexible-tipped, force-sensing RFA catheter were created at 60 to 70 W for <8 seconds with <15 g contact force. Chronic studies are ongoing to assess radiofrequency parameter refinements and long-term lesion durability using these conditions.
PMCID:10373153
PMID: 37520016
ISSN: 2666-5018
CID: 5734692

Comparison of combined substrate-based mapping techniques to identify critical sites for ventricular tachycardia ablation

Khan, Hassan; Bonvissuto, Matthew R; Rosinski, Elizabeth; Shokr, Mohamed; Metcalf, Kara; Jankelson, Lior; Kushnir, Alexander; Park, David S; Bernstein, Scott A; Spinelli, Michael A; Aizer, Anthony; Holmes, Douglas; Chinitz, Larry A; Barbhaiya, Chirag R
BACKGROUND:Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation. The relative utilities of these mapping techniques are unknown. OBJECTIVE:The purpose of this study was to evaluate the relative utility of various substrate mapping techniques for the identification of critical sites for VT ablation. METHODS:Electroanatomic substrate maps were created and retrospectively analyzed in 27 patients in whom 33 VT critical sites were identified. RESULTS:. CONCLUSION/CONCLUSIONS:ILAM, fractionation, and CV mapping each identified distinct critical sites and provided a smaller area of interest than did voltage mapping alone. The sensitivity of novel mapping modalities improved with greater local point density.
PMID: 36863636
ISSN: 1556-3871
CID: 5462332

Catheter ablation of atrioventricular nodal reentrant tachycardia with an irrigated contact-force sensing radiofrequency ablation catheter

Panday, Priya; Holmes, Douglas; Park, David S; Jankelson, Lior; Bernstein, Scott A; Knotts, Robert; Kushnir, Alexander; Aizer, Anthony; Chinitz, Larry A; Barbhaiya, Chirag R
INTRODUCTION/BACKGROUND:Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. METHODS:Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. RESULTS:The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. CONCLUSION/CONCLUSIONS:Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.
PMID: 36738141
ISSN: 1540-8167
CID: 5420642