Try a new search

Format these results:

Searched for:

person:moscar01

in-biosketch:true

Total Results:

180


Utility and Scope of Rapid Prototyping in Patients with Complex Muscular Ventricular Septal Defects or Double-Outlet Right Ventricle: Does it Alter Management Decisions?

Bhatla, Puneet; Tretter, Justin T; Ludomirsky, Achi; Argilla, Michael; Latson, Larry A Jr; Chakravarti, Sujata; Barker, Piers C; Yoo, Shi-Joon; McElhinney, Doff B; Wake, Nicole; Mosca, Ralph S
Rapid prototyping facilitates comprehension of complex cardiac anatomy. However, determining when this additional information proves instrumental in patient management remains a challenge. We describe our experience with patient-specific anatomic models created using rapid prototyping from various imaging modalities, suggesting their utility in surgical and interventional planning in congenital heart disease (CHD). Virtual and physical 3-dimensional (3D) models were generated from CT or MRI data, using commercially available software for patients with complex muscular ventricular septal defects (CMVSD) and double-outlet right ventricle (DORV). Six patients with complex anatomy and uncertainty of the optimal management strategy were included in this study. The models were subsequently used to guide management decisions, and the outcomes reviewed. 3D models clearly demonstrated the complex intra-cardiac anatomy in all six patients and were utilized to guide management decisions. In the three patients with CMVSD, one underwent successful endovascular device closure following a prior failed attempt at transcatheter closure, and the other two underwent successful primary surgical closure with the aid of 3D models. In all three cases of DORV, the models provided better anatomic delineation and additional information that altered or confirmed the surgical plan. Patient-specific 3D heart models show promise in accurately defining intra-cardiac anatomy in CHD, specifically CMVSD and DORV. We believe these models improve understanding of the complex anatomical spatial relationships in these defects and provide additional insight for pre/intra-interventional management and surgical planning.
PMID: 27837304
ISSN: 1432-1971
CID: 2304632

Cardiopulmonary bypass, cardioplegia, confocal inspection...? [Editorial]

Mosca, Ralph S
PMID: 27343916
ISSN: 1097-685x
CID: 2165492

Retrograde transcatheter device closure of a complex paravalvular leak after bioprosthetic pulmonary valve replacement in a pediatric patient

Chikkabyrappa, Sathish; Mosca, Ralph S; McElhinney, Doff B
We report a case of retrograde transcatheter device closure of a complex paravalvular leak (PVL) after bioprosthetic pulmonary valve replacement (PVR) in a 13-year-old patient with congenital pulmonary valve stenosis. There are prior reports of pulmonary PVL closure after PVR in adults (Seery and Slack, Congenit Heart Dis 2014;9:E19-F22), but indications for and technical considerations in PVL closure after bioprosthetic PVR, particularly in children, are not well defined. (c) 2015 Wiley Periodicals, Inc.
PMID: 26514545
ISSN: 1522-726x
CID: 1817632

Procalcitonin as a biomarker of bacterial infection in pediatric patients after congenital heart surgery

Chakravarti, Sujata B; Reformina, Diane A; Lee, Timothy M; Malhotra, Sunil P; Mosca, Ralph S; Bhatla, Puneet
BACKGROUND: Bacterial infection (BI) after congenital heart surgery (CHS) is associated with increased morbidity and is difficult to differentiate from systemic inflammatory response syndrome caused by cardiopulmonary bypass (CPB). Procalcitonin (PCT) has emerged as a reliable biomarker of BI in various populations. AIM: To determine the optimal PCT threshold to identify BI among children suspected of having infection following CPB. SETTING AND DESIGN: Single-center retrospective observational study. MATERIALS AND METHODS: Medical records of all the patients admitted between January 2013 and April 2015 were reviewed. Patients in the age range of 0-21 years of age who underwent CHS requiring CPB in whom PCT was drawn between postoperative days 0-8 due to suspicion of infection were included. STATISTICAL ANALYSIS: The Wilcoxon rank-sum test was used for nonparametric variables. The diagnostic performance of PCT was evaluated using a receiver operating characteristic (ROC) curve. RESULTS: Ninety-eight patients were included. The median age was 2 months (25th and 75th interquartile of 0.1-7.5 months). Eleven patients were included in the BI group. The median PCT for the BI group (3.42 ng/mL, 25th and 75th interquartile of 2.34-5.67) was significantly higher than the median PCT for the noninfected group (0.8 ng/mL, 25th and 75th interquartile 0.38-3.39), P = 0.028. The PCT level that yielded the best compromise between the sensitivity (81.8%) and specificity (66.7%) was 2 ng/mL with an area under the ROC curve of 0.742. CONCLUSION: A PCT less than 2 ng/mL makes BI unlikely in children suspected of infection after CHS.
PMCID:4867794
PMID: 27212844
ISSN: 0974-2069
CID: 2114492

Hybrid therapy for hypoplastic left heart syndrome: Myth, alternative, or standard-neither Minotaur nor Midas

Mosca, Ralph S
PMID: 26682621
ISSN: 1097-685x
CID: 1878202

Pulmonary valve replacement after repair of tetralogy of Fallot: Evolving strategies

Mosca, Ralph S
PMID: 26474896
ISSN: 1097-685x
CID: 1803802

Whole heart self-navigated 3D radial MRI for the creation of virtual 3D models in congenital heart disease [Meeting Abstract]

Wake, N; Feng, L; Piccini, D; Latson, L A; Mosca, R S; Sodickson, D K; Bhatla, P
Background: Three-dimensional (3D) virtual models are valuable tools that may help to better understand complex cardiovascular anatomy and facilitate surgical planning in patients with congenital heart disease (CHD). Although computed tomography (CT) images are used most commonly to create these models [1,2], Magnetic Resonance Imaging (MRI) may be an attractive alternative, since it offers superior soft-tissue characterization and flexible image contrast mechanisms, and avoids the use of ionizing radiation. However, segmentation on MRI images is inherently challenging due to noise/artifacts, magnetic field inhomogeneity, and relatively lower spatial resolution compared to CT. The purpose of this study was to evaluate the image quality and assess the feasibility of creating virtual 3D heart models using a novel prototype 3D whole heart self-navigated radial MRI technique. Methods: Free-breathing self-navigated whole heart MRI was performed on three pediatric patients: two with complex CHD (average age=17 months) and one with normal cardiac anatomy (age=17years), using a 3D radial, non-slice-selective, T2-prepared, fat-saturated bSSFP sequence on a 1.5T MRI scanner (MAGNETOM Aera, Siemens, Germany). The acquisition window (~50-55 ms) was placed in mid-diastole and was adapted for different heart rates. Imaging parameters were as follows: TR/TE=3.1/1.56 ms, FOV=200 mm3, voxel size=1 mm3, FA=115degree, and acquisition time=5-6 minutes (~12000 radial lines). Respiratory motion correction and image reconstruction was performed on the scanner as described in [3]. For comparison, conventional non-gated 3D FLASH or navigator-gated 3D bSSFP sequences were also performed. All results were blinded and randomized for image quality assessment by one pediatric cardiologist and one cardiac radiologist using a five-point scale (1=non-diagnostic, 2=poor, 3=adequate, 4=good, 5=excellent). Statistical analysis was performed to compare mean scores. DICOM images were imported to a 3D workstation (Mimics, Materialise, Leuven, Belgium) for 3D postprocessing. The cardiovascular anatomy was first segmented using a combination of automated and manual techniques; and volume rendering was performed to depict the anatomy of interest. Results: The free-breathing self-navigated 3D radial acquisition provided significantly improved image quality and myocardial wall-blood contrast (Figure 1). Mean scores were 4.58 and 2.67 for the 3D radial and FLASH/ bSSFP sequences respectively (p = 0.003). The cardiovascular anatomy was well depicted on all virtual 3D models (Figure 2). Conclusions: 3D virtual models are frequently being created to understand complex anatomy, influence surgical planning, and provide intra-operative guidance for patients with CHD. This novel free-breathing, self-navigated whole heart 3D radial sequence provided excellent image quality as compared to existing routine MR sequences. Furthermore, the (Figure Presented) superb image quality provided using this novel sequence makes it an excellent choice for the creation of 3D models
EMBASE:72183064
ISSN: 1097-6647
CID: 1950602

Anomalous Aortic Origin of a Coronary Artery Is Not Always a Surgical Disease

Mosca, Ralph S; Phoon, Colin K L
Anomalous aortic origin of the coronary artery (AAOCA) from the opposite sinus of Valsalva with an interarterial course has become a high-profile lesion as a result of its association with sudden cardiac death in otherwise young and healthy individuals. Despite our incomplete knowledge of its pathophysiology and natural history, surgical intervention is often recommended. Evidence now shows AAOCA to be relatively common, with lower than previously suspected rates of sudden cardiac death. Analysis of this information reveals that AAOCA is not always a surgical disease. Future multi-institutional studies will continue to define those subgroups best served by observation or surgery.
PMID: 27060040
ISSN: 1092-9126
CID: 2078022

Utility of rapid prototyping in complex DORV: Does it alter management decisions? [Meeting Abstract]

Bhatla, P; Chakravarti, S; Latson, L A; Sodickson, D K; Mosca, R S; Wake, N
Background: Complex ventricular-arterial (VA) relationships in patients with double outlet right ventricle (DORV) make preoperative assessment of potential repair pathways challenging. The relationship of the ventricular septal defect (VSD) to one or both great arteries must be understood and this influences the choice of surgical procedure [1] In neonates and infants with DORV, Computed Tomography (CT) is often performed due to the ability to get high spatial resolution and ECG gated images [2], however it is possible to get the necessary information from Magnetic Resonance (MR) imaging with an added advantage of avoiding exposure to ionizing radiation. Both CT and MR allow image acquisition in three dimensions (3D) but traditional viewing of the anatomy using the multiplanar reformatting is actually done in two dimensions (2D). Volume rendering from either modality may also be performed, but typically only the external vascular anatomy is depicted. We hypothesized that it is possible to accurately define the intracardiac anatomy in infants with DORV using virtual and physical 3D printed (rapid prototyped) models created from either MR or CT and this can both aid in better defining potential VA pathways and may assist in surgical decision making. Methods: Virtual and physical 3D models were generated for three patients with DORV. Non-ECG-gated 3D spoiled fast gradient echo sequence MR angiography was used for two patients. Retrospective ECG gated CT angiography images acquired in diastole were used in the third patient (to better define the coronary arteries given the suspicion of a single coronary artery by echocardiography). Blood pool segmentation (Figure 1a) was performed in all the three patients (Mimics, Materialise, Leuven, Belgium). A 2 mm shell was added to the blood pool and it was hollowed to create a patient specific heart replica (3-matic, Materialise, Leuven, Belgium). All virtual models were cut to best demonstrate the VA relationships and the models were printed. Results: The VSD and VA relationships were well visualized in all three patients using both the virtual and physical models (Figure 1b,c). The models helped the surgeons better understand the anatomy in all patients: in two patients the surgical plan was altered while the plan was confirmed in the third patient (Table 1). Conclusions: Construction of 3D models in patients with DORV is feasible and allows for extensive examination and surgical planning. This may facilitate a focused and informed surgical procedure and improve the potential for successful outcome. For purposes of DORV, non-gated MRA is sufficient to delineate the VA relationships adequately for 3D printing and enhanced clinical decision-making. CT imaging should be reserved for only those patients where additional information like coronary artery anatomy is desired
EMBASE:72183054
ISSN: 1097-6647
CID: 1950612

Neopulmonary reconstruction: Operam do [Editorial]

Mosca, Ralph S
PMID: 26424372
ISSN: 1097-685x
CID: 1789562